HomeMy WebLinkAboutZP-22-087 - 0191 Two Brothers Drive 4/13/2022
VIA HAND-DELIVERY
March 18, 2022
Ms. Dalila Hall, Administrative Officer
South Burlington Planning and Zoning
180 Market Street
South Burlington, VT 05403
Re: Zoning Permit Application 191 Two Brothers Drive, South Burlington, VT 05403
Dalila,
Further to Final Plat Permit SD-17-17, enclosed please find a zoning permit application
for 191 Two Brothers Drive, South Burlington, Vermont 05403, Unit 066 on the Final Plat/Site
Plan submitted as part of SD-17-17.
As summarized below, we are currently not requesting any identical homes or exceptions
to what has been permitted per the Final Plat Permit #SD-17-17.
Existing Proposed
Identical Elevations on adjoining lots or
across the street
No No
No Identical Elevations more than 2x
on Laurentide Ln
No No
No Identical Elevations more than 2x
on Ledge Way
Yes No
No Identical Elevations more than 2x
on Split Rock Court
No No
No Identical Elevations more than 3x
on Two Brothers Dr
No No
No Identical Elevations more than 3x
on Downhill O’Brien Farm Rd
No No
No Identical Elevations more than 3x
on uphill O’Brien Farm Rd
No No
No single-color palate more than 10x in
subdivision
No No
This application requires a sewer connection and allocation. Attached please find
required sewer and water allocation forms as well.
Please contact us with any questions or concerns.
Sincerely,
Brandon Secl, Estimator
Property Owners Name:O'Brien Farm Road, LLC
Property Location:191 Two Brothers Drive (Lot 05-66)
Amount:7,641.44 Payment Type:check #006391 Date:4/4/2022
Code
Zoning Permit (New Residential)ZP-22-087 zp Recording fee 13.00$
plus
1848 0.45$ per sq. ft. 831.60$
plus
1775 0.20$ per sq. ft. 355.00$
plus
2 50.00$ per bay 100.00$
plus
After-the fact of 50% [no NOV] or 100% [NOV] -$
Zoning Permit Total 1,299.60$
Sewer Allocation Fee WWA-22-116 #204 242.95 g.p.d x 13.06$ 3,172.93$
Bartlett Bay
x Airport Parkway
Recreation Impact Fee #220 1,665.08$
South Village Recreation Impact Fee #243 -$
Road Impact Fee #221 944.89$
Fire Impact Fee #203 -$
Police Impact Fee #222 495.94$
Dorset Street Waterline Fee #230 -$
Sewer Connection Inspection WW-22-15 ww 63.00$ 63.00$
Total (Impact Fees + Permit) 7,641.44$
Planning & Zoning Invoice
Residential Impact & Permit Fees
garage bay(s) at
Amount Due
sq. ft building at
sq. ft unfinished basement at
JOB NO:DRAWN:PROJ MGR:CHECKED:ISSUE DATE:O'Brien Home Farm Single Family Downhill LotSouth Burlington, VT 05403AGN0.109/01/17COVER SHEET, SHEETINDEXSHEET INDEXA-1AGN0.1 COVER SHEET, SHEET INDEXAGN0.2 GENERAL NOTESRANCH ELEVATION-AA0.1A FOUNDATION/ WALKOUT BASEMENT PLAN-AA1.1A MAIN FLOOR PLAN-AA3.1A EXTERIOR ELEVATIONSA4.2.1A OPT WALKOUT BASEMENT-AA4.3.1A OPT COVERED DECK-AA6.1A BUILDING SECTIONS-A2-STORY ELEVATION-ARANCH ELEVATION-BA0.1B FOUNDATION/ BASEMENT PLAN-BA1.1B MAIN FLOOR PLAN-BA3.1B EXTERIOR ELEVATIONS & ROOF PLAN-BA6.1B BUILDING SECTION-B2-STORY ELEVATION-DALL ELEVATIONSA4.1.1 FINISHED BASEMENTA4.1.2 OPT FLOOR PLANSA5.1 STAIR SECTIONSELECTRICALE0.1A BASEMENT ELECTRICAL PLAN-AE1.1A MAIN FLOOR ELECTRICAL PLAN-AE0.1B BASEMENT ELECTRICAL PLAN-BE1.1B MAIN FLOOR ELECTRICAL PLAN-BE4.1.1 OPT FINISHED BASEMENT ELECTRICAL PLANSTRUCTURES0.1A MAIN FLOOR FRAMING PLAN-AS1.1A ROOF FRAMING PLAN-AS0.1B MAIN FLOOR FRAMING PLAN-BS1.1B ROOF FRAMING PLAN-BAD.2 DETAILSAD.1 DETAILSAD.3 DETAILSSquare Footages-Ranch BELEVATION BMAIN FLOOR LIVING 1848 SFTOTAL LIVING 1848 SFPLAN OPTIONSOPT. FINISHED BASEMENT 958 SFDAISYDaisyCraftsman Elevation - BSouth Burlington, VermontO'Brien Home FarmSingle Family Downhill Lot DaisyREVISIONS
MAIN FLOORMAIN PLATET.O.F.BASEMENT FLOOR9'-1 1/8"11 1/2"8'-8"6" 12"6" 12"2152042118'-3"210223201(2) 2026 FX BLACKOUT @ 16'-6" H.H.3AD.28AD.23AD.14AD.1AD.32224207215213MAIN FLOORMAIN PLATET.O.F.BASEMENT FLOOR8'-8"11 1/2"9'-1 1/8"6" 12"6" 12"2032232112011AD.25AD.28AD.23AD.1MAIN FLOORMAIN PLATET.O.F.BASEMENT FLOOR8'-8"11 1/2"9'-1 1/8"2032012102231AD.23AD.210AD.23AD.12154'-8"18'-10 15/16"MAIN FLOORMAIN PLATET.O.F.BASEMENT FLOOR8'-8"11 1/2"9'-1 1/8"6" 12"6" 12"2032012132102111AD.28AD.210AD.23AD.12154'-8"18'-10 15/16"6" / 12"6" / 12"6" / 12"6" / 12"RAKE1'-0"EAVE TYP1'-0"RAKE TYP1'-0"CONSTRUCTION ASSEMBLIES:T THE FOLLOWING KEYNOTES REFERENCE THE SYMBOLS AS SHOWN ON PLANSA. ROOF CONSTRUCTION:COMPOSITION ROOF SHINGLES ON UNDERLAYMENT ON ROOF SHEATHING ON ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD OVER MOISTURE VAPOR RETARDER WITH INSULATION ABOVE.B1. TYPICAL SIDING WALL CONSTRUCTION:SIDING ON WATER RESISTANT BARRIER ON EXTERIOR WALL SHEATHING ON 2x4 STUDS, 16" O.C. OR 2x6 STUDS, 24" O.C. W/ INSULATION IN CAVITIES.INTERIOR: 1/2" GYPSUM BOARD OVER MOISTURE VAPOR RETARDER.B2. TYPICAL STONE VENEER WALL CONSTRUCTION:ADHERED SYNTHETIC STONE VENEER (INSTALLED PER MFR'S SPECS.) OVER WATER RESISTANT BARRIER ON EXTERIOR WALL SHEATHING ON 2x4 STUDS, 16" O.C. OR 2x6 STUDS, 24" O.C. W/ INSULATION IN CAVITIES.INTERIOR: 1/2" GYPSUM BOARD OVER MOISTURE VAPOR RETARDER.C. TYPICAL FLOOR CONSTRUCTION:FINISHED FLOORING ON 3/4" FLOOR SHEATHING ON FLOOR FRAMING AS NOTED ON STRUCTURAL DRAWINGS.MAIN FLOOR CEILING: 1/2" GYPSUM BOARD.D. CONCRETE SLAB CONSTRUCTION:4" CONCRETE SLAB OVER 6 MIL. POLYETHYLENE VAPOR BARRIER OVER 4" MINIMUM GRANULAR FILL.GENERAL EXTERIOR ELEVATION NOTES:* GRADE CONDITIONS MAY VARY FOR INDIVIDUAL SITE FROM THAT SHOWN.* PROVIDE ROOF AND SOFFIT VENTS AS SPECIFIED BY BUILDER.* PROVIDE GUTTERS AND DOWNSPOUTS AS SPECIFIED BY BUILDER.JOB NO:DRAWN:PROJ MGR:CHECKED:ISSUE DATE:O'Brien Home Farm Single Family Downhill LotSouth Burlington, VT 05403A3.1B09/01/17EXTERIOR ELEVATIONS &ROOF PLAN-BSCALE:1/4" = 1'-0" (22x34)Front ElevationSCALE:1/8" = 1'-0" (22x34)Rear Elevation-ASCALE:1/8" = 1'-0" (22x34)Right ElevationSCALE:1/8" = 1'-0" (22x34)Left ElevationSCALE:1/8" = 1'-0" (22x34)Roof PlanElevation - CraftsmanDAISYKEYNOTES:EXTERIOR ELEVATION201 ROOFING PER BUILDER SPEC.203 6" LAP SIDING.204 SHAKE SIDING.205 BOARD & BATTEN SIDING.207 PANEL SIDING.210 ALUMINUM WRAPPED 2x8 FASCIA.211 ALUMINUM WRAPPED 2x8 RAKE.213 5/4x4 TRIM.214 5/4x6 TRIM.215 5/4x8 TRIM.223 5/4x6 FRIEZE TRIM.224 BRACKET- FYPON BKT16X18X3 OR EQUALNOTE:* REQUIRED NET FREE VENTED AREAS ARE CALCULATED BY MULTIPLYING THE ACTUAL ATTIC AREA (SQ FT) IN COLUMN 1 BY 1/300 ANDMULTIPLYING SUM BY 144 SQ IN/SQ FT 40%-50% OF TOTAL NET FREE VENTED AREA IS REQUIRED AT THE RIDGE (HIGH) AND THE REMAININGIS THE REQUIRED IN THE SOFFIT (LOW). WHEN NO "HIGH/LOW" VENTING IS PROVIDED, THE REQUIRED NET FREE AREA IS 1/150 OF THEACTUAL AREA AND 100% OF THIS VENTED AREA SHALL BE PROVIDED AT THE SOFFIT.** ACTUAL NET FREE VENTED SOFFIT AREAS ARE CALCULATED BY DIVIDING THE REQUIRED NET FREE VENTED SOFFIT AREA (FT) BY THEMANUFACTURERS STATED ACTUAL VENTED NET FREE AREA PER VENT. WHEN APPLICABLE, THE ACTUAL TOTAL NUMBER OF SOFFIT VENTSSHALL BE DIVIDED EQUALLY BETWEEN EACH EAVE AND SPACED AN EQUAL DISTANCE APART FROM ONE ANOTHER.ACTUAL NET FREE VENTED RIDGE AREAS ARE CALCULATED BY DIVIDING THE REQUIRED NET FREE VENTED RIDGE AREA (FT) BY THEMANUFACTURERS STATED ACTUAL VENTED NET FREE AREA PER VENT.ATTIC VENTILATION SCHEDULE (ELEVATION B)AREAATTIC AREA(SQ FT)TOTAL NET VENTED(1/300) (SQ IN)TOTAL NET VENTED(1/150) (SQ IN)*LOWER VENT(50%)*LOWER VENT(60%)*UPPER VENT(40%)*UPPER VENT(50%)MAIN ROOF 2457 SF 1179 in² 2359 in² 590 in² 708 in² 472 in² 590 in²REVISIONS
33Covered Deck39'-0"12'-0"27'-0"10'-0"10'-0"8"9'-4"8"9'-4"8" 10'-8" 8"130Owners SuiteFamilyDiningWP/ GFI2-2x12 BEAM DROPPED2-2x12 BEAM DROPPEDROOF TRUSSES @ 24" O.C.6" / 12"8" / 12"8" / 12"RAKE TYP6"EAVE TYP1'-0"MAIN FLOORMAIN PLATET.O.F.BASEMENT FLOOR8'-8"11 1/2"9'-1 1/8"201210215MAIN FLOORMAIN PLATET.O.F.BASEMENT FLOOR8'-8"11 1/2"9'-1 1/8"8" 12"8" 12"2112232032158AD.28'-0"MAIN FLOORMAIN PLATET.O.F.BASEMENT FLOOR8'-8"11 1/2"9'-1 1/8"2012109AD.2215CONSTRUCTION ASSEMBLIES:T THE FOLLOWING KEYNOTES REFERENCE THE SYMBOLS AS SHOWN ON PLANSA. ROOF CONSTRUCTION:COMPOSITION ROOF SHINGLES ON UNDERLAYMENT ON ROOF SHEATHING ON ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD OVER MOISTURE VAPOR RETARDER WITH INSULATION ABOVE.B1. TYPICAL SIDING WALL CONSTRUCTION:SIDING ON WATER RESISTANT BARRIER ON EXTERIOR WALL SHEATHING ON 2x4 STUDS, 16" O.C. OR 2x6 STUDS, 24" O.C. W/ INSULATION IN CAVITIES.INTERIOR: 1/2" GYPSUM BOARD OVER MOISTURE VAPOR RETARDER.B2. TYPICAL STONE VENEER WALL CONSTRUCTION:ADHERED SYNTHETIC STONE VENEER (INSTALLED PER MFR'S SPECS.) OVER WATER RESISTANT BARRIER ON EXTERIOR WALL SHEATHING ON 2x4 STUDS, 16" O.C. OR 2x6 STUDS, 24" O.C. W/ INSULATION IN CAVITIES.INTERIOR: 1/2" GYPSUM BOARD OVER MOISTURE VAPOR RETARDER.C. TYPICAL FLOOR CONSTRUCTION:FINISHED FLOORING ON 3/4" FLOOR SHEATHING ON FLOOR FRAMING AS NOTED ON STRUCTURAL DRAWINGS.MAIN FLOOR CEILING: 1/2" GYPSUM BOARD.D. CONCRETE SLAB CONSTRUCTION:4" CONCRETE SLAB OVER 6 MIL. POLYETHYLENE VAPOR BARRIER OVER 4" MINIMUM GRANULAR FILL.BASEMENT PLAN NOTES:* SEE BASEMENT PLAN SHEETS FOR ADDITIONAL INFORMATIONFLOOR PLAN NOTES:* SEE FLOOR PLAN SHEETS FOR ADDITIONAL INFORMATIONELECTRICAL NOTES :* SEE ELECTRICAL PLAN SHEETS FOR ADDITIONAL INFORMATIONELEVATION NOTES :* SEE ELEVATION SHEETS FOR ADDITIONAL INFORMATIONJOB NO:DRAWN:PROJ MGR:CHECKED:ISSUE DATE:O'Brien Home Farm Single Family Downhill LotSouth Burlington, VT 05403A4.3.1A09/01/17OPT COVERED DECK-ASCALE:1/4" = 1'-0" (22x34)Partial Main Floor PlanSCALE:1/8" = 1'-0" (22x34)Partial Roof PlanSCALE:1/8" = 1'-0" (22x34)Left ElevationSCALE:1/8" = 1'-0" (22x34)Rear ElevationSCALE:1/8" = 1'-0" (22x34)Right ElevationElevation - A Optional Covered DeckAll Elevations SimilarDAISYREVISIONS
FD8' -9" CLGStorage1A5.1UP 15 RISERSW.H.FURN.8" 12'-4" 5'-0" 1'-0"8"8" 16'-4" 2'-4"22'-4"6'-0"6'-0"Unexcavated5'-5 1/2"7'-3 1/2"3'-8 3/4"4"10'-11 3/4"5'-0 1/4"8"6'-0"F-2F-2F-2 F-219'-8"19'-4"39'-0"1481488" 5'-8" 6'-0" 5'-8" 8"F-2 F-2F-2F-2F-2 F-2 F-2F-2F-2F-2F-2F-C 2X6 BEARING WALL8" 10'-7" 6'-8 3/4" 3'-7 1/2" 5'-7" 5'-7" 5'-6 3/4" 8"14814810'-4 1/4" 5'-7" 5'-7"147W-8 TYPF-P F-P F-P1A6.1B10'-9 1/2"6'-0" 11'-8"14'-4"37'-8"3'-1 3/4" 2'-10 3/4" 1'-9"7'-7 1/4"60'-0"10'-0"12'-0"210686068 French3050 DH 3050 DH3050 DH 3050 DHCONSTRUCTION ASSEMBLIES:T THE FOLLOWING KEYNOTES REFERENCE THE SYMBOLS AS SHOWN ON PLANSA. ROOF CONSTRUCTION:COMPOSITION ROOF SHINGLES ON UNDERLAYMENT ON ROOF SHEATHING ON ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD OVER MOISTURE VAPOR RETARDER WITH INSULATION ABOVE.B1. TYPICAL SIDING WALL CONSTRUCTION:SIDING ON WATER RESISTANT BARRIER ON EXTERIOR WALL SHEATHING ON 2x4 STUDS, 16" O.C. OR 2x6 STUDS, 24" O.C. W/ INSULATION IN CAVITIES.INTERIOR: 1/2" GYPSUM BOARD OVER MOISTURE VAPOR RETARDER.B2. TYPICAL STONE VENEER WALL CONSTRUCTION:ADHERED SYNTHETIC STONE VENEER (INSTALLED PER MFR'S SPECS.) OVER WATER RESISTANT BARRIER ON EXTERIOR WALL SHEATHING ON 2x4 STUDS, 16" O.C. OR 2x6 STUDS, 24" O.C. W/ INSULATION IN CAVITIES.INTERIOR: 1/2" GYPSUM BOARD OVER MOISTURE VAPOR RETARDER.C. TYPICAL FLOOR CONSTRUCTION:FINISHED FLOORING ON 3/4" FLOOR SHEATHING ON FLOOR FRAMING AS NOTED ON STRUCTURAL DRAWINGS.MAIN FLOOR CEILING: 1/2" GYPSUM BOARD.D. CONCRETE SLAB CONSTRUCTION:4" CONCRETE SLAB OVER 6 MIL. POLYETHYLENE VAPOR BARRIER OVER 4" MINIMUM GRANULAR FILL.GENERAL BASEMENT PLAN NOTES:* ALL UNDIMENSIONED PARTITIONS ( ) ARE 3 1/2" ROUGH UNLESS NOTED OTHERWISE.* IF MAIN FLOOR FRAMING IS TO BE INSTALLED BEFORE CONCRETE FLOOR, PROVIDE THE FOLLOWING:** AT PAD FOOTINGS, PROVIDE 8"x8" CONCRETE PEDESTAL FLUSH WITH CONCRETE FLOOR FOR ATTACHMENT OF POST BASE** AT CONTINUOUS FOOTINGS UNDER FRAMING BEARING WALLS, PROVIDE 6" WIDE CONTINUOUS CONCRETE STEM, TOP OF STEM FLUSH WITH CONCRETE FLOOR & CENTERED ON FOOTING.* ALL ANGLED PARTITIONS ARE 45 DEGREES UNLESS NOTED OTHERWISE.* ALL EXTERIOR DIMENSIONS ARE TO FACE OF STUDS UNLESS NOTED OTHERWISE.* WINDOW SUPPLIER TO VERIFY AT LEAST ONE WINDOW IN ALL BEDROOMS MEETS ALL EMERGENCY EGRESS REQUIREMENTS.* ALL ELECTRICAL AND MECHANICAL EQUIPMENT, METER LOCATIONS, ETC SHALL BE CONFIRMED BY MECHANICAL AND ELECTRICAL CONTRACTORS. CONTRACTORS SHALL COORDINATE WITH BUILDER PRIOR TO RELOCATION OF EQUIPMENT AND METERS.* ALL TRUSSES TO BEAR ON EXTERIOR WALLS AND/OR GIRDER TRUSS UNLESS NOTED OTHERWISE.* TRUSS MFG. TO SIZE MEMBERS, FASTENERS, HANGERS & SET SPACING FOR ALL TRUSSES.* FOR ADDITIONAL INFORMATION SEE GENERAL NOTES AND DETAILS.* TYPICAL WINDOW HEAD HEIGHTS SHALL BE 7'-0" A.F.F. (U.N.O.)SYMBOLTYPESIZEFOOTING SCHEDULEF-PPIER (EXTERIOR)REINFORCING12" SONOTUBE W/ BELL BOTTOMNAF-C CONTINOUS FOOTING2'-0" WIDE x 0'-8" DEEP 3-#4's CONTINUOUSF-2PAD FOOTING (INTERIOR) 2'-0" x 2'-0" x 1'-0" DEEP NACOLUMN6x6 TREATED POSTNA*NOTE: LALLY COLUMNS SHALL HAVE THE ALLOWABLE MINIMUM LOAD CAPACITY OUTLINED IN THE GENERAL NOTES. SEE GENERAL NOTES FOR BOTTOM AND TOP BEARING PLATES.COMMENTS48" MIN. BELOW FINISH GRADE3 1/2" LALLY COLUMN UNLESS NOTED OTHERWISE*SYMBOLWALL THICKNESSWALL HEIGHTFOUNDATION WALL SCHEDULEW-8 8" 9'-0"REINFORCING2 #4 BARS TOP & BOTTOM*CONTINUOUS FOOTING1'-4"x 0'-8" W/ 2-#4's CONTINUOUS*IF FOOTING IS BEARING ON EARTH BUILDER TO VERIFY SOIL PRESSURE AND USE 2'-0"x0'-8" CONTINUOUS FOOTINGJOB NO:DRAWN:PROJ MGR:CHECKED:ISSUE DATE:O'Brien Home Farm Single Family Downhill LotSouth Burlington, VT 05403A0.1B09/01/17FOUNDATION/ BASEMENTPLAN-BSCALE:1/4" = 1'-0" (22x34)Foundation/ Basement PlanElevation - BDAISYKEYNOTES:FLOOR PLAN101 SINK W/ GARBAGE DISPOSAL.102 DISHWASHER.103 REFRIGERATOR.104 RANGE W/ HOOD/MICRO.107 PANTRY SHELVES PER BUILDER SPEC.108 BASE CABINETS.109 UPPER CABINETS.110 WATER CLOSET.111 LAV. SINK.113 SHOWER (SIZE PER PLAN).115 DROP IN TUB W/ PLATFORM.116 TUB/SHOWER (SIZE PER PLAN).117 LINEN SHELVES PER BUILDER SPEC.118 WASHER.119 DRYER.121 LINE OF SHELF ABOVE.122 ROD & SHELF.123 ATTIC ACCESS (22"x30" U.N.O.).124 HANDRAIL.125 SOLID CORE DOOR W/ SELF CLOSER.126 LINE OF OVERHEAD GARAGE DOOR INOPEN POSITION.127 PROVIDE 5/8" TYPE "X" GYPSUM BOARD INGARAGE AS REQUIRED BY CODE.128 SLOPE GARAGE FLOOR 1/8" PER FOOTTOWARD GARAGE DOOR OPENING.130 LINE OF SOFFIT ABOVE (REFER TOEXTERIOR ELEVATIONS FOR HEIGHTSAND DETAILS).131 GYPSUM BOARD SOFFIT (HEIGHT ASNOTED).135 PREFABRICATED FIREPLACE, GAS(NON-WOOD BURNING) AS SPECIFIED BYBUILDER.137 42" HIGH EXTERIOR GUARDRAIL W/BALUSTERS TO BE SPACED SUCH THAT 4"SPHERE CANNOT PASS BETWEENBALUSTERS.141 2x4 HALF WALL @ 42" A.F.F. W/ WOODCAP.146 WINDOW WELL AS SPECIFIED BY BUILDER147 LINE OF DECK ABOVE.148 BEAM POCKET.150 TOILET PAPER HOLDER 19" MIN A.F.F.151 TOWEL BAR 48" A.F.F.152 TOWEL RING 48" A.F.F.REVISIONS
FD8' -9" CLGFamily8' -9" CLGBedroom8' -9" CLGUnfinished BasementUnexcavated8' -9" CLGStorageBathFURN.2068246826685068 SLD210685'-3 1/2"19'-9"9'-10 1/2" 8" 9'-10 1/2" 8" 3'-7 1/2" 2'-10" 6'-4 1/2" 3'-0"8" 4 1/2" 17'-1" 3'-4" 16'-10 1/2"8"8"23'-8 1/2"5 1/2"3'-9 1/2"2'-1 1/2"3'-6"4"14'-11"3'-6"8"8"18'-7"2'-0"3'-9 1/2"11011611111712213133"x60"20'-8 1/2"2'-4 1/2" 13'-10"7'-6" SOFFIT 7'-6" SOFFIT1412x6 WALL7'-6" SOFFIT1311511501528'-4 1/2"12'-2"ADD GRAB BAR REINFORCINGDETAIL 8, AD.17'-10" CLG6'-0" 11'-8"14'-4"39'-0"37'-5 1/2"22'-6 1/2"6'-0"18'-8"6'-0"1'-8 1/2"20'-4"4'-8"6'-0"22'-4"20'-5"36'-6 1/2"210686068 French3050 DH 3050 DH3050 DH 3050 DH10'-6"16'-9 1/2"13'-10"CONSTRUCTION ASSEMBLIES:T THE FOLLOWING KEYNOTES REFERENCE THE SYMBOLS AS SHOWN ON PLANSA. ROOF CONSTRUCTION:COMPOSITION ROOF SHINGLES ON UNDERLAYMENT ON ROOF SHEATHING ON ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD OVER MOISTURE VAPOR RETARDER WITH INSULATION ABOVE.B1. TYPICAL SIDING WALL CONSTRUCTION:SIDING ON WATER RESISTANT BARRIER ON EXTERIOR WALL SHEATHING ON 2x4 STUDS, 16" O.C. OR 2x6 STUDS, 24" O.C. W/ INSULATION IN CAVITIES.INTERIOR: 1/2" GYPSUM BOARD OVER MOISTURE VAPOR RETARDER.B2. TYPICAL STONE VENEER WALL CONSTRUCTION:ADHERED SYNTHETIC STONE VENEER (INSTALLED PER MFR'S SPECS.) OVER WATER RESISTANT BARRIER ON EXTERIOR WALL SHEATHING ON 2x4 STUDS, 16" O.C. OR 2x6 STUDS, 24" O.C. W/ INSULATION IN CAVITIES.INTERIOR: 1/2" GYPSUM BOARD OVER MOISTURE VAPOR RETARDER.C. TYPICAL FLOOR CONSTRUCTION:FINISHED FLOORING ON 3/4" FLOOR SHEATHING ON FLOOR FRAMING AS NOTED ON STRUCTURAL DRAWINGS.MAIN FLOOR CEILING: 1/2" GYPSUM BOARD.D. CONCRETE SLAB CONSTRUCTION:4" CONCRETE SLAB OVER 6 MIL. POLYETHYLENE VAPOR BARRIER OVER 4" MINIMUM GRANULAR FILL.BASEMENT PLAN NOTES:* SEE BASEMENT PLAN SHEETS FOR ADDITIONAL INFORMATIONFLOOR PLAN NOTES:* SEE FLOOR PLAN SHEETS FOR ADDITIONAL INFORMATIONELECTRICAL NOTES :* SEE ELECTRICAL PLAN SHEETS FOR ADDITIONAL INFORMATIONELEVATION NOTES :* SEE ELEVATION SHEETS FOR ADDITIONAL INFORMATIONJOB NO:DRAWN:PROJ MGR:CHECKED:ISSUE DATE:O'Brien Home Farm Single Family Downhill LotSouth Burlington, VT 05403A4.1.109/01/17FINISHED BASEMENTSCALE:1/4" = 1'-0" (22x34)Finished Basement PlanDAISYREVISIONS
DWCONSTRUCTION ASSEMBLIES:T THE FOLLOWING KEYNOTES REFERENCE THE SYMBOLS AS SHOWN ON PLANSA. ROOF CONSTRUCTION:COMPOSITION ROOF SHINGLES ON UNDERLAYMENT ON ROOF SHEATHING ON ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD OVER MOISTURE VAPOR RETARDER WITH INSULATION ABOVE.B1. TYPICAL SIDING WALL CONSTRUCTION:SIDING ON WATER RESISTANT BARRIER ON EXTERIOR WALL SHEATHING ON 2x4 STUDS, 16" O.C. OR 2x6 STUDS, 24" O.C. W/ INSULATION IN CAVITIES.INTERIOR: 1/2" GYPSUM BOARD OVER MOISTURE VAPOR RETARDER.B2. TYPICAL STONE VENEER WALL CONSTRUCTION:ADHERED SYNTHETIC STONE VENEER (INSTALLED PER MFR'S SPECS.) OVER WATER RESISTANT BARRIER ON EXTERIOR WALL SHEATHING ON 2x4 STUDS, 16" O.C. OR 2x6 STUDS, 24" O.C. W/ INSULATION IN CAVITIES.INTERIOR: 1/2" GYPSUM BOARD OVER MOISTURE VAPOR RETARDER.C. TYPICAL FLOOR CONSTRUCTION:FINISHED FLOORING ON 3/4" FLOOR SHEATHING ON FLOOR FRAMING AS NOTED ON STRUCTURAL DRAWINGS.MAIN FLOOR CEILING: 1/2" GYPSUM BOARD.D. CONCRETE SLAB CONSTRUCTION:4" CONCRETE SLAB OVER 6 MIL. POLYETHYLENE VAPOR BARRIER OVER 4" MINIMUM GRANULAR FILL.3060 DH3060 DH3060 DH3060 DH2040 DH3060 DH 3060 DH3060 DH3060 DH 3060 DH16080 OGD30683060 SH3060 SH21068210682106826682106826682106821068246824685068 SLD6068 French39'-0"12'-0"27'-0"25'-5 1/2"13'-6 1/2"76'-0"10'-0"60'-0"6'-0"21'-2 1/2"4'-7 1/2"11'-4 1/2"8'-9"2'-2 1/2"11'-10"4'-4"1'-8"6'-6"14'-8 1/2"5'-6 1/2" 5'-10"16'-10 1/2"4'-3 1/2"5'-6 1/2"3'-10 1/2"7'-1"1'-10" 5'-3"9' -0" CLGBedroom 29' -0" CLGFoyer9' -0" CLGBath 22 Car Garage9' -0" CLGFlex9' -0" CLGO.E.9' -0" CLGLaundry9' -0" CLGW.I.C.9' -0" CLGOwners Bath9' -0" CLGOwners Suite9' -0" CLGFamily9' -0" CLGDining9' -0" CLGKitchenDeckPorch1A5.1PANTRYDN 15 RISERSDN AS REQ'DDN AS REQ'D2106813'-4" 4'-8"21'-0"6'-8" 6'-8" 2'-4" 2'-4" 10'-6"10'-6"37'-8"22'-4"6'-0"OPTOPT1'-8" 4'-4"1'-8" 10'-0" 1'-8" 4'-8" 1'-8"3010 TRN ABV6010 TRN ABV.6'-0" 11'-8" 7'-9 1/2" 6'-6 1/2" 7'-0"6'-0"39'-0"2068HALF WALL1'-11 1/2"13010910810410110810210810910810910310710711611711011112212212212111811911011712212212211111111313536"x48"1301261271281252'-4" 2'-3 1/2" 8'-5" 4'-8" 3'-3 1/2" 7'-9 1/2" 6'-0 1/2"3'-3"5'-3 1/2" 1'-3" 2'-4 1/2" 3'-9 1/2" 5'-1 1/2"20'-3"5'-0" 3'-11 1/2" 8'-0 1/2" 10"12'-10" 8" 4'-8" 3'-3 1/2" 5'-4 1/2" 4'-7 1/2"1'-10"5'-3"11'-4 1/2" 4'-9" 2'-0 1/2" 3'-6" 8" 10'-5" 11 1/2" 2'-4 1/2"23'-0"22'-8 1/2"2'-3 1/2" 3'-9 1/2" 9'-3 1/2"4'-11 1/2"7'-0 1/2"4'-6"8"3'-6"10'-1"6'-11"2'-4"2'-3 1/2"1241231A6.1B2X6 WALL2X6 WALL2X6 WALL33"x60"1082X6 WALL2X6 WALL2X6 WALL19'-8"19'-4"76'-0"152151150150151152152BenchDrop Zone6'-1"10910812'-0"GENERAL FLOOR PLAN NOTES:* ALL UNDIMENSIONED PARTITIONS ( ) ARE 3 1/2" ROUGH UNLESS NOTED OTHERWISE.* ALL EXTERIOR DIMENSIONS ARE TO FACE OF STUDS UNLESS NOTED OTHERWISE.* ALL ANGLED PARTITIONS ARE 45 DEGREES UNLESS NOTED OTHERWISE.* WINDOW SUPPLIER TO VERIFY AT LEAST ONE WINDOW IN ALL BEDROOMS MEETS ALL EMERGENCY EGRESS REQUIREMENTS.* ALL ELECTRICAL AND MECHANICAL EQUIPMENT, METER LOCATIONS, ETC. SHALL BE CONFIRMED BY MECHANICAL AND ELECTRICAL CONTRACTORS. CONTRACTORS SHALL COORDINATE WITH BUILDER PRIOR TO RELOCATION OF EQUIPMENT AND METERS.* ALL TRUSSES TO BEAR ON EXTERIOR WALLS AND/OR GIRDER TRUSS UNLESS NOTED OTHERWISE.* TRUSS MFG. TO SIZE MEMBERS, FASTENERS, HANGERS & SET SPACING FOR ALL TRUSSES.* FOR ADDITIONAL INFORMATION SEE GENERAL NOTES AND DETAILS.* TYPICAL WINDOW HEAD HEIGHTS SHALL BE 8'-0 7/8" A.F.F. (U.N.0.) W/ 9'-1 1/8" CLG. AND 7'-0 7/8" A.F.F (U.N.O.) W/ 8'-1 1/8" CLG.* PROVIDE BLOCKING FOR ALL GRAB BARS IN BATHS, SEE DETAILS.JOB NO:DRAWN:PROJ MGR:CHECKED:ISSUE DATE:O'Brien Home Farm Single Family Downhill LotSouth Burlington, VT 05403A1.1B09/01/17MAIN FLOOR PLAN-BSCALE:1/4" = 1'-0" (22x34)Main Floor PlanElevation - BDAISYKEYNOTES:FLOOR PLAN101 SINK W/ GARBAGE DISPOSAL.102 DISHWASHER.103 REFRIGERATOR.104 RANGE W/ HOOD/MICRO.107 PANTRY SHELVES PER BUILDER SPEC.108 BASE CABINETS.109 UPPER CABINETS.110 WATER CLOSET.111 LAV. SINK.113 SHOWER (SIZE PER PLAN).115 DROP IN TUB W/ PLATFORM.116 TUB/SHOWER (SIZE PER PLAN).117 LINEN SHELVES PER BUILDER SPEC.118 WASHER.119 DRYER.121 LINE OF SHELF ABOVE.122 ROD & SHELF.123 ATTIC ACCESS (22"x30" U.N.O.).124 HANDRAIL.125 SOLID CORE DOOR W/ SELF CLOSER.126 LINE OF OVERHEAD GARAGE DOOR INOPEN POSITION.127 PROVIDE 5/8" TYPE "X" GYPSUM BOARD INGARAGE AS REQUIRED BY CODE.128 SLOPE GARAGE FLOOR 1/8" PER FOOTTOWARD GARAGE DOOR OPENING.130 LINE OF SOFFIT ABOVE (REFER TOEXTERIOR ELEVATIONS FOR HEIGHTSAND DETAILS).131 GYPSUM BOARD SOFFIT (HEIGHT ASNOTED).135 PREFABRICATED FIREPLACE, GAS(NON-WOOD BURNING) AS SPECIFIED BYBUILDER.137 42" HIGH EXTERIOR GUARDRAIL W/BALUSTERS TO BE SPACED SUCH THAT 4"SPHERE CANNOT PASS BETWEENBALUSTERS.141 2x4 HALF WALL @ 42" A.F.F. W/ WOODCAP.146 WINDOW WELL AS SPECIFIED BY BUILDER147 LINE OF DECK ABOVE.148 BEAM POCKET.150 TOILET PAPER HOLDER 19" MIN A.F.F.151 TOWEL BAR 48" A.F.F.152 TOWEL RING 48" A.F.F.REVISIONS
333344333443CONSTRUCTION ASSEMBLIES:T THE FOLLOWING KEYNOTES REFERENCE THE SYMBOLS AS SHOWN ON PLANSA. ROOF CONSTRUCTION:COMPOSITION ROOF SHINGLES ON UNDERLAYMENT ON ROOF SHEATHING ON ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD OVER MOISTURE VAPOR RETARDER WITH INSULATION ABOVE.B1. TYPICAL SIDING WALL CONSTRUCTION:SIDING ON WATER RESISTANT BARRIER ON EXTERIOR WALL SHEATHING ON 2x4 STUDS, 16" O.C. OR 2x6 STUDS, 24" O.C. W/ INSULATION IN CAVITIES.INTERIOR: 1/2" GYPSUM BOARD OVER MOISTURE VAPOR RETARDER.B2. TYPICAL STONE VENEER WALL CONSTRUCTION:ADHERED SYNTHETIC STONE VENEER (INSTALLED PER MFR'S SPECS.) OVER WATER RESISTANT BARRIER ON EXTERIOR WALL SHEATHING ON 2x4 STUDS, 16" O.C. OR 2x6 STUDS, 24" O.C. W/ INSULATION IN CAVITIES.INTERIOR: 1/2" GYPSUM BOARD OVER MOISTURE VAPOR RETARDER.C. TYPICAL FLOOR CONSTRUCTION:FINISHED FLOORING ON 3/4" FLOOR SHEATHING ON FLOOR FRAMING AS NOTED ON STRUCTURAL DRAWINGS.MAIN FLOOR CEILING: 1/2" GYPSUM BOARD.D. CONCRETE SLAB CONSTRUCTION:4" CONCRETE SLAB OVER 6 MIL. POLYETHYLENE VAPOR BARRIER OVER 4" MINIMUM GRANULAR FILL.9' -0" CLGOwners Bath9' -0" CLGW.I.C.5'-10"4'-0"3'-10 1/2"2'-10"3'-0"4040 FXTEMP.7'-9 1/2" 9'-9"11311511736"x48"WPWP9' -0" CLGKitchen9' -0" CLGStudy9' -0" CLGFoyer9' -0" CLGBath 220685"3'-0"3'-4" 3 1/2"9' -0" CLGKitchen9' -0" CLGBedroom 39' -0" CLGBath 29' -0" CLGFoyer5068 SLD210685 1/4"3'-0"8 3/4"3'-9 1/2"7'-7"5'-9" 3'-4" 3 1/2" 3'-10" 8" 3'-7 1/2" 9 1/2"11'-1 1/2" 2'-4 1/2"122SD9' -0" CLGFamily4'-6"7'-0 1/2"4'-6"8"1211211351'-8"BASEMENT PLAN NOTES:* SEE BASEMENT PLAN SHEETS FOR ADDITIONAL INFORMATIONFLOOR PLAN NOTES:* SEE FLOOR PLAN SHEETS FOR ADDITIONAL INFORMATIONELECTRICAL NOTES :* SEE ELECTRICAL PLAN SHEETS FOR ADDITIONAL INFORMATIONELEVATION NOTES :* SEE ELEVATION SHEETS FOR ADDITIONAL INFORMATIONJOB NO:DRAWN:PROJ MGR:CHECKED:ISSUE DATE:O'Brien Home Farm Single Family Downhill LotSouth Burlington, VT 05403A4.1.209/01/17OPT FLOOR PLANSSCALE:1/4" = 1'-0" (22x34)Opt Owners BathPartial Main Floor PlanSCALE:1/4" = 1'-0" (22x34)Opt StudyPartial Main Floor PlanSCALE:1/4" = 1'-0" (22x34)Opt Bedroom 3Partial Main Floor PlanSCALE:1/4" = 1'-0" (22x34)Opt Fireplace Built-InsPartial Main Floor PlanPlan OptionsDAISYREVISIONS
34DFD33ELECTRICAL KEY:SINGLE POLE DUPLEX CONVENIENCE OUTLETDUPLEX OUTLET ABOVE COUNTERWEATHERPROOF DUPLEX OUTLETWPGFIGROUND-FAULT CIRCUIT-INTERRUPTER DUPLEX OUTLETHALF-SWITCHED DUPLEX OUTLETSPECIAL POURPOSE OUTLET/JUNCTION BOXUSB CHARGER/TAMPER-RESISTANT DUPLEX OUTLETUSBDUPLEX OUTLET IN FLOOR220 VOLT OUTLET220VOVERHEAD DUPLEXWALL SWITCHTHREE-WAY SWITCHFOUR-WAY SWITCHDIMMER SWITCHREINFORCED JUNCTION BOXCEILING MOUNTED LIGHT FIXTUREWALL MOUNTED LIGHT FIXTURERECESSED LIGHT FIXTURERECESSED LIGHT FIXTURE (WEATHERPROOF)WPRECESSED FLOURESCENT LIGHT FIXTURE (WEATHERPROOF)FLURECESSED LIGHT FIXTURE (VAPOR-PROOF)VPRECESSED FLOURESCENT LIGHT FIXTURE (VAPOR-PROOF)VP/FLUPNDTCEILING MOUNTED PENDANT LIGHT FIXTUREMINICEILING MOUNTED MINI-PENDANT LIGHT FIXTURELEDCEILING MOUNTED LED LIGHT FIXTUREWALL MOUNTED LED LIGHT FIXTURELEDRECESSED LED LIGHT FIXTURELEDRECESSED ADJUSTABLE EYEBALL LED LIGHT FIXTUREEBPCLED LIGHT FIXTURE WITH PULL CHAINFLUORESCENT LIGHT FIXTUREFLUORESCENT LIGHT FIXTURE WITH PULL CHAINPCEXHAUST FAN (VENT TO EXIT)EXHAUST FAN/LIGHT COMBINATION (VENT TO EXIT)EXHAUST FAN WITH HEAT LAMP (VENT TO EXIT)CHIMESPUSH BUTTON SWITCHSDHDSMOKE DETECTORCOCO DETECTORHEAT DETECTORTHERMOSTATTSSPEAKER (PROVIDE ADEQUATE SUPPORT)TVTELEVISIONMELECTRIC METERELECTRIC PANELTELEPHONECOMPUTERCEILING FAN WITH LED LIGHT FIXTURE (PROVIDE ADEQUATE SUPPORT)ELECTRICAL NOTES:* PROVIDE AND INSTALL LOCALLY CERTIFIED SMOKE DETECTORS AS REQUIRED BY NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) AND MEETING THE REQUIREMENTS OF ALL GOVERNING CODES* PROVIDE AND INSTALL GROUND FAULT CIRCUIT-INTERRUPTERS (GFI) AS REQUIRED BY NATIONAL ELECTRIC CODE (NEC) AND MEETING THE REQUIREMENTS OF ALL GOVERNING CODES.* ELECTRICAL CONTRACTOR TO PROVIDE REQUIRED DIRECT HOOK-UPS/CUTOFFS.* HVAC CONTRACTOR TO VERIFY THERMOSTAT LOCATIONS.* ALL ELECTRICAL AND MECHANICAL EQUIPMENT (I.E. FURNACES, A/C UNITS, ELECTRICAL PANELS, SANITARY SUMP PITS, DRAIN TILE SUMP, AND WATER HEATERS) ARE SUBJECT TO RELOCATION DUE TO FIELD CONDITIONS.* ALL BRANCH CIRCUITS THAT SUPPLY 125 VOLT 15 & 20 AMP RECEPTACLE OUTLETS INSTALLED IN ANY HABITAL SPACE SHALL BE PROTECTED BY AN ARC FAULT CIRCUIT INTERRUPTER PER N.E.C. 210-12(A) & (B).ELECTRICAL DEVICES:ABOVE FINISHED FLOOR:SWITCHES OVER COUNTER.................. 48" TO CLWALL OUTLETS OVER COUNTER..........48" TO CLREMAINING SWITCHES...........................48" TO CLWALL OUTLETS........................................ 12" TO CLBATH VANITY BRACKET OUT(1" ABOVE TOP OF MIRROR)............80" TO CLWATER SOFTENER AND SUMP OUTLETS........................................48" TO CLTELEPHONE OUTLETS............................12" TO CLTELEVISION OUTLETS.............................12" TO CLEXTERIOR GFI OUTLETS.........................12" TO CLGARAGE GFI (ABOVE GARAGE FLOOR)12" TO CLBASEMENT WALL OUTLETS...................48" TO CLFRONT DOOR COACH LIGHT..................72" TO CLGARAGE DOOR COACH LIGHT(ABOVE GARAGE FLOOR).......................84" TO CLDINING AND BREAKFAST FIXTURE........64" TO BOTTOMOF FIXTUREFOYER AND STAIRWAY FIXTURE.......... 96" TO BOTTOMOF FIXTURETHERMOSTAT...........................................54" TO CLDOORBELL CHIMES.................................84" TO CLDOORBELL BUTTON................................LEVEL W/DOOR HANDLEKITCHEN HOOD FAN "WHIP"...................66" TO CLKITCHEN WALL HUNGMICROWAVE OUTLET..............................76" TO CLKITCHEN DISHWASHER RECEPTACLE.UNDER SINKKITCHEN RANGE......................................24" TO CLKITCHEN REFRIGERATOR......................48" TO CLWASHER/DRYER OUTLET...................... 48" TO CLCL = CENTERLINE1 = FIELD VERIFY2 = MASTER BATH STANDARD 30" HIGHVANITY TO BE RAISED 4"1,2TO FIXTURE ABOVESDCOGFI/WPCERAMICCERAMICCERAMICCERAMICCERAMICCERAMICJOB NO:DRAWN:PROJ MGR:CHECKED:ISSUE DATE:O'Brien Home Farm Single Family Downhill LotSouth Burlington, VT 05403E0.1B09/01/17BASEMENT ELECTRICALPLAN-BElevation - BDAISYREVISIONSSCALE:1/4" = 1'-0" (22x34)1Basement ElectricalPlan
FD3334DSDSDCOGFITO SWITCH ABOVEFLUSHTVFLUSHFLUSHFLUSHCERAMICCERAMIC6" LED SURFACE6" LED SURFACE2-LIGHT VANITYCERAMICCERAMICCERAMICELECTRICAL KEY:SINGLE POLE DUPLEX CONVENIENCE OUTLETDUPLEX OUTLET ABOVE COUNTERWEATHERPROOF DUPLEX OUTLETWPGFIGROUND-FAULT CIRCUIT-INTERRUPTER DUPLEX OUTLETHALF-SWITCHED DUPLEX OUTLETSPECIAL POURPOSE OUTLET/JUNCTION BOXUSB CHARGER/TAMPER-RESISTANT DUPLEX OUTLETUSBDUPLEX OUTLET IN FLOOR220 VOLT OUTLET220VOVERHEAD DUPLEXWALL SWITCHTHREE-WAY SWITCHFOUR-WAY SWITCHDIMMER SWITCHREINFORCED JUNCTION BOXCEILING MOUNTED LIGHT FIXTUREWALL MOUNTED LIGHT FIXTURERECESSED LIGHT FIXTURERECESSED LIGHT FIXTURE (WEATHERPROOF)WPRECESSED FLOURESCENT LIGHT FIXTURE (WEATHERPROOF)FLURECESSED LIGHT FIXTURE (VAPOR-PROOF)VPRECESSED FLOURESCENT LIGHT FIXTURE (VAPOR-PROOF)VP/FLUPNDTCEILING MOUNTED PENDANT LIGHT FIXTUREMINICEILING MOUNTED MINI-PENDANT LIGHT FIXTURELEDCEILING MOUNTED LED LIGHT FIXTUREWALL MOUNTED LED LIGHT FIXTURELEDRECESSED LED LIGHT FIXTURELEDRECESSED ADJUSTABLE EYEBALL LED LIGHT FIXTUREEBPCLED LIGHT FIXTURE WITH PULL CHAINFLUORESCENT LIGHT FIXTUREFLUORESCENT LIGHT FIXTURE WITH PULL CHAINPCEXHAUST FAN (VENT TO EXIT)EXHAUST FAN/LIGHT COMBINATION (VENT TO EXIT)EXHAUST FAN WITH HEAT LAMP (VENT TO EXIT)CHIMESPUSH BUTTON SWITCHSDHDSMOKE DETECTORCOCO DETECTORHEAT DETECTORTHERMOSTATTSSPEAKER (PROVIDE ADEQUATE SUPPORT)TVTELEVISIONMELECTRIC METERELECTRIC PANELTELEPHONECOMPUTERCEILING FAN WITH LED LIGHT FIXTURE (PROVIDE ADEQUATE SUPPORT)ELECTRICAL NOTES:* PROVIDE AND INSTALL LOCALLY CERTIFIED SMOKE DETECTORS AS REQUIRED BY NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) AND MEETING THE REQUIREMENTS OF ALL GOVERNING CODES* PROVIDE AND INSTALL GROUND FAULT CIRCUIT-INTERRUPTERS (GFI) AS REQUIRED BY NATIONAL ELECTRIC CODE (NEC) AND MEETING THE REQUIREMENTS OF ALL GOVERNING CODES.* ELECTRICAL CONTRACTOR TO PROVIDE REQUIRED DIRECT HOOK-UPS/CUTOFFS.* HVAC CONTRACTOR TO VERIFY THERMOSTAT LOCATIONS.* ALL ELECTRICAL AND MECHANICAL EQUIPMENT (I.E. FURNACES, A/C UNITS, ELECTRICAL PANELS, SANITARY SUMP PITS, DRAIN TILE SUMP, AND WATER HEATERS) ARE SUBJECT TO RELOCATION DUE TO FIELD CONDITIONS.* ALL BRANCH CIRCUITS THAT SUPPLY 125 VOLT 15 & 20 AMP RECEPTACLE OUTLETS INSTALLED IN ANY HABITAL SPACE SHALL BE PROTECTED BY AN ARC FAULT CIRCUIT INTERRUPTER PER N.E.C. 210-12(A) & (B).ELECTRICAL DEVICES:ABOVE FINISHED FLOOR:SWITCHES OVER COUNTER.................. 48" TO CLWALL OUTLETS OVER COUNTER..........48" TO CLREMAINING SWITCHES...........................48" TO CLWALL OUTLETS........................................ 12" TO CLBATH VANITY BRACKET OUT(1" ABOVE TOP OF MIRROR)............80" TO CLWATER SOFTENER AND SUMP OUTLETS........................................48" TO CLTELEPHONE OUTLETS............................12" TO CLTELEVISION OUTLETS.............................12" TO CLEXTERIOR GFI OUTLETS.........................12" TO CLGARAGE GFI (ABOVE GARAGE FLOOR)12" TO CLBASEMENT WALL OUTLETS...................48" TO CLFRONT DOOR COACH LIGHT..................72" TO CLGARAGE DOOR COACH LIGHT(ABOVE GARAGE FLOOR).......................84" TO CLDINING AND BREAKFAST FIXTURE........64" TO BOTTOMOF FIXTUREFOYER AND STAIRWAY FIXTURE.......... 96" TO BOTTOMOF FIXTURETHERMOSTAT...........................................54" TO CLDOORBELL CHIMES.................................84" TO CLDOORBELL BUTTON................................LEVEL W/DOOR HANDLEKITCHEN HOOD FAN "WHIP"...................66" TO CLKITCHEN WALL HUNGMICROWAVE OUTLET..............................76" TO CLKITCHEN DISHWASHER RECEPTACLE.UNDER SINKKITCHEN RANGE......................................24" TO CLKITCHEN REFRIGERATOR......................48" TO CLWASHER/DRYER OUTLET...................... 48" TO CLCL = CENTERLINE1 = FIELD VERIFY2 = MASTER BATH STANDARD 30" HIGHVANITY TO BE RAISED 4"1,2JOB NO:DRAWN:PROJ MGR:CHECKED:ISSUE DATE:O'Brien Home Farm Single Family Downhill LotSouth Burlington, VT 05403E4.1.109/01/17OPT FINISHED BASEMENTELECTRICAL PLANOptional Finished BasementSCALE:1/4" = 1'-0" (22x34)Finished Basement Electrical PlanDAISYREVISIONS
DW343333333343434DWP/ GFISDGFI220VGFITO SWITCHBELOWMICROGFIGFIGFIGFIGFIGFIGFISDSDCOSDCOWP/ GFIWP/ GFIGFIGFI GFIWP/ GFITVTVSDGFI220VGFITO SWITCHBELOW6" LED SURFACE LIGHT MICROGFIGFIGFIGFICHANDELIERGFIGFISDSDCOSDCOWP/ GFIWP/ GFISEMI-FLUSHGFIGFI GFIWP/ GFITVTVGFITV6" LED SURFACE LIGHT 6" LED SURFACE LIGHT 6" LED SURFACE LIGHT 6" LED SURFACE LIGHT 6" LED SURFACE LIGHT GFIFLUSHFLUSHFLUSHFLUSHFLUSHFLUSHFLUSHCERAMICCERAMICCERAMICCERAMIC6" LED SURFACE LIGHT 6" LED SURFACE LIGHT 6" LED SURFACE LIGHT 6" LED SURFACE LIGHT PHOTOCELL6" LED SURFACE LIGHT FLUSH6" LED SURFACE LIGHT ELECTRICAL KEY:SINGLE POLE DUPLEX CONVENIENCE OUTLETDUPLEX OUTLET ABOVE COUNTERWEATHERPROOF DUPLEX OUTLETWPGFIGROUND-FAULT CIRCUIT-INTERRUPTER DUPLEX OUTLETHALF-SWITCHED DUPLEX OUTLETSPECIAL POURPOSE OUTLET/JUNCTION BOXUSB CHARGER/TAMPER-RESISTANT DUPLEX OUTLETUSBDUPLEX OUTLET IN FLOOR220 VOLT OUTLET220VOVERHEAD DUPLEXWALL SWITCHTHREE-WAY SWITCHFOUR-WAY SWITCHDIMMER SWITCHREINFORCED JUNCTION BOXCEILING MOUNTED LIGHT FIXTUREWALL MOUNTED LIGHT FIXTURERECESSED LIGHT FIXTURERECESSED LIGHT FIXTURE (WEATHERPROOF)WPRECESSED FLOURESCENT LIGHT FIXTURE (WEATHERPROOF)FLURECESSED LIGHT FIXTURE (VAPOR-PROOF)VPRECESSED FLOURESCENT LIGHT FIXTURE (VAPOR-PROOF)VP/FLUPNDTCEILING MOUNTED PENDANT LIGHT FIXTUREMINICEILING MOUNTED MINI-PENDANT LIGHT FIXTURELEDCEILING MOUNTED LED LIGHT FIXTUREWALL MOUNTED LED LIGHT FIXTURELEDRECESSED LED LIGHT FIXTURELEDRECESSED ADJUSTABLE EYEBALL LED LIGHT FIXTUREEBPCLED LIGHT FIXTURE WITH PULL CHAINFLUORESCENT LIGHT FIXTUREFLUORESCENT LIGHT FIXTURE WITH PULL CHAINPCEXHAUST FAN (VENT TO EXIT)EXHAUST FAN/LIGHT COMBINATION (VENT TO EXIT)EXHAUST FAN WITH HEAT LAMP (VENT TO EXIT)CHIMESPUSH BUTTON SWITCHSDHDSMOKE DETECTORCOCO DETECTORHEAT DETECTORTHERMOSTATTSSPEAKER (PROVIDE ADEQUATE SUPPORT)TVTELEVISIONMELECTRIC METERELECTRIC PANELTELEPHONECOMPUTERCEILING FAN WITH LED LIGHT FIXTURE (PROVIDE ADEQUATE SUPPORT)ELECTRICAL NOTES:* PROVIDE AND INSTALL LOCALLY CERTIFIED SMOKE DETECTORS AS REQUIRED BY NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) AND MEETING THE REQUIREMENTS OF ALL GOVERNING CODES* PROVIDE AND INSTALL GROUND FAULT CIRCUIT-INTERRUPTERS (GFI) AS REQUIRED BY NATIONAL ELECTRIC CODE (NEC) AND MEETING THE REQUIREMENTS OF ALL GOVERNING CODES.* ELECTRICAL CONTRACTOR TO PROVIDE REQUIRED DIRECT HOOK-UPS/CUTOFFS.* HVAC CONTRACTOR TO VERIFY THERMOSTAT LOCATIONS.* ALL ELECTRICAL AND MECHANICAL EQUIPMENT (I.E. FURNACES, A/C UNITS, ELECTRICAL PANELS, SANITARY SUMP PITS, DRAIN TILE SUMP, AND WATER HEATERS) ARE SUBJECT TO RELOCATION DUE TO FIELD CONDITIONS.* ALL BRANCH CIRCUITS THAT SUPPLY 125 VOLT 15 & 20 AMP RECEPTACLE OUTLETS INSTALLED IN ANY HABITAL SPACE SHALL BE PROTECTED BY AN ARC FAULT CIRCUIT INTERRUPTER PER N.E.C. 210-12(A) & (B).ELECTRICAL DEVICES:ABOVE FINISHED FLOOR:SWITCHES OVER COUNTER.................. 48" TO CLWALL OUTLETS OVER COUNTER..........48" TO CLREMAINING SWITCHES...........................48" TO CLWALL OUTLETS........................................ 12" TO CLBATH VANITY BRACKET OUT(1" ABOVE TOP OF MIRROR)............80" TO CLWATER SOFTENER AND SUMP OUTLETS........................................48" TO CLTELEPHONE OUTLETS............................12" TO CLTELEVISION OUTLETS.............................12" TO CLEXTERIOR GFI OUTLETS.........................12" TO CLGARAGE GFI (ABOVE GARAGE FLOOR)12" TO CLBASEMENT WALL OUTLETS...................48" TO CLFRONT DOOR COACH LIGHT..................72" TO CLGARAGE DOOR COACH LIGHT(ABOVE GARAGE FLOOR).......................84" TO CLDINING AND BREAKFAST FIXTURE........64" TO BOTTOMOF FIXTUREFOYER AND STAIRWAY FIXTURE.......... 96" TO BOTTOMOF FIXTURETHERMOSTAT...........................................54" TO CLDOORBELL CHIMES.................................84" TO CLDOORBELL BUTTON................................LEVEL W/DOOR HANDLEKITCHEN HOOD FAN "WHIP"...................66" TO CLKITCHEN WALL HUNGMICROWAVE OUTLET..............................76" TO CLKITCHEN DISHWASHER RECEPTACLE.UNDER SINKKITCHEN RANGE......................................24" TO CLKITCHEN REFRIGERATOR......................48" TO CLWASHER/DRYER OUTLET...................... 48" TO CLCL = CENTERLINE1 = FIELD VERIFY2 = MASTER BATH STANDARD 30" HIGHVANITY TO BE RAISED 4"1,2JOB NO:DRAWN:PROJ MGR:CHECKED:ISSUE DATE:O'Brien Home Farm Single Family Downhill LotSouth Burlington, VT 05403E1.1B09/01/17MAIN FLOOR ELECTRICALPLAN-BElevation - BSCALE:1/4" = 1'-0" (22x34)Main Floor Electrical PlanDAISYREVISIONS