HomeMy WebLinkAboutZP-23-008 - 1660 Williston Road 1/31/20231 Rev 2019-11
CITY OF SOUTH BURLINGTON
Z O N I N G P E R M I T A P P L I C A T I O N
PROPERTY Street Address: _________________________________________ Application No: _________________
[office use only]
Property Owner: __________________________________________________ Parcel Size: ___________________
Property Owner Mailing Address:___________________________________________________________________
APPLICANT: __________________________________________________________________________________
Applicant Mailing Address: _______________________________________________________________________
Applicant Email: ______________________________________________ Daytime phone: _________________
1. PROPOSED project including building dimensions (describe): ________________________________________________
______________________________________________________________________________________________________
______________________________________________________________________________________________________
______________________________________________________________________________________________________
2. RELATED Site Plan, Conditional Use, PUD, Subdivision, or Misc Approval ______________________________________
3. Present USE(S) of the property:
Single family home on its own parcel
Other (please state the USE per Land Development Regulations- retail, general office, multifamily residential, etc.):
_________________________________________________________________________________________________
4. List all present structure(s) on property (describe including dimensions or square footage of each): ___________________
___________________________________________________________________________________________________
5. Does the project include a proposed change of USE?
No (the property will still be used for the same purpose)
Yes (please state proposed changed or added USES per Land Development Regulations- retail, general office,
multifamily residential, etc.): ___________________________________________________________
6. ESTIMATED total cost of improvements (materials and labor): $_______________________________
7. BUILDING footprint – i.e. size in sq. ft. of main floor of house and all attached and detached structures including enclosed
breezeways, garages, and sheds (describe): Existing:______________________ Proposed:_______________________
__________________________________________________________________________________________________
8. TOTAL impervious surfaces on site (i.e. Building footprint PLUS size in s.f. of driveways, patios, decks)
Existing:______________________ Proposed:_______________________
9. ATTACH SKETCH PLAN OR SITE PLAN
Complete the following only if the project involves changes to the dimensions of your building or other site changes (ie, not interior
renovations or roof / window / deck replacement)
2 Rev 2019-11
10. APPLICANT/OWNER CERTIFICATION
The undersigned property owner hereby consents to submission of this application and understands that if the application is
approved, the Zoning Permit and any attached conditions will be binding on the property.
_____________________________________________________________________ _________________________
Property Owner Signature PRINT NAME Date
The undersigned applicant hereby affirms that the information presented in this application is true, accurate and complete.
_____________________________________________________________________ _________________________
Applicant Signature PRINT NAME Date
OFFICE USE ONLY – ADMINISTRATIVE OFFICER ACTION – OFFICE USE ONLY
DATE Received: ___________________ FEE Received: $ _____________ Identification of zoning district: _______________
Project description: ______________________________________________________________________________________
SITE PLAN _____________________________________ ____________________________
Application # Approval Date
SUBDIVISION _____________________________________ ____________________________
Application # Approval Date
CONDITIONAL USE _____________________________________ ____________________________
Application # Approval Date
VARIANCE _____________________________________ ____________________________
Application # Approval Date
MISCELLANEOUS _____________________________________ ____________________________
Application # Approval Date
FINAL ADMINISTRATIVE OFFICER ACTION
Z O N I N G P E R M I T
□ APPROVED _________________________ ____________________________________________________________
Approval Date Administrative Officer’s Signature
Permit EFFECTIVE date _________________________ Permit EXPIRATION date ___________________________
CONDITIONS of Approval __________________________________________________________________________
□ Provided applicant copy of URBEC or VCBE Standards Handbook or □ Not Applicable
□ DENIED _________________________ _____________________________________________________________
Denial Date Administrative Officer’s Signature
REASON for DENIAL ______________________________________________________________________________________
Notice of Appeal Rights: Any interested person may appeal this decision by filing a written Notice of Appeal with the clerk of the Development Review
Board within fifteen [15] days of the date of this decision. The notice of appeal must be accompanied by a filing fee of $223.00.
This permit does NOT authorize commencement of any development activity approved by the permit until the permit takes effect as set forth
above. Site modifications and improvements made prior to this permit becoming effective may be subject to removal and site restoration if a timely
appeal is commenced.
NOTE: The applicant or permittee retains the obligation to identify, apply for, and obtain relevant state permits for this project. Call (802) 477-2241 to
speak with the regional Permit Specialist.
project name:sheet title:
sheet no.
scale:
project no.
checked by:
drawn by:
proj. date:
sheet date:project address:P802.879.51537 CARMICHAEL ST. ESSEX JUNCTION, VT 05452SCOTTPARTNERS.COMF802.872.276412/21/2022 11:47:31AMS:\1-S+P-Projects\4-MULTI-FAMILY-HOUSING\CHT - Ho Hum Motel\Drawings\Revit\Ho Hum Motel_front building.rvtHO HUM MOTEL21-1452
JRP
JLG
12/21/22
COVER SHEET
A0.0BID / CONSTRUCTION SET 12/20/22 Enter address here-
CHAMPLAIN HOUSING TRUST
HO HUM MOTEL CONVERSION
1660 Williston Rd
South Burlington, VT 05403
Owner
Champlain Housing Trust
88 King St
Burlington, VT 05401
P: (802) 862-6244
E: Javier.Garcia@champlainhousingtrust.org
Contact: Javier Garcia
Architect
Scott + Partners, Inc.
7 Carmichael St, Suite 102
Essex, VT 05452
P: (802) 879-5153
E: joel@scottpartners.com
Contact: Joel Page, AIA
Civil Engineer
Civil Engineering Associates
10 Mansfield View Lane
South Burlington, VT 05403
P: (802) 864-2323
E: dmarshall@cea-vt.com
Contact: David Marshall
Mechanical / Electrical Engineer
Pearson & Associates
a division of DuBois & King, Inc.
75 North Main Street
Waterbury, VT 05656
P: (802) 882-8789
E: alan.g@pearsonandassociates.com
david.a@pearsonandassociates.com
Contact: Alan Gould (electrical)
David Andersen (mechanical)
PROJECT LOCATION:
GENERAL
A0.0 COVER SHEET
A0.1 GENERAL NOTES AND ABBREVIATIONS
LS 1 CODE SUMMARY + PLAN - FRONT BUILDING
LS 2 CODE SUMMARY + PLAN - BACK BUILDING
LS 3 CODE SUMMARY
CIVIL
C1.0 EXISTING CONDITIONS PLAN
C2.0 PROPOSED CONDITIONS PLAN
C3.0 SITE DETAILS
C4.0 LANDSCAPE REFERENCES AND DETAILS
ARCHITECTURAL
A1.0 DEMOLITION PLANS - FRONT BUILDING
A1.1 DEMOLITION PLANS - BACK BUILDING
A2.0 FLOOR PLANS - FRONT BUILDING
A2.1 FLOOR PLANS - BACK BUILDING
A3.0 EXT. ELEVATIONS & SCHEMATIC SECTION - FRONT BUILDING
A3.1 EXTERIOR ELEVATIONS - FRONT BUILDING
A3.2 EXTERIOR ELEVATIONS - BACK BUILDING
A8.0 ENLARGED PLANS AND INTERIOR ELEVATIONS
A8.1 ENLARGED PLANS AND INTERIOR ELEVATIONS
A8.2 ENLARGED PLANS AND INTERIOR ELEVATIONS
A8.3 ENLARGED PLANS AND INTERIOR ELEVATIONS
A8.4 ENLARGED PLANS AND INTERIOR ELEVATIONS
A9.0 INTERIOR DETAILS
A11.0 DOOR SCHEDULES
DRAWINGS:
BID / CONSTRUCTION SET 12/21/2022
No Date Revisions
1. INSULATION CONTRACTOR AND OR GENERAL CONTRACTOR ARE TO PROVIDE ALL AIR SEALING MEASURES.
2. GENERAL AIR SEALING MEASURES WILL BE INSTALLED THROUGH THE USE OF INDUSTRY STANDARD MATERIALS AND
TECHNIQUES, INCLUDING: USE OF MINIMUM EXPANDING FOAM AND RIGID MATERIALS TO SEAL CRACKS GAPS AND VOIDS, AND
USE OF PRESSURE DIFFERENTIAL DIAGNOSTIC TECHNIQUES TO LOCATE AIR LEAKAGE PATHS.
3. AIR SEALING WILL INVOLVE (BUT NOT LIMITED TO) EFFECTIVE SEALING WITH APPROPRIATE PRODUCTS IN THE FOLLOWING
AREAS:
INSULATION AND AIR SEALING NOTES:
A. ALL PLUMBING, ELECTRICAL, ELECTRICAL BOX, KITCHEN FAN DUCT OR BATH FAN DUCT PENETRATIONS IN EXTERIOR
WALLS AND ATTIC WITH CAULK OR MINIMALLY EXPANDING FOAM.
B. ANY CHASES OPEN TO THE ATTIC.
C. SEALING THE GAP BETWEEN THE TOP PLATES OF INTERIOR AND EXTERIOR WALLS AND CEILING SHEET ROCK IN THE
TOP STORY WITH CAULK OR MINIMALLY EXPANDING FOAM.
D. BOTTOM EDGE OF SHEET ROCK SEALED TO SUB FLOOR OR SLAB ON EXTERIOR WALLS WITH MINIMALLY EXPANDING
FOAM.
E. METAL BATH FAN HOUSINGS SEALED TO SHEET ROCK WITH CAULK OF MINIMALLY EXPANDING FOAM.
F. AROUND WINDOW AND DOOR ROUGH OPENING, MINIMALLY EXPANDING FOAM WITH BEAD SIZE TO SEAL WINDOW FRAME
TO ROUGH OPENING, DO NOT TRY TO FILL DEPTH OF GAP.
G. AIR SEAL ATTIC PRIOR TO INSULATING.
H. INSULATING CONTRACTOR SHOULD COORDINATE AIR SEALING WORK WITH GENERAL CONTRACTOR. THE GC IS TO
ENSURE COMPLETE AND THOROUGH AIR SEALING.
I. ALL WINDOWS SHALL HAVE AN NFRC U VALUE RATING OF .35 OR LESS, AND A SOLAR HEAT GAIN COEFFICIENT (SHGC)
OF .55 OR LESS AND ARE ENERGY STAR LABELED FOR NORTHERN CLIMATE.4' - 0"3' - 4"MIRROR OVER SINK
(DIM. TO
REFLECT.SURF.)3' - 6"COAT HOOKS
TOWEL BAR2' - 0"TOILET PAPER
DISPENSER
7" - 9"
MOUNTING HEIGHTS FOR EQUIPMENT & ACCESSORIES
3' - 0"FIRE
EXTINGUISHER
CABINET
DOOR NUMBER
ROOM NUMBER
ROOM NAME
AREA
A4.1
DRAWING NUMBER
SHEET NUMBER
DRAWING NUMBER
SHEET NUMBER
DRAWING NUMBER
SHEET NUMBER
DOOR TAG
ROOM TAG
SECTION MARK
EXTERIOR ELEVATION
DETAIL
DRAWING NUMBER
SHEET NUMBER
DETAIL SECTION
1
A8.1
1
2
3
4
DRAWING NUMBER
SHEET NUMBER
DETAIL NUMBER, TYPINTERIOR ELEVATION
WINDOW TYPEWINDOW TAG
WALL TYPEWALL TAG
FLOOR FINISH TAG
FLOOR MATERIAL
SYMBOL LEGEND
1t
1i
1
A101
SIM
1
A101
1 SIM
A101
1
SIM
Room name
101
150 SF
Floor
Material
Floor
Material
###
TUB -BACK WALL
HEAD
END
WALLCONTROL
END
WALL
BACK WALL
2' - 0"1' - 0"11 7/8"2' - 0"2' - 0"
TUB -PLAN
2' - 0"
TUB -END WALL
REQUIRED BLOCKING & GRAB BAR LOCATIONS:
4' - 6"
3' - 6"1' - 0"MAX.3' - 0 1/8"1' - 0"2' - 0"
3' - 0"
TRANSFER SIDE GRAB BAR REAR WALL GRAB BAR 8"3' - 0 1/8" MAX.SIDE
WALL
SIDE
WALL
BACK WALL
6"4' - 2"6"2' - 0"6"2' - 0"6"2' - 11 7/8" MAX.8"ROLL-IN SHOWER
BACK WALL
ROLL-IN SHOWERROLL-IN SHOWER
END WALL
6"6"MAX.3' - 0 1/8"6" MAX.3' - 0 1/8" MAX.3' - 0 1/8" MAX.6"
4"
4"
4"4"
1' - 6"
NOTES:
1. VT ACCESS RULES REQUIRES BLOCKING IN ALL
APARTMENT UNITS.
2. IT IS ASSUMED THAT TUB/SHOWER UNITS FOR ALL
APARTMENTS WILL BE PURCHASED WITH INTEGRAL
BLOCKING.
3. ALL FIRST FLOOR APARTMENTS, EXCEPT THE ADA
APARTMENT(S) WILL BE CONSIDERED ADAPTABLE AND
NEED TO MEET THE STATE OF VERMONT ACCESSIBILITY
REQUIREMENTS.
4. THE DESIGNATED ADA APARTMENT(S) MUST MEET
CURRENT ADA REQUIREMENTS.
5. ALL OTHER APARTMENTS MUST MEET THE STATE OF
VERMONT RULES FOR VISITABILITY.
2x WD STUDS AT 16" O.C.
WD BLOCKING TO SUPPORT
WALL, AS REQUIRED
3 1/2" SOUND ATTENUATING
BATT INSULATION
EXISTING
SUBFLOOR
EXISTING
FRAMING
5/8" TYPE-X GWB
WALL BASE -SEE
SCHED
FIRE SAFE SEALANT
FIRE SAFE SEALANT
NOTE:
1. FIRE SEAL TOP, BOTTOM, PERIMETER AND ALL PENETRATIONS.
2. MATCH EXISTING STUD SIZE AT INFILL LOCATIONS, AND WHERE
FINISH FACES ARE INTENDED TO ALIGN.
3. SEE ADDITIONAL REQUIREMENTS IN THE SPECIFICATIONS.
5/8" TYPE-X GWB
CEILING
2x WD STUDS AT 16" O.C.
WD BLOCKING TO SUPPORT
WALL, AS REQUIRED
3 1/2" SOUND ATTENUATING
BATT INSULATION
EXISTING
SUBFLOOR
EXISTING
FRAMING
5/8" GWB
WALL BASE -SEE
SCHED
ACOUSTICAL SEALANT
ACOUSTICAL SEALANT
NOTE:
1. ACOUSTICALLY SEAL TOP, BOTTOM, PERIMETER AND ALL PENETRATIONS.
2. MATCH EXISTING STUD SIZE AT INFILL LOCATIONS, AND WHERE FINISH
FACES ARE INTENDED TO ALIGN.
3. SEE ADDITIONAL REQUIREMENTS IN THE SPECIFICATIONS.
GWB CEILING
TYPE STUD
SIZE
PART.
THICK.
SOUND
ATTN.
BLANKET
STC NOTES
1A 3 1/2"4 3/4"3 1/2"
1B 5 1/2"6 3/4"5 1/2"
36
UL #
38
RATTING
1-HRU305
1-HRU305
TYPE STUD
SIZE
PART.
THICK.
SOUND
ATTN.
BLANKET
STC NOTES
2A 3 1/2"4 3/4"3 1/2"
2B 5 1/2"6 3/4"5 1/2"
36
UL #
38
RATTING
N/A
N/A
N/A
N/A
project name:sheet title:
sheet no.
scale:
project no.
checked by:
drawn by:
proj. date:
sheet date:project address:P802.879.51537 CARMICHAEL ST. ESSEX JUNCTION, VT 05452SCOTTPARTNERS.COMF802.872.2764As indicated
12/21/2022 11:47:32AMS:\1-S+P-Projects\4-MULTI-FAMILY-HOUSING\CHT - Ho Hum Motel\Drawings\Revit\Ho Hum Motel_front building.rvtHO HUM MOTEL21-1452
JRP
JLG
12/21/22
GENERAL NOTES
AND
ABBREVIATIONS
A0.1BID / CONSTRUCTION SET 12/20/22 Enter address here-
GENERAL NOTES:
1. GENERAL CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS IN THE FIELD AND REPORT ANY DISCREPANCIES TO THE ARCHITECT
PRIOR TO STARTING ANY WORK.
2. DIMENSIONS SHALL BE TO FACE OF SURFACE MATERIAL, UNLESS OTHERWISE NOTED OR INDICATED.
3. PATCH AND REPAIR ALL SURFACES/MATERIALS THAT ARE DAMAGED BY DEMOLITION. PATCH AND REPAIR ANY CRACKS, DINGS,
HOLES, ETC., NOT RELATED TO DEMOLITION, AT ALL EXPOSED SURFACES SCHEDULED TO BE PAINTED.
4. ALL NEW GWB WALLS SHALL BE TAPED, SMOOTH FINISHED, AND PAINTED W/ (1) COAT OF LATEX PRIMER AND (2) COATS OF LATEX
EGGSHELL PAINT, COLORS TO BE SELECTED BY ARCHITECT.
5. CONTRACTOR SHALL COMPLETELY PAINT ALL ROOMS WITH ANY NEW WORK OCCURRING IN THEM UNLESS NOTED OTHERWISE.
ABBREVIATIONS
ABBR DESCRIPTION
# NUMBER OF POUNDS
& AND
= EQUAL
@ AT
A/C AIR CONDITIONING
A/E ARCHITECT/ENGINEER
ABV ABOVE
AC ACOUSTICAL
ACT ACOUSTIC CEILING TILE
AD ACCESS DOOR or AREA DRAIN
ADD ADDITIONAL
ADJ ADJACENT
ADJT ADJUSTABLE
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
ALT ALTERNATE
ALUM ALUMINUM
ANCH ANCHOR
ANCH B ANCHOR BOLT
ANOD ANODIZED
AP ACCESS PANEL
APPROX APPROXIMATELY
ARCH ARCHITECT/ARCHITECTURAL
ASB ASBESTOS
AUTO AUTOMATIC
AUX AUXILIARY
AV AUDIO VISUAL
AVG AVERAGE
B BOLT
BC BRICK COURSE
BD BOARD
BEL BELOW
BET BETWEEN
BIT BITUMINOUS
BL BLANKET
BLDG BUILDING
BLK BLOCK
BLKG BLOCKING
BM BEAM, BENCH MARK
BN BULL NOSE
BO BOTTOM OF
BOS BOTTOM OF STEP
BOT BOTTOM
BRCG BRACING
BRG BEARING
BRK BRICK
BRKT BRACKET
BS BOTH SIDES
BSMT BASEMENT
BUR BUILT UP ROOFING
BW BOTH WAYS
CAB CABINET
CB CATCH BASIN
CEM CEMENT
CER CERAMIC
CF CUBIC FEET
CG CORNER GUARD
CH CEILING HEIGHT
CHAM CHAMFER
CIR CIRCLE
CIRC CIRCUMFERENCE
CJ CONTROL JOINT or
CONSTRUCTION JOINT
CL CENTER LINE
CLF CHAIN LINK FENCE
CLNG CEILING
CLOS CLOSET
CLR CLEAR
CLS CLOSURE OR CLOSER
CM CONSTRUCTION MANAGER
CMU CEMENT MASONRY UNIT
CO CLEAN OUT
COL COLUMN
COMP COMPRESSIBLE
CONC CONCRETE
CONST CONSTRUCTION
CONT CONTINUOUS
CONTR CONTRACTOR
COORD COORDINATE
COR CORRUGATED
CORR CORRIDOR
CPT CARPET
CR CHAIR RAIL
CRS COURSE
CSMT CASEMENT
CT CERAMIC TILE
CTR CENTER
CTSK COUNTERSUNK
CU CUBIC
CUH CABINET UNIT HEATER
CW COLD WATER
CYL CYLINDER
D DEEP OR DEPTH
DB DECIBELS
DBL DOUBLE
DEM DEMOLISH
DEPT DEPARTMENT
DET DETAIL
DF DRINKING FOUNTAIN
DIA DIAMETER
DIAG DIAGONAL
DIFF DIFFUSER
DIM DIMENSION
DISP DISPENSER
DMT DEMOUNTABLE
DN DOWN
DP DAMP PROOFING
DR DOOR OR DRAIN
DS DOWN SPOUT
DWG DRAWING
E EAST
EA EACH
EIFS EXTERIOR INSULATION FINISH
SYSTEM
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRIC OR ELECTRICAL
ABBREVIATIONS
ABBR DESCRIPTION
ELEV ELEVATOR
EMER EMERGENCY
ENAM ENAMEL
ENCL ENCLOSURE
ENG ENGINEER
ENT ENTRANCE
EOS EDGE OF SLAB
EQ EQUAL
EQUIP EQUIPMENT
EW EACH WAY
EWC ELEC. WATER COOLER
EXH EXHAUST
EXIST EXISTING
EXIST EXISTING
EXP EXPANSION
EXPD EXPANDED
EXPO EXPOSED
EXT EXTERIOR
EXTR EXTRUDED
FA FIRE ALARM
FAS FASTENER
FB FACE BRICK OR FLAT BAR
FC FLEXIBLE CONNECTION
FD FLOOR DRAIN or FIRE DAMPER
FDN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CAB
FFE FINISHED FLOOR ELEVATION
FGL FIBERGLASS
FHC FIRE HOSE CABINET
FIN FINISHED
FIX FIXTURE
FLASH FLASHING
FLEX FLEXIBLE
FLOUR FLUORESCENT
FLR FLOOR
FLRG FLOORING
FOW FACE OF WALL
FP FIRE PROOFING
FR FIRE RATED
FRM FRAME
FRP FIBERGLASS REINF. PANELING
FRT FIRE RET. TREATED
FT FOOT OR FEET
FTG FOOTING
FTR FIN TUBE RADIATION
FUR FURRED OR FURRING
FURN FURNISHED
FUT FUTURE
FXD FIXED
GA GAUGE
GALV GALVANIZE(D)
GB GRAB BAR
GC GENERAL CONTRACTOR
GD GRADE
GDR GUARDRAIL
GEN GENERAL
GL GLASS
GRD GROUND
GS GRAVEL STOP
GT GROUT
GWB GYPSUM WALL BOARD
GYP GYPSUM
HB HOSE BIB
HBD HARDBOARD
HC HOLLOW CORE or HANDICAP
ACCESSIBLE
HDR HANDRAIL
HDW HARDWARE
HDWD HARDWOOD
HM HOLLOW METAL
HOR HORIZONTAL
HP HIGH PRESSURE
HR HOUR
HT HEIGHT
HTG HEATING
HTR HEATER
HVAC HEATING, VENT. & A/C
HW HOT WATER
ID INSIDE DIAMETER
IN INCH
INCL INCLUDED/ING
INFO INFORMATION
INSUL INSULATION
INT INTERIOR
INTER INTERMEDIATE
JAN JANITOR
JB JUNCTION BOX
JC JANITOR’S CLOSET
JST JOIST
JT JOINT
K PL KICK PLATE
KD KNOCK DOWN
LAM LAMINATE
LAV LAVATORY
LBS POUNDS
LF LINEAL FEET
LF F LIGHT FIXTURE
LFLI LANDLORD FURNISHED
LANDLORD INSTALLED
LFLI LANDLORD FURNISHED TENANT
INSTALLED
LIQ LIQUID
LOC LOCATION
LT LIGHT
LTG LIGHTING
LTL LINTEL
LVR LOUVER
LW LONG WAY
MACH MACHINE
MAINT MAINTENANCE
MAS MASONRY
MAT MATERIAL
MAX MAXIMUM
MCF METAL FURRING CHANNEL
MD METAL DECKING
MECH MECHANICAL
ABBREVIATIONS
ABBR DESCRIPTION
MED MEDIUM
MEMB MEMBER
MFR MANUFACTURER
MH MANHOLE
MHO MAGNETIC HOLD OPEN
MIN MINIMUM OR MINUTE
MIRR MIRROR
MISC MISCELLANEOUS
MLD MOLDING
MO MASONRY OPENING
MOV MOVABLE
MR MOISTURE RESISTANT
MTD MOUNTED
MTL METAL
MULL MULLION
N NORTH
N/A NOT APPLICABLE
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OF OUTSIDE FACE
OFCI OWNER FURNISHED
CONTRACTOR INSTALLED
OFE OWNER FURNISHED
EQUIPMENT
OFF OFFICE
OFI OWNER FURNISHED AND
INSTALLED
OH OVERHEAD
OHD OVER HEAD DOOR
OPNG OPENING
OPP OPPOSITE
OPPH OPPOSITE HAND
OZ OUNCE
PART PARTITION
PC PRECAST OR PIECE
PED PEDESTAL
PERF PERFORATED
PERIM PERIMETER
PFN PREFINISHED
PH PARTIAL HEIGHT
PL PLATE
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLUM PLUMBING
PLWD PLYWOOD
PNL PANEL
PORC PORCELAIN
PREFAB PREFABRICATED
PRESS PRESSURE
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PAINT OR POINT
PTD PAINTED
PVC POLY VINYL CHLORIDE
PVMT PAVEMENT
PVR PAVER
QTY QUANTITY
R RADIUS/RISER
RA RETURN AIR
RAD RADIATION
RD ROOF DRAIN, ROAD
REBAR REINFORCING BAR
REC RECESSED
REF REFERENCE
REFL REFLECTED
REFR REFRIGERATOR
REG REGISTER
REINF REINFORCED
REM REMOVE
REQD REQUIRED
RES RESISTANT
RESIL RESILIENT
RET RETAINING
REV REVISION/REVERSE
RF ROOF
RFG ROOFING
RM ROOM OR ROOF MEMBRANE
RO ROUGH OPENING
RSL RESILIENT FLOORING
S SOUTH
SAT SUSPENDED ACOUSTICAL TILE
SC SOLID CORE
SCHED SCHEDULE
SECT SECTION
SF SQUARE FEET
SHLV SHELVING
SHT SHEET
SIM SIMILAR
SLDG SLIDING
SLNT SEALANT
SPCG SPACING
SPEC SPECIFICATION
SPKR SPEAKER
SPR HD SPRINKLER HEAD
SQ SQUARE
SS STAINLESS STEEL
STC SOUND TRANSMISSION CLASS
STD STANDARD
STIFF STIFFENER
STL STEEL
STOR STORAGE
STRUCT STRUCTURAL
SURF SURFACE
SUSP SUSPENDED
SV SHEET VINYL
SYM SYMBOL
SYS SYSTEM
T TREAD, TILE
T&G TONGUE AND GROOVE
TBD TACK BOARD
TEL TELEPHONE
TEMP TEMPORARY, TEMPERATURE
TFLI TENANT FURNISHED LANDLORD
INSTALLED
ABBREVIATIONS
ABBR DESCRIPTION
TFTI TENANT FURNISHED or TENANT
INSTALLED
THERM THERMOMETER
THK THICK
THR THRESHOLD
THRU THROUGH
TK BD TACK BOARD
TLT TOILET
TOC TOP OF CURB
TOF TOP OF FOOTING
TOS TOP OF STEEL
TOW TOP OF WALL
TR TRENCH
TRT TREATED
TYP TYPICAL
UC UNDER CUT
UH UNIT HEATER
UL UNDERWRITER’S
LABORATORIES
UNFIN UNFINISHED
UNO UNLESS NOTED OTHERWISE
UR URINAL
UTIL UTILITY
VAC VACUUM
VAR VARIABLE
VB VAPOR BARRIER
VCT VINYL COMPOSITE TILE
VEH VEHICLE
VERT VERTICAL
VEST VESTIBULE
VIF VERIFY IN FIELD
VNR VENEER
VOL VOLUME
VP VENT PIPE
VTR VENT THROUGH ROOF
VWC VINYL WALL COVERING
W WEST
W/ WITH
W/O WITH OUT
WC WATER CLOSET
WD WOOD
WF WIDE FLANGE
WG WIRE GLASS
WIN WINDOW
WP WATER PROOF
WR WATER RESISTANT
WS WATER STOP
WT WEIGHT
WWF WELDED WIRE FABRIC
PARTITION TYPES
1 1HR RATED INTERIOR WALL - WOOD STUDS
2 TYPICAL INTERIOR WALL - WOOD STUDS
No Date Revisions
REF.REF.REF.REF.REF.REF.REF.REF.REF.
REF.
FIRE BARRIER RATING DESIGNATION
1 HOUR FIRE RATED BARRIER
EXIT
TRAVEL DISTANCE
EXIT
FT
DN
EXISTING 1 HR RATED
DEMISING WALLS, TYPICAL
BETWEEN UNITS.
EXISTING 1 HR RATED DEMISING
WALL, TYP. -NEW INFILL TO MATCH
ADJACENT CONSTRUCTION -FILL ALL
GAPS, CRACKS, HOLES, ETC. TO
ENSURE AN INTACT BARRIER
CRAWL SPACE
ACCESS
CRAWL SPACE
ACCESS
CRAWL SPACE
ACCESS
APT #3
1-BR UNIT
370 SF
APT #2
1-BR UNIT
574 SF
APT #4
1-BR UNIT
535 SF
APT #5
1-BR UNIT
405 SF
APT #1
1-BR UNIT
630 SF
APT #8
1-BR UNIT
370 SFAPT #6
1-BR UNIT
405 SF
APT #7
1-BR UNIT
520 SF
APT #9
1-BR UNIT
405 SF
APT #10
1-BR UNIT
405 SF
BASEMENT
ACCESS
OFFICE
53'
31'
STORAGE
4
A3.0
804 SF
MECHANICAL
3
CRAWL
SPACE
EXISTING STAIR
EXISTING
CHIMNEY
UP
CRAWL SPACE
SLAB
ON
GRADE
CRAWL
SPACE
CRAWL
SPACE
CRAWL SPACE
ACCESS
CRAWL SPACE
ACCESS
CRAWL SPACE
ACCESS
1-HR FLOOR / CEILING ASSEMBLY
REQUIRED AT MECHANICAL ROOM
(NO SPRINKLER REQUIRED W/ I-HR
RATING, PER VT BUILDING & SAFETY
CODE - SEE CODE REVIEW)project name:sheet title:
sheet no.
scale:
project no.
checked by:
drawn by:
proj. date:
sheet date:project address:P802.879.51537 CARMICHAEL ST. ESSEX JUNCTION, VT 05452SCOTTPARTNERS.COMF802.872.2764As indicated
1/9/2023 12:38:36 PMS:\1-S+P-Projects\4-MULTI-FAMILY-HOUSING\CHT - Ho Hum Motel\Drawings\Revit\Ho Hum Motel_front building.rvtHO HUM MOTEL21-1452
JRP
JLG
12/21/22
CODE SUMMARY
+ PLAN -FRONT
BUILDING
LS 1BID / CONSTRUCTION SET 12/20/22 Enter address here01/09/23
1/8" = 1'-0"1 FIRST FLOOR LIFE SAFETY PLAN
1/16" = 1'-0"2 BASEMENT LIFE SAFETY PLAN
GROSS AREA = 5680 SF
No Date Revisions
WDWDWDREF.REF.REF.
REF.
REF.REF.REF.
REF.
REF.REF.FIRE BARRIER RATING DESIGNATION
1 HOUR FIRE RATED BARRIER
EXIT
TRAVEL DISTANCE
EXIT
FT
DN
DN
DN
UP
DN
UP
EXISTING STAIR
EXISTING STAIR
EXISTING 1 HR RATED DEMISING
WALL, TYP. -NEW INFILL TO MATCH
ADJACENT CONSTRUCTION -FILL ALL
GAPS, CRACKS, HOLES, ETC. TO
ENSURE AN INTACT BARRIER
1:20 MAX SLOPE WALKWAY
1:20 MAX SLOPE WALKWAY
EXISTING SLAB
ON GRADE
EXISTING SLAB ON
GRADE
APT #15
ACCESSIBLE
1-BR UNIT
580 SF
APT #14
1-BR UNIT
580 SF
MECHANICAL
APT #13
1-BR UNIT
290 SF
APT #12
1-BR UNIT
585 SF
APT #11
ACCESSIBLE
1-BR UNIT
580 SF
LAUNDRY
CRAWL SPACE
ACCESS
NOTE: BUILDING TO BE PROTECTED BY
AN AUTOMATIC SPRINKLER SYSTEM
DN
DN
EXISTING STAIR
EXISTING STAIR
EXISTING 1 HR RATED DEMISING
WALL, TYP. -NEW INFILL TO MATCH
ADJACENT CONSTRUCTION -FILL ALL
GAPS, CRACKS, HOLES, ETC. TO
ENSURE AN INTACT BARRIER
APT #20
1-BR UNIT
630 SF
APT #19
1-BR UNIT
630 SF
APT #17
1-BR UNIT
630 SF
APT #16
1-BR UNIT
630 SF
APT #18
1-BR UNIT
770 SF
STORAGE
STORAGE
SLAB
ON
GRADE
SLAB
ON
GRADE
CRAWL
SPACE
CRAWL
SPACE
CRAWL SPACE ACCESS
project name:sheet title:
sheet no.
scale:
project no.
checked by:
drawn by:
proj. date:
sheet date:project address:P802.879.51537 CARMICHAEL ST. ESSEX JUNCTION, VT 05452SCOTTPARTNERS.COMF802.872.2764As indicated
12/21/2022 11:42:10AMS:\1-S+P-Projects\4-MULTI-FAMILY-HOUSING\CHT - Ho Hum Motel\Drawings\Revit\Ho Hum Motel_back building.rvtHO HUM MOTEL21-1452
JRP
JLG
12/21/22
CODE SUMMARY
+ PLAN -BACK
BUILDING
LS 2BID / CONSTRUCTION SET 12/21/22 Enter address here-
1/8" = 1'-0"1 FIRST FLOOR LIFE SAFETY PLAN
1/8" = 1'-0"2 SECOND FLOOR LIFE SAFETY PLAN
1/16" = 1'-0"3 CRAWL SPACE LIFE SAFTY PLAN
No Date Revisions
project name:sheet title:
sheet no.
scale:
project no.
checked by:
drawn by:
proj. date:
sheet date:project address:P802.879.51537 CARMICHAEL ST. ESSEX JUNCTION, VT 05452SCOTTPARTNERS.COMF802.872.27641/9/2023 12:38:36 PMS:\1-S+P-Projects\4-MULTI-FAMILY-HOUSING\CHT - Ho Hum Motel\Drawings\Revit\Ho Hum Motel_front building.rvtHO HUM MOTEL21-1452
JRP
JLG
12/21/22
CODE SUMMARY
LS 3BID / CONSTRUCTION SET 12/20/22 Enter address here01/09/23
No Date Revisions
T
T ET
C
E
TC
E
TC
ETC ETC ETC ETC ETC ETC ETC ETC ETC ETC ETC ETC ETC ETC ETC ETCETCOE
OE
ETCETCETCETCETCETC
ETC
T T T T T T T T T T T
T
CATCH BASIN
RIM = 325.2
AIRP
O
R
T
R
O
A
D
WILLISTON ROAD
TO LO
G
W
O
O
D
S
T.
-
>
<- TO MILLS AVE.
TO KENNEDY DR. ->
EXIST. MOTEL BLDG.
EXIST. MOTEL BLDG.
EXIST.
STORAGE EXIST
.
OFF
ICE
BLDG
.
MOOSE
LODGE
OFFICEPAVED
PAVED
PAVED
PAVEDPAVEDPAVED
(3
)
A
/C
UN
ITS
FENCE
PALI
S
S
A
D
E
F
E
N
C
E
STOCKAD
E
F
E
N
C
E
CHAIN LIN
K
VIN
Y
L
F
E
N
C
E CHAIN
L
INK
STOCKADE FENCEFENCES
ST
ST
ST
ST
ST
ST
S GOVERHANGOVERHANGOVERHANG
OVERHANGT
CATCH BASIN
RIM = 326.1
CATCH BASIN
RIM = 329.7
CATCH BASIN
RIM = 329.0
SEWER MANHOLE
RIM = 329.0
SEWER MANHOLE
RIM = 326.5
G G G G G G G GGGG
GATE
GATE
GATE
FENCE FENCEBOLLARD
(TYP.)
ALUMINUM
THRESHOLD
EL.= 330.5
ALUMINUM
THRESHOLD
EL.= 330.5
ALUMINUM
THRESHOLD
EL.= 330.6
CATCH BASIN
CATCH BASIN
RIM = 328.426" PINE
42" OAK
24" OAK
36" OAK
32" OAK
ALUMINUM
THRESHOLD
EL.= 331.6
BALCONY
/
O
V
E
R
H
A
N
G
BALCONY /
OVERHANG
ALUMINUM
THRESHOLD
EL.= 331.7
F.F.E.CONC.
= 331.0
F.F.E.CONC.
= 331.0
159'±
227'±153'±
313'±143'±CEDAR HEDGE ROW CEDAR HEDGE ROWSIGNPLANTERPLANTER
CEDARS
GAS METER
24" PINE
GAS METER
ALUMINUM
THRESHOLD
EL.= 331.7
8" SPRUCE
10" SPRUCE
ELEC.
METER
ELEC.
METER
TEL.
PED.
UTILITY
CABINET
PLANTER
OVERHANG
ALUMINUM
THRESHOLD
EL.= 330.6
CONC. SIDEWALK
CONC.
SI
D
E
W
A
L
K
ELEC. OUTLET
WITH POST
LIGHT
WITH POSTGATECONC. WALK BELOW CONC. WALK
BELOW
FENC
E
CEDAR
S
CONC.
n/f
NFI VERMONT INC.
CHAMPLAIN HOUSING
TRUST, INC.
n/f
J. ROCK
n/f
S. GOLDSMITH TRUST
G. ROSE TRUST
n/f
M. TUCO
n/f
1636 WILLISTON ROAD LLC.
n/f
MPH SOUTH BURLINGTON
PROPERTIES LLC.
n/f
1633 WILLISTON LLC.n/f
MCLEAN PROPERTIES LLC.
n/f
SUDO 7 LLC.
ZONING:
RESIDEN
T
I
A
L
4
COMMER
C
I
A
L
1
-
R
E
S
I
D
E
N
T
I
A
L
1
2
COMMERCIAL 1 - RESIDENTIAL 12COMMERCIAL 1 - RESIDENTIAL 12COMMERCIAL
1
-
RES
IDENT
IAL
12COMMERCIAL
1
-
RES
IDENT
IAL
12
331
331
330330330
330
330
330
329329329
329
3293
2
9
3
2
9
3
2
9
329
329
328 328
328
328
328
327
327 327
327
326
326
326
+ 329.7±
DSM
DSM
MAB
1" = 20'
22141
C1.0
04/29/2022
LOCATION MAP
1" = 2000'
CHAMPLAIN
HOUSING TRUST,
INC.
1660 WILLISTON ROAD
SOUTH BURLINGTON
VERMONT 05403
"HO HUM MOTEL"
PROPERTY
EXISTING
CONDITIONS
PLAN
A
C
CIVIL ENGINEERING ASSOCIATES, INC.
E
10 MANSFIELD VIEW LANE, SOUTH BURLINGTON, VT 05403
P: 802-864-2323 FAX: 802-864-2271 web: www.cea-vt.com
1660 WILLISTON ROAD
SOUTH BURLINGTON, VT
NOTES
1.UTILITIES SHOWN DO NOT PURPORT TO CONSTITUTE OR REPRESENT ALL
UTILITIES LOCATED UPON OR ADJACENT TO THE SURVEYED PREMISES.
EXISTING UTILITY LOCATIONS ARE APPROXIMATE ONLY. THE CONTRACTOR
SHALL FIELD VERIFY ALL UTILITY CONFLICTS. ALL DISCREPANCIES SHALL BE
REPORTED TO THE ENGINEER. THE CONTRACTOR SHALL CONTACT DIG SAFE
(888-344-7233) PRIOR TO ANY CONSTRUCTION.
2.PROPERTY LINE INFORMATION IS APPROXIMATE AND BASED ON EXISTING TAX
MAP INFORMATION. THIS PLAN IS NOT A BOUNDARY SURVEY AND IS NOT
INTENDED TO BE USED AS ONE. MONUMENTATION RECOVERED IS CONSISTENT
WITH RECORDED DOCUMENTS.
3.SITE INFORMATION IS BASED ON A FIELD SURVEY PERFORMED BY CIVIL
ENGINEERING ASSOCIATES, INC APRIL 2022. CIVIL ENGINEERING ASSOCIATES,
INC. SURVEY ORIENTATION IS "GRID NORTH", VERMONT COORDINATE SYSTEM
OF 1983 (HORIZONTAL) AND NAVD88 (VERTICAL) ESTABLISHED FROM GPS
OBSERVATIONS ON SITE.
4.ALL OTHER SITE INFORMATION IS BASED UPON ORTHOMETRIC PHOTOGRAPHY.
116
2
LEGEND
E
G
ST
S
T
W
EXISTING CONTOUR
EXISTING CURB
EXISTING FENCE
EXISTING PAVEMENT
EXISTING ELECTRIC
EXISTING GAS
EXISTING STORM
EXISTING GRAVITY SEWER
EXISTING TELEPHONE
EXISTING WATER
EXISTING SEWER MANHOLE
EXISTING STORM MANHOLE
EXISTING CATCH BASIN
EXISTING HYDRANT
EXISTING SHUT OFF
EXISTING UTILITY POLE
EXISTING LIGHT POLE
EXISTING GUY WIRE/POLE
EXISTING SIGN
EXISTING DECIDUOUS TREE
EXISTING CONIFEROUS TREE
EDGE OF BRUSH/WOODS
APPROXIMATE SETBACK LINE
APPROXIMATE PROPERTY LINE
IRON ROD/PIPE FOUND
S
D
PROJECT
LOCATION
T EXISTING TELEPHONE MANHOLE
ZONING REQUIREMENTS:
COVERAGE
CATEGORY
LOT BUILDING
ZONING EXISTING
SETBACK
ZONING DISTRICT: COMMERCIAL 1 / RESIDENTIAL 12 *
FRONT YARD 15'±
PARCEL - MULTIFAMILY
SIDE YARD
REAR YARD
40%
60%
30'
10'
30'
LOT COVERAGE
17.4%
57.3%
13'±
10'±
* RESIDENTIAL 12 ZONING REGULATIONS UTILIZED
3,500 S.F / UNIT
(MAX. 12 UNITS PER AC.)
57,279 S.F.
(12 UNITS)P:\AutoCADD Projects\2022\22141-Champlain Housing Trust\1-CADD Files-22141\dwg\22141 - Site.dwg, 12/15/2022 9:58:03 AM, DWG To PDF.pc3
UP
UP
ROOM 13
ROOM 12
ROOM 11
ROOM 22
LAUNDRY
STORAGE
ROOM 14 ROOM 15 ROOM 16 ROOM 17 ROOM 18
ROOM 19 ROOM 20
ROOM 21
HALLWAY VESTIBULEOFFICE
ROOM 23
ROOM 24
ROOM 25
ROOM 26
REMOVE DISHWASHER
NOTE:
REMOVE ALL FURNITURE
DN
PRESERVE
EXISTING STAIR
TO BASEMENT
1
1
4
1
1
2
2
4
1
1
2
5
3
3
3
3
33333333
3
3
3
1
1
1a
3
1a
1a 1a
1a
1a
2
1a
CREATE OR ENLARGE
FLOOR OPENING FOR
CRAWL SPACE ACCESS
LADDER
DEMO OPENING IN EXT
WALL FOR NEW DOOR TO
BASEMENT ACCESS
DEMO OPENING IN EXT
WALL FOR NEW DOOR TO
BASEMENT ACCESS
CREATE OR ENLARGE
FLOOR OPENING FOR
CRAWL SPACE ACCESS
LADDER
DEMO FLOOR OPENING FOR
CRAWL SPACE ACCESS
DEMO EXISTING
EQUIPMENT,
SHELVING, ETC.
2
2
CRAWL SPACE
CRAWL SPACE
MECHANICAL
3
EXISTING STAIR
CRAWL SPACE
DEMOLITION LEGEND
DEMOLISH WINDOW
DEMOLISH KITCHEN CABINETS,
COUTERTOP AND APPLIANCES,
PRESERVE PLUMBING ROUGH IN
4
5 DEMOLISH STAIR
1 DEMOLISH WALL
2 DEMOLISH DOOR AND FRAME
3 DEMOLISH BATHROOM FIXTURE
PRESERVE PLUMBING ROUGH IN
2a DEMOLISH DOOR AND FRAME,
ENLARGE OPENING, COORD W/ PLAN
1a DEMOLISH OPENING IN WALL
FOR NEW DOOR AND FRAME,
COORD W/ PLAN
3a
DEMOLISH BATHROOM FIXTURE
RECONFIGURE PLUMBING
ROUGH IN PER KITCHEN LAYOUT
6
5
1
1a
5a
project name:sheet title:
sheet no.
scale:
project no.
checked by:
drawn by:
proj. date:
sheet date:project address:P802.879.51537 CARMICHAEL ST. ESSEX JUNCTION, VT 05452SCOTTPARTNERS.COMF802.872.2764As indicated
12/21/2022 11:47:34AMS:\1-S+P-Projects\4-MULTI-FAMILY-HOUSING\CHT - Ho Hum Motel\Drawings\Revit\Ho Hum Motel_front building.rvtHO HUM MOTEL21-1452
JRP
JLG
12/21/22
DEMOLITION
PLANS -FRONT
BUILDING
A1.0BID / CONSTRUCTION SET 12/20/22 Enter address here-
1/8" = 1'-0"1 EXISTING FIRST FLOOR PLAN
1/16" = 1'-0"2 EXISTING BASEMENT PLAN
1/8" = 1'-0"3 ALTERNATE DEMO PLAN FOR UNITS 1,2,5 & 6
No Date Revisions
T
T
E
T
C
E
TC
E
TC
ETC ETC ETC ETC ETC ETC ETC ETC ETC ETC ETC ETC ETC ETC ETC ETCETCOE
OE
ETCETCETCETCETCETC
T T T T T T T T T T T
T
CATCH BASIN
RIM = 325.2
AIRP
O
R
T
R
O
A
D
WILLISTON ROAD
TO LO
G
W
O
O
D
S
T.
-
>
<- TO MILLS AVE.
TO KENNEDY DR. ->
EXIST. MOTEL BLDG.
EXIST. MOTEL BLDG.
EXIST.
STORAGE EXIST
.
OFF
ICE
BLDG
.
MOOSE
LODGE
OFFICEPAVED
PAVED
PAVED
PAVEDPAVEDPAVED
(3
)
A
/C
UN
ITS
FENCE
PALI
S
S
A
D
E
F
E
N
C
E
STOCKAD
E
F
E
N
C
E
CHAIN LI
N
K
VIN
Y
L
F
E
N
C
E CHAIN
L
INK
STOCKADE FENCEFENCES
ST
ST
ST
ST
ST
ST
S GOVERHANGOVERHANGOVERHANG
OVERHANGT
CATCH BASIN
RIM = 326.1
CATCH BASIN
RIM = 329.7
CATCH BASIN
RIM = 329.0
SEWER MANHOLE
RIM = 329.0
SEWER MANHOLE
RIM = 326.5
G G G G G G G GGGG
GATE
GATE
GATE
FENCE FENCEBOLLARD
(TYP.)
ALUMINUM
THRESHOLD
EL.= 330.5
ALUMINUM
THRESHOLD
EL.= 330.5
ALUMINUM
THRESHOLD
EL.= 330.6
CATCH BASIN
CATCH BASIN
RIM = 328.426" PINE
42" OAK
24" OAK
36" OAK
32" OAK
ALUMINUM
THRESHOLD
EL.= 331.6
BALCONY
/
O
V
E
R
H
A
N
G
BALCONY /
OVERHANG
ALUMINUM
THRESHOLD
EL.= 331.7
F.F.E.CONC.
= 331.0
F.F.E.CONC.
= 331.0
159'±
227'±153'±
313'±143'±CEDAR HEDGE ROW CEDAR HEDGE ROWSIGNPLANTERPLANTER
CEDARS
GAS METER
24" PINE
GAS METER
ALUMINUM
THRESHOLD
EL.= 331.7
8" SPRUCE
10" SPRUCE
ELEC.
METER
ELEC.
METER
TEL.
PED.
UTILITY
CABINET
PLANTER
OVERHANG
ALUMINUM
THRESHOLD
EL.= 330.6
CONC. SIDEWALK
CONC.
SI
D
E
W
A
L
K
ELEC. OUTLET
WITH POST
LIGHT
WITH POSTGATECONC. WALK BELOW CONC. WALK
BELOW
FENC
E
CEDAR
S
CONC.
n/f
NFI VERMONT INC.
CHAMPLAIN HOUSING
TRUST, INC.
n/f
J. ROCK
n/f
S. GOLDSMITH TRUST
G. ROSE TRUST
n/f
M. TUCO
n/f
1636 WILLISTON ROAD LLC.
n/f
MPH SOUTH BURLINGTON
PROPERTIES LLC.
n/f
1633 WILLISTON LLC.n/f
MCLEAN PROPERTIES LLC.
n/f
SUDO 7 LLC.
ZONING:
RESIDEN
T
I
A
L
4
COMMER
C
I
A
L
1
-
R
E
S
I
D
E
N
T
I
A
L
1
2
COMMERCIAL 1 - RESIDENTIAL 12COMMERCIAL 1 - RESIDENTIAL 12COMMERCIAL
1
-
RES
IDENT
IAL
12COMMERCIAL
1
-
RES
IDENT
IAL
12
331
331
330330330
330
33
0
330
329329329
329
3293293
2
9
3
2
9
329
329
328 328
328
328
328
327
327 327
327
326
326
326
+ 329.7±
PROPOSED 10'x24'
DUMPSTER / COMPOST
ENCLOSURE
SEE SHEET C3.0
PROPOSED SHORT TERM
BIKE RACK
EXPAND EX. CONC. PAD
PROPOSED GAZEBO
W/ PAD SEE DETAIL
SHEET C4.0
PARKLET
PROPOSED BENCHES
SEE DETAIL SHEET C4.0
PROPOSED MAPLE
PROPOSED
HORNBEAM
PROPOSED
SERVICEBERRY
PROPOSED
SERVICEBERRY
PROPOSED
HORNBEAM
EXISTING FENCE
TO BE REMOVED
EXISTING GATES
AND FENCE TO BE
REMOVED
SNOW
STORAGE
AREA
PROPOSED RAMP
MAX. SLOPE 1:20
NEW CONC. LANDING
ELEV. 330.92%EXISTING PARKING
STRIPING TO BE
REMOVED
DSM
DSM
MAB
1" = 20'
22141
C2.0
04/29/2022
LOCATION MAP
1" = 2000'
CHAMPLAIN
HOUSING TRUST,
INC.
1660 WILLISTON ROAD
SOUTH BURLINGTON
VERMONT 05403
"HO HUM MOTEL"
PROPERTY
PROPSOED
CONDITIONS
PLAN
A
C
CIVIL ENGINEERING ASSOCIATES, INC.
E
10 MANSFIELD VIEW LANE, SOUTH BURLINGTON, VT 05403
P: 802-864-2323 FAX: 802-864-2271 web: www.cea-vt.com
09/08/22 DSM REVISED PROPOSED SITE PLAN
1660 WILLISTON ROAD
SOUTH BURLINGTON, VT
116
2
E
EXISTING FENCE
EXISTING PAVEMENT
EXISTING ELECTRIC
EXISTING WATER
IRON ROD/PIPE FOUND
PROJECT
LOCATION
LEGEND
G
ST
S
T
W
EXISTING CONTOUR
EXISTING CURB
EXISTING GAS
EXISTING STORM
EXISTING GRAVITY SEWER
EXISTING TELEPHONE
EXISTING SEWER MANHOLE
EXISTING STORM MANHOLE
EXISTING CATCH BASIN
EXISTING HYDRANT
EXISTING SHUT OFF
EXISTING UTILITY POLE
EXISTING LIGHT POLE
EXISTING GUY WIRE/POLE
EXISTING SIGN
EXISTING DECIDUOUS TREE
EXISTING CONIFEROUS TREE
EDGE OF BRUSH/WOODS
APPROXIMATE SETBACK LINE
APPROXIMATE PROPERTY LINE
S
D
T EXISTING TELEPHONE MANHOLE
ZONING REQUIREMENTS:
COVERAGE
CATEGORY
LOT BUILDING
ZONING EXISTING
SETBACK
ZONING DISTRICT: COMMERCIAL 1 / RESIDENTIAL 12 *
FRONT YARD 15'±
PARCEL - MULTIFAMILY
SIDE YARD
REAR YARD
40%
60%
30'
10'
30'
LOT COVERAGE
17.4%
57.3%
13'±
10'±
* RESIDENTIAL 12 ZONING REGULATIONS UTILIZED
3,500 S.F / UNIT
(MAX. 12 UNITS PER AC.)
57,279 S.F.
(12 UNITS)
PROPOSED
15'±
17.6%
57.8%
13'±
10'±
57,279 S.F.
(10 UNITS)
1.UTILITIES SHOWN DO NOT PURPORT TO CONSTITUTE OR REPRESENT ALL UTILITIES
LOCATED UPON OR ADJACENT TO THE SURVEYED PREMISES. EXISTING UTILITY LOCATIONS
ARE APPROXIMATE ONLY. THE CONTRACTOR SHALL FIELD VERIFY ALL UTILITY CONFLICTS.
ALL DISCREPANCIES SHALL BE REPORTED TO THE ENGINEER. THE CONTRACTOR SHALL
CONTACT DIG SAFE (888-344-7233) PRIOR TO ANY CONSTRUCTION. IN ADDITION, THE
CONTRACTOR SHALL HIRE A PRIVATE UTILITY LOCATING FIRM TO LOCATE OWNER OWNED
UNDERGROUND UTILITIES PRIOR TO START OF ANY EXCAVATION.
2.ALL EXISTING UTILITIES NOT INCORPORATED INTO THE FINAL DESIGN SHALL BE REMOVED
OR ABANDONED AS INDICATED ON THE PLANS OR DIRECTED BY THE ENGINEER.
3.THE CONTRACTOR SHALL MAINTAIN AS-BUILT PLANS (WITH TIES) FOR ALL UNDERGROUND
UTILITIES. THOSE PLANS SHALL BE SUBMITTED TO THE OWNER AT THE COMPLETION OF
THE PROJECT.
4.THE CONTRACTOR SHALL REPAIR/RESTORE ALL DISTURBED AREAS (ON OR OFF THE SITE)
AS A DIRECT OR INDIRECT RESULT OF THE CONSTRUCTION.
5.ALL GRASSED AREAS SHALL BE MAINTAINED UNTIL FULL VEGETATION IS ESTABLISHED.
6.MAINTAIN ALL TREES OUTSIDE OF CONSTRUCTION LIMITS.
7.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL WORK NECESSARY FOR COMPLETE
AND OPERABLE FACILITIES AND UTILITIES.
8.THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR ALL ITEMS AND MATERIALS
INCORPORATED INTO THE SITE WORK. WORK SHALL NOT BEGIN ON ANY ITEM UNTIL SHOP
DRAWING APPROVAL IS GRANTED.
9.IN ADDITION TO THE REQUIREMENTS SET IN THESE PLANS AND SPECIFICATIONS, THE
CONTRACTOR SHALL COMPLETE THE WORK IN ACCORDANCE WITH ALL PERMIT
CONDITIONS AND ANY LOCAL PUBLIC WORKS STANDARDS.
10.THE TOLERANCE FOR FINISH GRADES FOR ALL PAVEMENT, WALKWAYS AND LAWN AREAS
SHALL BE 0.1 FEET. UNLESS NOTED OTHERWISE, ALL EXISTING MANHOLE COVERS, VALVES,
CURB STOPS AND OTHER ITEMS TO REMAIN SHALL BE ADJUSTED TO THE NEW FINISH
GRADE.
11.ANY DEWATERING NECESSARY FOR THE COMPLETION OF THE SITEWORK SHALL BE
CONSIDERED AS PART OF THE CONTRACT AND SHALL BE THE CONTRACTOR'S
RESPONSIBILITY.
12.THE CONTRACTOR SHALL COORDINATE ALL WORK WITHIN TOWN ROAD R.O.W. WITH TOWN
AUTHORITIES.
13.THE CONTRACTOR SHALL INSTALL THE ELECTRICAL, CABLE AND TELEPHONE SERVICES IN
ACCORDANCE WITH THE UTILITY COMPANIES REQUIREMENTS.
14.EXISTING PAVEMENT AND TREE STUMPS TO BE REMOVED SHALL BE DISPOSED OF AT AN
APPROVED OFF-SITE LOCATION. ALL PAVEMENT CUTS SHALL BE MADE WITH A PAVEMENT
SAW.
15.IF THERE ARE ANY CONFLICTS OR INCONSISTENCIES WITH THE PLANS OR SPECIFICATIONS,
THE CONTRACTOR SHALL CONTACT THE ENGINEER FOR VERIFICATION BEFORE WORK
CONTINUES ON THE ITEM IN QUESTION.
16.PROPERTY LINE INFORMATION IS APPROXIMATE AND BASED ON EXISTING TAX MAP
INFORMATION. THIS PLAN IS NOT A BOUNDARY SURVEY AND IS NOT INTENDED TO BE USED
AS ONE.
17.IF THE BUILDING IS TO BE SPRINKLERED, BACKFLOW PREVENTION SHALL BE PROVIDED IN
ACCORDANCE WITH AWWA M14. THE SITE CONTRACTOR SHALL CONSTRUCT THE WATER
LINE TO TWO FEET ABOVE THE FINISHED FLOOR. SEE MECHANICAL PLANS FOR RISER
DETAIL.
18.THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING TESTING AND INSPECTION SERVICES
INDICATED IN THE CONTRACT DOCUMENTS, TYPICAL FOR CONCRETE AND SOIL TESTING.
19.THE CONTRACTOR IS RESPONSIBLE FOR ALL LAYOUT AND FIELD ENGINEERING REQUIRED
FOR COMPLETION OF THE PROJECT. CIVIL ENGINEERING ASSOCIATES WILL PROVIDE AN
AUTOCAD FILE WHERE APPLICABLE.
20.THE OWNER SHALL BE RESPONSIBLE FOR THE INSTALLATION OF ANY AND ALL SAFETY
FENCES OR RAILS ABOVE EXISTING AND PROPOSED WALLS. THE OWNER SHALL VERIFY
LOCAL, STATE AND INSURANCE REQUIREMENT GUIDELINES FOR THE INSTALLATION AND
VERIFY ANY AND ALL PERMITTING REQUIREMENTS.
GENERAL NOTES
12/14/22 DSM REVISED PER CLIENT COMMENTS
P:\AutoCADD Projects\2022\22141-Champlain Housing Trust\1-CADD Files-22141\dwg\22141 - Site.dwg, 12/15/2022 7:57:37 AM, DWG To PDF.pc3
DSM
DSM
MAB
AS SHOWN
22141
C3.0
04/29/2022
LOCATION MAP
1" = 2000'
CHAMPLAIN
HOUSING TRUST,
INC.
1660 WILLISTON ROAD
SOUTH BURLINGTON
VERMONT 05403
"HO HUM MOTEL"
PROPERTY
SITE DETAILS
A
C
CIVIL ENGINEERING ASSOCIATES, INC.
E
10 MANSFIELD VIEW LANE, SOUTH BURLINGTON, VT 05403
P: 802-864-2323 FAX: 802-864-2271 web: www.cea-vt.com
1660 WILLISTON ROAD
SOUTH BURLINGTON, VT
116
2
PROJECT
LOCATION
REVISED 8/9/2015M-015aM-015a Bike rackOR APPROVED EQUAL
22"1 7/8"36"N.T.S.
BIKE RACK (PARK-IT BIKE RACKS)
REVISED 10/21/2019M-016M-016 BIKE RACK (PLAN VIEW)30"CL TO CL OF HOOP24" MIN.24" MIN.7.5'7.5'30" MIN.30" MIN.
N.T.S.
BIKE RACK (PLAN VIEW)
CONC. PAD
SEE BIKE
RACK DETAIL
PROJECT COORDINATION
PART 1 - GENERAL
1.01 MEETINGS & PROJECT ACCESS
A.The Owner shall be notified five (5) days prior to commencement of Work by the
Contractor.
B.The Contractor will coordinate with the Owner to arrange an on-site pre-construction
meeting prior to commencement of any work. Job superintendents and subcontractors shall
be included in this meeting.
C.The Contractor will coordinate all phases of the Work, so as not to interfere with the
normal work procedures in the area.
D.The Contractor shall conduct his work in such a manner as to not interfere with or
endanger work or traffic in areas adjacent to the construction area, except as permitted by the
Owner. The Contractor shall so arrange his construction operations as to provide access for
emergency vehicles and equipment to the work site at all times.
1.02 LABOR
A.The Contractor and subcontractors will employ mechanics skilled in their respective
trades.
B.All labor will be performed in a neat and workmanlike manner.
1.03 PROTECTION OF PERSONS AND PROPERTY
A.The Contractor shall be responsible for initiating, maintaining, and supervising all
O.S.H.A. safety precautions in connection with the Work.
B.Fire Protection: The Contractor shall take all necessary precautions to prevent fires
adjacent to the Work and shall provide adequate facilities for extinguishing fires. The
Contractor shall also prevent fires in project related buildings and shall prevent the spread of
fires to areas outside the limits of the Work.
C.Safety Precautions: Prior to commencement of Work, the Contractor shall be familiar
with all safety regulations and practices applicable with construction operations. No
additional payments will be made for equipment and procedures necessitated by these safety
precautions.
1.04 CORRECTION OF WORK
A.The Contractor shall promptly correct all Work rejected by the Owner as defective or as
failing to conform to the Contract Documents. The Contractor shall bear all cost of correcting
such rejected Work.
1.05 WEATHER CONDITIONS
A.No Work shall be done when, in the opinion of the Owner, the weather is unsuitable.
No concrete, earth backfill, embankment, or paving shall be placed upon frozen material. If
there is delay or interruption in the Work due to weather conditions, the necessary
precautions must be taken to bond new Work to old.
B.Protection Against Water and Storm: The Contractor shall take all precautions to
prevent damage to the Work by storms or by water entering the site of the Work directly or
through the ground. In case of damage by storm or water, the Contractor, at his own
expense, shall make repairs or replacements or rebuild such parts of the Work as the
Engineer may require in order that the finished work may be completed as required by the
Drawings and Specifications.
1.06 DISPOSAL OF DEBRIS
A.All debris and excess materials, other than that which is authorized to be reused,
become the property of the Contractor and shall be promptly removed from the property. The
Contractor shall receive title to all debris and/or excess material. The Owner will not be
responsible for any loss or damage to debris or excess material owned by the Contractor.
1.07 PROJECT LAYOUT
A.The Contractor shall be responsible for providing all necessary survey staking.
1.Locate and protect control points before starting work on the site.
2.Preserve permanent reference points during progress of the Work.
3.Establish a minimum of two permanent benchmarks on the site, referenced to data
established by survey control points.
a.Record locations, with horizontal and vertical data, on Project Record Documents.
1.08 TESTING
A.The Contractor is responsible for obtaining testing and inspection services.
24'-0" CONC. SLAB
23'-0"9'-0"4'-6"10'-0" CONC. SLAB9'-9"9'-9"
6" BOLLARD
(TYP.)4"x6" P.T.
POST (TYP.)
3'-6"
3'-6"
TYP
2'-6"
TYP
8'-0" OPENING 8'-0" OPENING
3'-0"
OPENING
FRONT ELEVATION
4"x6" P.T.
POST (TYP.)
FLUSH BOLTS
SCREEN BOARD OR
OTHER MAT'L. AS PER
OWNERS REQUEST
6" CRUSHED GRAVEL
AT BOTTOM OF POST
CONCRETE
FILL AROUND
POST
6" CONCRETE PAD
8" CRUSHED GRAVEL
12" GALV. CARRIAGE
BOLTS OR 34"x412" LONG
GALV. LAG BOLTS
BAR LATCH &
BRACKETS W.
PAD LOCK @
TOP LATCH4'-6"6"6"6'-0"HEAVY DUTY
TEE HINGE,
STANLEY
#CD1291 OR
APPROVED
EQUAL
2"x6" P.T. GIRTS (TYP.)
5' SQ AREA NOT TO
EXCEED 2% GRADE
5' DIA AREA NOT TO
EXCEED 2% GRADE
ACCESSIBILITY
TURNAROUND
DUMPSTER SLIDING ACCESS
DOOR TO FACE ACCESSIBILITY
AREA BETWEEN DUMPSTERS
DUMPSTER ENCLOSURE - ADA
N.T.S.
09/07/2022
PLAN
M-010ADET-010A DUMPSTER09/08/22 DSM REVISED DETAILS
CONFIRM AND COORDINATE
FENCE AND GATE REQUIREMENTS
WITH FENCE MANUFACTURER.
DETAIL REFLECTS MINIMUM
REQUIREMENTS FOR WOOD
ENCLOSURE FENCE.P:\AutoCADD Projects\2022\22141-Champlain Housing Trust\1-CADD Files-22141\dwg\22141 - Site.dwg, 9/8/2022 9:13:46 AM, DWG To PDF.pc3
DSM
DSM
MAB
NONE
22141
C4.0
04/29/2022
LOCATION MAP
1" = 2000'
CHAMPLAIN
HOUSING TRUST,
INC.
1660 WILLISTON ROAD
SOUTH BURLINGTON
VERMONT 05403
"HO HUM MOTEL"
PROPERTY
LANDSCAPE
REFERENCES AND
DETAILS
PROJECT
LOCATION
A
C
CIVIL ENGINEERING ASSOCIATES, INC.
E
10 MANSFIELD VIEW LANE, SOUTH BURLINGTON, VT 05403
P: 802-864-2323 FAX: 802-864-2271 web: www.cea-vt.com
1660 WILLISTON ROAD
SOUTH BURLINGTON, VT
116
2
GAZABO LIKENESS
PROPOSED PLANTINGS
STEEL STAT OUTDOOR PARK BENCH
LOCKABLE BIKE RACK
N.T.S.
GAZEBO PAD
12"
6" 1.5" MINUS CRUSED
STONE BASE
UNDISTURBED SOIL OR
APPROVED COMPACTED
GRANULAR FILL
SEPARATION FABRIC
12"
EDGE OF GAZEBO
09/08/22 DSM REVISED DETAILS
P:\AutoCADD Projects\2022\22141-Champlain Housing Trust\1-CADD Files-22141\dwg\22141 - Site.dwg, 9/8/2022 9:14:08 AM, DWG To PDF.pc3
UP
UP
GUEST RM GUEST RMGUEST RM ACCESSIBLE
GUEST RM
GUEST RM
GUEST RM
GUEST RM
GUEST RM
ACCESSIBLE
GUEST RM
MECHANICAL
LAUNDRY
2a
1a
1a
NOTE:
DEMO ALL BATHROOM FIXTURES,
PRESERVE PLUMBING ROUGH-IN UNO.
TYPICAL
2a
1a 1a
EXIST RAMP DOWN
1
1
1a
1
2
NOTE:
REMOVE ALL FURNITURE
2a
DN
DN
STORAGE
GUEST RMGUEST RMGUEST RMGUEST RM
GUEST RM
GUEST RM
GUEST RM
GUEST RM
STORAGE
2
3
3
NOTE:
DEMO ALL BATHROOM FIXTURES,
PRESERVE PLUMBING ROUGH-IN UNO.
TYPICAL
33
1a
1
1a
1a
1a
1a
NOTE:
REMOVE ALL FURNITURE
DEMOLITION LEGEND
1 DEMOLISH WALL
2 DEMOLISH DOOR AND FRAME
3 DEMOLISH BATHROOM FIXTURE
PRESERVE PLUMBING ROUGH IN
2a DEMOLISH DOOR AND FRAME,
ENLARGE OPENING, COORD W/ PLAN
1a DEMOLISH OPENING IN WALL
FOR NEW DOOR AND FRAME,
COORD W/ PLAN
3a
DEMOLISH BATHROOM FIXTURE
RECONFIGURE PLUMBING
ROUGH IN PER KITCHEN LAYOUT
1
1a
3 3a
1
21a
1a
1
3 3a
2a
project name:sheet title:
sheet no.
scale:
project no.
checked by:
drawn by:
proj. date:
sheet date:project address:P802.879.51537 CARMICHAEL ST. ESSEX JUNCTION, VT 05452SCOTTPARTNERS.COMF802.872.27641/8" = 1'-0"12/21/2022 11:42:00AMS:\1-S+P-Projects\4-MULTI-FAMILY-HOUSING\CHT - Ho Hum Motel\Drawings\Revit\Ho Hum Motel_back building.rvtHO HUM MOTEL21-1452
JRP
JLG
12/21/22
DEMOLITION
PLANS -BACK
BUILDING
A1.1BID / CONSTRUCTION SET 12/21/22 Enter address here-
1/8" = 1'-0"1 FIRST FLOOR DEMOLITION PLAN 1/8" = 1'-0"2 SECOND FLOOR DEMOLITION PLAN
1/8" = 1'-0"3 ALTERNATE DEMO PLAN FOR UNITS 12,14,16,17,19 & 20
1/8" = 1'-0"4 ALTERNATE DEMOLITION PLAN FOR UNITS 11 & 15
No Date Revisions
REF.REF.REF.REF.REF.REF.REF.REF.REF.
REF.REF.A3.13
A3.0
A3.1 2
1
A3.03
A3.0 2
APT #3
1-BR UNIT
370 SF
APT #2
1-BR UNIT
574 SF
APT #4
1-BR UNIT
535 SF
APT #5
1-BR UNIT
405 SF
APT #1
2-BR UNIT
800 SF
APT #8
1-BR UNIT
370 SFAPT #6
1-BR UNIT
405 SF
APT #7
1-BR UNIT
520 SF
CRAWL
SPACE
ACCESS
STAIR
APT #9
1-BR UNIT
405 SF
APT #10
1-BR UNIT
405 SF
BASEMENT
ACCESS
BUILDING FOOTPRINT = 5,620 SF
BUILDING
STORAGE
REPLACE ALL BATHROOM FIXTURES & ACCESSORIES, TYP.
REPLACE EXISTING KITCHEN CABINETS,
COUNTERS & APPLIANCES, TYPICAL
A8.2
8
A8.2
13
A8.3
5
A8.2
8
A8.2
8
PROVIDE 4' - 4" (VIF) OF NEW
BASE AND WALL CABINETS,
AND COUNTERTOP
PROVIDE NEW 2'-0" BASE CABINET
WHERE DISHWASHER WAS
REMOVED, MATCH EXISTING
A8.2
8
OPPHOPPHA8.2
8A8.2
13
OPPH
FE
FE FE
FE
FE
FE
A8.0
5
FE
FE
A8.2
8
OPPH 102105 106 107
109110FE
FE
104
A8.0
1
A8.0
3
A8.0
5
A8.2
8
A8.2
8
A8.2
8
A8.0
1
A8.2
8
A8.2
8
OPPH
A8.2
8
OPPH
A8.2
8
A8.0
3
A8.0
3
OPPH
OPPH
A8.2
8
OPPH
A8.0
1
A8.0
1
OPPH
INFILL WALLS WHERE DOORS AND FRAMES
WERE DEMOLISHED, MATCH EXISTING,
ADJACENT, 1 HR RATED CONSTRUCTION.
INFILL OPENING, MATCH
EXISTING, ADJACENT, 1 HR
RATED CONSTRUCTION
IN-FILL EXISTING
FLOOR OPENING TO
MATCH EXISTING
ADJACENT
CONSTRUCTION,
TYPICAL
CRAWL SPACE ACCESS
002
003
GENERAL NOTE:
ASSUMED EXISTING FIRE RATED BARRIER- ENSURE
COMPLETENESS OF BARRIER. WALLS MUST EXTEND TO
UNDERSIDE OF DECKING, OR WALLS MUST CONNECT TO
A RATED CEILING ASSEMBLY, WITH FIRE CAULKING
ALONG ALL PERIMETER EDGES, PENETRATIONS, ETC....
CRAWL SPACE ACCESS
PROVIDE WALL & DOOR TO
ENCLOSE 2ND BEDROOM
001
INFILL WALL -MATCH
EXISTING ADJACENT
A8.3
10
001a101OFFICE
001
2
1
1
1
TYP.
UNO
1
1
1
4
A3.0
CRAWL
SPACE
SLAB
ON
GRADE
MECHANICAL /
ELECTRICAL
BASEMENT FOOTPRINT = 890 SF
CRAWL
SPACE
CRAWL SPACE
CRAWL
SPACE
CRAWL SPACE
ACCESS
CRAWL SPACE
ACCESS
CRAWL SPACE
ACCESS
PROVIDE VAPOR BARRIER OVER
GROUND & UP INTERIOR FACE OF
FROST WALLS - SEE SCHEMATIC
SECTION ON A3.0
PROVIDE SPRAY FOAM ALONG RIM
JOISTS, TYPICAL -
SEE SCHEMATIC SECTION ON A3.0
1' 5'10' 20'40'
SCALE: 1/8" = 1' -0"
A8.0
3
OPPH
A8.2
8
NEW 34"x80" DOORS
VERTICAL BIKE STORAGE
RACKS, 4 BIKE CAPACITY EACH
-B.O.D: GLOBAL INDUSTRIES
MODEL T9F670513, LOCKABLEMIN13' - 6"MIN5' - 0"PROVIDE INSULATED
DOOR IN EXISTING R.O.
PROVIDE INSULATED
DOOR IN EXISTING R.O.
PROVIDE WINDOW
IN EXISTING R.O.
PROVIDE WINDOW
IN EXISTING R.O.
BIKE
STORAGE
BUILDING
STORAGE
PROVIDE BLOCKING
FOR BIKE RACKS
004
005
project name:sheet title:
sheet no.
scale:
project no.
checked by:
drawn by:
proj. date:
sheet date:project address:P802.879.51537 CARMICHAEL ST. ESSEX JUNCTION, VT 05452SCOTTPARTNERS.COMF802.872.2764As indicated
12/21/2022 11:47:35AMS:\1-S+P-Projects\4-MULTI-FAMILY-HOUSING\CHT - Ho Hum Motel\Drawings\Revit\Ho Hum Motel_front building.rvtHO HUM MOTEL21-1452
JRP
JLG
12/21/22
FLOOR PLANS -
FRONT BUILDING
A2.0BID / CONSTRUCTION SET 12/20/22 Enter address here-
1/8" = 1'-0"1 PROPOSED FIRST FLOOR PLAN
1/16" = 1'-0"2 PROPOSED BASEMENT PLAN
1/8" = 1'-0"3 ALTERNATE PLAN FOR UNITS 1,2,5 & 6
1/8" = 1'-0"4 GARAGE PLAN
No Date Revisions
WDWDWDREF.REF.REF.
REF.
REF.REF.REF.
REF.
REF.REF.REF.REF.APT #15
ACCESSIBLE
1-BR UNIT
580 SF
APT #14
1-BR UNIT
580 SF
MECHANICAL
APT #13
1-BR UNIT
290 SF
APT #12
1-BR UNIT
585 SF
LAUNDRY
UP
UP
APT #11
ACCESSIBLE
1-BR UNIT
580 SF
EXIST RAMP DOWN
REPLACE ALL BATHROOM
FIXTURES & ACCESSORIES, TYP.
A8.4
1
A8.4
1
A8.4
6
A8.4
6
OPPH
A8.4
12
A8.4
6
NEW 36" ENTRY DOOR SLOPE DN 1:20SLOPE TOP
FLUSH W/
WALKWAY
EXISTING SLOPE DN4' - 0"
EXISTING
CONCRETE
WALKWAY
EXISTING
SLOPE DN EXISTING
STEP DOWN
4' - 0"SLOPE DN 1:20115a 115b114a
111a
112a
A8 0
3
A8.4
6
A8.4
6
OPPH
OPPH
A8.4
6
A8.4
6
OPPH
A8.1
1
A8 0
3
OPPH
002
111b
A8 0
3
113aOPPH
A8.1
1
OPPH
TOP LANDING
FLUSH W/
WALKWAY
BOTTOM FLUSH
W/ PAVEMENT
BOTTOM FLUSH
W/ PAVEMENT
NEW SLOPED WALKWAY
NEW SLOPED WALKWAY
GENERAL NOTE:
ASSUMED EXISTING FIRE RATED BARRIER- ENSURE
COMPLETENESS OF BARRIER. WALLS MUST EXTEND TO
UNDERSIDE OF DECKING, OR WALLS MUST CONNECT TO
A RATED CEILING ASSEMBLY, WITH FIRE CAULKING
ALONG ALL PERIMETER EDGES, PENETRATIONS, ETC....
CRAWL SPACE
ACCESS STAIR
5
A3.2
2
TYP
UNO
ONE SIDED
PARTITIONS
AT SHOWERS
APT #20
1-BR UNIT
630 SF
STORAGE
APT #19
1-BR UNIT
630 SF
APT #17
1-BR UNIT
630 SF
STORAGE
APT #16
1-BR UNIT
630 SF
DN
DN
REPLACE ALL BATHROOM
FIXTURES & ACCESSORIES, TYP.
A8.4
6
OPPH
A8.4
6
A8.4
6
OPP
A8.4
6
A8.4
6
A8.4
6
OPPH
A8.4
6
A8.1
3
A8.4
6
OPP
OPPH
A8.4
6
A8.4
6
APT #18
1-BR UNIT
770 SF
216a
217a
218a
219a 220a
A8.1
3
OPPH
A8.1
3
OPPH
A8.1
3
A8.1
3
OPPH
5
A3.2
A8.1
3
NEW 34" x 80"
TYPE 2 DOORS
NEW BATHROOM
FIXTURES &
ACCESSORIES
INFILL BETWEEN
EXISTING WALLS
TO MATCH
CONNECT NEW SINK
TO RECONFIGURED
EXISTING PLUMBING
A8.4
6
SIMILAR
PROVIDE 2x5 (CLEAR)
CLOSET W/ CASED
OPENING AND
CLOSET ROD & SHELF
A8.1
1 A8.4
1
OPPH
NEW 36" x 80"
TYPE 2 DOORS
NEW BATHROOM
FIXTURES &
ACCESSORIES
CONNECT NEW SINK
TO RECONFIGURED
EXISTING PLUMBING
SLAB
ON
GRADE
SLAB
ON
GRADE
CRAWL
SPACE
CRAWL
SPACE
CRAWL SPACE ACCESS STAIR
PROVIDE VAPOR BARRIER OVER
GROUND & UP INTERIOR FACE OF
FROST WALLS - SEE SCHEMATIC
SECTION ON A3.2
PROVIDE SPRAY FOAM ALONG RIM
JOISTS, TYPICAL -
SEE SCHEMATIC SECTION ON A3.2 project name:sheet title:
sheet no.
scale:
project no.
checked by:
drawn by:
proj. date:
sheet date:project address:P802.879.51537 CARMICHAEL ST. ESSEX JUNCTION, VT 05452SCOTTPARTNERS.COMF802.872.2764As indicated
12/21/2022 11:42:02AMS:\1-S+P-Projects\4-MULTI-FAMILY-HOUSING\CHT - Ho Hum Motel\Drawings\Revit\Ho Hum Motel_back building.rvtHO HUM MOTEL21-1452
JRP
JLG
12/21/22
FLOOR PLANS -
BACK BUILDING
A2.1BID / CONSTRUCTION SET 12/21/22 Enter address here-
1/8" = 1'-0"1 FIRST FLOOR PLAN - PROPOSED
1/8" = 1'-0"2 SECOND FLOOR PLAN - PROPOSED
1/8" = 1'-0"4 ALTERNATE PLAN FOR UNITS 12,14,16,17,19 & 20
1/8" = 1'-0"3 ALTERNATE PLAN FOR UNITS 11 & 15
1/16" = 1'-0"5 CRAWL SPACE PLAN
No Date Revisions
FIRST FLOOR
0"
BASEMENT
-8' -0"
EXISTING EXTERIOR WALLS, ROOF,
DOORS AND WINDOWS TO REMAIN,
UNO, TYPICAL
4
A3.0
FIRST FLOOR
0"
BASEMENT
-8' -0"
INFLL SIDING AT
REMOVED DOOR
DOOR & SIDELIGHTS WHERE
EXISTING DOUBLE DOOR REMOVED
LOWER FIRST
FLOOR
-1' -2"
A3.0
4
FIRST FLOOR
0"
FIRST FLOOR
0"
PROVIDE SPRAY FOAM
ALONG RIM JOISTS
PROVIDE VAPOR BARRIER
OVER GROUND & UP
INTERIOR FACE OF FROST
WALLS
EXISTING CEILING
EXISTING ORIGINAL ROOF STRUCTURE -
INSPECT TO CONFIRM INTACT WITH NO
HOLES, GAPS, PENETRATIONS, ETC. -
SERVING AS AIR BARRIER
EXISTING ROOF OVERBUILD
EXISTING CAVITY INSULATION
BLOWN-IN CELLULOSE
INSULATION
EXISTING RIDGE VENT
WORK SCOPE AT EAVES:
1. REMOVE VENTED VINYL SOFFIT TO
ACCESS ORIGINAL ROOF STRUCTURE
2. REMOVE SOFFIT TRIM FROM ORIGINAL
SOFFIT EXTENSION TO EXPOSE JOIST
CAVITY
3. SPRAY FOAM SEAL RAFTER CAVITY
AFTER BLOCKING ORIGINAL JOIST AREA
4. INSTALL BAFFLE AT NEW RAFTER -
ALIGN W/ EXTERIOR WALL
5. INSTALL BLOWN-IN CELLULOSE
INSULATION IN ATTIC (R-60)
6. REINSTALL VENTED VINYL SOFFIT project name:sheet title:
sheet no.
scale:
project no.
checked by:
drawn by:
proj. date:
sheet date:project address:P802.879.51537 CARMICHAEL ST. ESSEX JUNCTION, VT 05452SCOTTPARTNERS.COMF802.872.2764As indicated
12/21/2022 11:47:36AMS:\1-S+P-Projects\4-MULTI-FAMILY-HOUSING\CHT - Ho Hum Motel\Drawings\Revit\Ho Hum Motel_front building.rvtHO HUM MOTEL21-1452
JRP
JLG
12/21/22
EXT. ELEVATIONS
& SCHEMATIC
SECTION -FRONT
BUILDING
A3.0BID / CONSTRUCTION SET 12/20/22 Enter address here-
1/8" = 1'-0"1 SOUTH ELEVATION
1/8" = 1'-0"3 EAST ELEVATION 1
1/8" = 1'-0"2 WEST ELEVATION 1
1/4" = 1'-0"4 SCHEMATIC BUILDING SECTION
No Date Revisions
FIRST FLOOR
0"
ROOF
9' -4"
EXISTING EXTERIOR WALLS, ROOF,
DOORS AND WINDOWS TO REMAIN,
UNO, TYPICAL
4
A3.0
FIRST FLOOR
0"
ROOF
9' -4"
BASEMENT
-8' -0"
ACCESS DOOR TO
BASEMENT CRAWL SPACE
FIRST FLOOR
0"
ROOF
9' -4"
BASEMENT
-8' -0"
ACCESS DOOR TO
BASEMENT CRAWL SPACE
project name:sheet title:
sheet no.
scale:
project no.
checked by:
drawn by:
proj. date:
sheet date:project address:P802.879.51537 CARMICHAEL ST. ESSEX JUNCTION, VT 05452SCOTTPARTNERS.COMF802.872.27641/8" = 1'-0"12/21/2022 11:47:38AMS:\1-S+P-Projects\4-MULTI-FAMILY-HOUSING\CHT - Ho Hum Motel\Drawings\Revit\Ho Hum Motel_front building.rvtHO HUM MOTEL21-1452
JRP
JLG
12/21/22
EXTERIOR
ELEVATIONS -
FRONT BUILDING
A3.1BID / CONSTRUCTION SET 12/20/22 Enter address here-
1/8" = 1'-0"1 NORTH ELEVATION
1/8" = 1'-0"2 WEST ELEVATION 2
1/8" = 1'-0"3 EAST ELEVATION 2
No Date Revisions
FIRST FLOOR
0"
SECOND FLOOR
10' -0"
ROOF
19' -0"
5
A3.2
INFILL SIDING WHERE DOOR
REMOVED -MATCH ADJACENT
FIRST FLOOR
0"
SECOND FLOOR
10' -0"
ROOF
19' -0"
REPLACE ENTRY DOOR
TO NEW LAUNDRY ROOM
FIRST FLOOR
0"
SECOND FLOOR
10' -0"
ROOF
19' -0"
EXISTING EXTERIOR WALLS, ROOF,
DOORS AND WINDOWS TO REMAIN,
UNO, TYPICAL
5
A3.2
FIRST FLOOR
0"
SECOND FLOOR
10' -0"
ROOF
19' -0"
PROVIDE VAPOR BARRIER
OVER GROUND & UP INTERIOR
FACE OF FROST WALLS
PROVIDE SPRAY FOAM
ALONG RIM JOISTS, TYP.
SCOPE AT 2ND FLOOR OVERHANG:
1. DEMO PLYWOOD CEILING TO ACCESS JOIST CAVITIES
2. FILL EACH JOIST CAVITY WITH SPRAY FOAM INSULATION
3. REPLACE PLYWOOD CEILING - MATCH EXISTING FINISH
EXISTING CAVITY INSULATION, TYP.
EXISTING ROOF TRUSS
EXISTING ORIGINAL ROOF FRAMING
EXISTING 2ND FLOOR OVERBUILD
EXISTING CEILING FRAMING
GRAWL SPACE
EXISTING RIDGE VENT
EXISTING VENT BAFFLE
EXISTING BATT INSULATION
TO BE REMOVED
SCOPE AT EAVES:
1. REMOVE VENTED SOFFIT (PLYWOOD CEILING AT FRONT)
2. PROVIDE BAFFLE AT TOP OF WALL, BETWEEN EACH
TRUSS, TO CONTAIN INSULATION
NOTE: MAINTAIN INTEGRITY OF VENT BAFFLE, PROVIDE
AS NEEDED
3. PROVIDE 1" SPRAY FOAM OVER CEILING -TO SERVE AS
AIR BARRIER (METHOD CAN BE DISCUSSED)
4. PROVIDE BLOWN-IN CELLULOSE INSULATION (R-60)
5. REPLACE VENTED SOFFIT / PLYWOOD CEILING
project name:sheet title:
sheet no.
scale:
project no.
checked by:
drawn by:
proj. date:
sheet date:project address:P802.879.51537 CARMICHAEL ST. ESSEX JUNCTION, VT 05452SCOTTPARTNERS.COMF802.872.2764As indicated
12/21/2022 11:42:05AMS:\1-S+P-Projects\4-MULTI-FAMILY-HOUSING\CHT - Ho Hum Motel\Drawings\Revit\Ho Hum Motel_back building.rvtHO HUM MOTEL21-1452
JRP
JLG
12/21/22
EXT. ELEVATIONS
& SCHEMATIC
SECTION -BACK
BUILDING
A3.2BID / CONSTRUCTION SET 12/21/22 Enter address here-
1/8" = 1'-0"3 North
1/8" = 1'-0"1 East
1/8" = 1'-0"2 South
1/8" = 1'-0"4 West
1/4" = 1'-0"5 SCHEMATIC BUILDING SECTION
No Date Revisions
REF.REF.
PLAM WALL CABINETS
PLAM COUNTERTOP
PLAM BASE CABINETS
RANGE, OFCI
RANGE HOOD
LIGHT VALANCE
EXISTING GWB WALL
4
A9.0
6
A9.0
SIM, BASE
PER
SIM, BASE
PER /8 A9.0 /8 A9.0
2" FILLER
2' - 6"
1" END PNL
2' - 0"
1" END PNL
2' - 6"
2" FILLER
3"2' - 6"2' - 0"2' - 6"3"
1" END PANELS
6
A9.0
4
A9.0
RANGE HOOD
LIGHT VALANCE
1"2' - 6"1"
RANGE
2' - 0"1"2' - 6"
1"
REF
2' - 9"
/8 A9.0
SIM, BASE
PER /8 A9.0
WALL MOUNTED
FIRE EXTINGUISHER
WALL BASE
REMOVABLE PLAM
BASE CABINET
1" END PANELS
PLAM WALL CABINETS
REMOVABLE PLAM
SINK BASE CABINET
RANGE, OFCI
1" END PANELS
REFRIGERATOR, OFCI
EXISTING GWB WALL
SIM, BASE
PER
2' - 6"2' - 0"2' - 6"2' - 11"
LINE OF WALL
3' - 0"1' - 6"2' - 6"NEW GWB WALLS
EXISTING GWB WALLS
REFRIGERATOR,
OFCI
WALL BASE 3' - 0"1' - 6"2' - 6"A8.0
2
WALL MOUNTED
FIRE EXTINGUISHER
RANGE, OFCI
7' - 4"
WALL MOUNTED
FIRE EXTINGUISHER
PLAM WALL CABINETS
PLAM COUNTERTOP
REMOVABLE PLAM
SINK BASE CABINET
RANGE, OFCI
RANGE HOOD
EXISTING GWB WALL
WALL BASE 2' - 6"1' - 6"3' - 0"1"
2' - 6"
1"
2' - 0"
1"
2' - 6"
1"
LIGHT VALANCE
REMOVABLE PLAM
BASE CABINET
1" END PANELS 1" END PANELS
6
A9.0
4
A9.0
SIM, BASE
PER
SIM, BASE
PER/8 A9.0 /8 A9.0
A8.04
WALL MOUNTED
FIRE EXTINGUISHER
RANGE, OFCI 10' - 1"REFRIGERATOR,
OFCI
A8.06
7
WALL MOUNTED
FIRE EXTINGUISHER
EXISTING, VIF7' - 6"project name:sheet title:
sheet no.
scale:
project no.
checked by:
drawn by:
proj. date:
sheet date:project address:P802.879.51537 CARMICHAEL ST. ESSEX JUNCTION, VT 05452SCOTTPARTNERS.COMF802.872.27641/2" = 1'-0"12/21/2022 11:47:39AMS:\1-S+P-Projects\4-MULTI-FAMILY-HOUSING\CHT - Ho Hum Motel\Drawings\Revit\Ho Hum Motel_front building.rvtHO HUM MOTEL21-1452
JRP
JLG
12/21/22
ENLARGED
PLANS AND
INTERIOR
ELEVATIONS
A8.0BID / CONSTRUCTION SET 12/20/22 Enter address here-
1/2" = 1'-0"6 ADAPTABLE KITCHEN TYPE C ELEVATION 1
1/2" = 1'-0"4 ADAPTABLE KITCHEN TYPE B ELEVATION
NOTE:
WHERE EVER POSSIBLE, REUSE EXISTING PLUMBING AND
ELECTRICAL. IN BATHROOMS, NEW FIXTURES WILL BE
LOCATED WHERE EXISTING FIXTURES WHERE REMOVED.
1/2" = 1'-0"7 ADAPTABLE KITCHEN TYPE C ELEVATION 2
1/2" = 1'-0"1 ADAPTABLE KITCHEN TYPE A PLAN
1/2" = 1'-0"2 ADAPTABLE KITCHEN TYPE A ELEVATION
1/2" = 1'-0"3 ADAPTABLE KITCHEN TYPE B PLAN
1/2" = 1'-0"5 ADAPTABLE KITCHEN TYPE C PLAN
No Date Revisions
REF.REF.A8.1 2
2' - 10"REFRIGERATIOR, OFCI
CLEAR KNEE SPACE
RANGE, OFCI
PLAM APRON
CLEAR KNEE SPACE W/
ANGLED PLAM PANEL
PLAM APRON
PLAM WALL CABINETS
PLAM BASE CABINET
RANGE HOOD
2' - 9"
1" END PNL
2' - 6" CLR
1" END PNL
2' - 0"
1" END PNL
3' - 0" CLR 1' - 0"
2' - 11"2' - 6"2' - 0"
WALL BASE
7
A9.0
5
A9.0 SIM
FIRE EXTINGUISHER1' - 3"A8.1 4
2' - 9"2' - 6"2' - 0"2' - 6"2' - 6"1' - 6"3' - 0"RANGE HOOD
LIGHT VALANCE
REFRIGERATOR,
OFCI
WALL BASERANGE, OFCI
PLAM WALL CABINETS
PLAM BASE CABINETS
FIRE EXTINGUISHER
project name:sheet title:
sheet no.
scale:
project no.
checked by:
drawn by:
proj. date:
sheet date:project address:P802.879.51537 CARMICHAEL ST. ESSEX JUNCTION, VT 05452SCOTTPARTNERS.COMF802.872.27641/2" = 1'-0"12/21/2022 11:42:05AMS:\1-S+P-Projects\4-MULTI-FAMILY-HOUSING\CHT - Ho Hum Motel\Drawings\Revit\Ho Hum Motel_back building.rvtHO HUM MOTEL21-1452
JRP
JLG
12/21/22
ENLARGED
PLANS AND
INTERIOR
ELEVATIONS
A8.1BID / CONSTRUCTION SET 12/21/22 Enter address here-
1/2" = 1'-0"1 ACCESSIBLE KITCHEN PLAN
1/2" = 1'-0"2 ACCESSIBLE KITCHEN ELEVATION
1/2" = 1'-0"3 VISITABLE KITCHEN PLAN
1/2" = 1'-0"4 VISITABLE KITCHEN ELEVATION
No Date Revisions
A8.2
7
4
5
6
A8.2
9
10
11
12
SURFACE
MOUNT
MEDICINE
CABINET
EXISTING WALLS
EXISTING DOOR
COORINATE
LOCATION OF
NEW TOILET
WITH EXISTING
PLUMBING
SURFACE MOUNTED
MIRRORED MEDICINE
CABINET, CENTER ON SINK
SINK W/ INSULATED
PIPING
TOILET
WALL BASE
EXISTING GWB WALL
VANITY LIGHT
EXISTING WINDOW
& TRIM
EXISTING GWB WALL
TOILET
TP HOLDER
WALL BASE
TUB / SHOWER UNIT
TOWEL BAR
3' - 6"TUB / SHOWER UNIT
ROBE HOOK
MEDICINE CABINET
WALL MOUNTED SINK
SHOWER
CURTAIN ROD
EQ EQ
5' - 0"DOOR IN OPEN
POSITION
EXISTING GWB WALL
EXISTING WINDOW & TRIM
TP HOLDER
SINK W/ INSULATED
PIPING
WALL BASE
TOWEL RODSURFACE MOUNTED
MIRRORED MEDICINE
CABINET, CENTER ON
SINK
VANITY LIGHT
3' - 6"ROBE HOOK
TUB / SHOWER UNIT
WALL BASE
SHOWER
CURTAIN ROD
EQEQ
5' - 0"DOOR IN OPEN
POSITION
project name:sheet title:
sheet no.
scale:
project no.
checked by:
drawn by:
proj. date:
sheet date:project address:P802.879.51537 CARMICHAEL ST. ESSEX JUNCTION, VT 05452SCOTTPARTNERS.COMF802.872.27641/2" = 1'-0"12/21/2022 11:47:40AMS:\1-S+P-Projects\4-MULTI-FAMILY-HOUSING\CHT - Ho Hum Motel\Drawings\Revit\Ho Hum Motel_front building.rvtHO HUM MOTEL21-1452
JRP
JLG
12/21/22
ENLARGED
PLANS AND
INTERIOR
ELEVATIONS
A8.2BID / CONSTRUCTION SET 12/20/22 Enter address here-
1/2" = 1'-0"8 TYPE A BATHROOM PLAN
1/2" = 1'-0"13 TYPE B BATHROOM PLAN
1/2" = 1'-0"7 TYPE A BATHROOM ELEVATION 4
1/2" = 1'-0"4 TYPE A BATHROOM ELEVATION 1
1/2" = 1'-0"5 TYPE A BATHROOM ELEVATION 2
1/2" = 1'-0"6 TYPE A BATHROOM ELEVATION 3
1/2" = 1'-0"9 TYPE B BATHROOM ELEVATION 1
1/2" = 1'-0"10 TYPE B BATHROOM ELEVATION 2
1/2" = 1'-0"11 TYPE B BATHROOM ELEVATION 3
1/2" = 1'-0"12 TYPE B BATHROOM ELEVATION 4
NOTE:
WHERE EVER POSSIBLE, REUSE EXISTING PLUMBING AND
ELECTRICAL. IN BATHROOMS, NEW FIXTURES WILL BE
LOCATED WHERE EXISTING FIXTURES WHERE REMOVED.
No Date Revisions
A8.3
1
2
3
4
EXISTING GWB WALLS
ROBE HOOK
TUB / SHOWER UNIT
TP HOLDER
TOILET
WALL BASE
DOOR IN OPEN POSITION
EQ EQ
5' - 0"SINK W/ INSULATED
PIPING
WALL BASE
TUB/ SHOWER UNIT
EXISTING GWB WALL
TOWEL BAR
SURFACE MOUNTED
MEDICINE CABINET,
CENTER ON SINK
SHOWER CURTAIN ROD
3' - 6"VANITY LIGHT
WALL BASE
EXISTING WINDOW
REPLACE WD
TRIM W/ PVC TRIM
A8.3
8
6
79
7' - 6" MIN CLEAR
6' - 5" MIN CLEAR4"(MIN 48")± 4' - 6" CLEARCLR
2' - 0"
CLOSET ROD
& SHELF
LINE OF CONCRETE
WALL BELOW -T.O.W.
APPROX 1'-2" AFF
EXIST CONC WALL -
CARRY DRYWALL
DOWN TO FLOOR2' - 10"3' - 0"3' - 4" MAX2' - 0"
1' - 6"
1' - 0"
3' - 0"3' - 0"ADD ALTERNATE: ACT
CEILING AT 8' AFF
VANITY LIGHT
MIRROR
ADA FAUCET
ADA SINK W/
INSULATED PIPING
TOILET -FLUSH
CONTROLS TO BE ON
THE SINK SIDE
GRAB BAR -PROVIDE
SOLID BLOCKING
BEHIND
WALL BASE
DOOR IN OPEN
POSITION
DOOR STOP
WALL BASE
EQEQ
4' - 0"ROBE HOOK
WALL BASE
EXIST CONC WALL -
CARRY DRYWALL
DOWN TO FLOOR 3' - 0"WD TRIM
GRAB BAR -PROVIDE
SOLID BLOCKING
BEHIND
TOILET
WALL BASE
TOILET PAPER
DISPENSER8"2' - 0"project name:sheet title:
sheet no.
scale:
project no.
checked by:
drawn by:
proj. date:
sheet date:project address:P802.879.51537 CARMICHAEL ST. ESSEX JUNCTION, VT 05452SCOTTPARTNERS.COMF802.872.27641/2" = 1'-0"12/21/2022 11:47:41AMS:\1-S+P-Projects\4-MULTI-FAMILY-HOUSING\CHT - Ho Hum Motel\Drawings\Revit\Ho Hum Motel_front building.rvtHO HUM MOTEL21-1452
JRP
JLG
12/21/22
ENLARGED
PLANS AND
INTERIOR
ELEVATIONS
A8.3BID / CONSTRUCTION SET 12/20/22 Enter address here-
1/2" = 1'-0"5 TYPE C BATHROOM PLAN
1/2" = 1'-0"1 TYPE C BATHROOM ELEVATION 1
1/2" = 1'-0"2 TYPE C BATHROOM ELEVATION 2
1/2" = 1'-0"3 TYPE C BATHROOM ELEVATION 3
1/2" = 1'-0"4 TYPE C BATHROOM ELEVATION 4
1/2" = 1'-0"10 OFFICE BATHROOM PLAN
No Date Revisions
A8.4 5
2
3
4
ADA TOILET
GRAB BARS ON
3 SIDES OF
SHOWER UNIT
ADA SINK RELOCATE EXISTING
DOOR - INFILL WALL
ADA ROLL-IN
SHOWER UNITTP HOLDER
GRAB BARS
NEW WALL FOR
DEEPER ADA
SHOWER UNIT
GRAB BAR
TOWEL BAR
ADA SHOWER
CONTROLS
2' MIN
ADA ROLL-IN SHOWER UNIT W/
ADJUSTABLE SHOWER HEAD
(PROVIDE REMOVABLE BENCH)
BLOCKING AND GRAB BAR
SHOWER CURTAIN ROD
DOOR STOP
DOOR IN OPEN POSITION
ROBE HOOK
SURFACE
MOUNTED
MEDICINE
CABINET
4' - 0"ADA SINK W/
INSULATED
PIPING
EQEQ
3' - 4"EXISTING
GWB WALLS
GRAB BAR
BLOCKING FOR
GRAB BAR
WALL BASE
ADA TOILET -
FLUSH
CONTROLS TO
BE ON THE
SINK SIDE3' - 0"3' - 4" MAX2' - 10"3' - 0"1' - 0"
3' - 0"
1' - 6"1' - 6"
2' - 0"
VANITY LIGHT
MIRROR
EXISTING
GWB WALL
GRAB BAR
TOILET PAPER HOLDER
WALL BASE
BLOCKING FOR
GRAB BAR
GRAB BAR AS
TOWEL BAR
4' - 6"
1' - 0"3' - 0"4' - 0"2' - 0"
8"2' - 0"PROVIDE REDUCER STRIP OR
FEATHER FLOORING UNDERLAYMENT
TO PROVIDE ADA COMPLIANT
THRESHOLD -COORD W/ SHOWER
MODEL
SHOWER
CURTAIN ROD
A8.4
11
10
9
8
EXISTING
EXTERIOR WALL
TOILET
MIRRORED MEDICINE CABINETTUB/
SHOWER
UNIT
A8.4
7
TP HOLDER
EXISTING CLOSET
ROD & SHELF
EXISTING CEILING
EXISTING WALL
TUB / SHOWER
UNIT
SHOWER
CURTAIN ROD
ROBE HOOK
4' - 0"EQ EQ
WALL BASE
TOILET
EXISTING CEILING
EXISTING WALL
TUB/ SHOWER UNIT
SHOWER CURTAIN ROD
TOILET PAPER
HOLDER
DOOR STOP
DOOR IN OPEN
POSITION
SURFACE MOUNTED
MEDICINE CABINET,
CENTER ON SINK
PLAM COUNTER W/
INTEGRAL
BACKSPLASH
WD VALANCE
TOILET
EXISTING
EXTERIOR WALL
EXISTING
INTERIOR WALLS
SINK
TP HOLDER
TOWEL BAR
A8.4
15
A8.4
13
16 14
TOILET
TP HOLDER
SINK W/ INSULATED
PIPING
SURFACE MOUNTED
MEDICINE CABINET,
CENTER ON SINK
WALL BASE
EXISTING WALL
CHANGE IN PLANE
VANITY LIGHT
TOWEL ROD
3' - 6"TUB / SHOWER UNIT
DOOR STOP
SHOWER
CURTAIN ROD
DOOR IN OPEN
POSITION
ROBE HOOK
EXISTING WALL
WALL BASE
EQEQ
5' - 0"project name:sheet title:
sheet no.
scale:
project no.
checked by:
drawn by:
proj. date:
sheet date:project address:P802.879.51537 CARMICHAEL ST. ESSEX JUNCTION, VT 05452SCOTTPARTNERS.COMF802.872.27641/2" = 1'-0"12/21/2022 11:42:07AMS:\1-S+P-Projects\4-MULTI-FAMILY-HOUSING\CHT - Ho Hum Motel\Drawings\Revit\Ho Hum Motel_back building.rvtHO HUM MOTEL21-1452
JRP
JLG
12/21/22
ENLARGED
PLANS AND
INTERIOR
ELEVATIONS
A8.4BID / CONSTRUCTION SET 12/21/22 Enter address here-
1/2" = 1'-0"1 ACCESSIBLE BATHROOM PLAN
1/2" = 1'-0"5 ACCESSIBLE BATHROOM ELEVATION 1
1/2" = 1'-0"4 ACCESSIBLE BATHROOM ELEVATION 2
1/2" = 1'-0"3 ACCESSIBLE BATHROOM ELEVATION 3
1/2" = 1'-0"2 ACCESSIBLE BATHROOM ELEVATION 4
1/2" = 1'-0"6 TYPE F BATHROOM PLAN
1/2" = 1'-0"11 TYPE F BATHROOM ELEVATION 1
1/2" = 1'-0"10 TYPE F BATHROOM ELEVATION 2
1/2" = 1'-0"9 TYPE F BATHROOM ELEVATION 3
1/2" = 1'-0"8 TYPE F BATHROOM ELEVATION 4
1/2" = 1'-0"7 TYPE F BATHROOM ELEVATION 5
1/2" = 1'-0"12 TYPE G BATHROOM PLAN
1/2" = 1'-0"16 TYPE G BATHROOM ELEVATION 1
1/2" = 1'-0"15 TYPE G BATHROOM ELEVATION 2
1/2" = 1'-0"14 TYPE G BATHROOM ELEVATION 3
1/2" = 1'-0"13 TYPE G BATHROOM ELEVATION 4
No Date Revisions
VARIES - SEE ELEVATIONSVARRIES - SEE ELEVATIONSWALL BASE
2x4 WD BLOCKING
ADJ. SHELVING, TYP.
DOOR PULL
STEEL DRAWER SLIDES
DRAWER PULL
RADIUS COUNTER
EDGES
COUTNERTOP +
BACKSPLASH
4"2' - 1"
TYP.
1' - 0"
DOOR PULL
ADJ. SHELVING 2' - 6"TYPICAL TO TOP OF CABINETS7' - 0"DOOR FRONTS
DOOR FRONT1' - 3"4"WOOD VALANCE
UNDER CABINET LED STRIP
TYPICAL TO TOP OF CABINETS7' - 0"4" WALL BASE
CASEWORK BEYOND
1x COUNTER
SUPPORT LEDGER
INSULATED PIPING
DROP IN SINK
SKIRT BOARD
COUNTER TOP +
BACKSPLASH
RADIUS COUNTER
EDGES
1' - 2"REMOVABLE PANEL
POST + CLIP 5 1/2"2' - 3"1 1/2"1"
BLOCKING AS REQ'D
9"11"
8"
HATCHED AREA =
REQURIED ADA KNEE &
TOE CLEARANCE BELOW
COUNTER 2' - 10"4"WALL BASE
HATCHED AREA =
REQURIED ADA
KNEE & TOE
CLEARANCE BELOW
COUNTER
RADIUS EDGES
COUTNERTOP W/
BACKSPLASH
4"2' - 10"2' - 1"2' - 3" MIN7" MAXAPRON
DROP IN SINK
2' - 1"COUNTER TOP &
BACKSPLASH 1 1/2"3' - 0"4"WALL BASE
2x4 WD BLOCKING
DOOR FRONTS
DOOR PULL 1' - 3"4"WOOD VALANCE
UNDER CABINET LED STRIP
DOOR FRONT
DOOR PULL
WALL CABINET
NOTE:
WALL CABINETS NOT REQUIRED
WHERE SINK IS UNDER A WINDOW
7' - 0"H.C. UNITS 54" MAX. A.F.F. FOR SIDE APPROACH CLOSETSNOTES:
1. CLOSETS WIDER THAN 48" INSIDEPROVIDE SHELF
AND CLOSET ROD BRACKETS
2. PROVIDE SUBITTAL FOR SHELVING SYSTEMS
3. PROVIDE BLOCKING
VINYL COATED OPEN MESH
CLOSET SHELVING SYSTEM
INSTALL PER MFG.
INSTRUCTIONS
H.C. UNITS 48" MAX. A.F.F. FOR FRONT APPROACH CLOSETS1' - 2"5' - 8" AFF, TYP.NOTES:
1. CLOSETS WIDER THAN 48" INSIDE
PROVIDE SHELF AND CLOSET ROD
BRACKETS
2. PROVIDE SUBMITTAL FOR SHELVING
SYSTEMS
3. PROVIDE BLOCKING
VINYL COATED OPEN MESH
CLOSET SHELVING SYSTEM
INSTALL PER MFG.
INSTRUCTIONS
1' - 3" MIN.1' - 0"1' - 0"9"1' - 2"4' - 0" MAX.NOTES:
1. CLOSETS WIDER THAN 48" INSIDE PROVIDE SHELF
AND CLOSET ROD BRACKETS
2. PROVIDE SUBMITTAL FOR SHELVING SYSTEMS
3. PROVIDE BLOCKING
VINYL COATED OPEN MESH
CLOSET SHELVING SYSTEM
INSTALL PER MFG.
INSTRUCTIONS
1' - 4"1' - 2"1' - 0"1' - 0"1' - 0"1' - 2"
COUNTERTOP
& BACKSPLASH
3" SUPPORT MATCH
CABINET FINISHES
REMOVABLE CABINET
FACADE MATCH ADJACENT
CABINET FINISHES
3/4" MDO PLYWD
REMOVABLE BASE
REMOVABLE
BLOCKINGREMOVABLE
FINISHED BASE
METAL CORNER BRACKET
NOTES:
1. ALL FINISHES TO EXTEND UNDER CABINET SO AS TO CREATE A FINISHED
ENTITY WHEN CABINET IS REMOVED.
2. PROVIDE AND INSTALL WOOD SUPPORT BRACKET IN VANITY CABINETS.
LOCATION TO BE COORDINATED IN THE SHOP DRAWINGS.
PAINTED DRYWALL 4"VARIES - SEE ELEVATIONS2' - 1"project name:sheet title:
sheet no.
scale:
project no.
checked by:
drawn by:
proj. date:
sheet date:project address:P802.879.51537 CARMICHAEL ST. ESSEX JUNCTION, VT 05452SCOTTPARTNERS.COMF802.872.27641 1/2" = 1'-0"12/21/2022 11:47:41AMS:\1-S+P-Projects\4-MULTI-FAMILY-HOUSING\CHT - Ho Hum Motel\Drawings\Revit\Ho Hum Motel_front building.rvtHO HUM MOTEL21-1452
JRP
JLG
12/21/22
INTERIOR
DETAILS
A9.0BID / CONSTRUCTION SET 12/20/22 Enter address here-
1 1/2" = 1'-0"6 TYPICAL BASE AND UPPER CABINETS
1 1/2" = 1'-0"5 ACCESSIBLE SINK BASE CABINET
1 1/2" = 1'-0"7 OPEN WORKSPACE
1 1/2" = 1'-0"4 TYPICAL SINK BASE CABINET
1 1/2" = 1'-0"1 CLOSET SHELVING - TYPICAL SINGLE SHELF + ROD
1 1/2" = 1'-0"2 CLOSET SHELVING - ACCESSIBLE MULTIPLE SHELF CLOSETS
1 1/2" = 1'-0"3 CLOSET SHELVING - TYPICAL MULTIPLE SHELF CLOSETS
1 1/2" = 1'-0"8 KNOCK DOWN BASE CABINET
No Date Revisions
DOOR TYPES
PER SCHEDULE
PER SCHEDULE2
FLUSH (F)
1
6-PANEL (6P)
6"6"
PER SCHEDULE
6"8"PER SCHEDULE3
FULL GLASS (FG)
PER SCHEDULE
PER SCHEDULEproject name:sheet title:
sheet no.
scale:
project no.
checked by:
drawn by:
proj. date:
sheet date:project address:P802.879.51537 CARMICHAEL ST. ESSEX JUNCTION, VT 05452SCOTTPARTNERS.COMF802.872.2764As indicated
12/21/2022 11:47:42AMS:\1-S+P-Projects\4-MULTI-FAMILY-HOUSING\CHT - Ho Hum Motel\Drawings\Revit\Ho Hum Motel_front building.rvtHO HUM MOTEL21-1452
JRP
JLG
12/21/22
DOOR
SCHEDULES
A11.0BID / CONSTRUCTION SET 12/20/22 Enter address here-
DOOR SCHEDULE
LOCATION DOOR
RATING HDWR SET REMARKSDOOR No. TYP MAT'L WIDTH HEIGHT THK Glazing
001 3 FIBERGLASS 3' - 0" 6' - 8" 1 3/4" FG N/A ENTRY MATCH EXISTING DOOR HEIGHT; PROVIDE CLOSER, WEATHERSTRIPPING & ADA
THERMALLY BROKEN THRESHOLD
001a 2 WD 3' - 0" 6' - 8" 1 3/8" - N/A PRIVACY PROVIDE CLOSER
002 1 FIBERGLASS 3' - 0" 6' - 8" 1 3/4" - N/A STOREROOM PROVIDE CLOSER, WEATHERSTRIPPING & THERMALLY BROKEN THRESHOLD
003 1 FIBERGLASS 3' - 0" 6' - 8" 1 3/4" - N/A STOREROOM PROVIDE CLOSER, WEATHERSTRIPPING & THERMALLY BROKEN THRESHOLD
004 3 FIBERGLASS 3' - 0" 6' - 8" 1 3/4" - N/A STOREROOM PROVIDE CLOSER, WEATHERSTRIPPING & ADA THERMALLY BROKEN THRESHOLD
005 2 FIBERGLASS 3' - 0" 6' - 8" 1 3/4" - N/A STOREROOM PROVIDE CLOSER, WEATHERSTRIPPING & ADA THERMALLY BROKEN THRESHOLD
101 2 WD 2' - 6" 6' - 8" 1 3/8" - N/A PASSAGE MAXIMIZE DOOR WIDTH IN AVAILABLE OPENING
102 2 WD 3' - 0" 6' - 8" 1 3/8" - N/A PASSAGE
104 2 WD 3' - 0" 6' - 8" 1 3/8" - N/A PASSAGE
105 2 WD 3' - 0" 6' - 8" 1 3/8" - N/A PASSAGE
106 2 WD 3' - 0" 6' - 8" 1 3/8" - N/A PASSAGE
107 2 WD 3' - 0" 6' - 8" 1 3/8" - N/A PASSAGE
109 2 WD 3' - 0" 6' - 8" 1 3/8" - N/A PASSAGE
110 2 WD 3' - 0" 6' - 8" 1 3/8" - N/A PASSAGE
- FRONT BUILDING
- BACK BUILDING
No Date Revisions