HomeMy WebLinkAboutSD-21-19 - Supplemental - 0600 Spear Street (10)478 Blair Park Road Williston, VT 05495 802 879 6331www.tcevt.com42 Mapleville Depot Road St. Albans, VT 05478 802 528 5116
Civil Engineering Environmental Services Land Surveying Landscape Architecture
Page 1 of 1
May 14, 2021
Paul Conner, AICP
Director of Planning and Zoning
575 Dorset Street
South Burlington, VT 05403
RE: Wastewater Allocation Request – 600 Spear Street
Dear Paul:
This letter accompanies a wastewater allocation request submitted by Eastern
Development Corporation for a new connection to the municipality for a project
located at 600 Spear Street to accommodate a propose residential planned unit
development. The property is currently developed with a residential duplex serviced by
municipal water and on-site wastewater. The existing residential duplex consists of a 1-
bedroom and 5-bedroom unit which will remain. There is an 8,000 sf commercial
building on the property is connected to the existing on-site wastewater system and the
municipal water system. This project proposes a total of 32 new residential 1-bedroom
units and a 5,000 sf commercial space with 10 employees.The remaining 3,000 sf
commercial space will be for use by the tenants off the residential complex. The project
will consist of a total of 34 residential units ((33) 1-bedroom and (1) 5-bedroom). This
allocation request includes a new connection to the municipality for the existing
residential duplex and the commercial space.The total daily flow requested is 4,980
GPD. Should you need additional information, please let me know.
Very truly yours,
TRUDELL CONSULTING ENGINEERS (TCE)
Amanda Raab
Engineer II
cc. 600 Spear FJT, LLC
600 Spear EBT, LLC
Encl. Application for Wastewater Allocation
C3-01 Utility Plan Overview
CITY OF SOUTH BURLINGTON
APPLICATION for WASTEWATER ALLOCATION
*Items marked with an asterisk must be filled in by ALL applicants
*APPLICANT INFORMATION
Applicant: ______________________________________________
Contact Person: ________________________________________________
Mailing Address: _______________________________________________
_______________________________________________
Telephone & Fax for Contact Person: __________________________________
Property Owner Name (if not applicant): _______________________________
Property Owner Mailing Address: ____________________________________
____________________________________
*Physical Location of Project: ________________________________
__________________ ______________________
*Signature of Applicant *Signature of Property Owner
(Both applicant and property owner MUST sign the application!)
*Project Information
If the project is a single-family home, please check one: ____New ____Existing
If not a single-family home, project name: __________________________
*Application or Permit Numbers: (from Planning & Zoning office)
#____-____-____
#____-____-____
#____-____-____
Engineer’s Information for flows over 1,000 gpd
Name of Engineer: ____________________________________________
Firm: _____________________________________________________
Mailing Address: _____________________________________________
Phone & Fax: ________________________________________________
PE License #: ________________________________________________
FOR INTERNAL USE ONLY
WWA Permit #___-____
Eastern Development Corporation
Frank VonTurkovich
1 National Life Drive - M230
Montpelier, VT 05604
802-299-3431
Eastern Development Corporation
1 National Life Drive - M230
Montpelier, VT 05604
600 Spear Street
600 Spear Street
Abby Dery
Trudell Consulting Engineers
478 Blair Park Road, Williston, VT 05495
802-879-6331
9020
DocuSign Envelope ID: 1C63D2BA-2E69-40C2-80ED-998ED7133163
*Flow Calculations
(You may substitute an engineer’s calculation or letter for the information requested
below)
For residential projects, list number of bedrooms and units requested:
Number of
Bedrooms
Number of Units
X
Gallons per day
per unit =
Total Flows
1 140
2 or more 210
TOTAL
Notes: ___________________________________________________
________________________________________________________
For commercial and industrial projects, list existing and proposed tenants, uses and
flows:
Tenant/ Type of use Number of Flows per Other Total
Business seats, SF, etc X unit Adjustments Flow
TOTAL
*Total development wastewater flow requested: ________gallons per
day
Flow characteristics (for commercial and industrial projects)
Volume:
____________________________________________________________
__________________________________________________
Flow rate:
____________________________________________________________
__________________________________________________
Strength:
____________________________________________________________
__________________________________________________
see attached spreadsheet
see attached spreadsheet
4,980
4,980 gpd
pumped from pump station to municipal gravity sewer. projected pump flow rate
100 gpm (run time of 28 mins per day split between 4-5 doses / day)
domestic strength wastewater standard parameters no usual characteristics projected
DocuSign Envelope ID: 1C63D2BA-2E69-40C2-80ED-998ED7133163
Please do not write below this line
Application & Recording Fee received: _____________ ________
Name Date
Receiving Plant: ______Airport Pkwy _____Bartlett Bay
City Center District: ____Yes _____No
Approved by Water Pollution Control Department (Commercial and Industrial
Projects)
______________________ _____________
Director of Water Pollution Control Date
Preliminary allocation issued: (payment of fee is not required)
_______________________ _____________
Director of Planning and Zoning Date
Final allocation issued: (payment of fee is required, either in full or pro-rated for
projects with multiple zoning permits involved)
_______________________ _____________
Director of Planning and Zoning Date
Final allocation expires _________________with permit #____-____-____
(Date)
Zoning permit issued___________________with permit#____-____-____
(Date)
Associated WW connection permit (if applicable) #____-____-____
For extensions of Final Allocation Only
EXTENSION GRANTED ____________to______________
(Date) (Date of Expiration)
50% EXTENSION FEE PAID _________ $___________
(Date) (Amount)
DocuSign Envelope ID: 1C63D2BA-2E69-40C2-80ED-998ED7133163
600 Spear Street, South Burlington, VT
Eastern Development Corporation
Water and Wastewater Design Flows
January 18, 2021
Existing
Source Units Quantity Flow Per Unit (GPD)Design Flow (GPD) Notes
Existing Home Bedrooms 5 150 750
Existing Home Apt.Bedrooms 1 150 150
Commercial Buildling 7,000 sf water/sewer utilties exist, design flow unknown
Total Flow (GPD)900 On-Site Wastewater
Proposed
Source Units Quantity Flow Per Unit (GPD)Design Flow (GPD) Notes
1-Bed Residential Units Per Unit 33 140 4,620 4-plexes and 1-bed in existing home
Existing Residentail Unit Per Unit 1 210 210 5-bed in existing home
Commercial Buildling 5,000 sf Employees 10 15 150 general warehouse
Commercial Building 2,000 sf N/A 0 0 0 for use by residentail tenants (no outside users)
Total Flow (GPD)4,980 Municipal Wastewater
Net Increase - Allocation Request
Existing Flow 0 No Existing Municipal Flow
Proposed Flow 4,980 Project Total
Net Increase 4,980 GPD Increase
Existing
Source Units Quantity Flow Per Unit (GPD)Design Flow (GPD) Notes
Existing Home Bedrooms 5 150 750
Existing Home Apt.Bedrooms 1 150 150
Commercial Buildling 7,000 sf water/sewer utilties exist, design flow unknown
Total Flow (GPD)900 Municipal Water
Proposed
Source Units Quantity Flow Per Unit (GPD)Design Flow (GPD) Notes
1-Bed Residential Units Per Unit 33 140 4,620 4-plexes and 1-bed in existing home
Existing Residentail Unit Per Unit 1 210 210 5-bed in existing home
Commercial Buildling 5,000 sf Employees 10 15 150 general warehouse
Commercial Building 2,000 sf N/A 0 0 0 for use by residentail tenants (no outside users)
Total Flow (GPD)4,980
Net Increase - Allocation Request
Existing Flow 900 Existing Municpal Flow
Proposed Flow 4,980 Project Total
Net Increase 4,080 GPD Increase
Wastewater
Water
M
M
M OHOHG G
UG UG
UGOHOHOH
OHOHOHWWWWWWWWWW W
W
W
2"
UT UT
UT
401/36
37
38
WATER MANHOLE
RIM = 298.8
BLOWOFF VALVE
ASSUMED LOCATION OF
EXISTING WATER MAIN
i = 293.59
12" CMP
i = 293.58
291
297
290
289288
288
289
290
291
28
7292293294
295296297298299300301297298299300301289290291
292
293
295
294 298295296297294293292291290
298
291
292
29
3
2
9
4
2
9
5296 291 292
2
9
3
294
29629529429929829
7
29
6
2
9
6
29
7
29
8
299
299295
296
297
298
299299
298
299
298
297
296
295
294
295298 298
300 299 298 297 296
295294 296295
294293292
28
8
2
8
9288
2892902912872892
9
0 291292293294
294
292
293
294
295
29
8
29629
5
298
297
299
2
9
9
299
301300
301298297296295
WWWWW W W W W
WWWWWWWWWWWWWWWWWWD D D D DDD
D DDDDDDDDDD DW
DDWDDDD D D D D
D
SSSSS
S S S S S S
SSSFMFM FM FM FM FM FM FM FM FM FM FM FM FM
FM
S S SS S
SSPROPOSED MAINTENANCE EASEMENT
4" SDR 21 FORCE MAIN
PUMP STATION
VALVE PIT
RBUILDING 1
BUILDING 4
BUILDING 6
BUILDING 2 BUILDING 7
BUILDING 3
BUILDING 5
BUILDING 8
296
296 296 296296
298
298
2
9
8
298
298298298
299 299299299 299
299299
299
299
298 298 298 298 298
298
297 297 297 297296296296299299299
299
299 299 299299299 299299
299
299 299
299296297300
300300
300
300
298 298 295297297 296296297298298298291292293295295295295294294294294
293293293292292
297
297
297
297
297297
30030
0
300300300300
3013013013
0
1
298299297 298
295
295
294
300 30
0
299
299
29
8
29
8
2
9
9
29
8 299STORMWATER DIVERSION SETTLING POND
STORMWATER DIVERSION STORM MANHOLE
18" STORMWATER DIVERSION PIPE
FIRE HYDRANT, TYP.
BIORETENTION POND, TYP.
PEASTONE FILTER
STRIP, TYP.
STORM DRAINAGE MANHOLE, TYP.
FILTERA STORMWATER
TREATMENT UNIT, TYP.
BEEHIVE GRATE
OVERFLOW
WATER QUALITY BASIN INLET, TYP.
CATCH BASIN - ALL OTHER
GRATES SHOWN ARE
WATER QUALITY INLETS
SEWER MANHOLE, TYP.
UNDERGROUND
STORMWATER
MANAGEMENT
SYSTEM
TREATED
STORMWATER
DISCHARGE PIPE
STORMWATER DIVERSION
DISCHARGE PIPE
WATER SERVICE WITH CURB STOP, TYP.
SEWER SERVICE FOR
EXISTING RESIDENCE
SEWER SERVICE, TYP.
FORCEMAIN SENDING/
RECEIVING PIT - DIRECTIONAL
DRILL UNDER WETLAND
SLEEVE PIPE, TYP.
SLEEVE PIPE, TYP.
M
M
MOH UGOHOH
OHWWWWW ØØØØØØØØØØØØ2"
UT SSSSINTERSTATE 89 S401/36
37
38 INTERSTATE 89 N ASSUMED
LOCATION
EXISTING SEPTIC
AREA
ASSUMED
LOCATION OF
WATER SERVICE
EXISTING WATER SERVICE
EXISTING SEPTIC TANK
REFERENCE EC-4-0700
ASSUMED
LOCATION OF
WATER SERVICE
WATER
MANHOLE
RIM = 298.8
BLOWOFF VALVE
ASSUMED
LOCATION OF
EXISTING
WATER MAIN
EXISTING SMH ROUND
RIM = ±303.0
iIN/OUT = ±291.5
EXISTING SMH SQUARE
RIM = ±303.2
iIN/OUT = ±293.228828929
0 291292293294292293295296 297294294 2912922932
8
8289290291292293 293
293
29730030230329829930230230130130430130230330330329829930030429729
8
2
9
9
300 2972982993003003043053023013063013023033033053043003023
0
1 30430
5
306
303300302301304305306
303303304
300
302
301
303
299
304305306301302303305304295296297298299 30
0
295296
297298299
2
9
8
29
9
30
0
298
299
300
295296294297295296294300299298297291292293294295296297290300298299WWW W
WWWWWWWWWD DD DDDD D
SS S S
SFM FM FM FM FM FM
FM
FM
FM FM FM
S S4" SDR 21 FORCE MAIN
DIRECTIONAL DRILL SENDING PIT, OPEN
EXCAVATION FROM THE PUMP STATION
TO THIS POINT. DIRECTIONAL DRILL UNDER
INTERSTATE 89 TO THE LOCATION SHOWN
ON THE PLANS NAMED RECEIVING PIT.
DIRECTIONAL DRILL RECEIVING
PIT. FROM THIS POINT TO TO
THE PROPOSED MANHOLE,
OPEN TRENCH CUT.
PROPOSED SEWER MANHOLE
RIM = ±302.25
iIN = ±290.5
iOUT = ±290.4
12" PIPE
PUMP
STATION
VALVE PIT
STORMWATER DIVERSION SETTLING POND
STORMWATER DIVERSION STORM MANHOLE
18" STORMWATER DIVERSION PIPE
FIRE HYDRANT, TYP.
BIORETENTION POND, TYP.
PEASTONE FILTER
STRIP, TYP.
STORM DRAINAGE MANHOLE, TYP.
FILTERA STORMWATER
TREATMENT UNIT, TYP.
BEEHIVE GRATE
OVERFLOW
WATER QUALITY BASIN INLET, TYP.
CATCH BASIN - ALL OTHER
GRATES SHOWN ARE
WATER QUALITY INLETS
SEWER MANHOLE, TYP.
UNDERGROUND
STORMWATER
MANAGEMENT
SYSTEM
TREATED
STORMWATER
DISCHARGE PIPE
STORMWATER DIVERSION
DISCHARGE PIPE
WATER SERVICE WITH CURB STOP, TYP.
SEWER SERVICE FOR
EXISTING RESIDENCE
SEWER SERVICE, TYP.
FORCEMAIN SENDING/
RECEIVING PIT - DIRECTIONAL
DRILL UNDER WETLAND
SLEEVE PIPE, TYP.
SLEEVE PIPE, TYP.
Sheet Title
Project Title
Use of These Drawings
Scale:
Project Number:
Date:
Drawn By:
Project Engineer:
Approved By:
No. Description Date By
Revisions
478 BLAIR PARK ROAD | WILLISTON, VERMONT 05495
802 879 6331 | WWW.TCEVT.COM
ENGINEERING SURVEY
No. 9020
CIVILABIGAIL A.
D
E
RYSTATE O F VER
M
O
NT
PROF
E
SSIONAL
E N G INEERLICE N S E D
Field Book:
For Local Permitting Only
1. Unless otherwise noted, these Drawings are intended for
preliminary planning, coordination with other disciplines or
utilities, and/or approval from the regulatory authorities.
They are not intended as construction drawings unless noted
as such or marked approved by a regulatory authority.
2. By use of these drawings for construction of the Project,
the Owner represents that they have reviewed, approved,
and accepted the drawings, obtained all necessary permits,
and have met with all applicable parties/disciplines,
including but not limited to, the Engineer and the Architect,
to insure these plans are properly coordinated including, but
not limited to, contract documents, specifications,
owner/contractor agreements, building and mechanical
plans, private and public utilities, and other pertinent permits
for construction.
3. Owner and Architect, are responsible for final design and
location of buildings shown, including an area measured a
minimum five (5) feet around any building and coordinating
final utility connections shown on these plans.
4. Prior to using these plans for construction layout, the user
shall contact TCE to ensure the plan contains the most
current revisions.
5. These Drawings are specific to the Project and are not
transferable. As instruments of service, these drawings, and
copies thereof, furnished by TCE are its exclusive property.
Changes to the drawings may only be made by TCE. If
errors or omissions are discovered, they shall be brought to
the attention of TCE immediately.
6. It is the User's responsibility to ensure this copy contains
the most current revisions.
PLANNING ENVIRONMENTAL
SPAN: 600-188-11469 PARCEL:
1640-00600
Utility Plan
Overview
C3-01
5/14/2021
As Shown
19-268
ALR
AAD
600 Spear FJT, LLC
600 Spear Street
So. Burlington, Vermont
SEWER CONNECTION PLAN
1" = 80'-0"A
B UTILITY PLAN
1" = 40'-0"
478 Blair Park Road Williston, VT 05495 802 879 6331www.tcevt.com42 Mapleville Depot Road St. Albans, VT 05478 802 528 5116
Civil Engineering Environmental Services Land Surveying Landscape Architecture
Page 1 of 1
May 14, 2021
John Tymecki
South Burlington Water Department
403 Queen City Park Road
South Burlington, VT 05403
RE: Water Allocation Request – 600 Spear Street
Dear John:
This letter accompanies a water allocation request submitted by Eastern Development
Corporation for a new connection to the municipality for a project located at 600
Spear Street to accommodate a propose residential planned unit development. The
property is currently developed with a residential duplex serviced by municipal water
and on-site wastewater. The existing residential duplex consists of a 1-bedroom and 5-
bedroom unit which will remain. There is a 8,000 sf commercial building on the property
is connected to the existing on-site wastewater system and the municipal water system.
This project proposes a total of 32 new residential 1-bedroom units and a 5,000 sf
commercial space with 10 employees.The remaining 3,000 sf commercial space will be
for use by the tenants off the residential complex. The project will consist of a total of 34
residential units ((33) 1-bedroom and (1) 5-bedroom). The existing municipal water
connection to the duplex will remain unchanged. A new municipal connection to the
commercial space is proposed from the new water main.The total daily flow requested
is 4,080 GPD. Should you need additional information, please let me know.
Very truly yours,
TRUDELL CONSULTING ENGINEERS (TCE)
Amanda Raab
Engineer II
cc. 600 Spear FJT, LLC
600 Spear EBT, LLC
Encl. Application for Wastewater Allocation
C3-01 Utility Plan Overview
APPLICATION FOR WATER ALLOCATION
Page 1
* Items marked with an asterisk must be filled in by ALL applicants
* Applicant Information
Applicant:
Contact Person:
Mailing Address:
Telephone & Fax for Contact:
Property Owner Name (if not applicant):
Property Owner Mailing Address:
* Physical location of project: ________________________________________________
______________________________
* Signature of Applicant
* Project Information
If the project is a single-family home, please check one: ____ New ____ Existing
(For existing homes, no Application is required if revised demand is less than 1,000 gpd.)
If not single-family home, project name: ___________________________________
* Application or Permit Numbers: (from Department of Planning & Zoning)
# ____-____-____
# ____-____-____
# ____-____-____
Engineer’s Information for flows over 1,000 gpd
Name of Engineer:________________________
Firm: ________________________
Mailing Address: ________________________
Phone & Fax: ________________________
PE License #: ________________________
* Flow Calculations
(You may substitute an engineer’s calculation or letter containing the information requested
below)
For additional bedrooms in single-family homes:
Number of existing bedrooms: _____
Number of additional bedrooms requested: _____
see attached spreadsheet
9020
807-879-6331
478 Blair Park Road, Williston, VT 05495
Trudell Consulting Engineers
Abby Dery
600 Spear Street
600 Spear Street
Same as
Same as
802-299-3431
1 National Life Drive - M230, Montpelier, VT 05604
Frank VonTurcovich
Eastern Development Corporation
DocuSign Envelope ID: 1C63D2BA-2E69-40C2-80ED-998ED7133163
APPLICATION FOR WATER ALLOCATION
Page 2
For other residential projects, list number of bedrooms and units requested:
Number of
bedrooms x Number of units x Gallons per day
per unit = Total flows
1 150
2 300
3 450
4 600
5 750
6+ (specify)
TOTAL
For commercial and industrial projects, list existing and proposed tenants, uses and flows:
Tenant /
Business
Type of use
Number of
seats, SF, etc.
x
Flow per unit
Other
Adjustments
Total flow
TOTAL
* Total development water flow requested: _____________ gallons per day
Please do not write below this line
Approved by Water Department
_______________________________ _________________________
Superintendent of Water Date
Preliminary Allocation approved: _______________________
Date
Final Allocation approved: _______________________
Date
Final Allocation Expires: ________________ with permit #____-____-____
(Date)
For Extensions of Final Allocation Only
EXTENSION GRANTED _____________________ to ____________________
(Date) (Date of Expiration)
G:Word:SBForms:WaterallocationForm
4080
see attached spreadsheet
see attached spreadsheet
DocuSign Envelope ID: 1C63D2BA-2E69-40C2-80ED-998ED7133163
600 Spear Street, South Burlington, VT
Eastern Development Corporation
Water and Wastewater Design Flows
January 18, 2021
Existing
Source Units Quantity Flow Per Unit (GPD)Design Flow (GPD) Notes
Existing Home Bedrooms 5 150 750
Existing Home Apt.Bedrooms 1 150 150
Commercial Buildling 7,000 sf water/sewer utilties exist, design flow unknown
Total Flow (GPD)900 On-Site Wastewater
Proposed
Source Units Quantity Flow Per Unit (GPD)Design Flow (GPD) Notes
1-Bed Residential Units Per Unit 33 140 4,620 4-plexes and 1-bed in existing home
Existing Residentail Unit Per Unit 1 210 210 5-bed in existing home
Commercial Buildling 5,000 sf Employees 10 15 150 general warehouse
Commercial Building 2,000 sf N/A 0 0 0 for use by residentail tenants (no outside users)
Total Flow (GPD)4,980 Municipal Wastewater
Net Increase - Allocation Request
Existing Flow 0 No Existing Municipal Flow
Proposed Flow 4,980 Project Total
Net Increase 4,980 GPD Increase
Existing
Source Units Quantity Flow Per Unit (GPD)Design Flow (GPD) Notes
Existing Home Bedrooms 5 150 750
Existing Home Apt.Bedrooms 1 150 150
Commercial Buildling 7,000 sf water/sewer utilties exist, design flow unknown
Total Flow (GPD)900 Municipal Water
Proposed
Source Units Quantity Flow Per Unit (GPD)Design Flow (GPD) Notes
1-Bed Residential Units Per Unit 33 140 4,620 4-plexes and 1-bed in existing home
Existing Residentail Unit Per Unit 1 210 210 5-bed in existing home
Commercial Buildling 5,000 sf Employees 10 15 150 general warehouse
Commercial Building 2,000 sf N/A 0 0 0 for use by residentail tenants (no outside users)
Total Flow (GPD)4,980
Net Increase - Allocation Request
Existing Flow 900 Existing Municpal Flow
Proposed Flow 4,980 Project Total
Net Increase 4,080 GPD Increase
Wastewater
Water
M
M
M OHOHG G
UG UG
UGOHOHOH
OHOHOHWWWWWWWWWW W
W
W
2"
UT UT
UT
401/36
37
38
WATER MANHOLE
RIM = 298.8
BLOWOFF VALVE
ASSUMED LOCATION OF
EXISTING WATER MAIN
i = 293.59
12" CMP
i = 293.58
291
297
290
289288
288
289
290
291
28
7292293294
295296297298299300301297298299300301289290291
292
293
295
294 298295296297294293292291290
298
291
292
29
3
2
9
4
2
9
5296 291 292
2
9
3
294
29629529429929829
7
29
6
2
9
6
29
7
29
8
299
299295
296
297
298
299299
298
299
298
297
296
295
294
295298 298
300 299 298 297 296
295294 296295
294293292
28
8
2
8
9288
2892902912872892
9
0 291292293294
294
292
293
294
295
29
8
29629
5
298
297
299
2
9
9
299
301300
301298297296295
WWWWW W W W W
WWWWWWWWWWWWWWWWWWD D D D DDD
D DDDDDDDDDD DW
DDWDDDD D D D D
D
SSSSS
S S S S S S
SSSFMFM FM FM FM FM FM FM FM FM FM FM FM FM
FM
S S SS S
SSPROPOSED MAINTENANCE EASEMENT
4" SDR 21 FORCE MAIN
PUMP STATION
VALVE PIT
RBUILDING 1
BUILDING 4
BUILDING 6
BUILDING 2 BUILDING 7
BUILDING 3
BUILDING 5
BUILDING 8
296
296 296 296296
298
298
2
9
8
298
298298298
299 299299299 299
299299
299
299
298 298 298 298 298
298
297 297 297 297296296296299299299
299
299 299 299299299 299299
299
299 299
299296297300
300300
300
300
298 298 295297297 296296297298298298291292293295295295295294294294294
293293293292292
297
297
297
297
297297
30030
0
300300300300
3013013013
0
1
298299297 298
295
295
294
300 30
0
299
299
29
8
29
8
2
9
9
29
8 299STORMWATER DIVERSION SETTLING POND
STORMWATER DIVERSION STORM MANHOLE
18" STORMWATER DIVERSION PIPE
FIRE HYDRANT, TYP.
BIORETENTION POND, TYP.
PEASTONE FILTER
STRIP, TYP.
STORM DRAINAGE MANHOLE, TYP.
FILTERA STORMWATER
TREATMENT UNIT, TYP.
BEEHIVE GRATE
OVERFLOW
WATER QUALITY BASIN INLET, TYP.
CATCH BASIN - ALL OTHER
GRATES SHOWN ARE
WATER QUALITY INLETS
SEWER MANHOLE, TYP.
UNDERGROUND
STORMWATER
MANAGEMENT
SYSTEM
TREATED
STORMWATER
DISCHARGE PIPE
STORMWATER DIVERSION
DISCHARGE PIPE
WATER SERVICE WITH CURB STOP, TYP.
SEWER SERVICE FOR
EXISTING RESIDENCE
SEWER SERVICE, TYP.
FORCEMAIN SENDING/
RECEIVING PIT - DIRECTIONAL
DRILL UNDER WETLAND
SLEEVE PIPE, TYP.
SLEEVE PIPE, TYP.
M
M
MOH UGOHOH
OHWWWWW ØØØØØØØØØØØØ2"
UT SSSSINTERSTATE 89 S401/36
37
38 INTERSTATE 89 N ASSUMED
LOCATION
EXISTING SEPTIC
AREA
ASSUMED
LOCATION OF
WATER SERVICE
EXISTING WATER SERVICE
EXISTING SEPTIC TANK
REFERENCE EC-4-0700
ASSUMED
LOCATION OF
WATER SERVICE
WATER
MANHOLE
RIM = 298.8
BLOWOFF VALVE
ASSUMED
LOCATION OF
EXISTING
WATER MAIN
EXISTING SMH ROUND
RIM = ±303.0
iIN/OUT = ±291.5
EXISTING SMH SQUARE
RIM = ±303.2
iIN/OUT = ±293.228828929
0 291292293294292293295296 297294294 2912922932
8
8289290291292293 293
293
29730030230329829930230230130130430130230330330329829930030429729
8
2
9
9
300 2972982993003003043053023013063013023033033053043003023
0
1 30430
5
306
303300302301304305306
303303304
300
302
301
303
299
304305306301302303305304295296297298299 30
0
295296
297298299
2
9
8
29
9
30
0
298
299
300
295296294297295296294300299298297291292293294295296297290300298299WWW W
WWWWWWWWWD DD DDDD D
SS S S
SFM FM FM FM FM FM
FM
FM
FM FM FM
S S4" SDR 21 FORCE MAIN
DIRECTIONAL DRILL SENDING PIT, OPEN
EXCAVATION FROM THE PUMP STATION
TO THIS POINT. DIRECTIONAL DRILL UNDER
INTERSTATE 89 TO THE LOCATION SHOWN
ON THE PLANS NAMED RECEIVING PIT.
DIRECTIONAL DRILL RECEIVING
PIT. FROM THIS POINT TO TO
THE PROPOSED MANHOLE,
OPEN TRENCH CUT.
PROPOSED SEWER MANHOLE
RIM = ±302.25
iIN = ±290.5
iOUT = ±290.4
12" PIPE
PUMP
STATION
VALVE PIT
STORMWATER DIVERSION SETTLING POND
STORMWATER DIVERSION STORM MANHOLE
18" STORMWATER DIVERSION PIPE
FIRE HYDRANT, TYP.
BIORETENTION POND, TYP.
PEASTONE FILTER
STRIP, TYP.
STORM DRAINAGE MANHOLE, TYP.
FILTERA STORMWATER
TREATMENT UNIT, TYP.
BEEHIVE GRATE
OVERFLOW
WATER QUALITY BASIN INLET, TYP.
CATCH BASIN - ALL OTHER
GRATES SHOWN ARE
WATER QUALITY INLETS
SEWER MANHOLE, TYP.
UNDERGROUND
STORMWATER
MANAGEMENT
SYSTEM
TREATED
STORMWATER
DISCHARGE PIPE
STORMWATER DIVERSION
DISCHARGE PIPE
WATER SERVICE WITH CURB STOP, TYP.
SEWER SERVICE FOR
EXISTING RESIDENCE
SEWER SERVICE, TYP.
FORCEMAIN SENDING/
RECEIVING PIT - DIRECTIONAL
DRILL UNDER WETLAND
SLEEVE PIPE, TYP.
SLEEVE PIPE, TYP.
Sheet Title
Project Title
Use of These Drawings
Scale:
Project Number:
Date:
Drawn By:
Project Engineer:
Approved By:
No. Description Date By
Revisions
478 BLAIR PARK ROAD | WILLISTON, VERMONT 05495
802 879 6331 | WWW.TCEVT.COM
ENGINEERING SURVEY
No. 9020
CIVILABIGAIL A.
D
E
RYSTATE O F VER
M
O
NT
PROF
E
SSIONAL
E N G INEERLICE N S E D
Field Book:
For Local Permitting Only
1. Unless otherwise noted, these Drawings are intended for
preliminary planning, coordination with other disciplines or
utilities, and/or approval from the regulatory authorities.
They are not intended as construction drawings unless noted
as such or marked approved by a regulatory authority.
2. By use of these drawings for construction of the Project,
the Owner represents that they have reviewed, approved,
and accepted the drawings, obtained all necessary permits,
and have met with all applicable parties/disciplines,
including but not limited to, the Engineer and the Architect,
to insure these plans are properly coordinated including, but
not limited to, contract documents, specifications,
owner/contractor agreements, building and mechanical
plans, private and public utilities, and other pertinent permits
for construction.
3. Owner and Architect, are responsible for final design and
location of buildings shown, including an area measured a
minimum five (5) feet around any building and coordinating
final utility connections shown on these plans.
4. Prior to using these plans for construction layout, the user
shall contact TCE to ensure the plan contains the most
current revisions.
5. These Drawings are specific to the Project and are not
transferable. As instruments of service, these drawings, and
copies thereof, furnished by TCE are its exclusive property.
Changes to the drawings may only be made by TCE. If
errors or omissions are discovered, they shall be brought to
the attention of TCE immediately.
6. It is the User's responsibility to ensure this copy contains
the most current revisions.
PLANNING ENVIRONMENTAL
SPAN: 600-188-11469 PARCEL:
1640-00600
Utility Plan
Overview
C3-01
5/14/2021
As Shown
19-268
ALR
AAD
600 Spear FJT, LLC
600 Spear Street
So. Burlington, Vermont
SEWER CONNECTION PLAN
1" = 80'-0"A
B UTILITY PLAN
1" = 40'-0"