Loading...
HomeMy WebLinkAboutZP-22-036 - 0150 Kennedy Drive 3/2/2022WDREF.REF.RECEPTIONVESTIBULEBATHOFFICECONSULTATION ROOMCONSULTATION ROOMCONSULTATION AREACONSULTATION AREASTORAGE/UTILITYADJACENT TENANTCLOSED OFF DOOR8' - 4"6' - 9 1/2"6' - 10"10' - 0"15' - 4"10' - 10"7' - 0"12' - 11"9' - 9"10' - 1 1/2"3' - 8 1/2"9' - 1"1' - 6"5' - 2"9' - 3"8' - 3"OXYLIFE C2OXYLIFE I/90TREATMENT ROOM #1TREATMENT ROOM #2TREATMENT ROOM #3[EXIST.]NURSE OFFICEBREAK ROOMNURSE PREP/LABBATHADA BATH[EXIST.]VESTIBULE[EXIST.]+/- 8' - 4"+/- 5' - 3"9' - 6"9' - 6"+/- 5' - 11"6' - 8"+/- 9' - 9"SUPPLEMENT CLOSET+/- 10' - 1 1/2"+/- 3' - 8 1/2"4' - 6"12" MIN.12" MIN.12" MIN.11' - 0"4' - 6"BLOOD DRAW CHAIR/CURTAIN307030703070FLIP DOOR SWINGNEW STAFF BATHROOM3070NEW WALLS AROUND H.W.H.2470O2IV/HYPERBARIC3070FLIP DOOR SWINGREMOVED WALLS (DASHED)REMOVED WALLS (DASHED)UNDER COUNTER REF.FROST ENTIRE GLASS PANEL5' - 6"CLOSED OFF DOORVERIFY 1-HR RATEDALIGN NEW WALL W/ EXIST.ADJACENT TENANTEXIST. COUNTER, SINK & CABS.CONTR-OLLERCONTR-OLLERDIRTY LINEN CLST.LIN.+/- 5' - 3"2' - 6"3' - 0"18" MIN.COAT CLST.ALIGN WALLS W/ WINDOW8' RAD. COUNTER42" HT. 34" HT. (ADA) 12" MIN.24702470OPNG-3070NEW 4' COUNTER/ CAB EXTENSION, COORD/ W/ OWNER4' - 0"DOUBLE LOCKABLE WALL HUNG CAB. IN EACH TREATMENT ROOM & NURSE OFFICE, COORD. W/ OWNERO2O2 CONCENTRATORS*SEE NOTE #2*18" MIN.18" MIN.36" MIN.60" MIN.COAT RACK (PER OWNER)48" MIN. CLEAR3' - 1"2' - 1"30703070(EXIST.)(EXIST.)(EXIST.)(EXIST.)3070CONTRACTOR TO VERIFY EXIST. SEPARATION WALL IS 1-HR RATED (RED DASH)ENTRYREINFORCE WALL FOR WALL SIGNAGE, COORD. W/ OWNER= EXISTING WALL= EXIST. 1-HR RATED WALL= REMOVED WALL= NEW WALLWALL KEYSHEET TITLE:THIS DRAWING IS THE PROPERTY OF G4 DESIGN STUDIOS, LLC AND IS NOT TO BE COPIED, REPRODUCED, OR THE CONTENT THEREOF USED, IN WHOLE OR IN PART, WITHOUT THE PRIOR WRITTEN CONSENT OF STEVE GUILDSCALE:DATE:DRAWN BY:CHECKED BY:PROJECT:DRAWING FOR CONSTRUCTION2/18/2022 12:21:16 PMAs indicatedA-1FLOORPLANS150 KENNEDY DRIVESTRAM CENTERG4WGI2/14/2022STRAMSOUTH BURLINGTON, VT1/4" = 1'-0"1EXISTING FLOOR PLAN1/4" = 1'-0"2PROPOSED FLOOR PLANBOMA AREA = +/-1,788 sqft*NOTE*ALL EXISTING DIMENSIONS SHOWN ARE +/-VERIFY IN FIELD PRIOR TO ANY CONSTRUCTIONBOMA AREA = +/-1,788 sqft*NOTES*1) ALL NEW TREATMENT ROOM, NURSE OFFICE, AND IV/HYBERBARIC CHAMBER WALLS TO BE FILLED W/ 3" 'QUIETZONE' SOUND BATT INSUL.2) (2) O2CONCENTRATORS TO BE PLACED ON FLOOR BETWEEN CHAMBERS, REMAINING (4) TO BE PLACED ON A SHELF ABOVE FLOOR CONCENTRATORS & I/90 CHAMBER. CONTRACTOR TO DETERMINE STRUCTURE NEEDED TO SUPPORT WEIGHT OF CONCENTRATOR UNITS AND LOCATION OF BRACKETS/LEGS TO SUPPORT SHELF.COORDINATE W/ OWNER FOR CLEARANCE REQS. BETWEEN CONCENTRATOR UNITS.3) CONTRACTOR TO COORD. W/ OWNER FOR ALL EQUIP. INSTALLATION REQUIREMENTS & PREPERATION REF.• VERMONT FIRE & BUILDING SAFETY CODE 2015 (VTFB)• NFPA101 LIFE SAFETY CODE 2015 (NFPA)• NFPA 1 UNIFORM FIRE CODE 2015• VERMONT ELECTRICAL SAFETY RULES 2017 (VTEL)• VERMONT PLUMBING RULES 2018 (VTPL)• VERMONT ACCESS RULES 2012 (VTAR)• ADA STANDARDS FOR ACCESSIBLE DESIGN 2010 (ADA) APPLICABLE CODES, STANDARDS AND REGULATIONS:BOMA RENTABLE AREA:+/-1,788 sqftGROSS INTERIOR OCCUPIABLE AREA: +/-1,656 sqftOCCUPANCY: BUSINESS (B)-NFPA 101 A.3.3.190.3 (6) DOCTORS' OFFICECONSTRUCTION TYPE: UNKNOWNSPRINKLERED: NOSUMMARY:CONCENTRATED BUSINESS OCCUPANT FACTOR: 50 sqft/PERSON (GROSS AREA)1,656/50 = 33.12 (34 OCCUPANTS)OCCUPANT LOAD (NFPA 101 TBL. 7.3.2.1):38.2.4.3 -A SINGLE EXIT SHALL BE PREMITTED FROM AN AREA WITH THE FOLLOWING:-LESS THAN 100 OCCUPANTS-EXIT DISCHARGE DIRECTLY TO OUTSIDE AT LEVEL OF EXIT DISCHARGE FOR BUILDING-TOTAL TRAVEL DISTANCE SHALL NOT EXCEED 100'-TOTAL TRAVEL DISTANCE SHALL BE ON THE SAME LEVEL[ONLY ONE EXIT IS REQUIRED FOR SPACE, TWO ARE PROVIDED]38.2.5.2.2 -DEAD-END CORRIDORS SHALL NOT EXCEED 20' (NON SPRINKLERED BUILDING)38.2.5.3.3. -COMMON PATH OF TRAVEL SHALL NOT EXCEED 75' (NON SPRINKLERED BUILDING)38.2.6.2 -TRAVEL DISTANCE TO EXIT SHALL NOT EXCEED 200' (NON SPRINKLERED BUILDING)38.3.2 -PROTECTIONS FROM HAZARDS SHALL BE IN ACCORDANCE WITH SECTION 8.78.7.5 -HYPERBARIC FACILITIES SHALL COMPLY WITH NFPA 99, CHAPTER 14[THE HYPERBARIC CHAMBERS PROPOSED FOR THIS FACILITY WILL PRESSURIZE UNALTERED AMBIENT AIR TO A MAX. PRESSURE OF 50kpa (~7.3 psi), WHILE IN THE CHAMBER, USERS WILL WEAR OXYGEN MASKS, THE CHAMBER ITSELF WILL NOT BE ENRICHED WITH OXYGEN]NFPA 99 DOES NOT APPLY TO THESE SPECIFIC HYPERBARIC CHAMBERS(AHJ TO VERIFY & COORDINATE DETAILS WITH TENANT)SPECIFIC OCCUPANCY CODE (NFPA 101 CHP. 38):EXITEXIT83'-8"58'-9"16' DEAD-END1-HR FIRE SEPARATION WALL (RED DASH)18" MIN.60" MIN.FRONT APPROACH, PULL SIDEFRONT APPROACH, PUSH SIDE('X' = 12" MIN. IF DOOR IS EQUIPPED WITH CLOSER & LATCH)48" MIN.XHINGE APPROACH, PULL SIDE36" MIN.60" MIN.HINGE APPROACH, PULL SIDE42" MIN.54" MIN.HINGE APPROACH, PUSH SIDE(ADD 6" TO 42" IF DOOR IS EQUIPPED WITH CLOSER & LATCH)LATCH APPROACH, PULL SIDE(ADD 6" TO 48" IF DOOR IS EQUIPPEDWITH CLOSER & LATCH)42" MIN.22" MIN.48" MIN.24" MIN.LATCH APPROACH, PUSH SIDE(ADD 6" TO 42" IF DOOR IS EQUIPPED WITH CLOSER & LATCH)24" MIN.42" MIN.48" MIN.POCKET, FRONT APPROACHPOCKET, HINGE APPROACH42" MIN.22" MIN.POCKET, LATCH APPROACH24" MIN.42" MIN.OPENING, SIDE APPROACH42" MIN.SHEET TITLE:THIS DRAWING IS THE PROPERTY OF G4 DESIGN STUDIOS, LLC AND IS NOT TO BE COPIED, REPRODUCED, OR THE CONTENT THEREOF USED, IN WHOLE OR IN PART, WITHOUT THE PRIOR WRITTEN CONSENT OF STEVE GUILDSCALE:DATE:DRAWN BY:CHECKED BY:PROJECT:DRAWING FOR CONSTRUCTION2/18/2022 12:21:19 PMAs indicatedA-2CODEREVIEW/DETAILS150 KENNEDY DRIVESTRAM CENTERG4WGI2/14/2022STRAMSOUTH BURLINGTON, VT3/16" = 1'-0"1CODE REVIEW PLANADA DOOR CLEARANCES