Loading...
HomeMy WebLinkAboutPermit Permanent Sign SN-22-43 - JoAnnInternally Illuminated LED 48” Joann 87.58 Type: Illumination: Square Footage: SIGN A Individual Front-Lit channel ltrs/ Raceway Joann 45 Hinesberg Rd Burlington, VT 05408 128906 Dan Murphy Kirk Forster 07/21/2022 Project ID#: Project Mgr: Designer: Created on: R1 07/29/22 MD Corrected elevation scale, increased sign A to 42” R2 08/04/22 KF - Modified Sign A to 48”, added UC Sign to package R3 08/05/22 KF - Updated Front Elevation to encompass second UC sign 1 Willisto n R d 45 Hinesberg Road South Burlington, VT 05408 Midas DrRte 1163/16” White Pan-formed face w/ first surface applied Vinyl 4.00Square Footage: Joann - Replacement Face Type: SIGN B SIGN B SIGN A 3/16” White Pan-formed face w/ first surface applied Vinyl 4.00Square Footage: Joann - Replacement Face Type: SIGN C SIGN C 10’-0”4’-0”21’-0”48"EQ EQ 80’-0” Lease Dimension 21’-10 3/4” UC Sign B Existing Joann 45 Hinesberg Rd Burlington, VT 05408 128906 Dan Murphy Kirk Forster 07/21/2022 Project ID#: Project Mgr: Designer: Created on: R1 07/29/22 MD Corrected elevation scale, increased sign A to 42” R2 08/04/22 KF - Modified Sign A to 48”, added UC Sign to package R3 08/05/22 KF - Updated Front Elevation to encompass second UC sign 2 Allowable Square Footage this Elevation:252.00 Actual Square Footage this Elevation:91.58 Front Elevation (North) Scale: 1/8” = 1’-0" NOTE: DRAWING IS FOR REPRESENTATIONAL PURPOSES ONLY. EXACT DIMENSIONS (FIELD SURVEY) REQUIRED PRIOR TO FABRICATION Formula: 21’ x 80’ x .15 = 252.00 SqFt Allowed Internally Illuminated LED 48” Joann 87.58 Type: Illumination: Square Footage: SIGN A Individual Front-Lit channel ltrs/ Raceway 3/16” White Pan-formed face w/ first surface applied Vinyl 4.00Square Footage: Joann - Replacement Face Type: SIGN B UC Sign C 3/16” White Pan-formed face w/ first surface applied Vinyl 4.00Square Footage: Joann - Replacement Face Type: SIGN C 1. Existing Facade: Corrugated Metal Fascia 2. 0.040” Aluminum letter returns pre-painted white 3. 1”Jewelite trimcap (white) bonded to face and #8 pan head screws to returns. Note: 2” trimcaps for letters 54” and larger .125” ACM backs (pre-finished white) fastened to returns. Seal w/ VOC compliant 4. 360 white latex caulk to prevent moisture penetration. 5. White LED’s 6. 3/16” #7328 White Acrylic faces 7. Disconnect switch UL Outdoor rated toggle type w/ neoprene boot per NEC 600-6 8. Primary electrical feed in UL conduit / customer supplied UL junction box 9. Power Supplies 10. Low profile extruded aluminum raceway (7” x 4 1/2”) w/ watertight cover. All painted to match PMS #376 Green if on green painted facade. 11. 2” Aluminum mounting clips, Maximum 6” from each end and every 48” o.c. (TYP) 12. Rivets, 3/16” aluminum #66 (letter to raceway fastening) Thru bolt attachment for large letters. 13. Mounting hardware to suit 14. 1/8” Aluminum Backer Panel, ptm PMS 376C Green 15. Studs & Silicone mounting to corrugated Metal fascia Specifications: 5”4 1/2” 1 2 4 5 6 3 12 ¼” Drain holes at bottom of letter cans w/ light baffles. For exterior signage only 8 13 9 11 7 10 14 15 Joann 45 Hinesberg Rd Burlington, VT 05408 128906 Dan Murphy Kirk Forster 07/21/2022 Project ID#: Project Mgr: Designer: Created on: R1 07/29/22 MD Corrected elevation scale, increased sign A to 42” R2 08/04/22 KF - Modified Sign A to 48”, added UC Sign to package R3 08/05/22 KF - Updated Front Elevation to encompass second UC sign 3 White LEDs (X) 60w Power Supplies Total Amps: X.XX (1) 20 amp 120V Circuit Req. Electrical Detail: General Notes: This sign is to be installed in accordance with the requirements of Article 600 of the National Electrical Code. - Grounded and bonded per NEC 600.7/NEC 250 - Existing branch circuit in compliance with NEC 600.5, not to exceed 20 amps - Sign is to be UL listed per NEC 600.3 - UL disconnect switch per NEC 600.6- required per sign component before leaving manufacturer. For multiple signs, a disconnect is permitted but not required for each section - The location of the disconnect switch after installa- tion shall comply with article 600.6 (A) (1) per NEC Internally Illuminated LED 48” Joann 87.58 Type: Illumination: Square Footage: SIGN A Individual Front-Lit channel ltrs/ Raceway Scale: 1/4" = 1'-0" Sign Layout Detail48”[262 3/4”]21’-10 3/4” Joann 45 Hinesberg Rd Burlington, VT 05408 128906 Dan Murphy Kirk Forster 07/21/2022 Project ID#: Project Mgr: Designer: Created on: R1 07/29/22 MD Corrected elevation scale, increased sign A to 42” R2 08/04/22 KF - Modified Sign A to 48”, added UC Sign to package R3 08/05/22 KF - Updated Front Elevation to encompass second UC sign 4 Proposed Existing D/F Under Canopy Sign TBD Scale: 1” = 1’-0” 11 "TBDTBDSpecifications: 1. Existing Facade: TBD 2. EXISTING Aluminum sign cabinet 3. Pre-Molded 3/16” White acrylic faces with first surface applied Vinyl to match PMS #376 Green 4. Sign cabinet contains lamps, ballasts, and raceways 5. Waterproof disconnect switch 6. Primary electrical feed 7. Mounting hardware to suit 1 6 2 3 4 5 7 3/16” White Pan-formed face w/ first surface applied Vinyl 4.00Square Footage: Joann - Replacement Face Type: SIGN B A.F.F. (TBD)Side View Scale: 1” = 1’-0” TBD 3/16” White Pan-formed face w/ first surface applied Vinyl 4.00Square Footage: Joann - Replacement Face Type: SIGN C