HomeMy WebLinkAboutZP-22-262 - 0045 San Remo Drive 7/14/2022Sewer
Qty Description GPD
Existing Building
20 Employees x 15 GPD /Employee =300
Subtotal 300
Proposed Land Use
19 Therapists/Employees x 13 GPD /Therapist =247
65 Clients x 4 GPD /Client =260
Subtotal 507
Supplemental Sewer Alloocation required 207
Water
Existing Building
20 Employees x 15 GPD /Employee =300
Subtotal 300
Proposed Land Use
19 Therapists/Employees x 13 GPD /Therapist =247
65 Clients x 4 GPD /Client =260
Subtotal 507
Supplemental Sewer Alloocation required 207
Unit Design Flow
45 San Remo Drive
Building Change of Use
Water & Sewer Design Flows
Friday, July 01, 2022
(SF)(VTE)(VTE)(VTE)
Description LUC Area Weekday AM PM
Existing
Single Tenant Office 715 8,828 99 16 15
Total 99 16 15
Proposed
Medical Office Clinic 630 8,828 337 33 32
Total 337 33 32
Change in Trip Generation 238 17 17
NFI Vermont, Inc.
Proposed Change in Use
Traffic Generation Summary
45 San Remo Drive, So. Burlington