HomeMy WebLinkAboutZP-22-390 - 1068 Williston Road 9/27/2022EXISTING 8x8 TEE
8" GATE VALVE
CONSTRUCTED 6" DI
WATER SERVICE.
6" GATE VALVE
8"x6" REDUCER WILLISTON ROADTO I-89
LIMITS OF FUTURE
RIGHT OF WAY
EXISTING PROPERTY LINE
SNOW STORAGE
AREA
SNOW STORAGE
AREA
PROPOSED 7'x12.5' TRANSFORMER PAD
LOCATION (K30.3 VAULT). CONTRACTOR
TO COORDINATE WITH GMP AND
ELECTRICAL PLANS
PROPOSED 4'X10'
GENERATOR PAD
PROPOSED 8'x15' TRANSFORMER PAD
LOCATION (K30.6 VAULT).
CONTRACTOR TO COORDINATE WITH
GMP AND ELECTRICAL PLANS
PROPOSED 7'x12.5' TRANSFORMER
PAD LOCATION (K30.3 VAULT).
CONTRACTOR TO COORDINATE WITH
GMP AND ELECTRICAL PLANS
BEGIN TEMPORARY 6"
BITUMINOUS CURB
END CONCRETE CURB
PEDESTRIAN PUSH BUTTON
PEDESTAL. LOCATION AND
WIRING TO BE COORDINATED
WITH ENGINEER AND SOUTH
BURLINGTON DPW
PRIMARY BUILDING FACADE12'
PLAZA
STONE DRIP EDGE
8' WIDE
MULTI-USE PATH
PEDESTRIAN PUSH BUTTON AND
SIGNAL HEAD TO BE MOUNTED
ON PROPOSED SIGNAL POLE.
COORDINATE FINAL LOCATION
AND WIRING WITH ENGINEER
AND SOUTH BURLINGTON DPW.
SIGNAL POLE AND FOUNDATION
BY OTHERS.
PERGOLA
PERGOLA
18.0'
9.0'
24.0'18.0'3.66'4.50'16
13
10
23
23
22
12
8
2
3
LA
LA
LA
SECONDARY STREET FRONTAGE=91.6'27'
PRIMARY STREET FRONTAGE=192.3'
BUILDING FRONTAGE =165.4'
PROPOSED FUTURE CITY STREET
LA
LA
LA
LA
36'
PROPOSED CONCRETE
DUMPSTER PAD. SEE DETAIL,
SHEET C7.2.BUILDING FRONTAGE=88.2'LA
TOTAL GSF = 59,815 SF
FFE = 313.95'
TOTAL GSF = 83,927 SF
HOLIDAY INN
FFE = 314.5'
(RENOVATION OF EXISTING
BUILDING)
PROPOSED
LOBBY
ADDITION
PRIMARY BUILDING FACADE
SECONDARY BUILDING FACADESECONDARY STREET BUILD TO ZONEPRIMARY BUILD TO ZONE 12'HAMPTON INN
FLUSH CURB AT ISLAND
13
9.0'18.0'
TOTAL GSF = 136,561 SF
FFE = 313.9'
MULTI-FAMILY BUILDING
PROPOSED
POOL
ADDITION BUILDING FRONTAGE =79'PRIMARY STREET FRONTAGE =136'LA
LA
LA
LA LA
LA
LA
LA
LA
LA
2
5.6'
WOOD
GUARDRAIL
RELOCATED CHAIN
LINK FENCE
FUTURE PHASE
2A
2B
3
EXISTING PROPERTY LINE
LIMITS OF FUTURE ROW
LIMITS OF PHASE 2A
LIMITS OF PHASE 2B
of
Project Number
Sheet
Drawing Number
Drawing Title
Issued for
Checked byDesigned by
Appvd.DateRevisionNo.vhb.comDate
40 IDX Drive, Building 100
Suite 200
South Burlington, VT 05403
Holiday Inn
Redevelopment
1068 Williston Rd.
South Burlington, Vermont
Review
Not Approved For Construction
July 29, 2021
27
57913.01
Proposed Site Plan
C2.01
2
CHS PBS
Feet6030015
Parking Summary Chart
Description
Spaces
Existing Proposed
NOTE:
SNOW STORAGE WILL BE LOCATED ONSITE WHERE
SHOWN. EXCESS SNOW WILL BE MOVED TO AN
OFFSITE LOCATION IN RESPONSE TO THE FACILITY
PARKING NEEDS.
NOTE:
CITY PARKING REQUIREMENT FOR RESIDENTIAL:
0.75 SPACES/1-BR-STUDIO-UNIT + 1.5 SPACES/2-BR-UNIT+ 0.75 SPACES/4 UNITS
=(0.75*72 UNITS)+(1.5*11 UNITS)+ ((0.75)*(83 UNITS/4) = 86 RESIDENTIAL SPACES REQUIRED
Zoning Summary Chart
Zoning District(S):Form Based Code - Transect
Zone 4
Overlay District(S):Major Intersections - Zone 1,
Transit Overlay District
Zoning Regulation Requirements Existing Required Provided
Local Comments 10/8/21 SMW2
Local Comments 11/15/21 SMW3
Act 250 Submission 11/17/21 SMW4
Local Comments 12/17/21 SMW5
Local Submittal 05/18/22 PBS6
Local Comments 06/07/22 PBS7