Loading...
HomeMy WebLinkAboutAgenda 09_SP-21-01_20 Gregory Dr_The Granite Group#SP‐21‐01  Staff Comments  1  CITY OF SOUTH BURLINGTON  DEVELOPMENT REVIEW BOARD  SP‐21‐01_20 Gregory Dr_The Granite Group_2021‐01‐ 20.docx  DEPARTMENT OF PLANNING & ZONING   Report preparation date: January 13, 2021  Application received:  December 8, 2020  20 Gregory Drive  Site Plan Application #SP‐21‐001  Meeting date: January 20, 2021  Owner  20 Gregory Dr South Burlington VT LLC  6 Storrs St  Concord, NH 03301  Applicant  The Granite Group  20 Gregory Drive  South Burlington, VT 05403  Property Information  Tax Parcel ID  0740‐00020  Mixed Industrial & Commercial Zoning District    Engineer  Apex Engineering, LLC  1006 Decker Road  Georgia, VT 05468  Location Map          #SP‐21‐01  Staff Comments  2  PROJECT DESCRPTION  Site plan application #SP‐21‐01 of The Granite Group to amend a previously approved plan for a 16,272  sq. ft. wholesale use building.  The amendment consists of expanding the fenced outdoor storage area,  20 Gregory Drive.    PERMIT HISTORY  The Project is located in mixed industrial commercial zoning district.  It is located just west of Muddy  Brook and the Town of Williston.  It most recently received site plan approval #SP‐17‐57 to add the  existing outdoor storage area and minor related site improvements.  There have been no other  development review applications for the property since it’s initial approval for construction in 1989.    COMMENTS  Planning Director Paul Conner and Development Review Planner Marla Keene (“Staff”) have reviewed  the plans submitted on 12/8/2020 and offer the following comments. Numbered items for the Board’s  attention are in red.    CONTEXT  Outdoor storage is only allowed in non‐residential districts upon approval of the DRB in conjunction with  a site plan, conditional use and/or PUD application (see LDR 13.05).  The applicant has accordingly  submitted an application for site plan review.    As part of the proposed outdoor storage expansion, the applicant is proposing 1,520 sf of permanent  wetland buffer impacts and 3,100 sf of temporary wetland buffer impacts.  Wetland buffer impacts are  addressed in 12.02.  Finally, the property is included in a stormwater management permit which encompasses the majority  of the Gregory Drive business park.  The applicant is proposing to minimize the addition of impervious  surfaces to avoid the need to amend their permit and provide stormwater treatment and control for the  proposed expansion.  Stormwater management standards are addressed in LDR 12.03.  Staff considers the general concept of the project to be generally consistent with the purpose and  details of the land development regulations, but there are potential issues related to wetland impacts  and stormwater management, described below.         #SP‐21‐01  Staff Comments  3  B) ZONING DISTRICT & DIMENSIONAL REQUIREMENTS  Setbacks, Coverages & Lot Dimensions  No new building is proposed.  AIR and AIR‐I District Required Proposed  Min. Lot Size 40,000 sf  119,354 sf  Max. Building Coverage 40%  13.6%, no change  Max. Overall Coverage 70%  29.4%  Max. Front Setback Coverage 30%  15.4%, no change  Min. Front Setback 30 ft  45 ft, no change  Min. Side Setback 10 ft.  30 ft, no change  Min. Rear Setback 30 ft.  184 ft.  Height, flat roof 40 ft.  40 ft., no change   zoning compliance    C) 12.02 WETLAND PROTECTION  As noted above, there is an existing Class III wetland and associated 50‐foot wetland buffer located on the  site.  The applicant notes on their plan “The Class Three wetland depicted is not the result of an onsite  wetland delineation.  The location is based upon field observations and information obtained from the  Vermont Wetlands Department, including notes from a 2016 visit to the site by Tina Heath, Chittenden  County District Wetlands Ecologist.”  Based on the assumed wetland boundary, the applicant is proposing  1,520 sf of permanent wetland buffer impacts and 3,100 sf of temporary wetland buffer impacts.    Staff and the City Stormwater Section have reviewed the proposed wetland impacts and consider that  more information is needed to evaluate compliance with 12.02 Wetland Protection Standards, as  enumerated below.  E.  Standards for Wetlands Protection  (3) Encroachment into Class II wetland buffers, Class III wetlands and Class III wetland buffers,  may be permitted by the DRB upon finding that the proposed project’s overall development,  erosion control, stormwater treatment system, provisions for stream buffering, and  landscaping plan achieve the following standards for wetland protection:  (a) The encroachment(s) will not adversely affect the ability of the property to carry or  store flood waters adequately;  1. The buffer proposed to be impacted is directly connected to Potash Brook, therefore Staff  considers it to be potentially a flood storage area.  The applicant is proposing as much as four  feet of fill in this buffer area, though the volume of fill has not been quantified.  Staff considers  more information is needed to determine whether the proposed encroachment has an adverse  effect on flood storage.  (b) The encroachment(s) will not adversely affect the ability of the proposed stormwater  treatment system to reduce sedimentation according to state standards;  Staff interprets this criterion to mean that the encroachment shall not adversely impact the  erosion of sediment.    #SP‐21‐01  Staff Comments  4  2. Staff recommends the Board require the applicant to provide testimony on this criterion prior  to approval.    (c) The impact of the encroachment(s) on the specific wetland functions and values  identified in the field delineation and wetland report is minimized and/or offset by  appropriate landscaping, stormwater treatment, stream buffering, and/or other  mitigation measures.  The provided classification letter, dated 6/10/2016 and valid for five years, indicates that the  wetland does not provide function or value that is significant enough to merit protection under the  Vermont Wetland Rules at this time.  This is because the State does not regulate Class III wetlands.   However, the City has chosen to apply the wetland protection standards to Class III wetlands and  buffers, as noted in the provided wetland classification letter.    3. Staff considers the applicant should prepare a written response demonstrating compliance with  this and other criteria of this section and, based on the identified functions and values, propose  mitigation or avoidance measures to offset the impacts.  D) 13.05 OUTDOOR STORAGE AND DISPLAY  A. Outdoor storage.  Outdoor storage of goods, materials, vehicles for other than daily use, and  equipment shall be subject to the following provisions.  (1) Any outdoor storage shall be appurtenant to the primary use of the property and shall be  allowed only in nonresidential districts and upon approval of the DRB in conjunction with a  site plan, conditional use and/or PUD application  Staff recommends the Board confirm that the storage area will be used by the principal tenant  of the building.  (2) The Development Review Board may require that outdoor storage areas in connection with  commercial or industrial uses be enclosed and/or screened where the storage area may  comprise an attractive nuisance, where the proposed use of the storage areas present  opportunities for theft, or where the Board finds that said storage areas are in view of  residentially‐zoned parcels.  The applicant has stated that the existing storage area is enclosed by a chain link fence with  slats, which will be reused around the perimeter of the expanded storage area.  It appears the  storage area is proposed to be only partially enclosed.  Staff considers that if the applicant is  not concerned about theft via the opening in the enclosure, the opening faces away from  public view and is not an issue.  Staff does, however, recommend the Board include a condition  that the fence be equipped with slats to provide screening in order to maintain an attractive  appearance to the site.    E) SITE PLAN REVIEW STANDARDS  Section 14.06 of the South Burlington Land Development Regulations establishes the following general  review standards for all site plan applications:  A. Relationship of Proposed Development to the City of South Burlington Comprehensive Plan.  Due attention by the applicant should be given to the goals and objectives and the stated land  use policies for the City of South Burlington as set forth in the Comprehensive Plan.  #SP‐21‐01  Staff Comments  5  The project is located in the Northwest Quadrant in the Comprehensive Plan.  Staff considers  the proposed expansion of the current use consistent with the established uses in the area.      B. Relationship of Proposed Structures to the Site.  (1) The site shall be planned to accomplish a desirable transition from structure to site, from  structure to structure, and to provide for adequate planting, safe pedestrian movement,  and adequate parking areas.  The only proposed change to structures is the addition of a retaining wall along the proposed  ramp from the existing rear building door to the outdoor storage area.  No changes to parking,  planting areas, pedestrian movement are proposed.  Staff considers this criterion met.  (2) Parking:  (a)  Parking shall be located to the rear or sides of buildings.  Any side of a building facing  a public street shall be considered a front side of a building for the purposes of this  subsection.    No changes to parking are proposed.  While there appears to be one non‐compliant parking  space, Staff considers the proposed site modifications to not warrant rectifying this non‐ compliance.  (3) Without restricting the permissible limits of the applicable zoning district, the height and  scale of each building shall be compatible with its site and existing or anticipated  adjoining buildings.  No changes to the building are proposed.  Staff considers this criterion met.  C. Relationship of Structures and Site to Adjoining Area.  (1) The Development Review Board shall encourage the use of a combination of common  materials and architectural characteristics (e.g., rhythm, color, texture, form or detailing),  landscaping, buffers, screens and visual interruptions to create attractive transitions  between buildings of different architectural styles.  (2) Proposed structures shall be related harmoniously to themselves, the terrain and to  existing buildings and roads in the vicinity that have a visual relationship to the proposed  structures.  No changes to the building are proposed.  The applicant is proposing to modify the existing  fence around the existing outdoor storage area to encompass the proposed outdoor storage  area, as shown on the “Partial Site Plan” inset on Sheet C2‐01.  Screening of the outdoor  storage area is discussed under 13.05 above.  Staff considers other elements of these criteria  to be met.    In addition to the above general review standards, site plan applications shall meet the following specific  standards as set forth in Section 14.07 of the Land Development Regulations:  A. Access to Abutting Properties.  The reservation of land may be required on any lot for provision of  access to abutting properties whenever such access is deemed necessary to reduce curb cuts onto  an arterial or collector street, to provide additional access for emergency or other purposes, or to  improve general access and circulation in the area.  #SP‐21‐01  Staff Comments  6  No changes to access are proposed.  Staff considers this criterion met.    B. Utility Services.   Electric, telephone and other wire‐served utility lines and service connections shall  be underground. Any utility installations remaining above ground shall be located so as to have a  harmonious relation to neighboring properties and to the site.  No changes are proposed to the existing wire served utilities.  Staff considers this criterion met.  C. Disposal of Wastes.  All dumpsters and other facilities to handle solid waste, including compliance  with any recycling or other requirements, shall be accessible, secure and properly screened with  opaque fencing to ensure that trash and debris do not escape the enclosure(s).  The existing dumpsters are enclosed within the outdoor storage area and are proposed to remain  within this area.  Staff considers this criterion met.    D. Landscaping and Screening Requirements. (See Article 13, Section 13.06)  Pursuant  to  Section  13.06(A) of the  proposed  Land Development  Regulations,  landscaping  and  screening shall be required for all projects subject to site plan review.  The applicant is not proposing  any building improvements therefore no landscaping is required.  Staff considers this criterion met. F.  Low Impact Development. The use of low impact site design strategies that minimize site  disturbance,  and  that  integrate  structures,  landscaping,  natural  hydrologic  functions,  and  various  other  techniques  to  minimize  runoff  from  impervious  surfaces  and  to  infiltrate  precipitation into underlying soils and groundwater as close as is reasonable practicable to  where it hits the ground, is required pursuant to the standards contained within Article 12.  As noted above, this project is subject to an existing state stormwater permit and includes more  than ½ acre of impervious.  Projects already subject to stormwater management which add more  than  5,000  sf  of  new  impervious  are  required  to  meet  the  standards  of  12.03  Stormwater  Management Standards for the new impervious.  The project proposes 1,945 sf of new impervious  in the form of a ramp from a new overhead door to the expanded outdoor storage area.  The  expanded outdoor storage area is intended to be pervious.  If it were impervious, it would be  subject to 12.03 Stormwater Management Standards.  Staff and the City Stormwater Section have reviewed the proposed expanded storage area and  consider that it may not be adequately designed to remain pervious over time.  Specifically, the  applicant is proposing 12‐inches of 1 – 1 ½ inch clean drainage stone (which Staff assumes is the  same as saying 12‐inches of 1 – 1 ½ inch washed crushed gravel) topped with a 4‐inch “geocell  ground grid” product.  Generally, gravel is considered to become impervious over time and is  therefore treated as impervious surface unless it can be specifically demonstrated that it is  installed in such a way that compaction and subsequent loss of permeability will not occur.  Based  on  available  information,  the  specified  product  does  not  appear to be designed to remain  permeable.    4. Staff  therefore  recommends  the  Board  request  the  applicant  to  demonstrate  that  the  proposed system will remain permeable over time, and if not, either specify a different system  or propose stormwater treatment for the expanded impervious.  G. Standards for Roadways, Parking and Circulation. Standards of Section 15.12 Standards for  Roadways, Parking, and Circulation shall be met.  No changes to roadways, parking and circulation are proposed.  Staff considers this criterion met.    #SP‐21‐01  Staff Comments  7  F) OTHER  Lighting  Section 13.07 of the Land Development Regulations addresses exterior lighting as follows.  A. General Requirements.  All exterior lighting for all uses in all districts except for one‐family  and two‐family uses shall be of such a type and location and shall have such shielding as  will direct the light downward and will prevent the source of light from being visible from  any adjacent residential property or street. Light fixtures that are generally acceptable are  illustrated in Appendix D. “Source of light” shall be deemed to include any transparent or  translucent lighting that is an integral part of the lighting fixture(s). Site illumination for  uncovered areas shall be evenly distributed. Where feasible, energy efficient lighting is  encouraged.  5. Staff recommends the Board ask the applicant to describe whether any lighting is proposed  to be modified as part of this application.    RECOMMENDATION  Staff recommends that the Board work with the applicant to address the issues identified herein.      Respectfully submitted,    Marla Keene, Development Review Planner  CLASS IIIWETLAND(SEE NOTES)12 675($0%8))(5 :(7/$1'%8))(5 :(7/ $ 1 ' % 8 ))( 5352-(&7,1)250$7,21 2:1(52)5(&25'  3+<6,&$/$''5(66 *5(*25<'5,9(6287+%85/,1*72197385326(2)'(6,*17+(6(3/$16$5(%(,1*68%0,77('72$&48,5(6,7(3/$1$33529$/)25$352326('352326(',1&5($6(,17+((;,67,1*287'2256725$*($5($)257+,63523(57<(;,67,1*&21',7,216127(6 7+,63/$1'(3,&767+(3(57,1(17(;,67,1*&21',7,216$62)129(0%(5 7+,63/$1,61277+(5(68/72)$%281'$5<6859(<7+(%281'$5<,1)250$7,21'(3,&7(':$62%7$,1(')520$66(66256 65(&25'6)25%281'$5<,1)250$7,216((3/$7(17,7/('68%',9,6,213/$72)*5((175((3$5.6+813,.(52$'6287+%85/,1*72197'$7('35(3$5('%<%<758'(//&2168/7,1*(1*,1((56,1& 9(57,&$/'$780,6%$6('211$9' *(,2'  &225',1$7(6<67(0,6%$6('219(5021767$7(3/$1( 866859(<)((7  7+(&/$667+5((:(7/$1''(3,&7(',61277+(5(68/72)$1216,7(:(7/$1''(/,1($7,217+(/2&$7,21,6%$6('8321),(/'2%6(59$7,216$1',1)250$7,212%7$,1(')5207+(9(50217:(7/$1'6'(3$570(17,1&/8',1*127(6)520$9,6,7727+(6,7(%<7,1$+($7+&+,77(1'(1&2817<',675,&7:(7/$1'6(&2/2*,67 7+(/2&$7,212)(;,67,1*81'(5*5281'87,/,7,(6$1',03529(0(1766+2:1$5(%$6('215(6($5&+87,/,7<3/$163529,'('%<27+(56$1'25685)$&((9,'(1&((1&2817(5('$1':(5(2%7$,1(',1$0$11(5&216,67(17:,7+7+(25',1$5<67$1'$5'2)352)(66,21$/&$5($1'+$9(127%((1,1'(3(1'(17/<9(5,),('%<7+(2:1(5257+('(6,*1(1*,1((5$'',7,21$/87,/,7,(61276+2:10$<(;,67(1*,1((56+$//%(127,),(',)$1<',6&5(3$1&,(6$5((1&2817(5('$&78$//2&$7,212)81'(5*5281'87,/,7,(60$<9$5<',*6$)(0867%(&217$&7('35,2572$1<(;&$9$7,21&$//',*6$)(  =21,1*127(6=21,1*',675,&70,;(',1'8675,$/ &200(5&,$/,&0$;,0806,7(&29(5$*(%8,/',1*621/<%8,/',1*63$5.,1*$1'$//27+(5,03(59,286685)$&(66(7%$&.6)5217)((76,'()((75($5)((7/(*(1'3523(57</,1(6(7%$&.6%8))(5)(1&(&+$,1/,1.87,/,7<32/(%(1&+0$5.3$9(''5,9(2552$'&217285(;,67,1*/,*+7),;785(:(7/$1'('*(&217285352326('62,/67(673,7:(7/$1'%8))(5',6785%$1&(127(67(0325$5<,03$&7 &216,'(5('72%(7+($5($2)%8))(5=21(%(7:((17+(352326('7(0325$5<6,/7)(1&($1'7+(352326('&+$,1/,1.)(1&(648$5()((73(50$1(17,03$&7 &216,'(5('72%(7+($5($2)%8))(5=21(2&&83,('%<7+(352326('6725$*($5($(;3$16,21648$5()((76:$/( December 2, 2020 Page 1Project Narrative – Site Plan Prepared by: Peter Mazurak, P.E. Project Name: 20 Gregory Drive - outdoor storage area.Project Location: The property is located along the east side of Gregory Drive and north of Kimball Ave. The 911 address is 20 Gregory Drive, South Burlington, VT 05403. The property is also designated as “Lot 13” of the Green Tree Park commercial subdivision. Property Owner / Applicant: 20 GREGORY DR SOUTH BURLINGTON VT LLC, 6 Storrs Street, Concord, NH, 03301 Detailed description of the proposed project: The applicants are proposing to increase the existing outdoor storage area for a commercial building use on the site. A new overhead door will be installed within the back wall of the building, (East side/facing brook). This door will lead out to the proposed expanded outdoor storage area. No other buildings are proposed. Demonstration of compliance with the applicable review standards: From a review of the applicable review standards, in particular 13.05-Outdoor Storage and Article 14-Site Plan, it is our opinion that the proposed project is in compliance. List of submission elements ‡This Narrative ‡Site Plan entitled “The Granite Group”, date 11/11/2020, revised 12/02/2020 by Apex Engineering, LLC. List of waivers: None. Restrictions, Covenants, Easements: The property contains a 35' x 35' easement for a building owned by New England Telephone. No other restrictions, covenants, or easements are proposed. Landscaping and Screening: The existing trees and tree buffer will remain unchanged. The existing chain link fence with slats will be reused to line the edge of the expanded outdoor storage area. The proposed storage area will be built in an area that contains a grassed lawn. The only vegetation proposed to be disturbed is the grassed lawn. Outdoor Storage area and Dumpsters: The site contains an existing fenced outdoor storage area (43' x 76') that is proposed to be expanded to 63' x 115'. This storage area is used for piping and other goods sold by the business. This area also contains two dumpsters used for the business. Stormwater and Erosion Control: No State Stormwater permit is needed. This property is designated as Lot 13 of the Green Tree Park subdivision and is covered under the state stormwater permit # 3409-INDS. It was determined that there is 2,000 square feet of allowable impervious area expansion to remain below the 5,000 square foot allowance by the state. The area added to the outdoor storage is proposed to be 3,800 square feet. Of this expansion, 1,945 square feet will be impervious pavement and 1,855 square feet will be built with a permeable geo-grid. Stormwater runoff from the storage area will be directed over grassed areas and rock lined swales to the existing stormwater basin on the lot. Page 2Erosion and sediment control will adhere to the Vermont “Low Risk Site Handbook”. Silt fence will be installed prior to the start of the earthwork. All disturbed areas will be restored with topsoil, seed and mulch. An existing crushed stone overflow area adjacent to the existing outdoor parking area will be expanded. Wastewater and Water systems, power service, natural gas service: No changes proposed. Access to Property: There is an existing access driveway extending from Gregory Drive for access. The parking area contains well marked vehicle parking spaces for both customers and staff. There are two marked handicapped accessible parking spaces near the front entrance of the building. A bicycle rack is located near the front entrance of the building. Project Construction Schedule: Once approved, it is estimated that the construction of the project will take approximately 2 weeks. If the construction was to occur in the winter, the final paving and landscaping would occur the next spring. The estimated costs of the improvements is $45,000. &ƌŽŵ͗,ĞĂƚŚ͕dŝŶĂ^ĞŶƚ͗&ƌŝĚĂLJ͕:ƵŶĞϭϬ͕ϮϬϭϲϭϭ͗ϰϯDdŽ͗ΖDŝĐŚĂĞůDĂŝŶĞƌΖ^ƵďũĞĐƚ͗Z͗tĞƚůĂŶĚůĂƐƐŝĨŝĐĂƚŝŽŶͲϮϬ'ƌĞŐŽƌLJƌŝǀĞ͕^ŽƵƚŚƵƌůŝŶŐƚŽŶ ‹‹‡ǡ‡Ž‘™‹•ƒŽƒ•• †‡–‡”‹ƒ–‹‘ˆ‘”›‘—””‡…‘”†•Ǥ ƒ˜‡ƒ‰‘‘†™‡‡‡†Ǥ  Ž‡ƒ•‡„‡ƒ†˜‹•‡†–Š‡”‡‹•ƒŽƒ•• ™‡–Žƒ†‘–Š‡’”‘’‡”–›Ž‘…ƒ–‡†ƒ–͚͘ ”‡‰‘”›”‹˜‡‹‘—–Š—”Ž‹‰–‘ǤŠ‹•†‡–‡”‹ƒ–‹‘ ‹•„ƒ•‡†‘ƒ•‹–‡˜‹•‹–…‘†—…–‡†‘͞Ȁ͠Ȁ͚͙͘͞ǡƒ†‡„›‹ƒ ‡ƒ–Šƒ†ƒ……‘’ƒ‹‡†„›‹‡ƒ‹‡”Ǥ      ǣ Š‡•—„Œ‡…–™‡–Žƒ†‹•‘–ƒ’’‡†‘–Š‡‡”‘–‹‰‹ˆ‹…ƒ–‡–Žƒ† ˜‡–‘”›ƒ’•ǡ‘”†‘‡•‹–‡‡––Š‡’”‡•—’–‹‘•Ž‹•–‡† ‹‡…–‹‘͜Ǥ͞‘ˆ–Š‡‡”‘–‡–Žƒ†—Ž‡•Ǥ   ǣ Š‡‡…”‡–ƒ”›Šƒ•†‡–‡”‹‡†„ƒ•‡†‘ƒ‡˜ƒŽ—ƒ–‹‘–Š‡™‡–Žƒ†–Šƒ–‹–†‘‡•‘–’”‘˜‹†‡ˆ—…–‹‘‘”˜ƒŽ—‡–Šƒ–‹••‹‰‹ˆ‹…ƒ– ‡‘—‰Š–‘‡”‹–’”‘–‡…–‹‘—†‡”–Š‡‡”‘–‡–Žƒ†—Ž‡•ƒ––Š‹•–‹‡Ǥ‡…ƒ—•‡™‡–Žƒ†…Šƒ”ƒ…–‡”ǡ•‹œ‡ǡƒ†ˆ—…–‹‘…ƒ …Šƒ‰‡‘˜‡”–‹‡ǡ–Š‹•†‡–‡”‹ƒ–‹‘‹•‘Ž›˜ƒŽ‹†ˆ‘”ˆ‹˜‡›‡ƒ”•Ǥ ˆ‹’ƒ…–•ƒ”‡’”‘’‘•‡†ˆ‹˜‡›‡ƒ”•„‡›‘†–Š‡†ƒ–‡‘ˆ–Š‹•Ž‡––‡”ǡƒ ’‡”‹–ƒ›„‡”‡“—‹”‡†Ǥ ”‡…‘‡†–Šƒ–›‘—Šƒ˜‡ƒ‡–Žƒ†•”‘‰”ƒ…‘Ž‘‰‹•–”‡Ǧ‡˜ƒŽ—ƒ–‡–Š‡’”‘–‡…–‹‘•–ƒ–—•‘ˆ–Š‡ ™‡–Žƒ†ƒ–•—…Š–‹‡Ǥ‘—”–‘™ƒ†–Š‡”›‘”’•‘ˆ‰‹‡‡”•ȋ͚͘͠Ǧ͚͟͠Ǧ͚͛͠͡Ȍƒ›ƒŽ•‘Šƒ˜‡”‡‰—Žƒ–‹‘•’‡”–ƒ‹‹‰–‘–Š‹• ™‡–Žƒ†Ǥ   ‹…‡”‡Ž›ǡ  ‹ƒ ‡ƒ–Š  ‹ƒ ‡ƒ–Šǡ‹•–”‹…–‡–Žƒ†…‘Ž‘‰‹•– Š‹––‡†‡‘—–› ͚͘͠Ǧ͘͜͡Ǧ͚͚͘͞ –‹ƒǤŠ‡ƒ–Š̻˜‡”‘–Ǥ‰‘˜  ‡”‘–‡’ƒ”–‡–‘ˆ˜‹”‘‡–ƒŽ‘•‡”˜ƒ–‹‘ ͙͙͙‡•–– ••‡š —…–‹‘ǡ‡”‘–͚͘͜͝͝ ™™™Ǥ™ƒ–‡”•Š‡†ƒƒ‰‡‡–Ǥ˜–Ǥ‰‘˜ ‡‡™Šƒ–™‡ǯ”‡—’–‘‘‘—”Ž‘‰ǡ Ž‘™Ǥ  &ƌŽŵ͗ŵĂŝŶĞƌ͘ŵŝĐŚĂĞůΛŐŵĂŝů͘ĐŽŵ΀ŵĂŝůƚŽ͗ŵĂŝŶĞƌ͘ŵŝĐŚĂĞůΛŐŵĂŝů͘ĐŽŵ΁KŶĞŚĂůĨKĨDŝĐŚĂĞůDĂŝŶĞƌ ^ĞŶƚ͗DŽŶĚĂLJ͕DĂLJϮϯ͕ϮϬϭϲϮ͗ϯϲWD dŽ͗,ĞĂƚŚ͕dŝŶĂфdŝŶĂ͘,ĞĂƚŚΛǀĞƌŵŽŶƚ͘ŐŽǀх ^ƵďũĞĐƚ͗ZĞ͗tĞƚůĂŶĚůĂƐƐŝĨŝĐĂƚŝŽŶͲϮϬ'ƌĞŐŽƌLJƌŝǀĞ͕^ŽƵƚŚƵƌůŝŶŐƚŽŶ  +L7LQD  7KDWVRXQGVOLNHDSODQ, OOSODQRQ-XQHWKDW,W VDW*UHJRU\'ULYHLQ6RXWK%XUOLQJWRQLI,KDYHQ WPHQWLRQHGWKDW DOUHDG\ZKHUH*UDLQJHUXVHGWREH 7KDQNV0LNH2Q0RQ0D\DW$0+HDWK7LQD7LQD+HDWK#YHUPRQWJRY!ZURWHŠƒ•ˆ‘”–Š‡‹ˆ‘”ƒ–‹‘Ǥ …ƒ†‘‡†‡•†ƒ› —‡͠ƒ–‘‘Ǥ‡–‡‘™‹ˆ–Šƒ–™‘”•Ǥ‡•–ǡ‹ƒ  ‹ƒ ‡ƒ–Šǡ‹•–”‹…–‡–Žƒ†…‘Ž‘‰‹•– Š‹––‡†‡‘—–› ͚͘͠Ǧ͘͜͡Ǧ͚͚͘͞ –‹ƒǤŠ‡ƒ–Š̻˜‡”‘–Ǥ‰‘˜  ‡”‘–‡’ƒ”–‡–‘ˆ˜‹”‘‡–ƒŽ‘•‡”˜ƒ–‹‘ ͙͙͙‡•–– ••‡š —…–‹‘ǡ‡”‘–͚͘͜͝͝ ™™™Ǥ™ƒ–‡”•Š‡†ƒƒ‰‡‡–Ǥ˜–Ǥ‰‘˜ ‡‡™Šƒ–™‡ǯ”‡—’–‘‘‘—”Ž‘‰ǡ Ž‘™Ǥ  &ƌŽŵ͗ŵĂŝŶĞƌ͘ŵŝĐŚĂĞůΛŐŵĂŝů͘ĐŽŵ΀ŵĂŝůƚŽ͗ŵĂŝŶĞƌ͘ŵŝĐŚĂĞůΛŐŵĂŝů͘ĐŽŵ΁KŶĞŚĂůĨKĨDŝĐŚĂĞůDĂŝŶĞƌ ^ĞŶƚ͗&ƌŝĚĂLJ͕DĂLJϮϬ͕ϮϬϭϲϭϬ͗ϬϯD dŽ͗,ĞĂƚŚ͕dŝŶĂфdŝŶĂ͘,ĞĂƚŚΛǀĞƌŵŽŶƚ͘ŐŽǀх ^ƵďũĞĐƚ͗ZĞ͗tĞƚůĂŶĚůĂƐƐŝĨŝĐĂƚŝŽŶͲϮϬ'ƌĞŐŽƌLJƌŝǀĞ͕^ŽƵƚŚƵƌůŝŶŐƚŽŶ  +L7LQD  &XUUHQWXVHLVDZDUHKRXVHSURSRVHGXVHLVDXWRPRELOHVDOHV VHUYLFH7RSHUPLWWKLVFKDQJHRIXVHZH GQHHGWRDGG SDUNLQJDVUHTXLUHGE\WKHFLW\ V]RQLQJUXOHV7KH&LW\ V]RQLQJUXOHVDOVRFRQILQHXVWRDIDLUO\VPDOODUHDRQWKHHDVWVLGHRIWKH VLWHDODUJHSDUWRIZKLFKLVRFFXSLHGE\WKHZHWODQGDQGLW VIRRWEXIIHU, YHSOD\HGZLWKVRPHOD\RXWRSWLRQVEXWZHWKLQN ZH OOSUREDEO\QHHGWRXVHDWOHDVWDSRUWLRQRIWKHEXIIHU  7KDQNV 0LNH  2Q7KX0D\DW30+HDWK7LQD7LQD+HDWK#YHUPRQWJRY!ZURWH ‹‹‡ǡ  Šƒ•ˆ‘”…‘–ƒ…–‹‰‡Ǥƒ›‘—‰‹˜‡‡•‘‡‘”‡‹ˆ‘”ƒ–‹‘ƒ„‘—––Š‡’”‘Œ‡…–’”‘’‘•ƒŽǫ ǯŽŽ‰‡–„ƒ…–‘›‘—‡ƒ”Ž› ‡š–™‡‡–‘•…Š‡†—Ž‡ƒ•‹–‡˜‹•‹–‘…‡ ǯ„ƒ…‹–Š‡‘ˆˆ‹…‡Ǥ—–ƒ•‘ˆ‘™‹–ǯ•Ž‘‘‹‰Ž‹‡͚Ǧ͛™‡‡•‘—–Ǥ  ƒ’’”‡…‹ƒ–‡›‘—”’ƒ–‹‡…‡ǡ ‹ƒ  ‹ƒ ‡ƒ–Šǡ‹•–”‹…–‡–Žƒ†…‘Ž‘‰‹•–Š‹––‡†‡‘—–›͚͘͠Ǧ͘͜͡Ǧ͚͚͘͞–‹ƒǤŠ‡ƒ–Š̻˜‡”‘–Ǥ‰‘˜ ‡”‘–‡’ƒ”–‡–‘ˆ˜‹”‘‡–ƒŽ‘•‡”˜ƒ–‹‘ ͙͙͙‡•–– ••‡š —…–‹‘ǡ‡”‘–͚͘͜͝͝ ™™™Ǥ™ƒ–‡”•Š‡†ƒƒ‰‡‡–Ǥ˜–Ǥ‰‘˜ ‡‡™Šƒ–™‡ǯ”‡—’–‘‘‘—”Ž‘‰ǡ Ž‘™Ǥ  &ƌŽŵ͗ŵĂŝŶĞƌ͘ŵŝĐŚĂĞůΛŐŵĂŝů͘ĐŽŵ΀ŵĂŝůƚŽ͗ŵĂŝŶĞƌ͘ŵŝĐŚĂĞůΛŐŵĂŝů͘ĐŽŵ΁KŶĞŚĂůĨKĨDŝĐŚĂĞůDĂŝŶĞƌ ^ĞŶƚ͗tĞĚŶĞƐĚĂLJ͕DĂLJϭϴ͕ϮϬϭϲϭϬ͗ϰϰD dŽ͗,ĞĂƚŚ͕dŝŶĂфdŝŶĂ͘,ĞĂƚŚΛǀĞƌŵŽŶƚ͘ŐŽǀх ^ƵďũĞĐƚ͗tĞƚůĂŶĚůĂƐƐŝĨŝĐĂƚŝŽŶͲϮϬ'ƌĞŐŽƌLJƌŝǀĞ͕^ŽƵƚŚƵƌůŝŶŐƚŽŶ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or: Granite GroupProject: 20-021 Soil EvaluationSite: 20 Gregory Drive, South Burlington, VTBy: Peter Mazurak, P.E.Date: 11/16/2020TP 1 Mottling @48”- Common, Medium, Distinct,10YR4/60-8” A/Fill Sandy Loam Granular 10 YR 3/48-48” C1/ Fill Sandy Loam Granular 10YR 4/3 48-56” C2 Clay Loam Blocky / Weak 10YR 6/2 TP 2 Mottling @36”- Common, Medium, Distinct,10YR4/6 0-4” A/Fill Sandy Loam Massive 10YR 3/4 4-36” C1/Fill Loamy Sand Granular, Cobbly 2.5Y 5/4 36-40” C2 Clay Loam Blocky / Weak 10YR 6/2 Infiltration testing result: 0.9 inches / hour Vtotal 340.4 Cubic Feet where: Ap 1918 Equation 4-9 n0.33 dt 1 fc 0.9 t2 Volume to be satisfied 335.7 Cubic Feet where: Ap 1918 Equation 4-10 P1yr 2.1