Loading...
HomeMy WebLinkAboutZP-22-390 - 1068 Williston Road 9/27/2022EXISTING 8x8 TEE 8" GATE VALVE CONSTRUCTED 6" DI WATER SERVICE. 6" GATE VALVE 8"x6" REDUCER WILLISTON ROADTO I-89 LIMITS OF FUTURE RIGHT OF WAY EXISTING PROPERTY LINE SNOW STORAGE AREA SNOW STORAGE AREA PROPOSED 7'x12.5' TRANSFORMER PAD LOCATION (K30.3 VAULT). CONTRACTOR TO COORDINATE WITH GMP AND ELECTRICAL PLANS PROPOSED 4'X10' GENERATOR PAD PROPOSED 8'x15' TRANSFORMER PAD LOCATION (K30.6 VAULT). CONTRACTOR TO COORDINATE WITH GMP AND ELECTRICAL PLANS PROPOSED 7'x12.5' TRANSFORMER PAD LOCATION (K30.3 VAULT). CONTRACTOR TO COORDINATE WITH GMP AND ELECTRICAL PLANS BEGIN TEMPORARY 6" BITUMINOUS CURB END CONCRETE CURB PEDESTRIAN PUSH BUTTON PEDESTAL. LOCATION AND WIRING TO BE COORDINATED WITH ENGINEER AND SOUTH BURLINGTON DPW PRIMARY BUILDING FACADE12' PLAZA STONE DRIP EDGE 8' WIDE MULTI-USE PATH PEDESTRIAN PUSH BUTTON AND SIGNAL HEAD TO BE MOUNTED ON PROPOSED SIGNAL POLE. COORDINATE FINAL LOCATION AND WIRING WITH ENGINEER AND SOUTH BURLINGTON DPW. SIGNAL POLE AND FOUNDATION BY OTHERS. PERGOLA PERGOLA 18.0' 9.0' 24.0'18.0'3.66'4.50'16 13 10 23 23 22 12 8 2 3 LA LA LA SECONDARY STREET FRONTAGE=91.6'27' PRIMARY STREET FRONTAGE=192.3' BUILDING FRONTAGE =165.4' PROPOSED FUTURE CITY STREET LA LA LA LA 36' PROPOSED CONCRETE DUMPSTER PAD. SEE DETAIL, SHEET C7.2.BUILDING FRONTAGE=88.2'LA TOTAL GSF = 59,815 SF FFE = 313.95' TOTAL GSF = 83,927 SF HOLIDAY INN FFE = 314.5' (RENOVATION OF EXISTING BUILDING) PROPOSED LOBBY ADDITION PRIMARY BUILDING FACADE SECONDARY BUILDING FACADESECONDARY STREET BUILD TO ZONEPRIMARY BUILD TO ZONE 12'HAMPTON INN FLUSH CURB AT ISLAND 13 9.0'18.0' TOTAL GSF = 136,561 SF FFE = 313.9' MULTI-FAMILY BUILDING PROPOSED POOL ADDITION BUILDING FRONTAGE =79'PRIMARY STREET FRONTAGE =136'LA LA LA LA LA LA LA LA LA LA 2 5.6' WOOD GUARDRAIL RELOCATED CHAIN LINK FENCE FUTURE PHASE 2A 2B 3 EXISTING PROPERTY LINE LIMITS OF FUTURE ROW LIMITS OF PHASE 2A LIMITS OF PHASE 2B of Project Number Sheet Drawing Number Drawing Title Issued for Checked byDesigned by Appvd.DateRevisionNo.vhb.comDate 40 IDX Drive, Building 100 Suite 200 South Burlington, VT 05403 Holiday Inn Redevelopment 1068 Williston Rd. South Burlington, Vermont Review Not Approved For Construction July 29, 2021 27 57913.01 Proposed Site Plan C2.01 2 CHS PBS Feet6030015 Parking Summary Chart Description Spaces Existing Proposed NOTE: SNOW STORAGE WILL BE LOCATED ONSITE WHERE SHOWN. EXCESS SNOW WILL BE MOVED TO AN OFFSITE LOCATION IN RESPONSE TO THE FACILITY PARKING NEEDS. NOTE: CITY PARKING REQUIREMENT FOR RESIDENTIAL: 0.75 SPACES/1-BR-STUDIO-UNIT + 1.5 SPACES/2-BR-UNIT+ 0.75 SPACES/4 UNITS =(0.75*72 UNITS)+(1.5*11 UNITS)+ ((0.75)*(83 UNITS/4) = 86 RESIDENTIAL SPACES REQUIRED Zoning Summary Chart Zoning District(S):Form Based Code - Transect Zone 4 Overlay District(S):Major Intersections - Zone 1, Transit Overlay District Zoning Regulation Requirements Existing Required Provided Local Comments 10/8/21 SMW2 Local Comments 11/15/21 SMW3 Act 250 Submission 11/17/21 SMW4 Local Comments 12/17/21 SMW5 Local Submittal 05/18/22 PBS6 Local Comments 06/07/22 PBS7