Loading...
HomeMy WebLinkAboutZP-22-216 - 0039 Ledge Way 6/10/2022JOB NO:DRAWN:PROJ MGR:CHECKED:ISSUE DATE:O'Brien Home Farm Single Family Uphill LotSouth Burlington, VermontAGN0.109/01/17COVER SHEET, SHEETINDEX39 Ledge WaySHEET INDEXA4.1.3 DECK OPTIONSAGN0.1 COVER SHEET, SHEET INDEXAGN0.2 GENERAL NOTESELEVATION AA0.1A FOUNDATION/WALKOUT PLAN-AA1.1A MAIN FLOOR PLAN-AA3.1A EXTERIOR ELEVATIONS & ROOFPLAN-FarmhouseA4.2.1A OPT COVERED DECK-AA6.1A BUILDING SECTIONS-AA6.2A BUILDING SECTIONS-AA4.2.2 MUDROOM OPTIONSA0.1B FOUNDATION/BASEMENT PLAN-BA1.1B MAIN FLOOR PLAN-BA3.1B EXTERIOR ELEVATIONS & ROOFPLAN-CRAFTSMANA4.2.1B OPT COVERED DECK-BA6.1B BUILDING SECTIONS-BA6.2B BUILDING SECTIONS-BA0.2A Foundation/Basement Plan w/ BedroomA4.1.1 OPT. BASEMENT FINISHEDA4.1.2 PLAN OPTIONSA5.1 STAIR SECTIONELECTRICALE0.1A BASEMENT ELECTRICAL PLAN-AE1.1A MAIN FLOOR ELECTRICAL PLAN-AE0.1B BASEMENT ELECTRICAL PLAN-BE1.1B MAIN FLOOR ELECTRICAL PLAN-BE4.1.1 OPTIONAL BASEMENT FINISHEDELECTRICALSTRUCTURES0.1A MAIN FLOOR FRAMING PLAN-AS1.1A ROOF FRAMING PLAN-AS0.1B MAIN FLOOR FRAMING PLAN-BS1.1B ROOF FRAMING PLAN-BAD.4 CABINET PLANSAD.1 DETAILSAD.2 DETAILSAD.3 DETAILSSouth Burlington, VermontO'Brien Home FarmSingle Family Uphill Lot DaylilySquare Footages-BELEVATION BBASEMENT LIVING 307 SFMAIN FLOOR LIVING 1591 SFTOTAL LIVING 1898 SFDAYLILYPLAN OPTIONSBASEMENT BEDROOM/BATH 289 SFCraftsman Elevation - BREVISIONS FDCONSTRUCTION ASSEMBLIES:T THE FOLLOWING KEYNOTES REFERENCE THE SYMBOLS AS SHOWN ON PLANSA. ROOF CONSTRUCTION:COMPOSITION ROOF SHINGLES ON UNDERLAYMENT ON ROOF SHEATHING ON ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD OVER MOISTURE VAPOR RETARDER WITH INSULATION ABOVE.B1. TYPICAL SIDING WALL CONSTRUCTION:SIDING ON WATER RESISTANT BARRIER ON EXTERIOR WALL SHEATHING ON 2x4 STUDS, 16" O.C. OR 2x6 STUDS, 24" O.C. W/ INSULATION IN CAVITIES.INTERIOR: 1/2" GYPSUM BOARD OVER MOISTURE VAPOR RETARDER.B2. TYPICAL STONE VENEER WALL CONSTRUCTION:ADHERED SYNTHETIC STONE VENEER (INSTALLED PER MFR'S SPECS.) OVER WATER RESISTANT BARRIER ON EXTERIOR WALL SHEATHING ON 2x4 STUDS, 16" O.C. OR 2x6 STUDS, 24" O.C. W/ INSULATION IN CAVITIES.INTERIOR: 1/2" GYPSUM BOARD OVER MOISTURE VAPOR RETARDER.C. TYPICAL FLOOR CONSTRUCTION:FINISHED FLOORING ON 3/4" FLOOR SHEATHING ON FLOOR FRAMING AS NOTED ON STRUCTURAL DRAWINGS.MAIN FLOOR CEILING: 1/2" GYPSUM BOARD.D. CONCRETE SLAB CONSTRUCTION:4" CONCRETE SLAB OVER 6 MIL. POLYETHYLENE VAPOR BARRIER OVER 4" MINIMUM GRANULAR FILL.2 Car GarageUP 15 RISERSWHFURN25'-0"16070 OGD3050 DH 3050 DH1A5.11471471471471261271283A6.2B2A6.1B1A6.1B8"8"7'-8"11'-8"8"1317'-6" SOFFIT2x8 WALLF-2 F-2 F-2F-2F-P F-PW-8 TYPICAL8" 5'-10" 6'-0" 6'-0" 5'-10" 8"W-8 TYPICAL1481481482x4 WALL12'-0"8'-4"19'-8"2'-0"38'-0"6'-0"22'-0"20'-0"1245'-0 1/2"48'-0"40'-0"6'-0" 6'-0" 1'-4" 4'-0" 3'-0" 9'-2 1/2" 10'-5 1/2"20'-8 1/2"MODIFY WOOD TRUSS AS REQUIRED FOR RAISED LVL BEAM2-2x12 DROPPED BEAM2-2x10 P.T. DECK BEAM3-1 3/4" x 9 1/4" LVL DROPPED BEAM2-1 3/4" x 16" LVL DROPPED BEAM2-2x10 FLUSH BEAM3-1 3/4" x 16" LVL DROPPED BEAM(3) 1 3/4" x 14" LVL3- 2x6 JACK2- 2x6 KINGEACH END3 1/2"x7" PSL(3) 1 3/4" x 14" LVLBEARING WALLMECHANICALS TO BE LOCATED AT FULL DISCRETION OF O'BRIEN BROTHERS1'-9" 3'-2" 3'-11"266810'-4"210682106826682668306830685068 SLD20687'-10 1/2"36 x 48KEYPADGENERAL BASEMENT PLAN NOTES:* ALL UNDIMENSIONED PARTITIONS ( ) ARE 3 1/2" ROUGH UNLESS NOTED OTHERWISE.* IF MAIN FLOOR FRAMING IS TO BE INSTALLED BEFORE CONCRETE FLOOR, PROVIDE THE FOLLOWING:** AT PAD FOOTINGS, PROVIDE 8"x8" CONCRETE PEDESTAL FLUSH WITH CONCRETE FLOOR FOR ATTACHMENT OF POST BASE** AT CONTINUOUS FOOTINGS UNDER FRAMING BEARING WALLS, PROVIDE 6" WIDE CONTINUOUS CONCRETE STEM, TOP OF STEM FLUSH WITH CONCRETE FLOOR & CENTERED ON FOOTING.* ALL ANGLED PARTITIONS ARE 45 DEGREES UNLESS NOTED OTHERWISE.* ALL EXTERIOR DIMENSIONS ARE TO FACE OF STUDS UNLESS NOTED OTHERWISE.* WINDOW SUPPLIER TO VERIFY AT LEAST ONE WINDOW IN ALL BEDROOMS MEETS ALL EMERGENCY EGRESS REQUIREMENTS.* ALL ELECTRICAL AND MECHANICAL EQUIPMENT, METER LOCATIONS, ETC SHALL BE CONFIRMED BY MECHANICAL AND ELECTRICAL CONTRACTORS. CONTRACTORS SHALL COORDINATE WITH BUILDER PRIOR TO RELOCATION OF EQUIPMENT AND METERS.* ALL TRUSSES TO BEAR ON EXTERIOR WALLS AND/OR GIRDER TRUSS UNLESS NOTED OTHERWISE.* TRUSS MFG. TO SIZE MEMBERS, FASTENERS, HANGERS & SET SPACING FOR ALL TRUSSES.* FOR ADDITIONAL INFORMATION SEE GENERAL NOTES AND DETAILS.* TYPICAL WINDOW HEAD HEIGHTS SHALL BE 7'-0" A.F.F. (U.N.O.)* PROVIDE BLOCKING FOR ALL GRABBARS IN BATHS, SEE DETAILSSYMBOLTYPESIZEFOOTING SCHEDULEF-P PIER (EXTERIOR)REINFORCING12" SONOTUBE W/ BELL BOTTOMNAF-C CONTINOUS FOOTING2'-0" WIDE x 0'-8" DEEP 3-#4's CONTINUOUSF-2PAD FOOTING (INTERIOR) 2'-0" x 2'-0" x 1'-0" DEEP NACOLUMN6x6 TREATED POSTNA*NOTE: LALLY COLUMNS SHALL HAVE THE ALLOWABLE MINIMUM LOAD CAPACITY OUTLINED IN THE GENERAL NOTES. SEE GENERAL NOTES FOR BOTTOM AND TOP BEARING PLATES.COMMENTS48" MIN. BELOW FINISH GRADE3 1/2" LALLY COLUMN UNLESS NOTED OTHERWISE*SYMBOLWALL THICKNESSWALL HEIGHTFOUNDATION WALL SCHEDULEW-8 8" 9'-0"REINFORCING2 #4 BARS TOP & BOTTOM*CONTINUOUS FOOTING1'-4"x 0'-8" W/ 2-#4's CONTINUOUS*IF FOOTING IS BEARING ON EARTH BUILDER TO VERIFY SOIL PRESSURE AND USE 2'-0"x0'-8" CONTINUOUS FOOTINGJOB NO:DRAWN:PROJ MGR:CHECKED:ISSUE DATE:O'Brien Home Farm Single Family Uphill LotSouth Burlington, VermontA0.1B09/01/17FOUNDATION/BASEMENTPLAN-B39 Ledge WayElevation - BSCALE:1/4" = 1'-0" (22x34)Foundation/Basement PlanDAYLILYKEYNOTES:FLOOR PLAN101 SINK W/ GARBAGE DISPOSAL.102 DISHWASHER.103 REFRIGERATOR.104 RANGE W/ HOOD/MICRO.107 PANTRY SHELVES PER BUILDER SPEC.108 BASE CABINETS.109 UPPER CABINETS.110 WATER CLOSET.111 LAV. SINK.113 SHOWER (SIZE PER PLAN).115 DROP IN TUB W/ PLATFORM.116 TUB/SHOWER (SIZE PER PLAN).117 LINEN SHELVES PER BUILDER SPEC.118 WASHER.119 DRYER.121 LINE OF SHELF ABOVE.122 ROD & SHELF.123 ATTIC ACCESS (22"x30" U.N.O.).124 HANDRAIL.125 SOLID CORE DOOR W/ SELF CLOSER.126 LINE OF OVERHEAD GARAGE DOOR IN OPENPOSITION.127 PROVIDE 5/8" TYPE "X" GYPSUM BOARD INGARAGE AS REQUIRED BY CODE.128 SLOPE GARAGE FLOOR 1/8" PER FOOTTOWARD GARAGE DOOR OPENING.130 LINE OF SOFFIT ABOVE (REFER TO EXTERIORELEVATIONS FOR HEIGHTS AND DETAILS).131 GYPSUM BOARD SOFFIT (HEIGHT AS NOTED).133 LINE OF FRAMING BELOW.135 PREFABRICATED FIREPLACE, GAS (NON-WOODBURNING) AS SPECIFIED BY BUILDER.137 42" HIGH EXTERIOR GUARDRAIL W/ BALUSTERSTO BE SPACED SUCH THAT 4" SPHERE CANNOTPASS BETWEEN BALUSTERS.138 2X6 HALF WALL @ 34 1/2" A.F.F. W/ COUNTER140 2X6 LOW WALL 42" A.F.F.141 2x4 HALF WALL @ 42" A.F.F. W/ WOOD CAP.142 OPTIONAL PET SPACE 36" A.F.F.147 LINE OF DECK ABOVE.148 BEAM POCKET.150151152REVISIONS REF.DWCONSTRUCTION ASSEMBLIES:T THE FOLLOWING KEYNOTES REFERENCE THE SYMBOLS AS SHOWN ON PLANSA. ROOF CONSTRUCTION:COMPOSITION ROOF SHINGLES ON UNDERLAYMENT ON ROOF SHEATHING ON ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD OVER MOISTURE VAPOR RETARDER WITH INSULATION ABOVE.B1. TYPICAL SIDING WALL CONSTRUCTION:SIDING ON WATER RESISTANT BARRIER ON EXTERIOR WALL SHEATHING ON 2x4 STUDS, 16" O.C. OR 2x6 STUDS, 24" O.C. W/ INSULATION IN CAVITIES.INTERIOR: 1/2" GYPSUM BOARD OVER MOISTURE VAPOR RETARDER.B2. TYPICAL STONE VENEER WALL CONSTRUCTION:ADHERED SYNTHETIC STONE VENEER (INSTALLED PER MFR'S SPECS.) OVER WATER RESISTANT BARRIER ON EXTERIOR WALL SHEATHING ON 2x4 STUDS, 16" O.C. OR 2x6 STUDS, 24" O.C. W/ INSULATION IN CAVITIES.INTERIOR: 1/2" GYPSUM BOARD OVER MOISTURE VAPOR RETARDER.C. TYPICAL FLOOR CONSTRUCTION:FINISHED FLOORING ON 3/4" FLOOR SHEATHING ON FLOOR FRAMING AS NOTED ON STRUCTURAL DRAWINGS.MAIN FLOOR CEILING: 1/2" GYPSUM BOARD.D. CONCRETE SLAB CONSTRUCTION:4" CONCRETE SLAB OVER 6 MIL. POLYETHYLENE VAPOR BARRIER OVER 4" MINIMUM GRANULAR FILL.3060 DH 3060 DH3060 DH 3060 DH 3060 DH9' -0" CLGFamilyDeck9' -0" CLGDining9' -0" CLGW.I.C.9' -0" CLGKitchen9' -0" CLGMaster Bedroom9' -0" CLGBedroom 29' -0" CLGBath 29' -0" CLGMaster Bath9' -0" CLGLaundryFoyer25'-0"24'-1"5'-11 1/2"6'-8"7'-6"210682106821068210682106821068 PKT210681668246828685068 SLD20686068 SLD2040 DH3060 DH3060 DH 3060 DH 3060 DH3060 DH 3060 DH 3060 DH 3060 DHDN 15RISERSPorch30683 3/4"38'-0"0"11'-6" 2'-1" 9'-1 1/2"14'-4 1/2"4'-9" 4'-4 1/2" 1'-10" 13'-0"2'-3 3/4" 2'-0" 11'-0" 5'-5 1/2" 4'-3 1/2" 9'-5"11'-10"2'-3 3/4" 13'-0"31'-0"2'-0"4'-0"3'-4" 3'-4"35'-8"4'-4"1A5.16010 TRN ABV.3010 TRN ABV.DN AS REQ'D12211611111012232"x60"40'-0"1331331181191031041011021091081091081081091111111131101231221221221301411171071171381213A6.2B2A6.1B1A6.1B7'-4 1/2" 4'-0" 4" 5'-5" 4" 3'-2 1/2" 7'-9 1/2" 3'-3 1/2" 4'-1" 3'-8 1/2"5'-5 1/2" 2'-4 1/2" 4'-0" 3'-8 1/2" 3'-3 1/2" 4'-0" 5'-4 1/2" 7'-0"10'-7 1/2"21'-2 1/2"1'-7 1/2"8 1/2"7 1/2"3'-8"2'-8 1/2"1'-5"5'-4"2'-8 1/2"10'-0 1/2" 7 1/2" 3'-4" 2'-10" 1'-4" 1'-0" 14'-10" 3'-10" 4'-2"4'-11 1/2"2'-11"10'-10"13'-0"1082x6 WALL2x6 WALL2x6 WALL4'-8 1/2"12413746'-3 3/4"6'-0" 7'-4" 4'-0" 9'-10" 8'-6"1'-8 1/4"1'-8 1/4"1501521511501511521522020 FXPRIVACY WALLGAS LINEGAS LINE6'-2"7'-7 3/4"Gas LineCenter between winodow and cornerEQ.EQ.GENERAL FLOOR PLAN NOTES:* ALL UNDIMENSIONED PARTITIONS ( ) ARE 3 1/2" ROUGH UNLESS NOTED OTHERWISE.* ALL EXTERIOR DIMENSIONS ARE TO FACE OF STUDS UNLESS NOTED OTHERWISE.* ALL ANGLED PARTITIONS ARE 45 DEGREES UNLESS NOTED OTHERWISE.* WINDOW SUPPLIER TO VERIFY AT LEAST ONE WINDOW IN ALL BEDROOMS MEETS ALL EMERGENCY EGRESS REQUIREMENTS.* ALL ELECTRICAL AND MECHANICAL EQUIPMENT, METER LOCATIONS, ETC. SHALL BE CONFIRMED BY MECHANICAL AND ELECTRICAL CONTRACTORS. CONTRACTORS SHALL COORDINATE WITH BUILDER PRIOR TO RELOCATION OF EQUIPMENT AND METERS.* ALL TRUSSES TO BEAR ON EXTERIOR WALLS AND/OR GIRDER TRUSS UNLESS NOTED OTHERWISE.* TRUSS MFG. TO SIZE MEMBERS, FASTENERS, HANGERS & SET SPACING FOR ALL TRUSSES.* FOR ADDITIONAL INFORMATION SEE GENERAL NOTES AND DETAILS.* TYPICAL WINDOW HEAD HEIGHTS SHALL BE 8'-0 7/8" A.F.F. (U.N.0.) W/ 9'-1 1/8" CLG. AND 7'-0 7/8" A.F.F (U.N.O.) W/ 8'-1 1/8" CLG.* PROVIDE BLOCKING FOR ALL GRABBARS IN BATHS, SEE DETAILS.JOB NO:DRAWN:PROJ MGR:CHECKED:ISSUE DATE:O'Brien Home Farm Single Family Uphill LotSouth Burlington, VermontA1.1B09/01/17MAIN FLOOR PLAN-B39 Ledge WayElevation - BSCALE:1/4" = 1'-0" (22x34)Main Floor PlanDAYLILYKEYNOTES:FLOOR PLAN101 SINK W/ GARBAGE DISPOSAL.102 DISHWASHER.103 REFRIGERATOR.104 RANGE W/ HOOD/MICRO.107 PANTRY SHELVES PER BUILDER SPEC.108 BASE CABINETS.109 UPPER CABINETS.110 WATER CLOSET.111 LAV. SINK.113 SHOWER (SIZE PER PLAN).115 DROP IN TUB W/ PLATFORM.116 TUB/SHOWER (SIZE PER PLAN).117 LINEN SHELVES PER BUILDER SPEC.118 WASHER.119 DRYER.121 LINE OF SHELF ABOVE.122 ROD & SHELF.123 ATTIC ACCESS (22"x30" U.N.O.).124 HANDRAIL.125 SOLID CORE DOOR W/ SELF CLOSER.126 LINE OF OVERHEAD GARAGE DOOR IN OPENPOSITION.127 PROVIDE 5/8" TYPE "X" GYPSUM BOARD INGARAGE AS REQUIRED BY CODE.128 SLOPE GARAGE FLOOR 1/8" PER FOOTTOWARD GARAGE DOOR OPENING.130 LINE OF SOFFIT ABOVE (REFER TO EXTERIORELEVATIONS FOR HEIGHTS AND DETAILS).131 GYPSUM BOARD SOFFIT (HEIGHT AS NOTED).133 LINE OF FRAMING BELOW.135 PREFABRICATED FIREPLACE, GAS (NON-WOODBURNING) AS SPECIFIED BY BUILDER.137 42" HIGH EXTERIOR GUARDRAIL W/ BALUSTERSTO BE SPACED SUCH THAT 4" SPHERE CANNOTPASS BETWEEN BALUSTERS.138 2X6 HALF WALL @ 34 1/2" A.F.F. W/ COUNTER140 2X6 LOW WALL 42" A.F.F.141 2x4 HALF WALL @ 42" A.F.F. W/ WOOD CAP.142 OPTIONAL PET SPACE 36" A.F.F.147 LINE OF DECK ABOVE.148 BEAM POCKET.150151152REVISIONS CONSTRUCTION ASSEMBLIES:T THE FOLLOWING KEYNOTES REFERENCE THE SYMBOLS AS SHOWN ON PLANSA. ROOF CONSTRUCTION:COMPOSITION ROOF SHINGLES ON UNDERLAYMENT ON ROOF SHEATHING ON ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD OVER MOISTURE VAPOR RETARDER WITH INSULATION ABOVE.B1. TYPICAL SIDING WALL CONSTRUCTION:SIDING ON WATER RESISTANT BARRIER ON EXTERIOR WALL SHEATHING ON 2x4 STUDS, 16" O.C. OR 2x6 STUDS, 24" O.C. W/ INSULATION IN CAVITIES.INTERIOR: 1/2" GYPSUM BOARD OVER MOISTURE VAPOR RETARDER.B2. TYPICAL STONE VENEER WALL CONSTRUCTION:ADHERED SYNTHETIC STONE VENEER (INSTALLED PER MFR'S SPECS.) OVER WATER RESISTANT BARRIER ON EXTERIOR WALL SHEATHING ON 2x4 STUDS, 16" O.C. OR 2x6 STUDS, 24" O.C. W/ INSULATION IN CAVITIES.INTERIOR: 1/2" GYPSUM BOARD OVER MOISTURE VAPOR RETARDER.C. TYPICAL FLOOR CONSTRUCTION:FINISHED FLOORING ON 3/4" FLOOR SHEATHING ON FLOOR FRAMING AS NOTED ON STRUCTURAL DRAWINGS.MAIN FLOOR CEILING: 1/2" GYPSUM BOARD.D. CONCRETE SLAB CONSTRUCTION:4" CONCRETE SLAB OVER 6 MIL. POLYETHYLENE VAPOR BARRIER OVER 4" MINIMUM GRANULAR FILL.BASEMENT FLOORT.O.F.MAIN FLOORMAIN PLATEPORCH STOOPPORCH PLATE9'-1 1/8"11 1/2"8'-8"8'-10"4'-8"6" 12"6" 12"6" 12"6" 12"6" 12"6" 12"6" 12"6" 12"2152152042242032112102012237'-8"2153AD.13AD.210AD.28AD.2AD.316AD.2SIM207213BASEMENT FLOORT.O.F.MAIN FLOORMAIN PLATE8'-8" 11 1/2" 9'-1 1/8"6" 12"6" 12"6" 12"2032102232013AD.19AD.21AD.25AD.2BASEMENT FLOORT.O.F.MAIN FLOORMAIN PLATEPORCH STOOPPORCH PLATE9'-1 1/8"11 1/2"8'-8"8'-10"4'-8"6" 12"6" 12"6" 12"2032112232242102152013AD.18AD.210AD.24'-8"22'-1 1/2"BASEMENT FLOORT.O.F.MAIN FLOORMAIN PLATEPORCH STOOPPORCH PLATE9'-1 1/8"11 1/2"8'-8"8'-10"4'-8"6" 12"6" 12"6" 12"2102242112032018AD.25AD.23AD.19AD.24'-8"18'-7 1/2"6" / 12"6" / 12"6" / 12"6" / 12"6" / 12"6" / 12"6" / 12"6" / 12"6" / 12"6" / 12"6" / 12"EAVE TYP1'-0"RAKE TYP1'-0"MAIN ROOFLOWER ROOFGENERAL EXTERIOR ELEVATION NOTES:* GRADE CONDITIONS MAY VARY FOR INDIVIDUAL SITE FROM THAT SHOWN.* PROVIDE ROOF AND SOFFIT VENTS AS SPECIFIED BY BUILDER.* PROVIDE GUTTERS AND DOWNSPOUTS AS SPECIFIED BY BUILDER.JOB NO:DRAWN:PROJ MGR:CHECKED:ISSUE DATE:O'Brien Home Farm Single Family Uphill LotSouth Burlington, VermontA3.1B09/01/17EXTERIOR ELEVATIONS &ROOF PLAN-CRAFTSMAN39 Ledge WayElevation - CraftsmanSCALE:1/4" = 1'-0" (22x34)Front ElevationSCALE:1/8" = 1'-0" (22x34)Rear ElevationSCALE:1/8" = 1'-0" (22x34)Right ElevationSCALE:1/8" = 1'-0" (22x34)Left ElevationSCALE:1/8" = 1'-0" (22x34)Roof PlanDAYLILYKEYNOTES:EXTERIOR ELEVATION201 ROOFING PER BUILDER SPEC.203 6" LAP SIDING.204 SHAKE SIDING.205 BOARD & BATTEN SIDING.207 PANEL SIDING.210 ALUMINUM WRAPPED 2x8 FASCIA.211 ALUMINUM WRAPPED 2x8 RAKE.213 5/4x4 TRIM.214 5/4x6 TRIM.215 5/4x8 TRIM.223 5/4x6 FRIEZE TRIM.224 BRACKET- FYPON BKT16X18X3 OR EQUALNOTE:* REQUIRED NET FREE VENTED AREAS ARE CALCULATED BY MULTIPLYING THE ACTUAL ATTIC AREA (SQ FT) IN COLUMN 1BY 1/300 AND MULTIPLYING SUM BY 144 SQ IN/SQ FT 40%-50% OF TOTAL NET FREE VENTED AREA IS REQUIRED AT THERIDGE (HIGH) AND THE REMAINING IS THE REQUIRED IN THE SOFFIT (LOW). WHEN NO "HIGH/LOW" VENTING IS PROVIDED,THE REQUIRED NET FREE AREA IS 1/150 OF THE ACTUAL AREA AND 100% OF THIS VENTED AREA SHALL BE PROVIDED ATTHE SOFFIT.** ACTUAL NET FREE VENTED SOFFIT AREAS ARE CALCULATED BY DIVIDING THE REQUIRED NET FREE VENTED SOFFITAREA (FT) BY THE MANUFACTURERS STATED ACTUAL VENTED NET FREE AREA PER VENT. WHEN APPLICABLE, THE ACTUALTOTAL NUMBER OF SOFFIT VENTS SHALL BE DIVIDED EQUALLY BETWEEN EACH EAVE AND SPACED AN EQUAL DISTANCEAPART FROM ONE ANOTHER.ACTUAL NET FREE VENTED RIDGE AREAS ARE CALCULATED BY DIVIDING THE REQUIRED NET FREE VENTED RIDGE AREA...ATTIC VENTILATION SCHEDULE (ELEVATION B)Name AreaTOTAL NETVENTED(1/300) (SQ IN)TOTAL NETVENTED(1/150) (SQ IN)*LOWER VENTMIN (50%)*LOWER VENTMAX (60%)*UPPER VENTMIN (40%)*UPPER VENTMAX (50%)MAIN ROOF 1644 SF 789 in² 1579 in² 395 in² 474 in² 316 in² 395 in²LOWER ROOF 45 SF 22 in² 43 in² 11 in² 13 in² 9 in² 11 in²REVISIONS FD33UP3334D1A6.1BGFISDSDCOTVTV6" LED SURFACE6" LED SURFACECERAMICTVCERAMICCERAMICCERAMICCERAMICCERAMIC CERAMIC6" LED SURFACE LIGHT6" LED SURFACE LIGHT6" LED SURFACE LIGHT6" LED SURFACE LIGHT6" LED SURFACE LIGHT6" LED SURFACE LIGHT6" LED SURFACE LIGHTFLUSHFLUSHPHOTOCELLTELECTRICAL NOTES:* PROVIDE AND INSTALL LOCALLY CERTIFIED SMOKE DETECTORS AS REQUIRED BY NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) AND MEETING THE REQUIREMENTS OF ALL GOVERNING CODES* PROVIDE AND INSTALL GROUND FAULT CIRCUIT-INTERRUPTERS (GFI) AS REQUIRED BY NATIONAL ELECTRIC CODE (NEC) AND MEETING THE REQUIREMENTS OF ALL GOVERNING CODES.* ELECTRICAL CONTRACTOR TO PROVIDE REQUIRED DIRECT HOOK-UPS/CUTOFFS.* HVAC CONTRACTOR TO VERIFY THERMOSTAT LOCATIONS.* ALL ELECTRICAL AND MECHANICAL EQUIPMENT (I.E. FURNACES, A/C UNITS, ELECTRICAL PANELS, SANITARY SUMP PITS, DRAIN TILE SUMP, AND WATER HEATERS) ARE SUBJECT TO RELOCATION DUE TO FIELD CONDITIONS.* ALL BRANCH CIRCUITS THAT SUPPLY 125 VOLT 15 & 20 AMP RECEPTACLE OUTLETS INSTALLED IN ANY HABITAL SPACE SHALL BE PROTECTED BY AN ARC FAULT CIRCUIT INTERRUPTER PER N.E.C. 210-12(A) & (B).ELECTRICAL DEVICES:ABOVE FINISHED FLOOR:SWITCHES OVER COUNTER.................. 48" TO CLWALL OUTLETS OVER COUNTER..........48" TO CLREMAINING SWITCHES...........................48" TO CLWALL OUTLETS........................................ 12" TO CLBATH VANITY BRACKET OUT(1" ABOVE TOP OF MIRROR)............80" TO CLWATER SOFTENER AND SUMP OUTLETS........................................48" TO CLTELEPHONE OUTLETS............................12" TO CLTELEVISION OUTLETS.............................12" TO CLEXTERIOR GFI OUTLETS.........................12" TO CLGARAGE GFI (ABOVE GARAGE FLOOR)12" TO CLBASEMENT WALL OUTLETS...................48" TO CLFRONT DOOR COACH LIGHT..................72" TO CLGARAGE DOOR COACH LIGHT(ABOVE GARAGE FLOOR).......................84" TO CLDINING AND BREAKFAST FIXTURE........64" TO BOTTOMOF FIXTUREFOYER AND STAIRWAY FIXTURE.......... 96" TO BOTTOMOF FIXTURETHERMOSTAT...........................................54" TO CLDOORBELL CHIMES.................................84" TO CLDOORBELL BUTTON................................LEVEL W/DOOR HANDLEKITCHEN HOOD FAN "WHIP"...................66" TO CLKITCHEN WALL HUNGMICROWAVE OUTLET..............................76" TO CLKITCHEN DISHWASHER RECEPTACLE.UNDER SINKKITCHEN RANGE......................................24" TO CLKITCHEN REFRIGERATOR......................48" TO CLWASHER/DRYER OUTLET...................... 48" TO CLCL = CENTERLINE1 = FIELD VERIFY2 = MASTER BATH STANDARD 30" HIGHVANITY TO BE RAISED 4"1,2ELECTRICAL KEY:SINGLE POLE OUTLETDUPLEX CONVENIENCE OUTLETDUPLEX OUTLET ABOVE COUNTERWEATHERPROOF DUPLEX OUTLETWPGFIGROUND-FAULT CIRCUIT-INTERRUPTER DUPLEX OUTLETHALF-SWITCHED DUPLEX OUTLETSPECIAL POURPOSE OUTLET/JUNCTION BOXUSB CHARGER/TAMPER-RESISTANT DUPLEX OUTLETUSBDUPLEX OUTLET IN FLOOR220 VOLT OUTLET220VOVERHEAD DUPLEXWALL SWITCHTHREE-WAY SWITCHFOUR-WAY SWITCHDIMMER SWITCHREINFORCED JUNCTION BOXCEILING MOUNTED LIGHT FIXTUREWALL MOUNTED LIGHT FIXTURERECESSED LIGHT FIXTURERECESSED LIGHT FIXTURE (WEATHERPROOF)WPRECESSED FLOURESCENT LIGHT FIXTURE (WEATHERPROOF)FLURRECESSED LIGHT FIXTURE (VAPOR-PROOF)VPRECESSED FLOURESCENT LIGHT FIXTURE (VAPOR-PROOF)VP/FLURPNDTCEILING MOUNTED PENDANT LIGHT FIXTUREMINICEILING MOUNTED MINI-PENDANT LIGHT FIXTURELEDCEILING MOUNTED LED LIGHT FIXTUREWALL MOUNTED LED LIGHT FIXTURELEDRECESSED LED LIGHT FIXTURELEDRECESSED ADJUSTABLE EYEBALL LED LIGHT FIXTUREEBPCLED LIGHT FIXTURE WITH PULL CHAINFLUORESCENT LIGHT FIXTUREFLUORESCENT LIGHT FIXTURE WITH PULL CHAINPCEXHAUST FAN (VENT TO EXIT)EXHAUST FAN/LIGHT COMBINATION (VENT TO EXIT)EXHAUST FAN WITH HEAT LAMP (VENT TO EXIT)CHIMESPUSH BUTTON SWITCHSDHDSMOKE DETECTORCOCO DETECTORHEAT DETECTORTHERMOSTATTSSPEAKER (PROVIDE ADEQUATE SUPPORT)TVTELEVISIONMELECTRIC METERELECTRIC PANELTELEPHONECOMPUTERCEILING FAN WITH LED LIGHT FIXTURE (PROVIDE ADEQUATE SUPPORT)JOB NO:DRAWN:PROJ MGR:CHECKED:ISSUE DATE:O'Brien Home Farm Single Family Uphill LotSouth Burlington, VermontE4.1.109/01/17OPTIONAL BASEMENTFINISHED ELECTRICAL39 Ledge WayOpt. Basement FinishedElectricalDAYLILYSCALE:1/4" = 1'-0" (22x34)Opt Basement Bedroom/BathPartial Elect. Basement PlanREVISIONS REF.DW3 33333 3DN33 3334DWP/GFITO SWITCH BELOWWP/GFICHANDELIERCHANDELIERGFISDCOSDSD220VGFIGFI220VGFIGFIGFIGFIGFISD COMICROOUTLETTVGAS LINEGAS LINEFLUSHFLUSHFLUSHFLUSHFLUSHFLUSH6" LED SURFACE6" LED SURFACE6" LED SURFACE6" LED SURFACE6" LED SURFACE6" LED SURFACE6" LED SURFACE6" LED SURFACE6" LED SURFACEROUGH-IN GAS LINE FOR FUTURE FIREPLACEEQ.EQ.TELECTRICAL NOTES:* PROVIDE AND INSTALL LOCALLY CERTIFIED SMOKE DETECTORS AS REQUIRED BY NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) AND MEETING THE REQUIREMENTS OF ALL GOVERNING CODES* PROVIDE AND INSTALL GROUND FAULT CIRCUIT-INTERRUPTERS (GFI) AS REQUIRED BY NATIONAL ELECTRIC CODE (NEC) AND MEETING THE REQUIREMENTS OF ALL GOVERNING CODES.* ELECTRICAL CONTRACTOR TO PROVIDE REQUIRED DIRECT HOOK-UPS/CUTOFFS.* HVAC CONTRACTOR TO VERIFY THERMOSTAT LOCATIONS.* ALL ELECTRICAL AND MECHANICAL EQUIPMENT (I.E. FURNACES, A/C UNITS, ELECTRICAL PANELS, SANITARY SUMP PITS, DRAIN TILE SUMP, AND WATER HEATERS) ARE SUBJECT TO RELOCATION DUE TO FIELD CONDITIONS.* ALL BRANCH CIRCUITS THAT SUPPLY 125 VOLT 15 & 20 AMP RECEPTACLE OUTLETS INSTALLED IN ANY HABITAL SPACE SHALL BE PROTECTED BY AN ARC FAULT CIRCUIT INTERRUPTER PER N.E.C. 210-12(A) & (B).ELECTRICAL DEVICES:ABOVE FINISHED FLOOR:SWITCHES OVER COUNTER.................. 48" TO CLWALL OUTLETS OVER COUNTER..........48" TO CLREMAINING SWITCHES...........................48" TO CLWALL OUTLETS........................................ 12" TO CLBATH VANITY BRACKET OUT(1" ABOVE TOP OF MIRROR)............80" TO CLWATER SOFTENER AND SUMP OUTLETS........................................48" TO CLTELEPHONE OUTLETS............................12" TO CLTELEVISION OUTLETS.............................12" TO CLEXTERIOR GFI OUTLETS.........................12" TO CLGARAGE GFI (ABOVE GARAGE FLOOR)12" TO CLBASEMENT WALL OUTLETS...................48" TO CLFRONT DOOR COACH LIGHT..................72" TO CLGARAGE DOOR COACH LIGHT(ABOVE GARAGE FLOOR).......................84" TO CLDINING AND BREAKFAST FIXTURE........64" TO BOTTOMOF FIXTUREFOYER AND STAIRWAY FIXTURE.......... 96" TO BOTTOMOF FIXTURETHERMOSTAT...........................................54" TO CLDOORBELL CHIMES.................................84" TO CLDOORBELL BUTTON................................LEVEL W/DOOR HANDLEKITCHEN HOOD FAN "WHIP"...................66" TO CLKITCHEN WALL HUNGMICROWAVE OUTLET..............................76" TO CLKITCHEN DISHWASHER RECEPTACLE.UNDER SINKKITCHEN RANGE......................................24" TO CLKITCHEN REFRIGERATOR......................48" TO CLWASHER/DRYER OUTLET...................... 48" TO CLCL = CENTERLINE1 = FIELD VERIFY2 = MASTER BATH STANDARD 30" HIGHVANITY TO BE RAISED 4"1,2ELECTRICAL KEY:SINGLE POLE OUTLETDUPLEX CONVENIENCE OUTLETDUPLEX OUTLET ABOVE COUNTERWEATHERPROOF DUPLEX OUTLETWPGFIGROUND-FAULT CIRCUIT-INTERRUPTER DUPLEX OUTLETHALF-SWITCHED DUPLEX OUTLETSPECIAL POURPOSE OUTLET/JUNCTION BOXUSB CHARGER/TAMPER-RESISTANT DUPLEX OUTLETUSBDUPLEX OUTLET IN FLOOR220 VOLT OUTLET220VOVERHEAD DUPLEXWALL SWITCHTHREE-WAY SWITCHFOUR-WAY SWITCHDIMMER SWITCHREINFORCED JUNCTION BOXCEILING MOUNTED LIGHT FIXTUREWALL MOUNTED LIGHT FIXTURERECESSED LIGHT FIXTURERECESSED LIGHT FIXTURE (WEATHERPROOF)WPRECESSED FLOURESCENT LIGHT FIXTURE (WEATHERPROOF)FLURRECESSED LIGHT FIXTURE (VAPOR-PROOF)VPRECESSED FLOURESCENT LIGHT FIXTURE (VAPOR-PROOF)VP/FLURPNDTCEILING MOUNTED PENDANT LIGHT FIXTUREMINICEILING MOUNTED MINI-PENDANT LIGHT FIXTURELEDCEILING MOUNTED LED LIGHT FIXTUREWALL MOUNTED LED LIGHT FIXTURELEDRECESSED LED LIGHT FIXTURELEDRECESSED ADJUSTABLE EYEBALL LED LIGHT FIXTUREEBPCLED LIGHT FIXTURE WITH PULL CHAINFLUORESCENT LIGHT FIXTUREFLUORESCENT LIGHT FIXTURE WITH PULL CHAINPCEXHAUST FAN (VENT TO EXIT)EXHAUST FAN/LIGHT COMBINATION (VENT TO EXIT)EXHAUST FAN WITH HEAT LAMP (VENT TO EXIT)CHIMESPUSH BUTTON SWITCHSDHDSMOKE DETECTORCOCO DETECTORHEAT DETECTORTHERMOSTATTSSPEAKER (PROVIDE ADEQUATE SUPPORT)TVTELEVISIONMELECTRIC METERELECTRIC PANELTELEPHONECOMPUTERCEILING FAN WITH LED LIGHT FIXTURE (PROVIDE ADEQUATE SUPPORT)JOB NO:DRAWN:PROJ MGR:CHECKED:ISSUE DATE:O'Brien Home Farm Single Family Uphill LotSouth Burlington, VermontE1.1B09/01/17MAIN FLOOR ELECTRICALPLAN-B39 Ledge WayElevation - BDAYLILYSCALE:1/4" = 1'-0" (22x34)Main Floor Electrical PlanREVISIONS JOB NO:DRAWN:PROJ MGR:CHECKED:ISSUE DATE:O'Brien Home Farm Single Family Uphill LotSouth Burlington, VermontAD.4CABINET PLANS39 Ledge WayREVISIONSDAYLILY