HomeMy WebLinkAboutAgenda 06_1459 Shelburne RdISSUED FOR PERMIT REVIEW
NOT FOR CONSTRUCTION
C-0.00
EXISTING
CONDITIONS
164 Main Street, Suite 201 P: (802) 878-0375
Colchester, Vermont 05446 www.krebsandlansing.com
STANDARD GRAPHIC SCALE (1" = 20')
VALID WHEN PLOTTED ON 24" BY 36" MEDIA
0'
0"1"2"3"
10'20'40'60'
STAMP:
CALCULATIONS 1459 SHELBURNE ROAD:
EXISTING CONDITIONS:
·BUILDING COVERAGE: ±3,450 S.F. (0.08 ACRES) (11.3%)
·OVERALL IMPERVIOUS: ±10,550 S.F. (0.24 ACRES) (33.8%)
·FRONT YARD COVERAGE: ±2,450 S.F. (FRONT YARD AREA = 2,985 S.F.) (82.1%)
·±12 PARKING SPOTS
LOCATION MAP
SCALE: 1" = 1
2 MILE
1.ASPECTS OF PLAN ARE APPROXIMATE AND DERIVED
FROM VERMONT USGS, GIS FIGURES, AND AERIAL
PHOTOGRAPHY. AERIAL PHOTOGRAPHY DATED
APRIL 2018. ASPECTS FROM 1475 SHELBURNE ROAD
ARE DERIVED FROM PERMIT PLANS AND HAVE NOT
BEEN FIELD VERIFIED.
2.THE HORIZONTAL COORDINATE SYSTEM IS BASED ON
NAD83 VERMONT STATE PLANE 4400 (US SURVEY
FEET). ELEVATIONS ARE BASED ON THE NAVD88 (US
SURVEY FEET).
3.THE UTILITIES ARE NOT WARRANTED TO BE
COMPLETE. CONTRACTOR SHALL CONTACT DIG SAFE
BEFORE BEGINNING ANY EXCAVATION.
4.THIS IS IN NO WAY A BOUNDARY SURVEY. PROPERTY
LINES SHOWN ON THIS PLAN ARE FROM TAX MAP
INFORMATION PROVIDED BY THE CITY. PROPERTY
LINES HAVE BEEN ADJUSTED BASE ON
MONUMENTATION FOUND IN THE FIELD AND
EVIDENCE IN AERIAL PHOTOGRAPHY.
THE
HOMESTEAD
SCHOOL
1459 Shelburne Road (VT Route 7)
South Burlington, Vermont
OWNER:
ANTHONY SOCINSKI TRUST
533 TANNER ROAD
JEFFERSONVILLE, VERMONT 05464
APPROXIMATE PROPERTY LINES
EXISTING GRADE CONTOUR
LINES (5 FOOT INTERVALS)
EXISTING TREELINE
EXISTING GRADE CONTOUR
LINES (1 FOOT INTERVALS)
PLAN NOTES:LEGEND
IRON PIPE / CONCRETE
MONUNMENT FOUND
PROPERTY INFORMATION:
ADDRESS: 1459 SHELBURNE ROAD
PARCEL ID: 1540-01459
SPAN: 600-188-15810
GRANDLIST ACREAGE: 0.71 ACRES
ZONING: COMMERCIAL 2 (C2)
FRONT YARD BUILDING SETBACK: 30'
BACK YARD BUILDING SETBACK: 30'
SIDE YARD BUILDING SETBACK: 10'
MAXIMUM BUILDING COVERAGE:40%
MAXIMUM TOTAL LOT COVERAGE: 70%
EXISTING SEWER
LINE/MANHOLE
EXISTING STORM
LINE/MANHOLE/BASIN
EXISTING OVERHEAD
ELECTRIC LINE/POWER POLE
EXISTING UNDERGROUND POWER
EXISTING WATER
LINE/HYDRANT/VALVE/SHUTOFF
SURVEY CONTROL POINT
EXISTING SIGN
APPROXIMATE EASEMENTS
EXISTING GAS LINE/VALVE
SITE
LAT: N44° 25' 55.0"
LONG: W73° 12' 41.9"
APPLICANT:
REPERIO PROPERTIES, LLC
P.O. BOX 1133
WILLISTON, VERMONT 05495
3
PROPERTY INFORMATION:
OWNER: REPERIO PROPERTIES, LLC
ADDRESS: 1475 SHELBURNE ROAD
PARCEL ID: 1540-01475
SPAN: 600-188-16230
GRANDLIST ACREAGE: 1.04 ACRES
ZONING: COMMERCIAL 2 (C2)
CALCULATIONS 1475 SHELBURNE ROAD:
EXISTING CONDITIONS:
·BUILDING COVERAGE: ±4,700 S.F. (0.11 ACRES) (10.4%)
·OVERALL IMPERVIOUS: ±28,000 S.F. (0.64 ACRES) (61.8%)
·NO ADJUSTMENTS TO FRONT YARD COVERAGE
·41 PARKING SPOTS
THE
HOMESTEAD
SCHOOL
1459 Shelburne Road (VT Route 7)
South Burlington, Vermont
OWNER:
ISSUED FOR PERMIT REVIEW
NOT FOR CONSTRUCTION
C-1.00
PROPOSED
INFANT CARE FACILITY
SITE PLAN
ANTHONY SOCINSKI TRUST
533 TANNER ROAD
JEFFERSONVILLE, VERMONT 05464
APPROXIMATE PROPERTY LINES
EXISTING GRADE CONTOUR
LINES (5 FOOT INTERVALS)
EXISTING TREELINE
EXISTING GRADE CONTOUR
LINES (1 FOOT INTERVALS)
LEGEND
IRON PIPE / CONCRETE
MONUNMENT FOUND
164 Main Street, Suite 201 P: (802) 878-0375
Colchester, Vermont 05446 www.krebsandlansing.com
PROPERTY INFORMATION:
ADDRESS: 1459 SHELBURNE ROAD
PARCEL ID: 1540-01459
SPAN: 600-188-15810
GRANDLIST ACREAGE: 0.71 ACRES
ZONING: COMMERCIAL 2 (C2)
FRONT YARD BUILDING SETBACK: 30'
BACK YARD BUILDING SETBACK: 30'
SIDE YARD BUILDING SETBACK: 10'
MAXIMUM BUILDING COVERAGE:40%
MAXIMUM TOTAL LOT COVERAGE: 70%
EXISTING SEWER
LINE/MANHOLE
EXISTING STORM
LINE/MANHOLE/BASIN
EXISTING OVERHEAD
ELECTRIC LINE/POWER POLE
EXISTING UNDERGROUND POWER
EXISTING WATER
LINE/HYDRANT/VALVE/SHUTOFF
SURVEY CONTROL POINT
EXISTING SIGN
PROPOSED GRADE CONTOUR
LINES (5 FOOT INTERVALS)
PROPOSED GRADE CONTOUR
LINES (1 FOOT INTERVALS)
PROPOSED GAS LINE/VALVE
PROPOSED SEWER
LINE/MANHOLE
PROPOSED
UNDERGROUND POWER
PROPOSED WATER
LINE/HYDRANT/VALVE/SHUTOFF
STANDARD GRAPHIC SCALE (1" = 20')
VALID WHEN PLOTTED ON 24" BY 36" MEDIA
0'
0"1"2"3"
10'20'40'60'
STAMP:
APPROXIMATE EASEMENTS
PROPOSED FORCE MAIN
PROPOSED UNDERGROUND
COMMUNICATIONS
EXISTING GAS LINE/VALVE
APPLICANT:
REPERIO PROPERTIES, LLC
P.O. BOX 1133
WILLISTON, VERMONT 05495
CALCULATIONS 1459 SHELBURNE ROAD:
EXISTING CONDITIONS:
·BUILDING COVERAGE: ±3,450 S.F. (0.08 ACRES) (11.3%)
·OVERALL IMPERVIOUS: ±10,550 S.F. (0.24 ACRES) (33.8%)
·FRONT YARD COVERAGE: ±2,450 S.F. (FRONT YARD AREA = 2,985 S.F.) (82.1%)
·±12 PARKING SPOTS
PROPOSED CONDITIONS:
·BUILDING COVERAGE: ±4,480 S.F. (0.10 ACRES) (14.5%)
·OVERALL IMPERVIOUS: ±14,600 S.F. (0.34 ACRES) (47.2%)
·FRONT YARD COVERAGE: ±560 S.F. (FRONT YARD AREA = 2,985 S.F.) (18.8%)
·15 PARKING SPOTS
1.ASPECTS OF PLAN ARE
APPROXIMATE AND DERIVED
FROM VERMONT USGS, GIS
FIGURES, AND AERIAL
PHOTOGRAPHY. AERIAL
PHOTOGRAPHY DATED APRIL
2018. ASPECTS FROM 1475
SHELBURNE ROAD ARE DERIVED
FROM PERMIT PLANS AND HAVE
NOT BEEN FIELD VERIFIED.
2.THE HORIZONTAL COORDINATE
SYSTEM IS BASED ON NAD83
VERMONT STATE PLANE 4400 (US
SURVEY FEET). ELEVATIONS ARE
BASED ON THE NAVD88 (US
SURVEY FEET).
3.THE UTILITIES ARE NOT
WARRANTED TO BE COMPLETE.
CONTRACTOR SHALL CONTACT
DIG SAFE BEFORE BEGINNING
ANY EXCAVATION.
4.THIS IS IN NO WAY A BOUNDARY
SURVEY. PROPERTY LINES
SHOWN ON THIS PLAN ARE FROM
TAX MAP INFORMATION
PROVIDED BY THE CITY.
PROPERTY LINES HAVE BEEN
ADJUSTED BASE ON
MONUMENTATION FOUND IN THE
FIELD AND EVIDENCE IN AERIAL
PHOTOGRAPHY.
PLAN NOTES:
EXISTING WATER/WASTEWATER DESIGN FLOW:
·THERE IS NO EXISTING WW PERMIT FOR THE PROPERTY. PROPERTY HAS AN EXISTING RESIDENTIAL
HOME AND EXISTING BUSINESS DENSMORE MONUMENTS. BELOW ARE ASSUMED FLOWS BASED ON
THE WW SUPPLY RULES.
·2-BEDROOM RESIDENTIAL HOME = 280 GPD
·5 EMPLOYEES * 15 GPD PER EMPLOYEE = 75 GPD
·10 PATRONS PER DAY * 4 GPD PER PATRON = 40 GPD
·TOTAL = 395 GPD
STATE OF VERMONT PROPOSED WASTEWATER/WATER DESIGN FLOWS:
·PROPOSED USE IS A CHILD CARE FACILITY WHICH DOES NOT SERVE MEALS ON SITE. TOTAL AMOUNT
OF EMPLOYEES AND CHILDREN WHICH WILL USE THE PROPOSED FACILITY EQUALS 10 EMPLOYEES
AND 32 CHILDREN
·42 EMPLOYEES & CHILDREN * 13 GPD PER PERSON WITHOUT MEALS = 546 GPD
BASIS OF DESIGN FOR POTABLE
WATER AND WASTEWATER DESIGN FLOW
ALL VALUES CALCULATED BELOW WERE GENERATED USING VALUES PUBLISHED BY THE "INSTITUTE OF
TRANSPORTATION ENGINEERS (ITE) TRIP GENERATION MANUAL, 10TH EDITION". VALUES ARE LISTED AS VEHICLE
TRIP ENDS (VTE) BASED ON SPECIFIC USES IN THE MANUEL. MANUEL USE ANALYZED IS DAY CARE CENTER
BASED ON STUDENT POPULATION (MANUAL #565). BELOW IS THE EVALUATION.
STUDENTS FOR TRAFFIC CALCULATIONS:
·TOTAL STUDENTS FOR THE PROPOSED FACILITY ON 1459 SHELBURNE ROAD
·TOTAL OF 32 STUDENTS
ANALYSIS:TRAFFIC VALUES:
·WEEKDAY AVERAGE VTE = 32 STUDENTS * 4.09 VTE/PER STUDENT = 131 VTE
·WEEKDAY AM PEAK HOUR VTE = 32 STUDENTS * 0.79 VTE/PER STUDENT = 26 VTE
·WEEKDAY PM PEAK HOUR VTE = 32 STUDENTS * 0.81 VTE/PER STUDENT = 26 VTE
IN BOTH EVALUATIONS THE EFFECT ON TRAFFIC TO THE PROPOSED CHANGE IN USE HAS REMAINED RELATIVELY
THE SAME OR WITH A SLIGHT DECREASE.
PROJECT TRAFFIC
5
BIKE PARKING ONSITE WILL BE SHARED BETWEEN 1459 AND 1475 SHELBURNE ROAD PROPERTIES. THE TOTAL
SQUARE FOOTAGE OF BOTH BUILDINGS IS 13,200 S.F. (±4,500 + 8,700).
·SHORT TERM: 1 BIKE PARKING SPOT PER 5,000 S.F. OF BUILDING = 13,200 S.F. / 5,000 S.F. = 3 BIKE PARKING
SPOTS (MINIMUM 2 PER PROPERTY). PROJECT SHOWS 6 U-SHAPED SPOTS
·LONG TERM: 50% OF SHORT TERM. PROJECT IS REQUIRED 1 PER PROPERTY. 1459 PARCEL WILL PROVIDE
A LONG TERM BIKE SPOT IN ONE OF THE CLOSETS OF THE NEW BUILDING, WALL MOUNTED. 1475 PARCEL
HAS LONG TERM BIKE STORAGE IN BASEMENT.
·LOCKERS: BOTH BUILDINGS HAVE EMPLOYEE STORAGE WITHIN.
BIKE PARKING CALCULATIONS
PROPOSED TREELINE
PROPERTY INFORMATION:
OWNER: REPERIO PROPERTIES, LLC
ADDRESS: 1475 SHELBURNE ROAD
PARCEL ID: 1540-01475
SPAN: 600-188-16230
GRANDLIST ACREAGE: 1.04 ACRES
ZONING: COMMERCIAL 2 (C2)
CALCULATIONS 1475 SHELBURNE ROAD:
EXISTING CONDITIONS:
·BUILDING COVERAGE: ±4,700 S.F. (0.11 ACRES) (10.4%)
·OVERALL IMPERVIOUS: ±28,000 S.F. (0.64 ACRES) (61.8%)
·NO ADJUSTMENTS TO FRONT YARD COVERAGE
·41 PARKING SPOTS
PROPOSED CONDITIONS:
·BUILDING COVERAGE: ±4,700 S.F. (0.11 ACRES) (10.4%)
·OVERALL IMPERVIOUS: ±28,200 S.F. (0.65 ACRES) (62.2%) THE PROJECT WILL LIKELY
RESULT IN REMOVAL OF PORTIONS OF EXISTING PLAYGROUND FOR GRADING PURPOSES.
ALL PLAYGROUND WILL BE REPLACED WITH PERVIOUS PLAYGROUND SECTION.
·NO ADJUSTMENTS TO FRONT YARD COVERAGE
·41 PARKING SPOTS
>>>>>>>>>>>>>>>>THE
HOMESTEAD
SCHOOL
1459 Shelburne Road (VT Route 7)
South Burlington, Vermont
OWNER:
ISSUED FOR PERMIT REVIEW
NOT FOR CONSTRUCTION
C-1.01
PROPOSED
STORMWATER PLAN
ANTHONY SOCINSKI TRUST
533 TANNER ROAD
JEFFERSONVILLE, VERMONT 05464
APPROXIMATE PROPERTY LINES
EXISTING GRADE CONTOUR
LINES (5 FOOT INTERVALS)
EXISTING TREELINE
EXISTING GRADE CONTOUR
LINES (1 FOOT INTERVALS)
LEGEND
IRON PIPE / CONCRETE
MONUNMENT FOUND
164 Main Street, Suite 201 P: (802) 878-0375
Colchester, Vermont 05446 www.krebsandlansing.com
PROPERTY INFORMATION:
ADDRESS: 1459 SHELBURNE ROAD
PARCEL ID: 1540-01459
SPAN: 600-188-15810
GRANDLIST ACREAGE: 0.71 ACRES
ZONING: COMMERCIAL 2 (C2)
FRONT YARD BUILDING SETBACK: 30'
BACK YARD BUILDING SETBACK: 30'
SIDE YARD BUILDING SETBACK: 10'
MAXIMUM BUILDING COVERAGE:40%
MAXIMUM TOTAL LOT COVERAGE: 70%
EXISTING SEWER
LINE/MANHOLE
EXISTING STORM
LINE/MANHOLE/BASIN
EXISTING OVERHEAD
ELECTRIC LINE/POWER POLE
EXISTING UNDERGROUND POWER
EXISTING WATER
LINE/HYDRANT/VALVE/SHUTOFF
SURVEY CONTROL POINT
EXISTING SIGN
PROPOSED GRADE CONTOUR
LINES (5 FOOT INTERVALS)
PROPOSED GRADE CONTOUR
LINES (1 FOOT INTERVALS)
PROPOSED GAS LINE/VALVE
PROPOSED SEWER
LINE/MANHOLE
PROPOSED
UNDERGROUND POWER
PROPOSED WATER
LINE/HYDRANT/VALVE/SHUTOFF
STANDARD GRAPHIC SCALE (1" = 20')
VALID WHEN PLOTTED ON 24" BY 36" MEDIA
0'
0"1"2"3"
10'20'40'60'
STAMP:
APPROXIMATE EASEMENTS
PROPOSED FORCE MAIN
PROPOSED UNDERGROUND
COMMUNICATIONS
EXISTING GAS LINE/VALVE
APPLICANT:
REPERIO PROPERTIES, LLC
P.O. BOX 1133
WILLISTON, VERMONT 05495
1.ASPECTS OF PLAN ARE APPROXIMATE AND DERIVED
FROM VERMONT USGS, GIS FIGURES, AND AERIAL
PHOTOGRAPHY. AERIAL PHOTOGRAPHY DATED
APRIL 2018. ASPECTS FROM 1475 SHELBURNE ROAD
ARE DERIVED FROM PERMIT PLANS AND HAVE NOT
BEEN FIELD VERIFIED.
2.THE HORIZONTAL COORDINATE SYSTEM IS BASED ON
NAD83 VERMONT STATE PLANE 4400 (US SURVEY
FEET). ELEVATIONS ARE BASED ON THE NAVD88 (US
SURVEY FEET).
3.THE UTILITIES ARE NOT WARRANTED TO BE
COMPLETE. CONTRACTOR SHALL CONTACT DIG SAFE
BEFORE BEGINNING ANY EXCAVATION.
4.THIS IS IN NO WAY A BOUNDARY SURVEY. PROPERTY
LINES SHOWN ON THIS PLAN ARE FROM TAX MAP
INFORMATION PROVIDED BY THE CITY. PROPERTY
LINES HAVE BEEN ADJUSTED BASE ON
MONUMENTATION FOUND IN THE FIELD AND
EVIDENCE IN AERIAL PHOTOGRAPHY.
PLAN NOTES:
PRE-DEVELOPMENT PEAK FLOWS (CFS)
ANALYSIS POINT 10-YEAR 24-HOUR
STORM EVENT (QP10)
25-YEAR 24-HOUR
STORM EVENT (QP25)
SN001 1.43 2.38
100-YEAR 24-HOUR
STORM EVENT (QP100)
3.24 3.57
1-YEAR 24-HOUR
STORM EVENT (CPv)
POST-DEVELOPMENT PEAK FLOWS (CFS)
ANALYSIS POINT 1" STORM EVENT
(WQv)
10-YEAR 24-HOUR
STORM EVENT (QP10)
25-YEAR 24-HOUR
STORM EVENT (QP25)
SN001 0.04 0.05 0.42
100-YEAR 24-HOUR
STORM EVENT (QP100)
2.30 3.34
1-YEAR 24-HOUR
STORM EVENT (CPv)
1.SEE ALL NOTES, DETAILS, SPECIFICATIONS, AND
REQUIREMENTS ON DETAIL PAGES C-2.00, C-2.01,
C-2.02, C-2.03, AND C-2.04
ADDITIONAL STORMWATER NOTES
5PROPOSED TREELINE
PROPERTY INFORMATION:
OWNER: REPERIO PROPERTIES, LLC
ADDRESS: 1475 SHELBURNE ROAD
PARCEL ID: 1540-01475
SPAN: 600-188-16230
GRANDLIST ACREAGE: 1.04 ACRES
ZONING: COMMERCIAL 2 (C2)
THE
HOMESTEAD
SCHOOL
1459 Shelburne Road (VT Route 7)
South Burlington, Vermont
OWNER:
ISSUED FOR PERMIT REVIEW
NOT FOR CONSTRUCTION
C-1.02
EROSION PREVENTION AND
SEDIMENT CONTROL PLAN
ANTHONY SOCINSKI TRUST
533 TANNER ROAD
JEFFERSONVILLE, VERMONT 05464
APPROXIMATE PROPERTY LINES
EXISTING GRADE CONTOUR
LINES (5 FOOT INTERVALS)
EXISTING TREELINE
EXISTING GRADE CONTOUR
LINES (1 FOOT INTERVALS)
LEGEND
IRON PIPE / CONCRETE
MONUNMENT FOUND
164 Main Street, Suite 201 P: (802) 878-0375
Colchester, Vermont 05446 www.krebsandlansing.com
PROPERTY INFORMATION:
ADDRESS: 1459 SHELBURNE ROAD
PARCEL ID: 1540-01459
SPAN: 600-188-15810
GRANDLIST ACREAGE: 0.71 ACRES
ZONING: COMMERCIAL 2 (C2)
FRONT YARD BUILDING SETBACK: 30'
BACK YARD BUILDING SETBACK: 30'
SIDE YARD BUILDING SETBACK: 10'
MAXIMUM BUILDING COVERAGE:40%
MAXIMUM TOTAL LOT COVERAGE: 70%
EXISTING SEWER
LINE/MANHOLE
EXISTING STORM
LINE/MANHOLE/BASIN
EXISTING OVERHEAD
ELECTRIC LINE/POWER POLE
EXISTING UNDERGROUND POWER
EXISTING WATER
LINE/HYDRANT/VALVE/SHUTOFF
SURVEY CONTROL POINT
EXISTING SIGN
PROPOSED GRADE CONTOUR
LINES (5 FOOT INTERVALS)
PROPOSED GRADE CONTOUR
LINES (1 FOOT INTERVALS)
PROPOSED GAS LINE/VALVE
PROPOSED SEWER
LINE/MANHOLE
PROPOSED
UNDERGROUND POWER
PROPOSED WATER
LINE/HYDRANT/VALVE/SHUTOFF
STANDARD GRAPHIC SCALE (1" = 20')
VALID WHEN PLOTTED ON 24" BY 36" MEDIA
0'
0"1"2"3"
10'20'40'60'
STAMP:
APPROXIMATE EASEMENTS
PROPOSED FORCE MAIN
PROPOSED UNDERGROUND
COMMUNICATIONS
EXISTING GAS LINE/VALVE
APPLICANT:
REPERIO PROPERTIES, LLC
P.O. BOX 1133
WILLISTON, VERMONT 05495
1.ASPECTS OF PLAN ARE APPROXIMATE AND DERIVED
FROM VERMONT USGS, GIS FIGURES, AND AERIAL
PHOTOGRAPHY. AERIAL PHOTOGRAPHY DATED
APRIL 2018. ASPECTS FROM 1475 SHELBURNE ROAD
ARE DERIVED FROM PERMIT PLANS AND HAVE NOT
BEEN FIELD VERIFIED.
2.THE HORIZONTAL COORDINATE SYSTEM IS BASED ON
NAD83 VERMONT STATE PLANE 4400 (US SURVEY
FEET). ELEVATIONS ARE BASED ON THE NAVD88 (US
SURVEY FEET).
3.THE UTILITIES ARE NOT WARRANTED TO BE
COMPLETE. CONTRACTOR SHALL CONTACT DIG SAFE
BEFORE BEGINNING ANY EXCAVATION.
4.THIS IS IN NO WAY A BOUNDARY SURVEY. PROPERTY
LINES SHOWN ON THIS PLAN ARE FROM TAX MAP
INFORMATION PROVIDED BY THE CITY. PROPERTY
LINES HAVE BEEN ADJUSTED BASE ON
MONUMENTATION FOUND IN THE FIELD AND
EVIDENCE IN AERIAL PHOTOGRAPHY.
PLAN NOTES:
1.THE DIFFERENCE BETWEEN EXISTING GRADE AND
PROPOSED GRADE AS SHOWN ON THE PLANS
RESULTS IN THE FOLLOWING CUT/FILL VALUES.
·CUT = ±360 C.Y.
·FILL = ±600 C.Y.
2.THESE VALUES DO NOT INCLUDE THE MATERIAL
NEEDED FOR OR GENERATED FROM ROADWAY
INSTALLATION, STORMWATER BEST MANAGEMENT
PRACTICES, EXCAVATION FOR BUILDING FOOTINGS,
CONCRETE, ASPHALT, ETC. THE NUMBERS ABOVE
ARE A STRAIGHT COMPARISON BETWEEN SURFACES.
3.GRADES WILL BE ADJUSTED THROUGHOUT
CONSTRUCTION TO LIMIT THE NEED FOR OFFSITE
FILL. THE INTENT IT TO HAVE THE SITE BE BALANCED
SITE.
CUT/FILL NOTES
PROPOSED EROSION PREVENTION
AND SEDIMENT CONTROL SILT FENCE
PERIMETER CONTROLS AND
CONSTRUCTION LIMIT BARRIER FENCE
AREAS WHERE WATER DOES NOT FLOW
OFFSITE NEED ONLY CONSTRUCTION
LIMIT BARRIER FENCE
1.SEE ALL NOTES, DETAILS, SPECIFICATIONS, AND
REQUIREMENTS ON DETAIL PAGES C-2.00, C-2.01,
C-2.02, C-2.03, AND C-2.04
ADDITIONAL EPSC NOTES
5PROPOSED TREELINE
PROPERTY INFORMATION:
OWNER: REPERIO PROPERTIES, LLC
ADDRESS: 1475 SHELBURNE ROAD
PARCEL ID: 1540-01475
SPAN: 600-188-16230
GRANDLIST ACREAGE: 1.04 ACRES
ZONING: COMMERCIAL 2 (C2)
THE
HOMESTEAD
SCHOOL
1459 Shelburne Road (VT Route 7)
South Burlington, Vermont
OWNER:
ISSUED FOR PERMIT REVIEW
NOT FOR CONSTRUCTION
C-1.03
PROPOSED
LANDSCAPING PLAN
ANTHONY SOCINSKI TRUST
533 TANNER ROAD
JEFFERSONVILLE, VERMONT 05464
APPROXIMATE PROPERTY LINES
EXISTING GRADE CONTOUR
LINES (5 FOOT INTERVALS)
EXISTING TREELINE
EXISTING GRADE CONTOUR
LINES (1 FOOT INTERVALS)
LEGEND
IRON PIPE / CONCRETE
MONUNMENT FOUND
164 Main Street, Suite 201 P: (802) 878-0375
Colchester, Vermont 05446 www.krebsandlansing.com
PROPERTY INFORMATION:
ADDRESS: 1459 SHELBURNE ROAD
PARCEL ID: 1540-01459
SPAN: 600-188-15810
GRANDLIST ACREAGE: 0.71 ACRES
ZONING: COMMERCIAL 2 (C2)
FRONT YARD BUILDING SETBACK: 30'
BACK YARD BUILDING SETBACK: 30'
SIDE YARD BUILDING SETBACK: 10'
MAXIMUM BUILDING COVERAGE:40%
MAXIMUM TOTAL LOT COVERAGE: 70%
EXISTING SEWER
LINE/MANHOLE
EXISTING STORM
LINE/MANHOLE/BASIN
EXISTING OVERHEAD
ELECTRIC LINE/POWER POLE
EXISTING UNDERGROUND POWER
EXISTING WATER
LINE/HYDRANT/VALVE/SHUTOFF
SURVEY CONTROL POINT
EXISTING SIGN
PROPOSED GRADE CONTOUR
LINES (5 FOOT INTERVALS)
PROPOSED TREELINE
PROPOSED GRADE CONTOUR
LINES (1 FOOT INTERVALS)
PROPOSED GAS LINE/VALVE
PROPOSED SEWER
LINE/MANHOLE
PROPOSED
UNDERGROUND POWER
PROPOSED WATER
LINE/HYDRANT/VALVE/SHUTOFF
STANDARD GRAPHIC SCALE (1" = 20')
VALID WHEN PLOTTED ON 24" BY 36" MEDIA
0'
0"1"2"3"
10'20'40'60'
STAMP:
APPROXIMATE EASEMENTS
PROPOSED FORCE MAIN
PROPOSED UNDERGROUND
COMMUNICATIONS
EXISTING GAS LINE/VALVE
APPLICANT:
REPERIO PROPERTIES, LLC
P.O. BOX 1133
WILLISTON, VERMONT 05495
1.ASPECTS OF PLAN ARE APPROXIMATE AND DERIVED FROM VERMONT
USGS, GIS FIGURES, AND AERIAL PHOTOGRAPHY. AERIAL PHOTOGRAPHY
DATED APRIL 2018. ASPECTS FROM 1475 SHELBURNE ROAD ARE DERIVED
FROM PERMIT PLANS AND HAVE NOT BEEN FIELD VERIFIED.
2.THE HORIZONTAL COORDINATE SYSTEM IS BASED ON NAD83 VERMONT
STATE PLANE 4400 (US SURVEY FEET). ELEVATIONS ARE BASED ON THE
NAVD88 (US SURVEY FEET).
3.THE UTILITIES ARE NOT WARRANTED TO BE COMPLETE. CONTRACTOR
SHALL CONTACT DIG SAFE BEFORE BEGINNING ANY EXCAVATION.
4.THIS IS IN NO WAY A BOUNDARY SURVEY. PROPERTY LINES SHOWN ON
THIS PLAN ARE FROM TAX MAP INFORMATION PROVIDED BY THE CITY.
PROPERTY LINES HAVE BEEN ADJUSTED BASE ON MONUMENTATION
FOUND IN THE FIELD AND EVIDENCE IN AERIAL PHOTOGRAPHY.
PLAN NOTES:
VEGETATION AND INSTALLATION SCHEDULE FOR PLANTINGS
QUANTITY COMMON NAME PURCHASE SIZE MATURE SIZE APPROX. COST PER PLANT TOTAL COST
2 AUTUMN GOLD GINKO BILOBA 3 INCH MIN. CALIPER 20' - 30' HIGH $900 PER PLANT $1,800
3 NEW HORIZON ELM 3 INCH MIN. CALIPER 30' - 40' HIGH $900 PER PLANT $2,700
2 MARMO FREEMANII MAPLE 3 INCH MIN. CALIPER 40' - 50' HIGH $1,200 PER PLANT $2,400
29 HUMMINGBIRD SUMMERSWEET 5 GALLON 3' - 5' DIAMETER $120 PER PLANT $3,480
16 DWARF FRAGRANT SUMAC 5 GALLON 2' - 3' DIAMETER $85 PER PLANT $1,360
12 SWAMP AZALEA 5 GALLON 3' - 5' DIAMETER $120 PER PLANT $1,440
4 HYDRANGEA ARBORESCENS 3 GALLON 3' - 5' DIAMETER $85 PER PLANT $340
$13,520
NOTE: REMOVE ALL NON-BIODEGRADABLE
MATERIAL FROM PLANT PIT
TREE
SUPPORT
ANCHOR
CUT AND REMOVE ANY
WIRE, ROLL BURLAP
BACK FROM TOP 1/3 OF
ROOTBALL BEFORE
BACKFILLING; UNTIE
ROPE FROM TRUNK
EXISTING
SUBGRADE 6" COMPACTED
PLANTING MIXTURE
FINISH
GRADE
PLANTING MIXTURE.
LOAM/SANDY LOAM
TEMPORARY
LANDSCAPE
SOIL SAUCER
REINFORCED
RUBBER HOSE
TREE TO BE
SET PLUMB
SHREDDED BARK
MULCH, 3" MIN. DEPTH
TRUNK
TRANSITION
GUYING MATERIAL (GUYING
WIRE, 3 PER TREE)
CROWN TO BE PRUNED AS
DIRECTED BY ARCHITECT -
DO NOT CUT LEADER
SMALL SHRUBS SHALL BE
INSTALLED USING SIMILAR
SUBBASE MATERIAL, MAY
NOT NEED TREE SUPPORT.
TREE PLANTING IN LANDSCAPE DETAIL
N.T.S.
H
5
MINIMUM LANDSCAPING PER THE CITY OF SOUTH BURLINGTON REGULATIONS.
THE MINIMUM IS BASED ON THE PROPOSED PROJECT COTS. THIS PROJECT'S
PRELIMINARY COST IS $1,400,000.
·3% FOR THE FIRST $250,000 = $7,500
·2% FOR THE SECOND $250,000 = $5,000
·1% FOR THE REMAINING COSTS OVER $500,000 = ($900,000 REMAINING) $9,000
TOTAL = $7,500 + $5,000 + $9,000 = $21,500
LANDSCAPING BUDGET CALCULATION:
·PROPOSED LANDSCAPING IN SCHEDULE = $13,520
·KEEPING EXISTING 18" MAPLES = $3,600
·480 S.F. BACK PATIO = $4,800
·230 S.F. FRONT SIDEWALK = $2,300
$24,220
COST BREAKDOWN:24" MIN.PROPERTY INFORMATION:
OWNER: REPERIO PROPERTIES, LLC
ADDRESS: 1475 SHELBURNE ROAD
PARCEL ID: 1540-01475
SPAN: 600-188-16230
GRANDLIST ACREAGE: 1.04 ACRES
ZONING: COMMERCIAL 2 (C2)
March 31, 2022
Marla Keene
Development Review Planner
City of South Burlington
180 Market Street
South Burlington, VT 05403
Re: 1459 Shelburne Road – Revisions to Plans and Addressing Staff Comments (for April 5th meeting)
Dear Marla,
Attached with this letter are additional project materials. Please review and let us know if there are any other
revisions we can add before our meeting on April 5, 2022. Below we have outlined the highlighted Staff
Comments and how we addressed them in the resubmission.
1. The front brick walkway may add a limited amount of value to the site because of its limited
visibility and limited anticipated use. Staff recommends the Board consider whether to allow the
front brick walkway to contribute towards the minimum required landscaping value or whether
other site features, such at the planned playground, may be a better use of required value. If the
playground or other site features are used, full details and cost information are required.
As discussed on our call, the project owner intends to create a garden around the walkway for the front
entrance. The project also disagrees with the visibility assessment, this is the front of the building, the walk
and planned garden will add curb appeal to the building from views along Shelburne Road. This will be the
view of the proposed project for the majority of the public viewing the property.
2. For the brick patio (and brick walkway if allowed), Staff recommends the Board require the
applicant to provide a detailed cost breakdown demonstrating that the requested hardscape
value is only the value beyond the value of standard concrete.
It is difficult to have a concrete company perform a proposal for work that will not be done. In my experience
on other projects pouring a reinforced concrete slab with finishing will be between 6-7 dollars per square
foot. This cost does not include any of the subbase installation and preparation. Between the front walk and
the back patio there are 710 s.f., which would cost approximately $4,970 at $7 per s.f. DiStefano Landscaping
provided a cost opinion for the installation of 4x8 Holland Stone Charcoal Pavers for the same space with
subbase prepared by others for $12,211.25. The difference in costs is more than $7,200 between concrete
and the pavers. My calculation of an additional $10 per square foot on the plans yielded $7,100 for the two
spaces which is more conservative.
3. Staff recommends the Board require the applicant to increase the minimum tree size and
recalculate the proposed landscaping cost, adding on-site plantings as necessary to achieve the
required minimum landscaping budget.
The project made the requested revision please see updated landscape schedule. We increased the size of
many of the plants proposed on site and I researched costs online. The new breakdown excludes prep and
material and is just the plants. Plants value now add to $13,520, combined with leaving the existing tree,
walk and patio the overall landscaping number is $24,220.
4. The Board on 3/2 supported the City Arborists suggestion to require the applicant to retain the
18-inch maple. Staff continues to recommend the Board require the applicant to modify their
erosion prevention and sediment control plan to provide robust tree protection around the drip
edge of the existing tree.
As discussed in the March 17, 2022, letter, number 13. An 18” caliper tree on average has a 18’ diameter drip
edge, this tree is in the middle of the site. There are sidewalks, the building, grading, fence, etc. which will all
be installed within the limits of the existing trees drip edge. The project has agreed and revised the project
plans to keep/maintain the existing tree and during construction will protect the tree to the greatest extent
practical. Further notes were added to protect the tree’s drip edge to the extent practical on the plans.
5. The Board has historically applied this standard across parking lots regardless of property
boundaries. This criterion is not met for the parking lot shared by this and the adjacent parcel to
the south. Staff recommends the Board require the applicant to demonstrate how they will
meet this criterion for the shared parking lot prior to closing the hearing. Staff anticipates the
actual interior landscaping will be provided on the adjacent parcel to the south.
The southern property is an existing parking lot which has existing parking islands in the corners and in front
of the building. This is an attractive and well landscaped lot and the project feels it meets the intent the City’s
regulations. Further, the project will be adding two parking islands shown on the site plan which will loosely
separate the new project with the existing building. These parking islands will be on the 1475 Shelburne Road
property. The overall parking area in the lot is approximately 12,000 s.f. There is a total of 1,250 s.f. of
parking islands shown on 1475 Shelburne Road with the addition of the two new islands.
6. The applicant has not proposed any on-site snow storage. Staff notes the applicant has indicated
three areas on the adjoining site plan as “additional snow storage.” One area contains a mature
tree between the parking and the indicated area. Staff recommends the Board ask the applicant
to describe how snow storage will be addressed for the subject property.
The project plans indicate that all swale areas will be used for snow storage. The basin is not intended to be
used for snow storage, but the swales will be. This is identified on the site plan C-1.00. The proposed one-way
entrance for the project does not provide the plow ample space to push snow in multiple directions. Our
thought is the plow will push much of the snow around to the dumpster location as indicated on the plans.
This is a long straight shot for the plow and makes the most sense. There will be snowbanks on either side of
the roadways and at the edge of the parking lots.
To give the children the most outdoor space as possible, there is little space for a giant snow pile area.
Further, the children enjoy snow piles and playing in the snow. If snow becomes a problem the applicant is
willing to pile snow in 2-3 parking spaces for temporary storage and to allow for play.
7. Staff recommends the Board require the applicant to provide trees with a minimum of 2 ½
inches at the time of installation.
This has been revised. See landscape plan.
8. On March 2, the Board briefly reviewed these criteria and did not voice any opposition. Staff
recommends the Board confirm they are satisfied these criteria are met.
Project already reviewed this with the board, happy to have further discussions as needed.
9. The proposed site layout is strongly integrated into the site layout for the adjacent property to
the south. Staff recommends the Board include a condition of approval that this project may not
obtain a zoning permit before a site plan approval for the adjacent site is obtained.
The project has quickly worked to submit an application for the property revisions on 1475 Shelburne Road
for this project. We have always considered this project as one but understand the need for an additional
application for 1475 Shelburne Road. Application was submitted with plans and fee on March 31, 2022.
10. The March 2 staff report included the comment that the proposed one-way signage was not in a
location which will be useful to users of the site. The applicant provided an additional one-way
sign on the curve of the driveway but retained the one-way sign at the entrance on Shelburne
Road. Staff recommends that sign be relocated to be just east of the first five parking spaces, as
that is the first location where people could inadvertently go the wrong way. If the applicant
wishes to retain the sign at the entrance, they may, but Staff still considers a sign east of the
first five spaces to be needed.
Project added a third sign at location identified by staff.
11. The applicant has shown a fence on the plans, but no fence details are provided. Staff
recommends the Board require the applicant to provide a fence detail demonstrating
compliance with the LDR. If the applicant can provide a general description of the fence, Staff
considers provision of a detail can be a condition of approval.
As outlined in the application and our discussions the fence will look exactly like the existing fence at 1475
Shelburne Road. We have included pictures for the boards review.
Thank you for your time reviewing the project. We look forward to your review and input. Please reach out
if there are any additional comments, questions, or concerns.
Sincerely,
Greg Dixson, P.E.
Krebs and Lansing Consulting Engineers, Inc.
CC: Jeff O’Hara
Leigh Lamphere
Kelley DesRoches