CITY OF SOUTH BURLINGTON
ZONING PERMIT APPLICATION
Applicant: UVM Medical Center Application No: 1 �'— 3 S 5
g Applicant Mailing Address:
199 Main Street Suite 150, Burlington VT 05401 [office use only]
Applicant Email:
Property Street Address: 40 IDX Drive, South Burlington, VT 05403
Property owner: North River NC IDX
Daytime phone:
Parcel Size:
Property Owner Mailing Address: 224 12th Avenue, New York, NY 10001 Tax Parcel ID No.
VT 06403
1. PROPOSED project Including building dimensions (describe): Installation of new computer room air
conditioner and exterior mounted air cooled condensing unit on a concrete pad.
/ 2. Present USE(S) of the property:
❑Single family home on Its own parcel
121 Other (please state the USE per Land Development Regulations- retail, general office, multifamily residential, etc.):
General Office
3. List all present structure(s) on property (describe including dimensions or square footage of each):
4. Does the project Include a proposed change of USE?
V No (the property will still be used for the same purpose)
❑Yes (please state proposed changed or added USES per Land Development Regulations- retail, general
office, multifamily residential, etc.):
S. ESTIMATED total cost of Improvements (materials and labor): $ 85,000
6. Building footprint — Le. size In sq.ft of main floor of house and all attached and detached structures Including enclosed
breezeways, garages, and sheds (describe): Existing: N/A Proposed: N/A
7. Total square feet of other Impervious surfaces on site (i.e. driveways, patios, decks)
Existing: Proposed: 15 sf concrete pad
8. ATTACH SKETCH PLAN OR SITE PLAN (not required If project consists ONLY of interior renovations or replacement of
existing roof, siding, etc. In the exact same size)
I
4. APPLICANT/OWNER CERTIFICATION
K
The undersigned prope r hereby consents to submit this application and understands that if the application is approved, the
Zoning Permit attaKed conditions will be binding on the property.
Prop wrier Sign PRINT NAME Date
The undersigned applicant hereby affirms that the Information presented in this application is true, accurate and complete.
AppllcadSlgnWre PRINf NAME Date
OFFICE USE ONLY - ADMINISTRATIVE OFFICER ACTION - OFFICE USE ONLY
DATE Received: qb(?(2Q(g FEE Received: $ Identification of zoning district: C2-
Identification of proposed use: _ \ !1 f e-
PROPOSED USE TYPE: Permitted =Conditions.
Date of SITE PLAN approvalldenial
Approval Date
Date of SUBDIVISION approval/ denial
Approval Date
Date of CONDITIONAL USE approval/ denial
Approval Date
Date of appeal VARIANCE approval/ denial
Approval Date
Date of MISCELLANEOUS approval/ denial
Denial Dale
Denial Date
Denial Date
Denial Date
Approval Date Denial Date
Provided applicant copy of URBEC or VCBE Standards Handbook orgNNot Applicable
FINAL ADMINISTRATIVE OFFICER ACTION
Z0NJ-,G/P/ERMIT
APPROVED �t7
Approval Date Administrative Officer's Signature O
Permit EFFECTIVE date Permit EXPIRATION date l�to��6Q
DENIED
Denial Date
REASON for DENIAL
Notice of Appeal Rights: Any Interested person may appeal this decision by filing a written Notice of Appeal with the clerk of the
Development Review Board within fifteen [151 days of the date of this decision. The notice of appeal must be accompanied by a filing
fee of $223.00.
This permit does NOT authorize commencement of any development activity approved by the permit until the permit takes
effect as set forth above. Site modifications and improvements made prior to this permit becoming effective may be subject to removal
and site restoration if a timely appeal is commenced.
NOTE: The applicant or permittee retains the obligation to Identify, apply for, and obtain relevant state permits for this project. Call (802)
879-5676 to speak with the regional Permit Specialist
No Text
R s
s
t.�
'
) l 1',
d
1
r
�
x
•
•
1
•
err
I I
I '�C.h1ERki0R I
I Erdr,LosurE I
I I
I I
I I
I I
I I
F--------- 1
I I
I I
L — — — —
PROVIDE ALLOWANCE TO
MODIFY RAISED FLOOR TO
ACCOMMODATE A/C UNIT,
CORD. WITH MECHANICAL
CONSTRUCT FRAMED
BELOW FLOOR,
-1
NORTH WALL: EXISTING GYP.
BOARD WALL BELOW FLOOR, SEAL
PENETRATIONS WITH ACOUSTICAL
SEALANT, TYP.
TEST I..A B.
[. 5_I
SOUTH WALL: EXISTING GYI
BOARD WALL BELOW FL001
SEAL PENETRATIONS WITH
ACOUSTICAL SEALANT, TYP.
FRAMED WALL BELOW
4LL GYP. BOARD AND
ZAnONS WITH
SEALANT, TYP.
`��rrrr BELOW FLOOR WORK
---------------------
I I
GINERATOR
Erac.osuRr
I I
I I
I
/— PROPOSED A/C UNIT
I I
I I J
III
a
cRac-1
I!
I I 5E I L --�—
liOLTUNE OF WALL ABOVE
I I SOUTH WALL PARTIAL NO WALL
EXISING SERVER ABOVE CEILING, INSTALL GYP. BOARD �\
- - CABINETS, TYP. WALL, SEAL ALL PENETRATIONS WITH
! THERE IS NO WALL BELOW WALL, SAL SEALANT, TYP.
RAISED FLOOR BEYOND - _ _ _ _ _ _ __ ABOVE CEILING WALL -- —^--
-, / THIS POINT I� 1 f ����-1 ENDS AT THIS POINT
iL•( I I ! I
I 1 I I
fESTLAB
SOUTH -- --.FRUIED WAL
I CEIUNG,I INSTALL GYP. BOARD, SEAL
PEN TIONS WBH ACO STICAL
SEALA TYP: - -
I I I I
"FRAMED W -ABOVE- - -�
COUNG,LL GYP. BD ANDiIONSWITTTIII��( ACOUSTICAL I \ TEMPORARILY REMOVE DOOR
(SEAL G4%-ABOVE -- - -� FRAME TO ALLOW FOR A/C
STEEL B.. WITH BATi. NSULATION) I UNIT RE- INSTALL, PATCH AND
NT
PANEL ILP! WEST WALL: LWALL ABOVE CEILING HAS tAr Ll. TtP1
SEVERAL OPENINGS, INST L GYP.-
r _. -BOARd A3 QUIRED TO OSE- - --
EXISTING OPENINGS. PEN Al'Rq ONS WTIH —
PANEL TLP? ACOUSTICAL EALANi, TYP. I [X SLING
[ IST uc L xi'mp_, — _ -.. L snua.. uP2 YI SnNG COMPUTER ROOM
__
2 ABOVE FLOOR & ABOVE CEILING WORK
SCALE: i/4"=1'-0"
/— EXISITNG TREE
PROPOSED CONDENSING UNIT,
MOUNTED ON A 72" X 36"
CONCRETE PAD
.. I EXIST.
V OONDENkR , L1 'I .
PROGRESS
mm
N�
SCALE IN FEET
0 1 2 4 8
w
------
I I
I I
I :F3Jl.F/i: T''R I
f-.id('-i.000Rf. I
I I
r,-1 BELOW FLOOR WORK
I SCALE: i/4"=7'-0"
`` , rrABOVE FLOOR & ABOVE CEILING WORK
LOCATION OF APPROX. LOCATION
10 TON A/C UNITNIT OF OUTDOOR AIR
CONDENSER DN
rvll
1
YlL
O O — --
LL
I q
� WMMC R ROOM ❑
APPROX LOCATION OF
PANEL DPH IN ELECTRIC
I � ROOM 1259
3 LOCATOR PLAN N•
SCALE: i/i6"=7'-0"
KEYED NOTES: O
1. RELOCATE DISCONNECT FOR EXISTING
CONDENSING UNIT, EXTEND CIRCUIT AS REO'D.
2. HOME RUN TO EXISTING POWER PANEL WE IN
ROOM 1259, FURNISH NEW 3 POLE CIRCUIT
BREWER TO MEET CONDENSER REQUIREMENTS,
FEEDER WIRE SIZE PER CODE.
3. HOME RUN TO EXISTING POWER PANEL DP_N IN
ROOM 1259, FURNISH NEW 3 POLE CIRCUIT
BREAKER TO MEET CRAC-1 REQUIREMENTS,
FEEDER WIRE SIZE PER CODE.
4. INSTALL DUPLEX RECEPTACLE BELOW FLOOR FOR
CONDENSATE PUMP. WIRE TO NEAREST 120V
RECEPTACLE CIRCUIT, 2#12,11120
5. INSTALL DUCT SMOKE DETECTOR, TIE INTO EXISING
FIRE HARM SYSTEM AS REO'D. COORDINATE
LOCATION OF DETECTOR AND TEST SWITCH WITH
MECHANICPL.
6. INSTALL 2 PORT DATA OUTLET. RUN (2) CAT 6
CABLES RACK TOO UVMMC PATCH PANEL IN CAGED
IT ROOM IN ADJACENT ROOM. COORD. WITH UVMMC
I.S. DEPT.
7. REMOVE EXISIRJG 2X4 LIGHT FIXTURES. INSTALL
(6) 2X2 LID U,'HT FIXTURES, MATCH EXISTING.
WIRE TO EXISTING CIRCUIT AND CONTINUE THE
SAME ROW PATTERN AS EXISTING LIGHTS.
N W
SCALE IN FEET ��11WJJ
0 1 2 4 8
r---------------------
| mC1.01"UR F---
BELOW FLOOR MECHANICAL WORK
____________________
(�Euomm, `
/ ENcmnURc /
REFRIGERANT PIPING, IW 79"x34' R/A DUCT UP TO PUMPED CONDENSATE DN��CEILING PLENUM ---\ UNDERFLOOR PLENUM
REFRIGEXTERIORERANT PIPING DN
5/81�8* SUCTION
EXISING SERVER
LAY -IN EGG CRATE
GRILLES
AC
17645
NEW GIN &
CONDENSATE TO EXISTING
SERVICES IN THIS AREA
ABOVE FLOOR & ABOVE CEILING MECHANICAL WORK
RELOCATE EXISTING
CONDENSING UNIT, REWORK
REFRIGERANT PIPING