HomeMy WebLinkAboutZB-91-0000 - Decision - 1233 Shelburne RoadPLANNING COMMISSION
CITY OF SOUTH BURLINGTON
RE: APPLICATION OF LOCHMORE ASSOCIATES AND ALEXANDER LEWIS
This matter came before the South Burlington Planning Commission
pursuant to the provisions of Section 19.10 and 11.50 of the
South Burlington Zoning Regulations and Section 204 of the South
Burlington Subdivision Regulations on application of Lochmore
Associates and Alexander Lewis, hereinafter "Applicants" for
approval to: 1) construct a 17,000 square foot office/retail
building; and 2) construct a 103 room hotel in conjunction with
an existing planned commercial development consisting of office,
retail, hair salon and restaurant use, 1233 Shelburne Road as
depicted on an 11 page set of plans, page one entitled"Lakewood
Commons, U.S. Route 7, South Burlington, Vermont, Survey Plat,"
prepared by Trudell Consulting Engineers, Inc, and dated 10/5/90
and last revised on 11/29/90. The Applicants were present at all
of the public meetings. Based upon the evidence submitted at the
meetings and as part of the application the Planning Commission
hereby renders the following decision on this application:
FINDINGS OF FACT
1. Lakewood Associates Property Management, Inc. and Alexander
Lewis are the record owners of the land which is the subject
of this application which is commonly known as Lakewood
Commons located at 1233 Shelburne Road.
2. This property is presently developed with five (5)
commercial buildings consisting of office, retail, hair
salon and restaurant uses. This property is in a Commercial
1 District.
3. By their application the Applicants seek approval to
construct a 17,000 sq. ft. office/retail building and a 103
room hotel with associated parking and landscaping.
4. Access to the development would be via a 24 foot wide
ingress only driveway off Shelburne Road which narrows to 14
feet just before it enters the parking area. The extra
width is to provide a parking lane for use of the project
directory. The curb cut for this driveway would be wide
enough to accommodate turning movements of large trailer
trucks. The site can also be accessed via 3 other curb cuts
on Shelburne Road which primarily serve Al Lewis Motors. A
fourth curb cut serving the Lewis Motors property will be
closed as part of this project. Along Holmes Road there are
two curb cuts which can provide access to this development.
The easterly curb cut primarily serves the car dealership
while the westerly one provides access to a driveway which
directly serves the new development and fire station. This
access is for both ingress and egress. Aisle widths meet
City standards.
5. The entire development requires 484 parking spaces by
standard. 397 spaces are proposed representing a shortfall
of 87 spaces or 18%. All outside parking stall dimensions
and aisle widths meet minimum requirements. Details of the
56 space parking garage underneath the proposed hotel were
not submitted. A revised parking study for this project was
conducted by Resource Systems Group. It was the study's
conclusion that the "total number of parking spaces planned
for the Lakewood expansion is more than adequate to meet
peak parking needs."
6. Total building coverage for the entire project will be 18.3%
(maximum allowed by ordinance is 30%). Total overall
coverage will be 62.3% (maximum allowed by ordinance is
70%).
7. The minimum landscaping requirement for this project is
$27,500 and this requirement is being met.
8. This project requires a sewer allocation of 16,609 gallons
per day. Sewer capacity at the Bartlett Bay Treatment
facility is unavailable at this time. The project would
have to be placed on a waiting list until such time as
treatment capacity is available.
9. The height of the proposed hotel building would be 45 feet.
10. The stormwater drainage plans have been evaluated by Wagner,
Heindel and Noyes. It is their conclusion that the
stormwater management goals of the Planning Commission will
be met.
11. Pursuant to Section 11.504 a. of the South Burlington Zoning
Regulations, the Planning Commission has specified that the
following intersections shall have a "C" level of service
(LOS): Allen Road & Shelburne Rd.and Green Mountain Dr. and
Shelburne Rd. According to a traffic study entitled
"Traffic Impact Review of L & M Park" prepared by Resource
Systems Group and dated Nov 21, 1989 "the Allen Road and
Green Mountain Drive intersections both had poor LOS of F
and D respectively." The proposed expansion will result in
an additional 151 vehicles trips during the PM peak hour.
This increase in trip generation will worsen the LOS at
these intersections.
12. Several Planning Commission members have observed the
stacking of north bound vehicles on Shelburne Road in the
center lane waiting to enter the Lakewood Commons project.
This stacking results in the blocking of south bound traffic
wishing to make a left turn into Imperial Drive.
13. Several owners of property within the Lakewood Commons
project have testified that they have observed parking
problems in the front of the project and around Jake's
Restaurant because the parking spaces are not conveniently
located to where the parking demand is being generated.
14. The access point for this project on Shelburne Road is
located approximately 160 feet north of the Imperial Drive -
Shelburne Road intersection.
CONCLUSIONS
1. Table I of the South Burlington Zoning Regulations requires
that this entire development have 484 parking spaces
available. Since the applicants will only be providing 397
parking spaces representing a shortfall of 87 spaces or 18%1
the Planning Commission concludes that the parking
requirements will not be met.
2. Section 18.112 of the South Burlington Zoning Regulations
requires that the maximum height for all structures shall be
no more than 35 feet. The Planning Commission may approve
an increase in height for a structure up to 45 feet in the
Cl and other Districts if it determines that the building
will meet certain standards. The Planning Commission
concludes that the proposed 45 feet high hotel will relate
aesthetically with existing buildings, will not detract from
scenic views, and will allow for greater retention of green
space. The Planning Commission further concludes that the
Applicants will be in compliance with Section 18.112.
3. Section 11.504 a. of the South Burlington Zoning Regulations
requires that "those intersections specified by the
Planning Commission, shall have a 'C' level of service... or
better, at the peak street hour, including the anticipated
impact of the fully developed proposed PCD." The Planning
Commission concludes that since the level of service for the
Allen Road and Green Mountain Drive intersections are
presently F and D respectively the requirements of Section
11.504 a. are not being met and the situation will worsen
with the addition of 151 additional vehicles trips during
the PM peak hour.
4. Section 11.504 d. (5) of the South Burlington Zoning
Regulations requires that the design of the project access
address "... left -turn stacking lanes." Since it has been
observed that there presently exists an inadequate left -turn
stacking lane into this development and no improvements have
been proposed, the Planning Commission concludes that
Section 11.504d.(5) is not being met.
5. Section 11.505b. of the South Burlington Zoning Regulations
requires that parking areas provide convenient access to
building entrances. It has been observed that current
parking areas are not conveniently located to where the
current demand is located. The proposed uses will increase
parking demand in the areas of concern, and it is the
Commissions' opinion that the proposed parking layout does
not adequately address this situation. The Planning
Commission concludes that Section 11.505b. is not being met.
6. Section 11.504d.(2) of the South Burlington Zoning
Regulations requires that the design of the project access
address the alignment of access points with existing
intersections. Since the Shelburne Road access to the
project will be located approximately 160 feet to the north
of the Imperial Drive -Shelburne Road intersection, the
Planning Commission concludes that this access point is not
aligned with an existing intersection so therefore the
Applicants are not in compliance with Section 11.504 d.(2).
7. Section 417d. of the South Burlington Subdivision
Regulations requires the Planning Commission to evaluate any
proposed major subdivision, according to the standard that
the development "will not cause unreasonable highway
congestion or unsafe conditions with respect to use of the
highways, existing or proposed." Due to the increase in
trip generation which will worsen the LOS at the Allen Road
and Green Mountain Drive inter- sections, the inadequate
left -turn stacking lane into the project and the non-
alignment of the project access point with the Imperial
Drive intersection, the Planning Commission concludes that
this proposed major subdivision will cause unreasonable
highway congestion and unsafe conditions with respect to use
of the highways, existing or proposed.
DECISION
Based on the above Findings of Fact and Conclusions, the Planning
Commission makes the following decision:
The Planning Commission hereby denies the Applicants' request to:
1) construct a 17,000 square foot office/retail building; and 2)
construct a 103 room hotel, for the following reasons:
a) The application does not meet the requirements of Table I of
the zoning regulations. 484 parking spaces are required and
only 397 spaces are being provided.
b) The application does not meet the requirements of Section
11.504 a. of the zoning regulations. The specified Allen
Road and Green Mountain Drive intersections have level of
service of F and D respectively.
I
c) The application does not meet the requirements of Section
11.504d.(5) of the zoning regulations. There presently
exists an inadequate left -turn stacking lane which will be
made worse with the construction of the proposed commercial
buildings.
d) The application does not meet the requirements of Section
11.505b. of the zoning regulations. Parking areas are not
located so as to provide convenient access to building
entrances.
e) The application does not meet the requirements of Section
11.504d. (2) of the zoning regulations. The project access
point on Shelburne Road is not aligned with the Imperial
Drive -Shelburne Road intersection.
f) The application does not meet the requirements of Section
417d. of the subdivision regulations. The project will
cause unreasonable highway congestion and unsafe conditions
with respect to use of the highways, existing or proposed.
Dated at South Burlington, Vermont, this " day of
1991
Chairman of Planning Commissio