Loading...
HomeMy WebLinkAboutSP-22-022 - Supplemental - 1717 Williston Road (5)JOB #LOCATIONCUSTOMERBUILDERPROJECTBUILDERS PO#VP BUILDINGSVARCO PRUDENFILENAME:VPC VERSION:DATEDRAWN / CHECKPAGEVP Buildings 3200 Players Club Circle Memphis TN 38125DRAWING RELEASE HISTORYTYPE DATE DESCRIPTIONDRAWING INDEXDRAWING TITLE PAGESCover SheetAnchor Rod PlanPrimary StructuralSecondary StructuralCoveringSpecial DrawingsStandard Erection DetailsCodes and LoadsREVERSALS ON CONNECTIONS.IT IS THE RESPONSIBILITY OF THE ERECTOR TO ENSURE PROPER BOLT TIGHTNESS IN ACCORDANCE WITH APPLICABLEREGULATIONS. SEE RCSC SPECIFICATION FOR STRUCTURAL JOINTS USING HIGH STRENGTH BOLTS FOR MORE INFORMATION. SEE ERECTION GUIDE FOR BOLT TIGHTENING INSTRUCTIONS. THE FOLLOWING CRITERIA MAY BE USED TO DETERMINE THE BOLT TIGHTNESS (I.E.-SNUG TIGHT OR PRE-TENSION) UNLESS REQUIRED OTHERWISE BY LOCAL JURISDICTIONOR CONTACT.PRE-TENSION A325 BOLTS IF BUILDING SUPPORTS A CRANE GREATER THAN 5 TON CAPACITY.PRE-TENSION A325 BOLTS IF BUILDING SUPPORTS MACHINERY THAT CREATES VIBRATION, IMPACT, OR STRESS PRE-TENSION A325 BOLTS IF LOCATED IN HIGH SEISMIC AREAS. FOR IBC BASED CODES; HIGH SEISMIC IS PRE-TENSION ANY CONNECTION WITH DESIGNATION A325-SC. SLIP CRITICAL (SC) CONNECTIONS MUST BE FREE OF PAINT,OIL, OR OTHER MATERIALS THAT REDUCE FRICTION AT CONTACT SURFACES. GALVANIZED OR LIGHTLY RUSTED SURFACES IN CANADA ALL A325 AND A490 BOLTS SHALL BE "PRE-TENSIONED", EXCEPT FOR SECONDARY MEMBERS AND FLANGESECONDARY MEMBERS AND FLANGE BRACE CONNECTIONS ARE ALWAYS "SNUG TIGHTENED" UNLESS INDICATED OTHERWISE IN ALL A490 BOLTS SHALL BE "PRE-TENSIONED". A325 BOLTS IN PRIMARY FRAMING AND BRACING CONNECTIONS MAY BE " SNUG-TIGHT" EXCEPT AS FOLLOWS; DESIGN CATEGORY D, E OR F. SEE CODES AND LOADS SECTION BELOW FOR DETAILS. ARE ACCEPTABLE. BRACES. ERECTION DRAWING DETAILS.GRADE 50A529, A572, A588, A992HOT ROLLED ANGLES GRADE BA500HOLLOW STRUCTURAL SECTION (HSS)HIGH STRENGTH BOLT TIGHTENING REQUIREMENTSMATERIALSGENERAL NOTESASTM DESIGNATIONGRADE 50 OR GRADE 80GRADE 36 OR 50GRADE 50GRADE 60GRADE 55A529, A572, A1011, A1018A653, A1011A572, A510A36, A529, A572, A588, A992A653, A792CLADDINGHOT ROLLED MILL SHAPESBRACE RODSCOLD FORMED LIGHT GAGE SHAPES3 PLATE WELDED SECTIONSRa division of BlueScope Buildings North America, Inc.VP BUILDINGSVARCO PRUDENa division of BlueScope Buildings North America, Inc.THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT ISPROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER ANDMAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USEDFOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS.THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT ISPROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER ANDMAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USEDFOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS.THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIPIN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALLAPPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION,INCLUDING THE CORRECT USE OF TEMPORARY BRACING.THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT ISPROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER ANDMAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USEDFOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS.THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIPIN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALLAPPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION,INCLUDING THE CORRECT USE OF TEMPORARY BRACING.THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VPAND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP.THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE ORDESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VPEXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIEDBY VP.Planograph DetailsNotesCINSPECTION AND TESTINGTHIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VP BUILDINGS. IT ISPROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER ANDMAY BE REPRODUCED ONLY FOR THAT PURPOSE. IT SHALL NOT BE MODIFIED, REPRODUCED OR USEDFOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF VP BUILDINGS.THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIPIN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALLAPPLICABLE VP BUILDINGS ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION,INCLUDING THE CORRECT USE OF TEMPORARY BRACING.THE VP ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF VPAND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY VP.THE VP ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE ORDESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY VPEXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIEDBY VP.SPECIAL INSPECTIONS AND TESTING REQUIRED BY AUTHORITY HAVING JURISDICTION (AHJ) DURING CONSTRUCTION AND/OR STEELFABRICATION IS THE RESPONSIBILITY OF THE OWNER OR OWNERS AUTHORIZED AGENT. WHEN REQUIRED, THE OWNER SHALLEMPLOY A QUALITY ASSURANCE AGENCY (QAA) APPROVED BY THE AHJ. THE BUILDER IS RESPONSIBLE TO COORDINATE BETWEENTHE QAA FIRM AND BBNA FABRICATION FACILITIES. THE TYPE AND EXTENT OF SPECIAL INSPECTIONS AND NDT WELD TESTING MUSTBE SPECIFICALLY STIPULATED IN CONTRACT DOCUMENTS OR BBNA WILL ASSUME SPECIAL INSPECTIONS AND/OR NDT TESTING AREWAIVED AS PERMITTED BY THE BUILDING CODE BASED ON BBNA FACILITIES IAS AC472 ACCREDITATION.COVER SHEETSouth Burlington, VermontVermont Mattress and Bedroom Company3/25/2022VT Mattress & Bedroom Co2021.3c13:31:453/25/2022 1 VCC07003090Part Mark Key2 JTG13 PG14 H25 GFA1061 4'-0Dimension Key2 3'-63 3'-94 2'-95 3'-4MarkSecondary Part SchedulePartThick.DepthLapDetailG100108ZS1511417000.06008 1/2WS12A2,WS01G3,BRR052,WS20F2G1000608ZS0705417000.06008 1/2BRR052,WS01G3,WS20F2G300308ZS0611517000.06008 1/2WS04C2,BRR052,WS01G2G500408ZS1711417000.06008 1/2WS12A2,WS01G3,WS20F2,BRR052G908Z0407417GQ000.06008 1/2WS12A2,BRR052,WS20F2H100108JS10000170.06008 1/2WS20F9H2DHC03040170.00008 1/2WS21D7J100308JS10112170.06008 1/2WS20F9,WS20F2,WS20B2,WS20B8J200208JS11091170.06008 1/2WS20F9,WS20F2,WS20B5,BRR052,WS20B8J300408JS07022170.06008 1/2WS20F2,WS20B2,WS20B846'-014'-012'-015'-018'-013'-0DBLABLCLCCLB12121W3B0G5(Typ.)33H133J13J21W3B1G32142133J333J31W3B2G9G1221W3B1G101234110'-01155'-810'-07'-25555SECONDARY ELEVATION AT 6VPC VERSION: FILENAME: JOB #DATEDRAWN/CHECKPAGEBUILDERCUSTOMERLOCATIONPROJECTBUILDERS PO#DATEREV BY DESCRIPTIONVP BUILDINGSVARCO PRUDENVP Buildings3200 Players Club Circle Memphis TN 38125A BlueScope Steel Companya division of BlueScope Buildings North America, Inc.THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VPBUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THEAPPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. ITSHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUTPRIOR WRITTEN APPROVAL OF VP BUILDINGS.THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VPBUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THEAPPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. ITSHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUTPRIOR WRITTEN APPROVAL OF VP BUILDINGS.THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATEGOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THISDRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGSERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION,INCLUDING THE CORRECT USE OF TEMPORARY BRACING.THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF VPBUILDINGS. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THEAPPLICABLE PURCHASE ORDER AND MAY BE REPRODUCED ONLY FOR THAT PURPOSE. ITSHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUTPRIOR WRITTEN APPROVAL OF VP BUILDINGS.THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATEGOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THISDRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE VP BUILDINGSERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION,INCLUDING THE CORRECT USE OF TEMPORARY BRACING.THE VP ENGINEER'S SEAL APPLIES ONLY TOTHE WORK PRODUCT OF VP AND DESIGN ANDPERFORMANCE REQUIREMENTS SPECIFIED BY VP.THE VP ENGINEER'S SEAL DOES NOT APPLY TOTHE PERFORMANCE OR DESIGN OF ANY OTHERPRODUCT OR COMPONENT FURNISHED BY VPEXCEPT TO ANY DESIGN OR PERFORMANCEREQUIREMENTS SPECIFIED BY VP.CSECONDARY ELEVATION AT 6South Burlington, VermontVermont Mattress and Bedroom Company3/25/2022VT Mattress & Bedroom Co2021.3cNTS1. UNLESS NOTED, USE 1/2 X 1 1/2 A325T BOLT (49080) AND NUT (47120) W/O WASHERS. SNUG TIGHTEN BOLTS FOR ALL SECONDARY CONNECTIONS.2. FLANGE BRACES ARE AN INTEGRAL PART OF THE STABILITY OF THE STRUCTURAL SYSTEM AND MUST BE PROPERLY INSTALLED PRIOR TO ERECTION OF WALL AND ROOF SHEETS. 3. REMOVAL OR ALTERATION OF ANY COMPONENT IS PROHIBITED.Shape Name = 46x108x14, Wall = 33/25/2022 13:32:09