Loading...
HomeMy WebLinkAboutZP-22-039 - 0210 Two Brothers Drive 3/1/202222-039 03/01/2022 1,230.35 R12 Single Family Dwelling 8/17/17 (#SD-17-17) 03/01/2022 03/16/2022 03/15/2023 Acting   VIA HAND‐DELIVERY    January 24, 2022    Ms. Dalila Hall, Administrative Officer  South Burlington Planning and Zoning   180 Market Street  South Burlington, VT 05403      Re:   Zoning Permit Application 210 Two Brothers Drive, South Burlington, VT 05403     Dalila,    Further to Final Plat Permit SD‐17‐17, enclosed please find a zoning permit application  for 210 Two Brothers Drive, South Burlington, Vermont 05403, Unit 051 on the Final Plat/Site  Plan submitted as part of SD‐17‐17.    As summarized below, we are currently not requesting any identical homes or exceptions  to what has been permitted per the Final Plat Permit #SD‐17‐17.     Existing Proposed  Identical Elevations on adjoining lots or  across the street  No No  No Identical Elevations more than 2x  on Laurentide Ln  No No  No Identical Elevations more than 2x  on Ledge Way  Yes No  No Identical Elevations more than 2x  on Split Rock Court  No No  No Identical Elevations more than 3x  on Two Brothers Dr  No No  No Identical Elevations more than 3x  on Downhill O’Brien Farm Rd  No No  No Identical Elevations more than 3x  on uphill O’Brien Farm Rd  No No  No single‐color palate more than 10x in  subdivision  No No    This application requires a sewer connection and allocation.  Attached please find  required sewer and water allocation forms as well.     Please contact us with any questions or concerns.            Sincerely,           Brandon Secl, Estimator   Property Owners Name:O'Brien Farm Road, LLC Property Location:210 Two Brothers Drive Amount:7,572.19 Payment Type:check #006242 Date:3/1/2022 Code Zoning Permit (New Residential)ZP-22-039 zp Recording fee 13.00$ plus 2211 0.45$ per sq. ft. 994.95$ plus 612 0.20$ per sq. ft. 122.40$ plus 2 50.00$ per bay 100.00$ plus After-the fact of 50% [no NOV] or 100% [NOV] -$ Zoning Permit Total 1,230.35$ Sewer Allocation Fee WWA-22-106 #204 242.95 g.p.d x 13.06$ 3,172.93$ Bartlett Bay x Airport Parkway Recreation Impact Fee #220 1,665.08$ South Village Recreation Impact Fee #243 -$ Road Impact Fee #221 944.89$ Fire Impact Fee #203 -$ Police Impact Fee #222 495.94$ Dorset Street Waterline Fee #230 -$ Sewer Connection Inspection WW-22-06 ww 63.00$ 63.00$ Total (Impact Fees + Permit) 7,572.19$ Planning & Zoning Invoice Residential Impact & Permit Fees garage bay(s) at Amount Due sq. ft building at sq. ft unfinished basement at JOB NO:DRAWN:PROJ MGR:CHECKED:ISSUE DATE:O'Brien Home Farm Single Family Uphill LotSouth Burlington, VermontAGN0.109/01/17COVER SHEET, SHEETINDEXSHEET INDEXA4.1.2 FOUNDATION & PARTIAL FINISHEDWALKOUT PLANAGN0.1 COVER SHEET, SHEET INDEXAGN0.2 GENERAL NOTESE0.1.1A BEDROOM & BATH WALKOUT ELECTRICALA0.1A FOUNDATION/ LOWER LEVEL PLANA1.1A MAIN FLOOR PLANA3.1A EXTERIOR ELEVATIONS & ROOF PLAN-AA4.2.1A OPT. COVERED DECK-AA6.1A BUILDING SECTIONS-AA6.2A BUILDING SECTIONS-AA0.1C FOUNDATION/ BASEMENT PLAN-CA1.1C MAIN FLOOR-CA3.1C EXTERIOR ELEVATIONS & ROOF PLAN-CA6.1C BUILDING SECTIONS-CA6.2C BUILDING SECTIONS-CA4.2.2 OPT. MUDROOM PLANSA4.1.1 FOUNDATION/FINISHED BASEMENTA4.2.1 OPT. FLOOR PLANSA5.1 STAIR SECTIONELECTRICALE0.1A WALKOUT ELECTRICAL PLAN-AE1.1A MAIN FLOOR ELECTRICAL PLAN-AE0.1C WALKOUT ELECTRICAL PLAN-CE1.1C MAIN FLOOR ELECTRICAL PLAN-CE4.1.1 BEDROOM & BATH WALKOUT ELECTRICALSTRUCTURALS0.1A MAIN FLOOR FRAMING PLAN-AS1.1A ROOF FRAMING PLAN-AS0.1C MAIN FLOOR FRAMING PLAN-CS1.1C ROOF FRAMING PLAN-CAD.4 CABINET PLANSAD.1 DETAILSAD.2 DETAILSAD.3 DETAILSSquare Footages-AELEVATION ABASEMENT LIVING 492 SFMAIN FLOOR LIVING 1719 SFTOTAL LIVING 2211 SFBluebellPLAN OPTIONSBASEMENT BEDROOM/BATH 211 SFSouth Burlington, VermontO'Brien Home FarmSingle Family Uphill Lot BluebellFarmhouse Elevation - AREVISIONS CONSTRUCTION ASSEMBLIES:T THE FOLLOWING KEYNOTES REFERENCE THE SYMBOLS AS SHOWN ON PLANSA. ROOF CONSTRUCTION:COMPOSITION ROOF SHINGLES ON UNDERLAYMENT ON ROOF SHEATHING ON ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD OVER MOISTURE VAPOR RETARDER WITH INSULATION ABOVE.B1. TYPICAL SIDING WALL CONSTRUCTION:SIDING ON WATER RESISTANT BARRIER ON EXTERIOR WALL SHEATHING ON 2x4 STUDS, 16" O.C. OR 2x6 STUDS, 24" O.C. W/ INSULATION IN CAVITIES.INTERIOR: 1/2" GYPSUM BOARD OVER MOISTURE VAPOR RETARDER.B2. TYPICAL STONE VENEER WALL CONSTRUCTION:ADHERED SYNTHETIC STONE VENEER (INSTALLED PER MFR'S SPECS.) OVER WATER RESISTANT BARRIER ON EXTERIOR WALL SHEATHING ON 2x4 STUDS, 16" O.C. OR 2x6 STUDS, 24" O.C. W/ INSULATION IN CAVITIES.INTERIOR: 1/2" GYPSUM BOARD OVER MOISTURE VAPOR RETARDER.C. TYPICAL FLOOR CONSTRUCTION:FINISHED FLOORING ON 3/4" FLOOR SHEATHING ON FLOOR FRAMING AS NOTED ON STRUCTURAL DRAWINGS.MAIN FLOOR CEILING: 1/2" GYPSUM BOARD.D. CONCRETE SLAB CONSTRUCTION:4" CONCRETE SLAB OVER 6 MIL. POLYETHYLENE VAPOR BARRIER OVER 4" MINIMUM GRANULAR FILL.SYMBOLTYPESIZEFOOTING SCHEDULEF-PPIER (EXTERIOR)REINFORCING12" SONOTUBE W/ BELL BOTTOMNAF-C CONTINOUS FOOTING2'-0" WIDE x 0'-8" DEEP 3-#4's CONTINUOUSF-2PAD FOOTING (INTERIOR) 2'-0" x 2'-0" x 1'-0" DEEP NACOLUMN6x6 TREATED POSTNA*NOTE: LALLY COLUMNS SHALL HAVE THE ALLOWABLE MINIMUM LOAD CAPACITY OUTLINED IN THE GENERAL NOTES. SEE GENERAL NOTES FOR BOTTOM AND TOP BEARING PLATES.COMMENTS48" MIN. BELOW FINISH GRADE3 1/2" LALLY COLUMN UNLESS NOTED OTHERWISE*SYMBOLWALL THICKNESSWALL HEIGHTFOUNDATION WALL SCHEDULEW-8 8"9'-0"REINFORCING2 #4 BARS TOP & BOTTOM*CONTINUOUS FOOTING1'-4"x 0'-8" W/ 2-#4's CONTINUOUS*IF FOOTING IS BEARING ON EARTH BUILDER TO VERIFY SOIL PRESSURE AND USE 2'-0"x0'-8" CONTINUOUS FOOTINGGENERAL BASEMENT PLAN NOTES:* ALL UNDIMENSIONED PARTITIONS ( ) ARE 3 1/2" ROUGH UNLESS NOTED OTHERWISE.* IF MAIN FLOOR FRAMING IS TO BE INSTALLED BEFORE CONCRETE FLOOR, PROVIDE THE FOLLOWING:** AT PAD FOOTINGS, PROVIDE 8"x8" CONCRETE PEDESTAL FLUSH WITH CONCRETE FLOOR FOR ATTACHMENT OF POST BASE** AT CONTINUOUS FOOTINGS UNDER FRAMING BEARING WALLS, PROVIDE 6" WIDE CONTINUOUS CONCRETE STEM, TOP OF STEM FLUSH WITH CONCRETE FLOOR & CENTERED ON FOOTING.* ALL ANGLED PARTITIONS ARE 45 DEGREES UNLESS NOTED OTHERWISE.* ALL EXTERIOR DIMENSIONS ARE TO FACE OF STUDS UNLESS NOTED OTHERWISE.* WINDOW SUPPLIER TO VERIFY AT LEAST ONE WINDOW IN ALL BEDROOMS MEETS ALL EMERGENCY EGRESS REQUIREMENTS.* ALL ELECTRICAL AND MECHANICAL EQUIPMENT, METER LOCATIONS, ETC SHALL BE CONFIRMED BY MECHANICAL AND ELECTRICAL CONTRACTORS. CONTRACTORS SHALL COORDINATE WITH BUILDER PRIOR TO RELOCATION OF EQUIPMENT AND METERS.* ALL TRUSSES TO BEAR ON EXTERIOR WALLS AND/OR GIRDER TRUSS UNLESS NOTED OTHERWISE.* TRUSS MFG. TO SIZE MEMBERS, FASTENERS, HANGERS & SET SPACING FOR ALL TRUSSES.* FOR ADDITIONAL INFORMATION SEE GENERAL NOTES AND DETAILS.* TYPICAL WINDOW HEAD HEIGHTS SHALL BE 7'-0" A.F.F. (U.N.O.)* PROVIDE BLOCKING FOR ALL GRABBARS IN BATH, SEE DETAILS.2A6.1A3A6.2A1A6.1A1A5.1FURN306826683050 DH 3050 DH2 Car GarageUP 15 RISERS16070 OGD40'-0"11'-8"15'-0"13'-4"6'-0" 4'-0"38'-0"10'-0"6'-0"22'-8"19'-4"4'-0" 6'-0"11'-4"8'-0"20'-8"40'-0"6'-2" 6'-2"27'-8"38'-0"4'-0" 6'-0"8' - 9" CLGUnfinished Basement11'-9 1/2" 3'-8 1/2" 3'-9 1/2"18'-0"5'-7" 13'-5" 3'-8" 8"8" 4 1/2"26'-1 1/4"6'-1 3/4" 6'-0 1/2" 8"122125128127132F-21471471301421261481481488" 6'-10" 6'-10" 8"2'-5 3/4"5 1/4"5'-8 3/4"12458'-0"58'-0"5'-10" 5'-6" 2'-0" 4'-0" 2'-0" 10'-4"10'-4"Mudroom3068HOSE BIB40681223'-4" 3'-10"1'-4"MECHANICALS TO BE LOCATEDAT FULL DISCRETION OFO'BRIEN BROTHERS5'-3 1/4"5'-1 1/2"8'-7 3/4"JOB NO:DRAWN:PROJ MGR:CHECKED:ISSUE DATE:O'Brien Home Farm Single Family Uphill LotSouth Burlington, VermontA0.1A09/01/17FOUNDATION/ LOWER LEVELPLANBluebellKEYNOTES:FLOOR PLAN101 SINK W/ GARBAGE DISPOSAL.102 DISHWASHER.103 REFRIGERATOR.104 RANGE W/ HOOD/MICRO.107 PANTRY SHELVES PER BUILDER SPEC.108 BASE CABINETS.109 UPPER CABINETS.110 WATER CLOSET.111 LAV. SINK.113 SHOWER (SIZE PER PLAN).115 DROP IN TUB W/ PLATFORM.116 TUB/SHOWER (SIZE PER PLAN).117 LINEN SHELVES PER BUILDER SPEC.118 WASHER.119 DRYER.121 LINE OF SHELF ABOVE.122 ROD & SHELF.123 ATTIC ACCESS (22"x30" U.N.O.).124 HANDRAIL.125 SOLID CORE DOOR W/ SELF CLOSER.126 LINE OF OVERHEAD GARAGE DOOR INOPEN POSITION.127 PROVIDE 5/8" TYPE "X" GYPSUM BOARD INGARAGE AS REQUIRED BY CODE.128 SLOPE GARAGE FLOOR 1/8" PER FOOTTOWARD GARAGE DOOR OPENING.130 LINE OF SOFFIT ABOVE (REFER TOEXTERIOR ELEVATIONS FOR HEIGHTSAND DETAILS).132 LINE OF FRAMING ABOVE.133 LINE OF FRAMING BELOW.135 PREFABRICATED FIREPLACE, GAS(NON-WOOD BURNING) AS SPECIFIED BYBUILDER.137 42" HIGH EXTERIOR GUARDRAIL W/BALUSTERS TO BE SPACED SUCH THAT 4"SPHERE CANNOT PASS BETWEENBALUSTERS.138 2X6 HALF WALL @ 34 1/2" A.F.F. W/COUNTER139 2X4 LOW WALL 36" A.F.F.142 OPTIONAL PET SPACE 36" A.F.F.147 LINE OF DECK ABOVE.148 BEAM POCKET.150 TOILET PAPER HOLDER 19" MIN A.F.F.151 TOWEL BAR 48" A.F.F.152 TOWEL RING 48" A.F.F.SCALE:1/4" = 1'-0" (22x34)Foundation/ Partial FinishedWalkout PlanREVISIONS CONSTRUCTION ASSEMBLIES:T THE FOLLOWING KEYNOTES REFERENCE THE SYMBOLS AS SHOWN ON PLANSA. ROOF CONSTRUCTION:COMPOSITION ROOF SHINGLES ON UNDERLAYMENT ON ROOF SHEATHING ON ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD OVER MOISTURE VAPOR RETARDER WITH INSULATION ABOVE.B1. TYPICAL SIDING WALL CONSTRUCTION:SIDING ON WATER RESISTANT BARRIER ON EXTERIOR WALL SHEATHING ON 2x4 STUDS, 16" O.C. OR 2x6 STUDS, 24" O.C. W/ INSULATION IN CAVITIES.INTERIOR: 1/2" GYPSUM BOARD OVER MOISTURE VAPOR RETARDER.B2. TYPICAL STONE VENEER WALL CONSTRUCTION:ADHERED SYNTHETIC STONE VENEER (INSTALLED PER MFR'S SPECS.) OVER WATER RESISTANT BARRIER ON EXTERIOR WALL SHEATHING ON 2x4 STUDS, 16" O.C. OR 2x6 STUDS, 24" O.C. W/ INSULATION IN CAVITIES.INTERIOR: 1/2" GYPSUM BOARD OVER MOISTURE VAPOR RETARDER.C. TYPICAL FLOOR CONSTRUCTION:FINISHED FLOORING ON 3/4" FLOOR SHEATHING ON FLOOR FRAMING AS NOTED ON STRUCTURAL DRAWINGS.MAIN FLOOR CEILING: 1/2" GYPSUM BOARD.D. CONCRETE SLAB CONSTRUCTION:4" CONCRETE SLAB OVER 6 MIL. POLYETHYLENE VAPOR BARRIER OVER 4" MINIMUM GRANULAR FILL.9' - 0" CLGFamily9' - 0" CLGNook9' - 0" CLGKitchen9' - 0" CLGOwners Suite9' - 0" CLGOwners Bath9' - 0" CLGLaundry9' - 0" CLGBath 29' - 0" CLGW.I.C.9' - 0" CLGBedroom 29' - 0" CLGDiningDeckPorch9' - 0" CLGW.I.C.266820682668206821068210682106821068206821068306821068 PKT6068 French210683060 DH 3060 DH3060 DH3060 DH3060 DH2060 DH2060 DH2030 FX2030 FX3060 DH3060 DH 3060 DHFoyer15'-0"13'-4"5'-10" 5'-10" 7'-6" 7'-6" 6'-4" 7'-0"11'-10 1/2"25'-8"4'-0"25'-8"4'-0" 2'-0"42'-0"4'-0"11'-7 1/2" 6'-10 1/2" 4'-1"19'-5"2'-0"11'-4"7'-4" 11'-11"9'-5"3'-2" 5'-0" 3'-2" 4'-0" 3'-4" 6'-0" 5'-11" 2'-4" 4'-5" 2'-8"DN 15 RISERSDN AS REQ'D2A6.1A3A6.2A1A6.1A1A5.16010 TRN ABV.6010 TRN ABV.2'-0" 2'-0"27'-4"1'-8"8"4"5'-0 1/2"6'-11 1/2"4'-0"19'-5"6'-4 1/2"4'-7"11'-2"2'-0"2'-0"15'-11"3'-6"5'-3 1/2"1'-7 1/2"1'-7"4'-4 1/2"11'-3"22'-11 1/2"6'-3"2'-3"4'-5"5'-4"4'-4"8'-7" 3'-2 1/2" 4" 3'-2 1/2"9 1/2"2'-0" 3'-6" 3'-0" 5'-9 1/2" 5'-11" 3'-8"26'-0 1/2"13'-0 1/2"10110710810810910910910910810210310411011011111111111336"x48"1161171221221221171191181221221211231241301371391331088" 5'-4"6'-0" 4'-0"38'-0"11'-4"8'-0"20'-8"40'-0"2x6 WALL2x6 WALL2x6 WALL33"x60"11'-6" 3 1/2" 3'-8 1/2" 3'-4" 4'-2 1/2" 2'-4 1/2" 5'-0" 2'-0" 3'-11" 3'-8"8" 6'-8" 8"8" 3'-4"1'-4" 4'-0" 1'-4"15015215215115015210'-0"6'-1"9'-1 1/2"HOSE BIB6'-2 3/4"6'-2 3/4"3060 DH3060 DHGENERAL FLOOR PLAN NOTES:* ALL UNDIMENSIONED PARTITIONS ( ) ARE 3 1/2" ROUGH UNLESS NOTED OTHERWISE.* ALL EXTERIOR DIMENSIONS ARE TO FACE OF STUDS UNLESS NOTED OTHERWISE.* ALL ANGLED PARTITIONS ARE 45 DEGREES UNLESS NOTED OTHERWISE.* WINDOW SUPPLIER TO VERIFY AT LEAST ONE WINDOW IN ALL BEDROOMS MEETS ALL EMERGENCY EGRESS REQUIREMENTS.* ALL ELECTRICAL AND MECHANICAL EQUIPMENT, METER LOCATIONS, ETC. SHALL BE CONFIRMED BY MECHANICAL AND ELECTRICAL CONTRACTORS. CONTRACTORS SHALL COORDINATE WITH BUILDER PRIOR TO RELOCATION OF EQUIPMENT AND METERS.* ALL TRUSSES TO BEAR ON EXTERIOR WALLS AND/OR GIRDER TRUSS UNLESS NOTED OTHERWISE.* TRUSS MFG. TO SIZE MEMBERS, FASTENERS, HANGERS & SET SPACING FOR ALL TRUSSES.* FOR ADDITIONAL INFORMATION SEE GENERAL NOTES AND DETAILS.* TYPICAL WINDOW HEAD HEIGHTS SHALL BE 8'-0 7/8" A.F.F. (U.N.0.) W/ 9'-1 1/8" CLG. AND 7'-0 7/8" A.F.F (U.N.O.) W/ 8'-1 1/8" CLG.* PROVIDE BLOCKING FOR ALL GRABBARS IN BATH, SEE DETAILS.JOB NO:DRAWN:PROJ MGR:CHECKED:ISSUE DATE:O'Brien Home Farm Single Family Uphill LotSouth Burlington, VermontA1.1A09/01/17MAIN FLOOR PLANSCALE:1/4" = 1'-0" (22x34)Main Floor PlanBluebellKEYNOTES:FLOOR PLAN101 SINK W/ GARBAGE DISPOSAL.102 DISHWASHER.103 REFRIGERATOR.104 RANGE W/ HOOD/MICRO.107 PANTRY SHELVES PER BUILDER SPEC.108 BASE CABINETS.109 UPPER CABINETS.110 WATER CLOSET.111 LAV. SINK.113 SHOWER (SIZE PER PLAN).115 DROP IN TUB W/ PLATFORM.116 TUB/SHOWER (SIZE PER PLAN).117 LINEN SHELVES PER BUILDER SPEC.118 WASHER.119 DRYER.121 LINE OF SHELF ABOVE.122 ROD & SHELF.123 ATTIC ACCESS (22"x30" U.N.O.).124 HANDRAIL.125 SOLID CORE DOOR W/ SELF CLOSER.126 LINE OF OVERHEAD GARAGE DOOR INOPEN POSITION.127 PROVIDE 5/8" TYPE "X" GYPSUM BOARD INGARAGE AS REQUIRED BY CODE.128 SLOPE GARAGE FLOOR 1/8" PER FOOTTOWARD GARAGE DOOR OPENING.130 LINE OF SOFFIT ABOVE (REFER TOEXTERIOR ELEVATIONS FOR HEIGHTSAND DETAILS).132 LINE OF FRAMING ABOVE.133 LINE OF FRAMING BELOW.135 PREFABRICATED FIREPLACE, GAS(NON-WOOD BURNING) AS SPECIFIED BYBUILDER.137 42" HIGH EXTERIOR GUARDRAIL W/BALUSTERS TO BE SPACED SUCH THAT 4"SPHERE CANNOT PASS BETWEENBALUSTERS.138 2X6 HALF WALL @ 34 1/2" A.F.F. W/COUNTER139 2X4 LOW WALL 36" A.F.F.142 OPTIONAL PET SPACE 36" A.F.F.147 LINE OF DECK ABOVE.148 BEAM POCKET.150 TOILET PAPER HOLDER 19" MIN A.F.F.151 TOWEL BAR 48" A.F.F.152 TOWEL RING 48" A.F.F.REVISIONS CONSTRUCTION ASSEMBLIES:T THE FOLLOWING KEYNOTES REFERENCE THE SYMBOLS AS SHOWN ON PLANSA. ROOF CONSTRUCTION:COMPOSITION ROOF SHINGLES ON UNDERLAYMENT ON ROOF SHEATHING ON ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD OVER MOISTURE VAPOR RETARDER WITH INSULATION ABOVE.B1. TYPICAL SIDING WALL CONSTRUCTION:SIDING ON WATER RESISTANT BARRIER ON EXTERIOR WALL SHEATHING ON 2x4 STUDS, 16" O.C. OR 2x6 STUDS, 24" O.C. W/ INSULATION IN CAVITIES.INTERIOR: 1/2" GYPSUM BOARD OVER MOISTURE VAPOR RETARDER.B2. TYPICAL STONE VENEER WALL CONSTRUCTION:ADHERED SYNTHETIC STONE VENEER (INSTALLED PER MFR'S SPECS.) OVER WATER RESISTANT BARRIER ON EXTERIOR WALL SHEATHING ON 2x4 STUDS, 16" O.C. OR 2x6 STUDS, 24" O.C. W/ INSULATION IN CAVITIES.INTERIOR: 1/2" GYPSUM BOARD OVER MOISTURE VAPOR RETARDER.C. TYPICAL FLOOR CONSTRUCTION:FINISHED FLOORING ON 3/4" FLOOR SHEATHING ON FLOOR FRAMING AS NOTED ON STRUCTURAL DRAWINGS.MAIN FLOOR CEILING: 1/2" GYPSUM BOARD.D. CONCRETE SLAB CONSTRUCTION:4" CONCRETE SLAB OVER 6 MIL. POLYETHYLENE VAPOR BARRIER OVER 4" MINIMUM GRANULAR FILL.BASEMENT FLOORT.O.F.MAIN FLOORMAIN PLATE9'-1 1/8"11 1/2"8'-8"PORCH PLATE APORCH STOOP8'-10"4'-8"10" 12"10" 12"2032237'-7 3/4"4AD.210AD.28AD.2215201AD.333AD.16AD.22132072162052232112102154" / 12"6" / 12"6" / 12"6" / 12"6" / 12"6" / 12"10" / 12"10" / 12"1'-0"1'-0"RAKETYP.EAVETYP.BASEMENT FLOORT.O.F.MAIN FLOORMAIN PLATE8'-8" 11 1/2" 9'-1 1/8"6" 12"6" 12"2032232109AD.25AD.21AD.23AD.12232118AD.2201BASEMENT FLOORT.O.F.MAIN FLOORMAIN PLATE9'-1 1/8"11 1/2"8'-8"PORCH PLATE APORCH STOOP8'-10"4'-8"4" 12"7'-7 3/4"2232112102012032058AD.23AD.19AD.21AD.26" 12"6" 12"2154'-8"23'-2 15/16"BASEMENT FLOORT.O.F.MAIN FLOORMAIN PLATEPORCH PLATE APORCH STOOP8'-10"4'-8"4" 12"8'-8" 11 1/2" 9'-1 1/8"2157'-7 3/4"2012232112052033AD.15AD.28AD.26AD.29AD.26" 12"6" 12"4'-8"17'-0 7/16"GENERAL EXTERIOR ELEVATION NOTES:* GRADE CONDITIONS MAY VARY FOR INDIVIDUAL SITE FROM THAT SHOWN.* PROVIDE ROOF AND SOFFIT VENTS AS SPECIFIED BY BUILDER.* PROVIDE GUTTERS AND DOWNSPOUTS AS SPECIFIED BY BUILDER.JOB NO:DRAWN:PROJ MGR:CHECKED:ISSUE DATE:O'Brien Home Farm Single Family Uphill LotSouth Burlington, VermontA3.1A09/01/17EXTERIOR ELEVATIONS &ROOF PLAN-ASCALE:1/4" = 1'-0" (22x34)Front ElevationSCALE:1/8" = 1'-0" (22x34)Roof PlanSCALE:1/8" = 1'-0" (22x34)Rear ElevationSCALE:1/8" = 1'-0" (22x34)Right ElevationSCALE:1/8" = 1'-0" (22x34)Left ElevationElevation - FarmhouseBluebellKEYNOTES:EXTERIOR ELEVATION201 ROOFING PER BUILDER SPEC.203 6" LAP SIDING.204 SHAKE SIDING.205 BOARD & BATTEN SIDING.207 PANEL SIDING.210 ALUMINUM WRAPPED 2x8 FASCIA.211 ALUMINUM WRAPPED 2x8 RAKE.212 5/4x2 TRIM.213 5/4x4 TRIM.214 5/4x6 TRIM.215 5/4x8 TRIM.216 5/4x10 TRIM.221 18"x72" SHUTTERS223 5/4x6 FRIEZE TRIM.NOTE:* REQUIRED NET FREE VENTED AREAS ARE CALCULATED BY MULTIPLYING THE ACTUAL ATTIC AREA (SQ FT) IN COLUMN 1BY 1/300 AND MULTIPLYING SUM BY 144 SQ IN/SQ FT 40%-50% OF TOTAL NET FREE VENTED AREA IS REQUIRED AT THERIDGE (HIGH) AND THE REMAINING IS THE REQUIRED IN THE SOFFIT (LOW). WHEN NO "HIGH/LOW" VENTING IS PROVIDED,THE REQUIRED NET FREE AREA IS 1/150 OF THE ACTUAL AREA AND 100% OF THIS VENTED AREA SHALL BE PROVIDED ATTHE SOFFIT.** ACTUAL NET FREE VENTED SOFFIT AREAS ARE CALCULATED BY DIVIDING THE REQUIRED NET FREE VENTED SOFFITAREA (FT) BY THE MANUFACTURERS STATED ACTUAL VENTED NET FREE AREA PER VENT. WHEN APPLICABLE, THE ACTUALTOTAL NUMBER OF SOFFIT VENTS SHALL BE DIVIDED EQUALLY BETWEEN EACH EAVE AND SPACED AN EQUAL DISTANCEAPART FROM ONE ANOTHER.ACTUAL NET FREE VENTED RIDGE AREAS ARE CALCULATED BY DIVIDING THE REQUIRED NET FREE VENTED RIDGE AREA...ATTIC VENTILATION SCHEDULE (ELEVATION A)Name AreaTOTAL NETVENTED(1/300) (SQ IN)TOTAL NETVENTED(1/150) (SQ IN)*LOWER VENTMIN (50%)*LOWER VENTMAX (60%)*UPPER VENTMIN (40%)*UPPER VENTMAX (50%)MAIN ROOF 1719 SF 825 in² 1650 in² 412 in² 495 in² 330 in² 412 in²LOWER ROOF 47 SF 22 in² 45 in² 11 in² 13 in² 9 in² 11 in²REVISIONS CONSTRUCTION ASSEMBLIES:T THE FOLLOWING KEYNOTES REFERENCE THE SYMBOLS AS SHOWN ON PLANSA. ROOF CONSTRUCTION:COMPOSITION ROOF SHINGLES ON UNDERLAYMENT ON ROOF SHEATHING ON ROOF FRAMING MEMBERS (AS NOTED ON FRAMING PLANS). CEILING: 5/8" GYPSUM BOARD OVER MOISTURE VAPOR RETARDER WITH INSULATION ABOVE.B1. TYPICAL SIDING WALL CONSTRUCTION:SIDING ON WATER RESISTANT BARRIER ON EXTERIOR WALL SHEATHING ON 2x4 STUDS, 16" O.C. OR 2x6 STUDS, 24" O.C. W/ INSULATION IN CAVITIES.INTERIOR: 1/2" GYPSUM BOARD OVER MOISTURE VAPOR RETARDER.B2. TYPICAL STONE VENEER WALL CONSTRUCTION:ADHERED SYNTHETIC STONE VENEER (INSTALLED PER MFR'S SPECS.) OVER WATER RESISTANT BARRIER ON EXTERIOR WALL SHEATHING ON 2x4 STUDS, 16" O.C. OR 2x6 STUDS, 24" O.C. W/ INSULATION IN CAVITIES.INTERIOR: 1/2" GYPSUM BOARD OVER MOISTURE VAPOR RETARDER.C. TYPICAL FLOOR CONSTRUCTION:FINISHED FLOORING ON 3/4" FLOOR SHEATHING ON FLOOR FRAMING AS NOTED ON STRUCTURAL DRAWINGS.MAIN FLOOR CEILING: 1/2" GYPSUM BOARD.D. CONCRETE SLAB CONSTRUCTION:4" CONCRETE SLAB OVER 6 MIL. POLYETHYLENE VAPOR BARRIER OVER 4" MINIMUM GRANULAR FILL.9' - 0" CLGStudy5068 Glass French9' - 0" CLGOwners Bath8' - 0" CLGW.I.C.4040 FX6'-9" 6'-6" 6'-9 1/2" 2'-6 1/2"2106821068 PKT21068TEMP12212211011711311542"x42"2'-0" 3'-7 1/2" 3'-11 1/2"6'-9" 2'-0 1/2" 7'-8 1/2" 6'-1"WPWP1509' - 0" CLGFamily7'-0" 6'-8 1/4"13'-0 1/2" 1'-11 1/2"135BASEMENT PLAN NOTES:* SEE BASEMENT PLAN SHEETS FOR ADDITIONAL INFORMATIONFLOOR PLAN NOTES:* SEE FLOOR PLAN SHEETS FOR ADDITIONAL INFORMATIONELECTRICAL NOTES :* SEE ELECTRICAL PLAN SHEETS FOR ADDITIONAL INFORMATIONELEVATION NOTES :* SEE ELEVATION SHEETS FOR ADDITIONAL INFORMATIONFoyer12'-4"1'-8"8"4'-0"8'-7" 3'-2 1/2" 4"4'-0"2'-4 1/2"11'-0 1/2"11'-10 1/2"3'-5"JOB NO:DRAWN:PROJ MGR:CHECKED:ISSUE DATE:O'Brien Home Farm Single Family Uphill LotSouth Burlington, VermontA4.2.109/01/17OPT. FLOOR PLANSSCALE:1/4" = 1'-0" (22x34)Opt StudyPartial Main Floor PlanSCALE:1/4" = 1'-0" (22x34)Opt Owners BathPartial Main Floor PlanPlan OptionsBluebellSCALE:1/4" = 1'-0" (22x34)Opt FireplacePartial Main Floor PlanSCALE:1/4" = 1'-0" (22x34)Opt BedroomPartial Main Floor PlanREVISIONS 433434DFURNWP/GFISDTO LIGHTABOVECOWP/GFIWP/GFITVPHOTOCELLCERAMICCERAMICCERAMICCERAMICFLUSHFLUSHFLUSH6" LED SURFACECERAMICCERAMICCERAMICPLEASE WIRE ALL PHOTOCELLS FOR FRONT EXTERIOR LIGHTS TO RUN ONPHOTOCELL WHEN LIGHT SWITCH IS TURNED ON. HAVE LIGHT SWITCHOVERRIDE PHOTOCELL WHEN SWITCH IS TURNED OFF.ELECTRICAL KEY:SINGLE POLE OUTLETDUPLEX CONVENIENCE OUTLETDUPLEX OUTLET ABOVE COUNTERWEATHERPROOF DUPLEX OUTLETWPGFIGROUND-FAULT CIRCUIT-INTERRUPTER DUPLEX OUTLETHALF-SWITCHED DUPLEX OUTLETSPECIAL POURPOSE OUTLET/JUNCTION BOXUSB CHARGER/TAMPER-RESISTANT DUPLEX OUTLETUSBDUPLEX OUTLET IN FLOOR220 VOLT OUTLET220VOVERHEAD DUPLEXWALL SWITCHTHREE-WAY SWITCHFOUR-WAY SWITCHDIMMER SWITCHREINFORCED JUNCTION BOXCEILING MOUNTED LIGHT FIXTUREWALL MOUNTED LIGHT FIXTURERECESSED LIGHT FIXTURERECESSED LIGHT FIXTURE (WEATHERPROOF)WPRECESSED FLOURESCENT LIGHT FIXTURE (WEATHERPROOF)FLURRECESSED LIGHT FIXTURE (VAPOR-PROOF)VPRECESSED FLOURESCENT LIGHT FIXTURE (VAPOR-PROOF)VP/FLURPNDTCEILING MOUNTED PENDANT LIGHT FIXTUREMINICEILING MOUNTED MINI-PENDANT LIGHT FIXTURELEDCEILING MOUNTED LED LIGHT FIXTUREWALL MOUNTED LED LIGHT FIXTURELEDRECESSED LED LIGHT FIXTURELEDRECESSED ADJUSTABLE EYEBALL LED LIGHT FIXTUREEBPCLED LIGHT FIXTURE WITH PULL CHAINFLUORESCENT LIGHT FIXTUREFLUORESCENT LIGHT FIXTURE WITH PULL CHAINPCEXHAUST FAN (VENT TO EXIT)EXHAUST FAN/LIGHT COMBINATION (VENT TO EXIT)EXHAUST FAN WITH HEAT LAMP (VENT TO EXIT)CHIMESPUSH BUTTON SWITCHSDHDSMOKE DETECTORCOCO DETECTORHEAT DETECTORTHERMOSTATTSSPEAKER (PROVIDE ADEQUATE SUPPORT)TVTELEVISIONMELECTRIC METERELECTRIC PANELTELEPHONECOMPUTERCEILING FAN WITH LED LIGHT FIXTURE (PROVIDE ADEQUATE SUPPORT)ELECTRICAL NOTES:* PROVIDE AND INSTALL LOCALLY CERTIFIED SMOKE DETECTORS AS REQUIRED BY NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) AND MEETING THE REQUIREMENTS OF ALL GOVERNING CODES* PROVIDE AND INSTALL GROUND FAULT CIRCUIT-INTERRUPTERS (GFI) AS REQUIRED BY NATIONAL ELECTRIC CODE (NEC) AND MEETING THE REQUIREMENTS OF ALL GOVERNING CODES.* ELECTRICAL CONTRACTOR TO PROVIDE REQUIRED DIRECT HOOK-UPS/CUTOFFS.* HVAC CONTRACTOR TO VERIFY THERMOSTAT LOCATIONS.* ALL ELECTRICAL AND MECHANICAL EQUIPMENT (I.E. FURNACES, A/C UNITS, ELECTRICAL PANELS, SANITARY SUMP PITS, DRAIN TILE SUMP, AND WATER HEATERS) ARE SUBJECT TO RELOCATION DUE TO FIELD CONDITIONS.* ALL BRANCH CIRCUITS THAT SUPPLY 125 VOLT 15 & 20 AMP RECEPTACLE OUTLETS INSTALLED IN ANY HABITAL SPACE SHALL BE PROTECTED BY AN ARC FAULT CIRCUIT INTERRUPTER PER N.E.C. 210-12(A) & (B).ELECTRICAL DEVICES:ABOVE FINISHED FLOOR:SWITCHES OVER COUNTER.................. 48" TO CLWALL OUTLETS OVER COUNTER..........48" TO CLREMAINING SWITCHES...........................48" TO CLWALL OUTLETS........................................ 12" TO CLBATH VANITY BRACKET OUT(1" ABOVE TOP OF MIRROR)............80" TO CLWATER SOFTENER AND SUMP OUTLETS........................................48" TO CLTELEPHONE OUTLETS............................12" TO CLTELEVISION OUTLETS.............................12" TO CLEXTERIOR GFI OUTLETS.........................12" TO CLGARAGE GFI (ABOVE GARAGE FLOOR)12" TO CLBASEMENT WALL OUTLETS...................48" TO CLFRONT DOOR COACH LIGHT..................72" TO CLGARAGE DOOR COACH LIGHT(ABOVE GARAGE FLOOR).......................84" TO CLDINING AND BREAKFAST FIXTURE........64" TO BOTTOMOF FIXTUREFOYER AND STAIRWAY FIXTURE.......... 96" TO BOTTOMOF FIXTURETHERMOSTAT...........................................54" TO CLDOORBELL CHIMES.................................84" TO CLDOORBELL BUTTON................................LEVEL W/DOOR HANDLEKITCHEN HOOD FAN "WHIP"...................66" TO CLKITCHEN WALL HUNGMICROWAVE OUTLET..............................76" TO CLKITCHEN DISHWASHER RECEPTACLE.UNDER SINKKITCHEN RANGE......................................24" TO CLKITCHEN REFRIGERATOR......................48" TO CLWASHER/DRYER OUTLET...................... 48" TO CLCL = CENTERLINE1 = FIELD VERIFY2 = MASTER BATH STANDARD 30" HIGHVANITY TO BE RAISED 4"1,2JOB NO:DRAWN:PROJ MGR:CHECKED:ISSUE DATE:O'Brien Home Farm Single Family Uphill LotSouth Burlington, VermontE0.1A09/01/17WALKOUT ELECTRICALPLAN-AElevation - ABluebellSCALE:1/4" = 1'-0" (22x34)Walkout Electrical PlanREVISIONS 34D33333333334ELECTRICAL KEY:SINGLE POLE OUTLETDUPLEX CONVENIENCE OUTLETDUPLEX OUTLET ABOVE COUNTERWEATHERPROOF DUPLEX OUTLETWPGFIGROUND-FAULT CIRCUIT-INTERRUPTER DUPLEX OUTLETHALF-SWITCHED DUPLEX OUTLETSPECIAL POURPOSE OUTLET/JUNCTION BOXUSB CHARGER/TAMPER-RESISTANT DUPLEX OUTLETUSBDUPLEX OUTLET IN FLOOR220 VOLT OUTLET220VOVERHEAD DUPLEXWALL SWITCHTHREE-WAY SWITCHFOUR-WAY SWITCHDIMMER SWITCHREINFORCED JUNCTION BOXCEILING MOUNTED LIGHT FIXTUREWALL MOUNTED LIGHT FIXTURERECESSED LIGHT FIXTURERECESSED LIGHT FIXTURE (WEATHERPROOF)WPRECESSED FLOURESCENT LIGHT FIXTURE (WEATHERPROOF)FLURRECESSED LIGHT FIXTURE (VAPOR-PROOF)VPRECESSED FLOURESCENT LIGHT FIXTURE (VAPOR-PROOF)VP/FLURPNDTCEILING MOUNTED PENDANT LIGHT FIXTUREMINICEILING MOUNTED MINI-PENDANT LIGHT FIXTURELEDCEILING MOUNTED LED LIGHT FIXTUREWALL MOUNTED LED LIGHT FIXTURELEDRECESSED LED LIGHT FIXTURELEDRECESSED ADJUSTABLE EYEBALL LED LIGHT FIXTUREEBPCLED LIGHT FIXTURE WITH PULL CHAINFLUORESCENT LIGHT FIXTUREFLUORESCENT LIGHT FIXTURE WITH PULL CHAINPCEXHAUST FAN (VENT TO EXIT)EXHAUST FAN/LIGHT COMBINATION (VENT TO EXIT)EXHAUST FAN WITH HEAT LAMP (VENT TO EXIT)CHIMESPUSH BUTTON SWITCHSDHDSMOKE DETECTORCOCO DETECTORHEAT DETECTORTHERMOSTATTSSPEAKER (PROVIDE ADEQUATE SUPPORT)TVTELEVISIONMELECTRIC METERELECTRIC PANELTELEPHONECOMPUTERCEILING FAN WITH LED LIGHT FIXTURE (PROVIDE ADEQUATE SUPPORT)ELECTRICAL NOTES:* PROVIDE AND INSTALL LOCALLY CERTIFIED SMOKE DETECTORS AS REQUIRED BY NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) AND MEETING THE REQUIREMENTS OF ALL GOVERNING CODES* PROVIDE AND INSTALL GROUND FAULT CIRCUIT-INTERRUPTERS (GFI) AS REQUIRED BY NATIONAL ELECTRIC CODE (NEC) AND MEETING THE REQUIREMENTS OF ALL GOVERNING CODES.* ELECTRICAL CONTRACTOR TO PROVIDE REQUIRED DIRECT HOOK-UPS/CUTOFFS.* HVAC CONTRACTOR TO VERIFY THERMOSTAT LOCATIONS.* ALL ELECTRICAL AND MECHANICAL EQUIPMENT (I.E. FURNACES, A/C UNITS, ELECTRICAL PANELS, SANITARY SUMP PITS, DRAIN TILE SUMP, AND WATER HEATERS) ARE SUBJECT TO RELOCATION DUE TO FIELD CONDITIONS.* ALL BRANCH CIRCUITS THAT SUPPLY 125 VOLT 15 & 20 AMP RECEPTACLE OUTLETS INSTALLED IN ANY HABITAL SPACE SHALL BE PROTECTED BY AN ARC FAULT CIRCUIT INTERRUPTER PER N.E.C. 210-12(A) & (B).ELECTRICAL DEVICES:ABOVE FINISHED FLOOR:SWITCHES OVER COUNTER.................. 48" TO CLWALL OUTLETS OVER COUNTER..........48" TO CLREMAINING SWITCHES...........................48" TO CLWALL OUTLETS........................................ 12" TO CLBATH VANITY BRACKET OUT(1" ABOVE TOP OF MIRROR)............80" TO CLWATER SOFTENER AND SUMP OUTLETS........................................48" TO CLTELEPHONE OUTLETS............................12" TO CLTELEVISION OUTLETS.............................12" TO CLEXTERIOR GFI OUTLETS.........................12" TO CLGARAGE GFI (ABOVE GARAGE FLOOR)12" TO CLBASEMENT WALL OUTLETS...................48" TO CLFRONT DOOR COACH LIGHT..................72" TO CLGARAGE DOOR COACH LIGHT(ABOVE GARAGE FLOOR).......................84" TO CLDINING AND BREAKFAST FIXTURE........64" TO BOTTOMOF FIXTUREFOYER AND STAIRWAY FIXTURE.......... 96" TO BOTTOMOF FIXTURETHERMOSTAT...........................................54" TO CLDOORBELL CHIMES.................................84" TO CLDOORBELL BUTTON................................LEVEL W/DOOR HANDLEKITCHEN HOOD FAN "WHIP"...................66" TO CLKITCHEN WALL HUNGMICROWAVE OUTLET..............................76" TO CLKITCHEN DISHWASHER RECEPTACLE.UNDER SINKKITCHEN RANGE......................................24" TO CLKITCHEN REFRIGERATOR......................48" TO CLWASHER/DRYER OUTLET...................... 48" TO CLCL = CENTERLINE1 = FIELD VERIFY2 = MASTER BATH STANDARD 30" HIGHVANITY TO BE RAISED 4"1,2GFIGFI220V GFIGFIGFIGFIGFIGFIGFI220VWP/GFIGFIWP/GFISDSDSDSDCOCOCHANDELIERFLUSHMICROOUTLETTO SWITCHBELOWTVTVSEMI-FLUSHFLUSHFLUSHFLUSHFLUSHFLUSHFLUSHFLUSH2 HEAD VANITY LIGHTLED EXHAUST FAN/LIGHTLED EXHAUST FAN/LIGHT3 HEAD VANITY LIGHT3 HEAD VANITY LIGHTLED EXHAUST FAN/LIGHT6" LED SURFACE LIGHT6" LED SURFACE LIGHT6" LED SURFACE LIGHT6" LED SURFACE LIGHT6" LED SURFACE LIGHTTV6" LED SURFACE LIGHTFLUSHJOB NO:DRAWN:PROJ MGR:CHECKED:ISSUE DATE:O'Brien Home Farm Single Family Uphill LotSouth Burlington, VermontE1.1A09/01/17MAIN FLOOR ELECTRICALPLAN-ABluebellSCALE:1/4" = 1'-0" (22x34)Main Floor Electrical PlanREVISIONS