HomeMy WebLinkAboutPermit Permanent Sign SN-22-43 - JoAnnInternally Illuminated LED
48” Joann
87.58
Type:
Illumination:
Square Footage:
SIGN A
Individual Front-Lit channel ltrs/ Raceway
Joann
45 Hinesberg Rd
Burlington, VT 05408
128906
Dan Murphy
Kirk Forster
07/21/2022
Project ID#:
Project Mgr:
Designer:
Created on:
R1 07/29/22 MD Corrected elevation scale, increased sign A to 42”
R2 08/04/22 KF - Modified Sign A to 48”, added UC Sign to package
R3 08/05/22 KF - Updated Front Elevation to encompass second UC sign
1
Willisto
n
R
d
45 Hinesberg Road South Burlington, VT 05408
Midas DrRte 1163/16” White Pan-formed face w/ first
surface applied Vinyl
4.00Square Footage:
Joann - Replacement Face
Type:
SIGN B
SIGN B
SIGN A
3/16” White Pan-formed face w/ first
surface applied Vinyl
4.00Square Footage:
Joann - Replacement Face
Type:
SIGN C
SIGN C
10’-0”4’-0”21’-0”48"EQ EQ
80’-0” Lease Dimension
21’-10 3/4”
UC Sign B
Existing
Joann
45 Hinesberg Rd
Burlington, VT 05408
128906
Dan Murphy
Kirk Forster
07/21/2022
Project ID#:
Project Mgr:
Designer:
Created on:
R1 07/29/22 MD Corrected elevation scale, increased sign A to 42”
R2 08/04/22 KF - Modified Sign A to 48”, added UC Sign to package
R3 08/05/22 KF - Updated Front Elevation to encompass second UC sign
2
Allowable Square Footage this Elevation:252.00
Actual Square Footage this Elevation:91.58
Front Elevation (North)
Scale: 1/8” = 1’-0"
NOTE: DRAWING IS FOR REPRESENTATIONAL
PURPOSES ONLY. EXACT DIMENSIONS (FIELD
SURVEY) REQUIRED PRIOR TO FABRICATION
Formula: 21’ x 80’ x .15 = 252.00 SqFt Allowed
Internally Illuminated LED
48” Joann
87.58
Type:
Illumination:
Square Footage:
SIGN A
Individual Front-Lit channel ltrs/ Raceway 3/16” White Pan-formed face w/ first
surface applied Vinyl
4.00Square Footage:
Joann - Replacement Face
Type:
SIGN B
UC Sign C
3/16” White Pan-formed face w/ first
surface applied Vinyl
4.00Square Footage:
Joann - Replacement Face
Type:
SIGN C
1. Existing Facade: Corrugated Metal Fascia
2. 0.040” Aluminum letter returns pre-painted white
3. 1”Jewelite trimcap (white) bonded to face and #8 pan head screws to returns.
Note: 2” trimcaps for letters 54” and larger
.125” ACM backs (pre-finished white) fastened to returns. Seal w/ VOC compliant 4.
360 white latex caulk to prevent moisture penetration.
5. White LED’s
6. 3/16” #7328 White Acrylic faces
7. Disconnect switch UL Outdoor rated toggle type w/ neoprene boot per NEC 600-6
8. Primary electrical feed in UL conduit / customer supplied UL junction box
9. Power Supplies
10. Low profile extruded aluminum raceway (7” x 4 1/2”) w/ watertight cover. All painted to
match PMS #376 Green if on green painted facade.
11. 2” Aluminum mounting clips, Maximum 6” from each end and every 48” o.c. (TYP)
12. Rivets, 3/16” aluminum #66 (letter to raceway fastening) Thru bolt attachment for large letters.
13. Mounting hardware to suit
14. 1/8” Aluminum Backer Panel, ptm PMS 376C Green
15. Studs & Silicone mounting to corrugated Metal fascia
Specifications:
5”4 1/2”
1
2
4
5
6
3
12
¼” Drain holes at bottom
of letter cans w/ light baffles.
For exterior signage only
8
13
9 11
7
10
14
15
Joann
45 Hinesberg Rd
Burlington, VT 05408
128906
Dan Murphy
Kirk Forster
07/21/2022
Project ID#:
Project Mgr:
Designer:
Created on:
R1 07/29/22 MD Corrected elevation scale, increased sign A to 42”
R2 08/04/22 KF - Modified Sign A to 48”, added UC Sign to package
R3 08/05/22 KF - Updated Front Elevation to encompass second UC sign
3
White LEDs
(X) 60w Power Supplies
Total Amps: X.XX
(1) 20 amp 120V Circuit Req.
Electrical Detail:
General Notes:
This sign is to be installed in accordance with
the requirements of Article 600 of the National
Electrical Code.
- Grounded and bonded per NEC 600.7/NEC 250
- Existing branch circuit in compliance with
NEC 600.5, not to exceed 20 amps
- Sign is to be UL listed per NEC 600.3
- UL disconnect switch per NEC 600.6- required per
sign component before leaving manufacturer. For
multiple signs, a disconnect is permitted but not
required for each section
- The location of the disconnect switch after installa-
tion shall comply with article 600.6 (A) (1) per NEC
Internally Illuminated LED
48” Joann
87.58
Type:
Illumination:
Square Footage:
SIGN A
Individual Front-Lit channel ltrs/ Raceway
Scale: 1/4" = 1'-0"
Sign Layout Detail48”[262 3/4”]21’-10 3/4”
Joann
45 Hinesberg Rd
Burlington, VT 05408
128906
Dan Murphy
Kirk Forster
07/21/2022
Project ID#:
Project Mgr:
Designer:
Created on:
R1 07/29/22 MD Corrected elevation scale, increased sign A to 42”
R2 08/04/22 KF - Modified Sign A to 48”, added UC Sign to package
R3 08/05/22 KF - Updated Front Elevation to encompass second UC sign
4
Proposed
Existing
D/F Under Canopy Sign
TBD
Scale: 1” = 1’-0”
11 "TBDTBDSpecifications:
1. Existing Facade: TBD
2. EXISTING Aluminum sign cabinet
3. Pre-Molded 3/16” White acrylic faces with first surface applied
Vinyl to match PMS #376 Green
4. Sign cabinet contains lamps, ballasts, and raceways
5. Waterproof disconnect switch
6. Primary electrical feed
7. Mounting hardware to suit
1
6
2
3
4
5
7
3/16” White Pan-formed face w/ first
surface applied Vinyl
4.00Square Footage:
Joann - Replacement Face
Type:
SIGN B A.F.F. (TBD)Side View
Scale: 1” = 1’-0”
TBD
3/16” White Pan-formed face w/ first
surface applied Vinyl
4.00Square Footage:
Joann - Replacement Face
Type:
SIGN C