HomeMy WebLinkAboutSP-18-57 - Supplemental - 1200 Airport DriveXXXXXXXXXX X X X XXXXXXXXXXXXXXX
X
TRANS
F
O
R
M
E
R
P
A
D
SSSSSS1-191-1915-33 15-33
RUNWAY 15-33
TAXIWAY GTAXIWAY HTAXIWAY MAIRPORT PKWYTAXIWAY GKIRB
Y
R
O
A
D
T
A
X
I
W
A
Y
A
DUMONT AVE
R
U
N
W
A
Y
1
9
-
1
PROPOSED AIRCRAFT
HOLDING BAY
PROPOSED
RELOCATION OF
EXISTING AIRFIELD
PERIMETER ROAD RECONSTRUCTION
OF EMERGENCY
VEHICLE STAGING
AREA
PROPOSED
REHABILITATION OF
EXISTING AIRFIELD
PERIMETER ROAD
PROPOSED
REHABILITATION OF
EXISTING AIRFIELD
PERIMETER ROAD
THIS PORTION OF
EXISTING TAXIWAY A WAS
PREVIOUSLY APPROVED
TO BE REMOVED AND IS
NOW PROPOSED TO BE
RECONSTRUCTED
PROPOSED
RECONSTRUCTION
OF AIR CARRIER
APRON
TERMINAL
PARKING
GARAGE TAXIWAY BAI
R
P
O
R
T
D
R
I
V
E
STORMWATER
DETENTION
CHAMBERS
STORMWATER
DETENTION
CHAMBERS
T
A
X
I
W
A
Y
A
PROPOSED JET
BLAST DEFLECTOR
HEIGHT = 14'
LENGTH = 1,116'
EXISTING AIRFIELD
PERIMETER ROAD
PROPOSED TO BE
REMOVED AND
RELOCATEDSEE INSERT BELOW
AIRPORT
PROPERTY LINE
X X X XXXXXXXXXXXXXXXXXXXXXXXXXXXXXX X X
SSPROPOSED AIRCRAFT
HOLDING BAY
PROPOSED JET
BLAST DEFLECTOR
HEIGHT = 14'
LENGTH = 1,116'
PROPOSED
RELOCATION OF
EXISTING AIRFIELD
PERIMETER ROAD
EXISTING AIRFIELD PERIMETER
ROAD PROPOSED TO BE
REMOVED AND RELOCATED
AIRPORT PKWY
KIRB
Y
R
O
A
D 56'65'69'58'AIRPORT
PROPERTY LINE
Drawing No.
Scale
Issued
Title
Client/Project
Project No.
Sheet
of
ByIssued Appd.YY.MM.DD
File Name:
Copyright Reserved
The Contractor shall verify and be responsible for all dimensions. DO
NOT scale the drawing - any errors or omissions shall be reported to
The Copyrights to all designs and drawings are the property of
authorized by Stantec is forbidden.
Stantec without delay.
Stantec. Reproduction or use for any purpose other than that
ORIGINAL SHEET - ARCH D
Stantec Consulting Services Inc.
55 Green Mountain Drive
South Burlington VT 05403 U.S.A.
802.864.0223
802.864.0165
www.stantec.com
Fax.
Tel.
Permit-Seal
Chkd.Dwn.Dsgn.YY.MM.DD
SITE PLAN
TAXIWAY 'G', PHASE 2
DMZ CG DMZ XXXXXX
SK-503 2
AS NOTED
2
N
MODIFICATIONS
CURRENTLY APPROVED
PROPOSED MODIFICATIONS
FOR APPROVAL
BURLINGTON INTERNATIONAL AIRPORT
CONSTRUCT, MARK AND LIGHT PARALLEL
TAXIWAY G, PHASE 2
South Burlington, Vermont
195311195
2
PROPOSED MODIFICATIONS FOR APPROVAL
·ADD PARALLEL AIRCRAFT HOLDING BAY WITH JET
BLAST DEFLECTOR
·EXPAND TAXIWAY INTERSECTIONS TO FACILITATE
TURNING MOVEMENTS OF DESIGN AIRCRAFT
·RECONSTRUCT AIR CARRIER APRON
·RELOCATE PORTION OF EXISTING PERIMETER
ROAD AND REHABILITATE SEGMENTS OF EXISTING
PERIMETER ROAD PROPOSED TO BE USED AS HAUL
ROUTE FOR PROJECT
LEGEND
AIRPORT PROPERTY LINE
2 ADDED INSERT DMZ JBL 19.01.04