Loading...
HomeMy WebLinkAboutSD-20-24 SP-20-029 - Supplemental - 0510 Shelburne Road (25)OH OH OH OH OH OH OH OHOHOHOHOHG SSSSW S04°11'24"W 124.97'N84°39'50"W70.40'S02°52'32"W 25.16'N84°38'10"W140.13'N04°15'57"E149.74'TIELINES85°51'02"E37.56'TIELINE S04°07'55"W69.46'WWWWWWWS84°45'53"E139.94'S84°42'19"E69.81'S04°27'43"W 124.91'0FeetGraphicScale202040608015°±VT GridMagnetic PROJECTLOCATIONS1-01This plat was created using pigment based ink on stable media DescriptionRevisionsByDate#478BLAIRPARKROAD|WILLISTON,VERMONT054958028796331|WWW.TCEVT.COMTRUDELLCONSULTINGENGINEERSDate:Scale:DrawnBy:Crdfile:Sheet:SurveyedBy:GERALDM.STOCKMANNo.109298FieldBk:Project#:16/11/20MADChangeTitleUTILITYPOLEOVERHEADUTILITYLINEREINFORCINGBAR(FOUND)CONCRETEMONUMENT(FOUND)REBAR(TOBESET)IRONPIPE(FOUND)CALCULATEDPOINTOHtaxmapno.1540-00510ChamplainOilCompany,INC.v.126p.13020,943sqft0.48acLEGEND19-202THISPLATISBASEDONAFIELDSURVEYWHICHMEETSOREXCEEDSTHEMINIMUMSTANDARDSASSETFORTHBYTHEVERMONTBOARDOFLANDSURVEYORS.FIELDEVIDENCE,PERTINENTRECORDINFORMATION,ANDPAROLEEVIDENCEWASUSEDINTHECALCULATIONANDDETERMINATIONOFTHEBOUNDARIESSHOWNONTHISPLAT.ANYINCONSISTENCIESARESHOWNHEREONTOTHEBESTOFMYKNOWLEDGE.THISPLATMEETSTHEREQUIREMENTSOF27VSA1403.MARKA.DAY,L.S.#732_____________________________________________ChamplainOilCompany,Inc.&BaconStreetProperties,LLC510ShelburneRoad-SouthBurlington,VermontSubdivisionPlatHABEXISTINGBOUNDARYLINE19-20219-202HAB1"=20'09/13/19NOTES:1.THISPLATISBASEDONDEEDSRESEARCHEDINTHECITYOFSOUTHBURLINGTONLANDRECORDSANDFEATURESLOCATEDINTHEFIELDWITHATOTALSTATIONON09/12/19.2.BEARINGSAREBASEDONVERMONTSTATEPLANEGRIDNORTHESTABLISHEDWITHRTKOBSERVATIONSFROMVERMONTCORSSTATIONVTVRS.3.THESEPARCELSWERECONVEYEDTOCHAMPLAINOILCOMPANY,INC.INVOLUME126PAGE130ANDBACONSTREETPROPERTIES,LLCINVOLUME609PAGE786.4.REBARSSETARENO.5REINFORCINGBARSWITHALUMINUMCAPSSTAMPED"TCELANDSURVEYING,LLS732".5.DISTANCESARESHOWNTOTHEHUNDREDTHOFAFOOTANDBEARINGSARESHOWNTOTHESECONDFORMATHEMATICALCLOSUREPURPOSESONLY.6.ANATTEMPTHASBEENMADETOIDENTIFYORDELINEATEEASEMENTS,RIGHTSOFWAY,LEASELANDS,ENCROACHMENTS,ETC.OBSERVEDINTHEFIELDORREADILYFOUNDINTHELANDRECORDS.ADDITIONALENCUMBRANCESMAYEXISTWHICHARENOTSHOWNONTHISPLAT.7.UNDERGROUNDUTILITYLINESSHOWNAREBASEDONABOVEGROUNDSTRUCTURESANDPLANSOFRECORD.ACTUALLOCATIONOFUNDERGROUNDLINESMAYVARY.8.THERIGHTOFWAYLIMITSOFU.S.ROUTE7AREBASEDONSURVEYSOFRECORD.BACONSTREETWASDEEDEDTOTHECITYONSOUTHBURLINGTONINVOLUME543PAGE348ANDISDEPICTEDASSHOWNONPLATREFERENCE3.taxmapno.0090-00017BaconStreetProperties,LLCv.609p.7868,757sqft0.20actaxmapno.1540-00520GermaniaPropertyGroup,LLCv.975p.135mapslide548,555,589taxmapno.0090-00025JohnLarkin,INCv.1375p.324mapslides548,555,589,600taxmapno.0090-00014DeimerProperties,INC.v.479p.704mapslide67PLATREFERENCES:1."PLANOFLAND&EASEMENTS518SHELBURNESTREETSOUTHBURLINGTON,VERMONT,THOMASA.FARRELL"DATEDOCTOBER24,1959ANDRECORDEDONMAPSLIDE36INTHECITYOFSOUTHBURLINGTONLANDRECORDS.2."COUNTRYCLUBESTATES,INC.S.BURLINGTON,VERMONT,SUBDIVISIONOFSECTIONI"REVISEDAUGUST15,1926BYELIZBETHBOOTESCLARK,LANDSCAPEARCHITECTANDRECORDEDONMAPSLIDE67INTHECITYOFSOUTHBURLINGTONLANDRECORDS.3."REVISEDFINALPLATO'DELLPARKWAYPUD,FARRELLSTREETSOUTHBURLINGTON,VERMONT"DATEDJUNE20,2005LASTREVISED1-25-11BYCIVILENGINEERASSOCIATESINC.,ANDRECORDEDONMAPSLIDES#589,555,548INTHECITYOFSOUTHBURLINGTONLANDRECORDS.BACONSTREETU.S.ROUTE 7 &SHELBURNE ROAD CATCHBASINBOLLARDFIREHYDRANTUTILITYPOLEVALVEMONITORWELL5/8"DOWN0.5'5/8"DOWN0.1'ALUMINUMCAP"LS60812"5/8"DOWN0.3'DISTUREDANDBENT4"X4"X0.6'DISTURBED5/8"FLUSH5/8"FLUSH11/2"DOWN1.5'RAILROADSPIKEFOUNDFLUSHINPAVEMENT5/8"FLUSHALUMINUMCAP"LS597"5/8"FLUSHINPAVEMNETGRAVELGRAVELPARKINGAREACONCRETEPADEXPOSEDFOUNDATIONMANHOLESIDEWALK SEWERLINESWATERLINEWSOUTHBURLINGTONCITYCLERK'SOFFICERECEIVEDFORRECORD______________________________________A.D.202_________at_____________O'clock____________minutes________mandrecordedinSlide__________________________________Attest:_____________________________________CityClerkTELEPHONEMANHOLE50'50'WIDEACCESSEASEMENTTOFARRELLSTREETPERv.649p.566&568EDGEOFGRAVELGRAVELPAVEMENTPAVEMENTFARRELLSTREETCITYLINE OFBURLINGTONCITYLINEOFSOUTHBURLINGTON APPROXIMATECITYLIMITSPERPLANS&PLATSOFRECORDAPPROVEDBYRESOLUTIONOFTHEDEVELOPMENTREVIEWBOARDOFTHECITYOFSOUTHBURLINGTON,VT.ONTHE______DAYOF________________________202___,SUBJECTTOTHEREQUIREMENTSANDCONDITIONSOFSAIDRESOLUTION.SIGNEDTHIS______DAYOF________________________202___,BY__________________________________________CHAIRMANORCLERK 510 SHELBURNE ROAD SOUTH BURLINGTON, VERMONT BACON ST. PROPERTIES, LLC Engineer: TRUDELL CONSULTING ENGINEERS (TCE) 478 BLAIR PARK ROAD WILLISTON, VT 05495 (802) 879-6331 Owner/Applicant: CHAMPLAIN OIL COMPANY & BACON ST. PROPERTIES, LLC C/O BRYAN CAIRNS 45 SAN REMO DRIVE SOUTH BURLINGTON, VT 05403 Architect: RABIDEAU ARCHITECTS 550 HINESBURG ROAD SUITE 101 SOUTH BURLINGTON, VT 05403 PROJECT DESCRIPTION: THE PURPOSE OF THIS PROJECT IS TO REDEVELOPE THIS FORMER GAS STATION SITE AND CONSTRUCT A MIXED USE RETAIL AND COMMERCIAL BUILDING AND ASSOCIATED SITE FEATURES. LOCAL PERMITTING SUBMISSION SET (NOT FOR CONSTRUCTION) 478 BLAIR PARK ROAD | WILLISTON, VERMONT 05495 802 879 6331 | WWW.TCEVT.COM TRUDELL CONSULTING ENGINEERS TCE PROJECT NO: 19-202 ---- ISSUED FOR CONSTRUCTIONLAST REVISED: USE AND INTERPRETATION OF THE DRAWINGS BEFORE USING THESE PLANS ENSURE THAT YOU HAVE THE LATEST REVISION 1. Unless otherwise noted, these Drawings are intended for preliminary planning, coordination with other disciplines or utilities, and/or approval from the regulatory authorities.  They are not intended as construction drawings unless noted as such or marked approved by a regulatory authority. 2. By use of these drawings for construction of the Project, the Owner represents that they have reviewed, approved, and accepted the drawings, obtained all necessary permits, and have met with all applicable parties/disciplines, including but not limited to, the Engineer and the Architect, to insure these plans are properly coordinated including, but not limited to, contract documents, specifications, owner/contractor agreements, building and mechanical plans, private and public utilities, and other pertinent permits for construction. 3. Owner and Architect are responsible for final design and location of buildings shown, including an area measured a minimum five (5) feet around any building and coordinating final utility connections shown on these plans. 4. Prior to using these plans for construction layout, the user shall contact TCE to ensure the plan contains the most current revisions. 5. These Drawings are specific to the Project and are not transferable. As instruments of service, these drawings, and copies thereof, furnished by TCE are its exclusive property.  Changes to the drawings may only be made by TCE. If errors or omissions are discovered, they shall be brought to the attention of TCE immediately. 6. It is the User's responsibility to ensure this copy contains the most current revisions. If unsure, please contact TCE. TAX ID: 1540-00510 No. 8917 CIVILP ROF ESSIONAL E N G INEERLICE N S E DJENNIFER ANN DESA UT ELSSTA TE O F VER M ONTCITY LIGHTS HADLEY ROAD BACON STREET PROPERTIES ROUTE 7 / SHELBURNE ROADF A R R E L L S T R E E T LARKIN RESIDENTIAL WALGREENS BACON STREET DRAWING INDEX Sheet Number Sheet Title --C0-00 COVER C1-00 LEGEND AND NOTES C1-01 EXISTING CONDITIONS PLAN C1-02 DEMOLITION, REMEDIATION, & EPSC PLAN C2-01 SITE PLAN C4-01 STORMWATER PLAN LA 2-01 LANDSCAPE PLAN LA 2-02 LANDSCAPE DETAILS LI 2-01 LIGHTING PLAN LI 2-02 LIGHTING DETAILS C8-01 SITE DETAILS C8-02 SANITARY DETAILS C8-03 SEWER & WATER DETAILS C8-04 EROSION DETAILS C8-05 STORMWATER & SITE DETAILS C8-06 STORMWATER DETAILS C8-07 EROSION, PREVENTION & SEDIMENT CONTROL LEGEND PROPOSEDEXISTING STREAM TRAIL PROPERTY LINE EASEMENTS SETBACKS WETLAND LIMIT FENCE TREE LINE CLEANOUT (CO) CATCH BASIN (CB) GUARD RAIL VALVE CURB STOP (CS) FIRE HYDRANT (HYD) WATER SUPPLY WELL END CAP BLOWOFF UTILITY POLE LUMINAIRE BOLLARD LIGHT IRON PIPE STEEL REBAR IRON PIN (IP) CALCULATED POINT SOIL BORING BENCHMARK CONCRETE MONUMENT STONEWALL OVERHEAD UTILITY SEWER FORCEMAIN STORM DRAINAGE CURTAIN DRAIN UNDERDRAIN ROOF DRAIN FOOTING DRAIN REMOVED/ABANDONED W PAVED DRIVE OR ROAD GRAVEL DRIVE OR ROAD TOPOGRAPHIC CONTOURS MONITOR WELL PERCOLATION TEST SOIL TEST PIT TO BE SETFOUND SET RECORD DRAWING REQUIREMENTS: 1.A CLEAN SET OF UP TO DATE RECORD DRAWINGS IS TO BE AVAILABLE FOR REVIEW ON SITE AT ALL TIMES. FOR JOBS LASTING MORE THAN 4 WEEKS A REVIEW OF THE RECORD DRAWINGS WILL BE DONE BY THE ENGINEER EVERY 2 WEEKS AND COMMENTS OR DEFICIENCIES MAY BE PROVIDED. 2.TIES TO ALL BENDS, VALVES, JOINTS, CONNECTIONS AND DESIGN FEATURES SHALL BE PROVIDED. TIES SHALL BE PULLED FROM EASILY LOCATABLE PERMANENT ABOVE GROUND FEATURES THAT ARE VISIBLE YEAR AROUND SUCH AS BUILDING CORNERS, HYDRANTS, SEWER AND STORM DRAIN COVERS THAT WILL BE CLEARED IN WINTER, UTILITY POLES, ETC. REFRAIN FROM PROVIDING TIES WITH ACUTE ANGLES. TIES SHOULD BE PULLED AT ANGLES AS CLOSE TO 90 DEGREES AS POSSIBLE. TIES WITH ANGLES TOO ACUTE MAY BE REJECTED. 3.RECORD INFORMATION NEEDS TO BE PROVIDED ON THE APPROPRIATE DESIGN PLANS ON A WEEKLY BASIS. RECORD INFORMATION REGARDING TCE DESIGN ITEMS PLACED ON INAPPROPRIATE DESIGN PLANS WILL NOT BE ACCEPTED. 4.TCE WILL ACCEPT ELECTRONIC RECORD COORDINATE INFORMATION, REFERENCED TO THE PROJECT DATUM. ELECTRONIC DATA SHALL BE COMPUTER-AIDED DESIGN (CAD) FILES INCLUDING NATIVE FILE FORMATS (DWG). 5.IF ENGINEERING SERVICES FOR BI-WEEKLY REVIEW OF RECORD INFORMATION HAVE NOT BEEN OBTAINED FOR THE PROJECT ALL RECORD INFORMATION FOR TCE DESIGN ITEMS SHALL BE PROVIDED TO TCE WITHIN 7 BUSINESS DAYS OF THE COMPLETION OF THE WORK. 6.PLANS SUBMITTED AT THE END OF THE PROJECT SHALL BE REVIEWED FOR COMPLETENESS. ALL REQUIREMENTS LISTED ABOVE APPLY. 7.IF DESIGN FEATURES WERE INSTALLED EXACTLY PER THE DESIGN PLANS TIES TO THE FEATURE ARE STILL REQUIRED TO BE PROVIDED BY THE CONTRACTOR FOR THE OWNERS USE. ANY FEATURE NOT INDICATED AS DIFFERENT IN RED WILL BE CONSIDERED TO BE EXACTLY PER DESIGN. 8.RECORD INFORMATION SHALL INCLUDE BOTH VERTICAL AND HORIZONTAL LOCATIONS. THIS INCLUDES BUT IS NOT LIMITED TO FINISHED FLOOR ELEVATIONS, RIMS AND INVERTS OF STRUCTURES AND PIPING, INVERTS AT CROSSINGS, ETC. 9.ANY UTILITIES ENCOUNTERED THAT ARE NOT SHOWN ON THE PLANS SHALL BE ADDED TO THE PLANS WITH APPROPRIATE TIES. 10.TIES SHALL INCLUDE ALL UTILITIES INSTALLED BY CONTRACTOR WHICH INCLUDE BUT ARE NOT LIMITED TO SEWER, WATER, STORM, ELECTRIC, CABLE, TELEPHONE, GAS, ETC. 11.RECORD DRAWINGS SHALL BE SUPPLIED ON BOTH HARD COPY AND ELECTRONIC DATA. ELECTRONIC DATA SHALL BE COMPUTER-AIDED DESIGN (CAD) FILES INCLUDING NATIVE FILE FORMATS (DWG). 12.THE CONTRACTOR SHALL SUBMIT ON A WEEKLY BASIS PROJECT PHOTOGRAPHS. THE INFORMATION WILL BE SUBMITTED TO THE ENGINEER IN ELECTRONIC FORMAT WITH EACH PICTURE BEING LABELED BY DATE, LOCATION AND ACTIVITY. AT A MINIMUM THE CONTRACTOR WILL SUBMIT PICTURES OF ALL THRUST BLOCKS, CONNECTIONS TO EXISTING FACILITIES AND STRUCTURES BEFORE AND AFTER BACKFILL. PROVIDE AUXILIARY LIGHTING AS REQUIRED TO PRODUCE CLEAR, WELL-LIT PHOTOGRAPHS WITHOUT OBSCURING SHADOWS. THE CONTRACTOR SHALL MAINTAIN ONE CHECK SET OF PHOTOGRAPHS AT THE SITE FOR REFERENCE. UPON REQUEST THE CONTRACTOR SHALL PROVIDE PICTURES OF VARIOUS AREAS DEEMED NECESSARY BY THE ENGINEER OR OWNER. 13.CERTIFICATIONS BY THE ENGINEER AND SUCCESSFUL TEST RESULTS DO NOT RELIEVE THE CONTRACTOR OF FULL COMPLIANCE WITH THE DESIGN PLANS, SPECIFICATIONS AND PERMITS SHOULD A DEFICIENCY BE DISCOVERED AFTER SAID CERTIFICATION OR TESTING. SPECIAL NOTE: FOR CLARITY, ALL ORIGINAL COLOR SHEETS MUST BE REPRODUCED IN COLOR CONSTRUCTION PHASE: LISTED BELOW IS A BRIEF SUMMARY OF CONSTRUCTION PHASE REQUIREMENTS. THIS LIST IS NOT INTENDED TO BE ALL-INCLUSIVE. CONSTRUCTION SPECIFICATIONS, PERMIT REQUIREMENTS AND SUBSEQUENT CONTRACTUAL AGREEMENTS FROM PARTIES INVOLVED SHALL PREVAIL. PRE-CONSTRUCTION ·OWNER TO ESTABLISH SCOPE OF SERVICES WITH PROJECT ENGINEER(S) ·OWNER TO IDENTIFY WORK SCOPE AND SCHEDULE ·UPON OWNER REQUEST, ENGINEER WILL ASSIST WITH CONTRACTOR BID AND SELECTION PROCESS ·ENGINEER TO FINALIZE PLANS FOR CONSTRUCTION READINESS INCLUDING SPECIFICATIONS ·MEETING BETWEEN OWNER, ENGINEER(S), CONTRACTOR(S), ARCHITECT(S), REGULATORY AUTHORITIES AND OTHER PERTINENT PARTIES TO REVIEW AND DISCUSS THE WORK PRE-CONSTRUCTION MEETING ·CONTRACTOR TO IDENTIFY SUPERINTENDENT WITH AUTHORITY TO MAKE DECISIONS ·CONTRACTOR TO IDENTIFY SUBCONTRACTORS ·CONTRACTOR TO ESTABLISH SCHEDULE ·CONTRACTOR TO DESIGNATE RESPONSIBLE PERSONNEL ·CONTRACTOR TO CONFIRM PROCEDURE FOR RFI'S, CHANGE ORDERS, EXTRAS AND PAY REQUESTS ·CONTRACTOR TO SUBMIT SHOP DRAWINGS ·CONTRACTOR TO OUTLINE SAFETY, SECURITY, AND WORKING HOURS ·CONTRACTOR OR OWNER TO IDENTIFY TESTING COMPANY CONSTRUCTION PHASE ·INITIAL CONTROL SUPPLIED BY OWNER AND CONTRACTOR RESPONSIBLE FOR LAYOUT ·PROJECT ENGINEER TO ESTABLISH BENCHMARK AND IN SOME CASES INITIAL SITE LAYOUT ·DISCUSS RESTRICTIONS SUCH AS, BUT NOT LIMITED TO, WETLANDS OR TREE LINE ·REVIEW EXISTING AND REQUIRED PERMITS ·DIGSAFE AND PERMIT NUMBER ·ADDITIONAL UNDERGROUND LAYOUT BY PRIVATE COMPANY ·DISCUSS EROSION CONTROL ·OWNER TO PROVIDE PROJECT ENGINEER TO OBSERVE CONSTRUCTION PERIODICALLY, DURING CRITICAL PHASES AND TESTING ·WEEKLY JOB MEETINGS DURING CONSTRUCTION ·OWNER TO PROVIDE PROJECT ENGINEER TO REVIEW AND DISCUSS PLANS, ANSWER QUESTIONS, RESPOND TO CHANGES, APPROVE SUBMITTALS, AND OTHER BUSINESS COMMON TO CONSTRUCTION SERVICES. ·ENGINEER TO OBSERVE TESTING AND COLLECT RESULTS ·OWNER AND CONTRACTOR TO COMPLY WITH PERMITS ·CONTRACTOR CERTIFICATION (PROVIDED BY CONTRACTOR) ·PICTURE AND RECORD DRAWINGS (PROVIDED BY CONTRACTOR) Sheet Title Project Title Use of These Drawings Scale: Project Number: Date: Drawn By: Project Engineer: Approved By: No. Description Date By Revisions 478 BLAIR PARK ROAD | WILLISTON, VERMONT 05495 802 879 6331 | WWW.TCEVT.COM ENGINEERING SURVEY No. 8917 CIVIL PROF ESSIONAL E N G INEERLICE N S E DJENNIFER ANN DESA U T ELSSTA TE O F VER M ONT Field Book: 1. Unless otherwise noted, these Drawings are intended for preliminary planning, coordination with other disciplines or utilities, and/or approval from the regulatory authorities.  They are not intended as construction drawings unless noted as such or marked approved by a regulatory authority. 2. By use of these drawings for construction of the Project, the Owner represents that they have reviewed, approved, and accepted the drawings, obtained all necessary permits, and have met with all applicable parties/disciplines, including but not limited to, the Engineer and the Architect, to insure these plans are properly coordinated including, but not limited to, contract documents, specifications, owner/contractor agreements, building and mechanical plans, private and public utilities, and other pertinent permits for construction. 3. Owner and Architect, are responsible for final design and location of buildings shown, including an area measured a minimum five (5) feet around any building and coordinating final utility connections shown on these plans. 4. Prior to using these plans for construction layout, the user shall contact TCE to ensure the plan contains the most current revisions. 5. These Drawings are specific to the Project and are not transferable. As instruments of service, these drawings, and copies thereof, furnished by TCE are its exclusive property.  Changes to the drawings may only be made by TCE. If errors or omissions are discovered, they shall be brought to the attention of TCE immediately. 6. It is the User's responsibility to ensure this copy contains the most current revisions. PLANNING ENVIRONMENTAL PAVED DRIVE OR ROAD WITH CURB SEWER MAINS AND SERVICES WATER MAINS AND SERVICES LIQUID PROPANE OR NATURAL GAS UNDERGROUND UTILITY MARBLE OR STONE MONUMENT TCE CONTROL POINT MAG NAIL TCE CONTROL POINT STEEL REBAR MTC OR TRANSFORMER OUTLET OR END SECTION ØØØØSSèèèè124 FM W CD UD RD FD G OH UG X 124 W D CD UD RD FD G OH UG X ØØØØØØS S S FM FM FM W W W W D D D D CD CD CD UD UD UD RD RD RD FD FD FD G G G G OH OH OH UG UG UG X X X X X X FM D W W CONSTRUCTION NOTES FOR CONTRACTOR & CLIENT/OWNER: 1.CONTRACT DOCUMENTS: THESE PLANS WERE PREPARED BY TRUDELL CONSULTING ENGINEERS (TCE) AND ARE INTENDED TO BE USED IN CONJUNCTION WITH THE STANDARD GENERAL CONDITIONS OF THE CONSTRUCTION CONTRACT, #C-700 PREPARED BY THE ENGINEERS JOINT CONTRACT DOCUMENTS COMMITTEE (EJCDC), LATEST EDITION. COPIES ARE AVAILABLE AT WWW.NSPE.ORG/EJCDC. 2.UNDERGROUND IMPROVEMENTS: THE LOCATION OF EXISTING UNDERGROUND UTILITIES AND IMPROVEMENTS SHOWN ARE ASSUMED BASED ON RESEARCH, UTILITY PLANS PROVIDED BY OTHERS, AND/OR SURFACE EVIDENCE AVAILABLE AND WERE OBTAINED IN A MANNER CONSISTENT WITH THE ORDINARY STANDARD OF PROFESSIONAL CARE AND HAVE NOT BEEN INDEPENDENTLY VERIFIED BY THE OWNER OR THE DESIGN ENGINEER. 3.DIFFERING SUBSURFACE OR PHYSICAL CONDITIONS: IF CONTRACTOR BELIEVES THAT ANY SUBSURFACE OR PHYSICAL CONDITION AT OR CONTIGUOUS TO THE SITE THAT IS UNCOVERED OR REVEALED EITHER: (1) IS OF SUCH A NATURE AS TO ESTABLISH THAT ANY “TECHNICAL DATA” ON WHICH CONTRACTOR RELIED IS MATERIALLY INACCURATE; OR (2) IS OF SUCH A NATURE AS TO REQUIRE A CHANGE IN THE PLANS/CONTRACT DOCUMENTS; OR (3) DIFFERS MATERIALLY FROM THAT SHOWN OR INDICATED IN THE PLANS/CONTRACT DOCUMENTS; OR (4) IS OF AN UNUSUAL NATURE, AND DIFFERS MATERIALLY FROM CONDITIONS ORDINARILY ENCOUNTERED AND GENERALLY RECOGNIZED AS INHERENT IN WORK OF THE CHARACTER PROVIDED FOR IN THE PLANS/CONTRACT DOCUMENTS; THEN CONTRACTOR SHALL, PROMPTLY AFTER BECOMING AWARE THEREOF AND BEFORE FURTHER DISTURBING THE SUBSURFACE OR PHYSICAL CONDITIONS OR PERFORMING ANY WORK IN CONNECTION THEREWITH (EXCEPT IN AN EMERGENCY), NOTIFY OWNER AND ENGINEER ABOUT SUCH CONDITION. CONTRACTOR SHALL NOT FURTHER DISTURB SUCH CONDITION OR PERFORM ANY WORK IN CONNECTION THEREWITH (EXCEPT AS AFORESAID) UNTIL RECEIPT OF WRITTEN ORDER TO DO SO. ALL PARTIES INVOLVED (OWNER, ENGINEER, ARCHITECT AND MUNICIPALITY IF APPLICABLE) SHALL AGREE UPON HOW TO PROCEED AND ANY RELATED COST IMPLICATIONS. 4.UTILITIES: PRIVATE AND PUBLIC UTILITIES SUCH AS ELECTRIC, TELEPHONE, GAS, CABLE, FIBER OPTIC ETC. ARE THE RESPONSIBILITY OF THE RESPECTIVE UTILITY COMPANY. ANY INFORMATION SHOWN BY TCE SHOULD BE CONSIDERED PRELIMINARY (USUALLY TO ASSIST WITH PERMITTING.) FINAL DESIGN, CONSTRUCTION AND MAINTENANCE ARE THE RESPONSIBILITY OF RESPECTIVE UTILITY COMPANIES. COMPLIANCE WITH EASEMENTS AND REGULATIONS (STATE AND LOCAL) ARE THE RESPONSIBILITY OF RESPECTIVE UTILITY COMPANY. 5.DIGSAFE: IN ACCORDANCE WITH VERMONT STATE LAW (VSA TITLE 30 CHAPTER 86 AND PSB RULE 3,800) THE CONTRACTOR SHALL BE RESPONSIBLE TO CONTACT DIGSAFE SYSTEMS, INC. “DIGSAFE.” AT LEAST 48 HOURS , EXCLUDING SATURDAYS, SUNDAYS, AND LEGAL HOLIDAYS, BUT NOT MORE THAN 30 DAYS BEFORE COMMENCING EXCAVATION ACTIVITIES, EXCEPT IN AN EMERGENCY. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PRE-MARKING THE SITE AND MAINTAINING DESIGNATED MARKINGS. FOR MORE INFORMATION ON DIGSAFE REQUIREMENTS SEE WWW.DIGSAFE.COM. 6.JOBSITE SAFETY: NEITHER THE PROFESSIONAL ACTIVITIES OF TRUDELL CONSULTING ENGINEERS (TCE), NOR THE PRESENCE OF TCE OR ITS EMPLOYEES AND SUB CONSULTANTS AT A CONSTRUCTION SITE, SHALL RELIEVE THE GENERAL CONTRACTOR AND ANY OTHER ENTITY OF THEIR OBLIGATIONS, DUTIES AND RESPONSIBILITIES INCLUDING, BUT NOT LIMITED TO, CONSTRUCTION MEANS, METHODS, SEQUENCE, TECHNIQUES OR PROCEDURES NECESSARY FOR PERFORMING, SUPERINTENDING OR COORDINATING ALL PORTIONS OF THE WORK OF CONSTRUCTION IN ACCORDANCE WITH THE CONTRACT DOCUMENTS AND ANY HEALTH OR SAFETY PRECAUTIONS REQUIRED BY ANY REGULATORY AGENCIES. TCE AND ITS PERSONNEL HAVE NO AUTHORITY TO EXERCISE ANY CONTROL OVER ANY CONSTRUCTION CONTRACTOR OR OTHER ENTITY OR THEIR EMPLOYEES IN CONNECTION WITH THEIR WORK OR ANY HEALTH OR SAFETY PRECAUTIONS. THE CLIENT AGREES THAT THE GENERAL CONTRACTOR IS SOLELY RESPONSIBLE FOR JOBSITE SAFETY, AND WARRANTS THAT THIS INTENT SHALL BE MADE EVIDENT IN THE CLIENT'S AGREEMENT WITH THE GENERAL CONTRACTOR. THE CLIENT ALSO AGREES THAT THE CLIENT, TCE AND TCE'S CONSULTANTS SHALL BE INDEMNIFIED AND SHALL BE MADE ADDITIONALLY INSURED UNDER THE GENERAL CONTRACTOR'S GENERAL LIABILITY INSURANCE POLICY. 7.CODES AND STANDARDS COMPLIANCE: TCE SHALL EXERCISE USUAL AND CUSTOMARY PROFESSIONAL CARE IN ITS EFFORTS TO COMPLY WITH CODES, STANDARDS, REGULATIONS AND ORDINANCES IN EFFECT. THE OWNER ACKNOWLEDGES THAT SUCH REQUIREMENTS MAY BE SUBJECT TO VARIOUS AND CONTRADICTORY INTERPRETATIONS. TCE, THEREFORE, WILL USE ITS REASONABLE PROFESSIONAL EFFORTS AND JUDGMENT TO INTERPRET APPLICABLE REQUIREMENTS AS THEY APPLY TO THE PROJECT. TCE, HOWEVER, CANNOT AND DOES NOT WARRANT OR GUARANTEE THAT THE PROJECT WILL COMPLY WITH ALL INTERPRETATIONS OF SUCH REQUIREMENTS. 8.CONSTRUCTION OBSERVATION: TCE MAY VISIT THE PROJECT AT APPROPRIATE INTERVALS DURING CONSTRUCTION TO BECOME GENERALLY FAMILIAR WITH THE PROGRESS AND QUALITY OF THE CONTRACTOR'S WORK AND TO DETERMINE IF THE WORK IS PROCEEDING IN GENERAL ACCORDANCE WITH THE CONTRACT DOCUMENTS. THE OWNER HAS NOT RETAINED TCE TO MAKE DETAILED INSPECTIONS OR TO PROVIDE EXHAUSTIVE OR CONTINUOUS PROJECT REVIEW AND OBSERVATION SERVICES. TCE DOES NOT GUARANTEE THE PERFORMANCE OF, AND SHALL NOT HAVE RESPONSIBILITY FOR, THE ACTS OR OMISSIONS OF ANY CONTRACTOR, SUB-CONTRACTOR, SUPPLIER OR ANY OTHER ENTITY FURNISHING MATERIALS OR PERFORMING ANY WORK ON THE PROJECT. TCE SHALL NOT SUPERVISE, DIRECT OR HAVE CONTROL OVER THE CONTRACTOR'S WORK NOR HAVE ANY RESPONSIBILITY FOR THE CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES OF THE CONTRACTOR. IF THE OWNER DESIRES MORE EXTENSIVE PROJECT OBSERVATION OR FULL-TIME PROJECT REPRESENTATION, THE OWNER SHALL REQUEST SUCH SERVICES BE PROVIDED BY TCE AS ADDITIONAL SERVICES. 9.THE CONTRACTOR SHALL REPAIR/RESTORE ALL DISTURBED AREAS (ON OR OFF THE SITE) AS A DIRECT OR INDIRECT RESULT OF THE CONSTRUCTION. ALL GRASSED AREAS SHALL BE MAINTAINED UNTIL FULL VEGETATION IS ESTABLISHED. MAINTAIN ALL TREES OUTSIDE OF CONSTRUCTION LIMITS. 10.IN ADDITION TO THE REQUIREMENTS SET IN THESE PLANS AND SPECIFICATIONS, THE CONTRACTOR SHALL COMPLETE THE WORK IN ACCORDANCE WITH ALL PERMIT CONDITIONS, LOCAL PUBLIC WORKS STANDARDS AND ALL CONSTRUCTION SAFETY REGULATIONS. 11.ANY DEWATERING NECESSARY FOR THE COMPLETION OF THE SITEWORK SHALL BE CONSIDERED AS PART OF THE CONTRACT AND SHALL BE THE CONTRACTOR'S RESPONSIBILITY. 12.IF THERE ARE ANY CONFLICTS OR INCONSISTENCIES WITH THE PLANS OR SPECIFICATIONS, THE CONTRACTOR SHALL CONTACT THE ENGINEER FOR VERIFICATION BEFORE WORK CONTINUES ON THE ITEM(S) IN QUESTION. 13.SEWER LATERAL CONNECTIONS ARE SOMETIMES NOT SHOWN FOR CLARITY. CONTRACTOR TO CONSULT WITH ENGINEER AND SUPPLY BENDS, CLEANOUTS, ETC. AS NECESSARY TO FACILITATE PROPER CONNECTION BETWEEN FOUNDATION WALL AND SEWER MAIN LINE. 14.CONTRACTOR IS RESPONSIBLE FOR COORDINATION WITH ALL RELEVANT PARTIES (INCLUDING, BUT NOT LIMITED TO OWNER, ARCHITECT AND UTILITY COMPANIES) TO DETERMINE FINAL LAYOUT AND DESIGN. 15.DESIGN AND CONSTRUCTION OF PEDESTRIAN WALKS, RAMPS AND DECKS BETWEEN BUILDINGS AND PARKING LOTS IS PROVIDED BY THE ARCHITECT AND INCORPORATED INTO THE BUILDING DESIGN, UNLESS INDICATED OTHERWISE. 16.ALL WATER LINE TAPS SHALL BE LIVE TAPS; EXISTING WATER LINE MUST REMAIN IN SERVICE DURING CONNECTION, UNLESS INDICATED OTHERWISE. 17.ROOF DOWNSPOUT CAN CONNECT TO ROOF DRAIN MANIFOLD (RD) AS DETERMINED BY ARCHITECT AND OWNER. THIS CONNECTION PIPE IS INCLUDED AS PART OF THE DESIGN PLAN BUT NOT SHOWN TO ALLOW FLEXIBILITY IN LOCATION AS NEEDED. 18.THRUST BLOCKS FOR PRESSURE LINES ARE NOT SHOWN FOR CLARITY PURPOSES. PROVIDE THRUST BLOCKS AT ALL BENDS, TEE AND REDUCES. PROJECT ENGINEER TO OBSERVE ALL THRUST BLOCKS PRIOR TO BACKFILL. 19.WATER MAIN OPERATED AT HIGH PRESSURE. ALL BUILDINGS SHALL CONFIRM STATIC INTAKE PRESSURE AND PROVIDE PRESSURE-REDUCING VALVES AS DEEMED APPROPRIATE BY THE MECHANICAL ENGINEER (OR ARCHITECT.) 20.CONTRACTOR TO SUPPLY DAYLIGHT PIPING FOR FOOTING DRAINS WITHIN CONSTRUCTION LIMITS. THE EXACT LOCATION MAY NOT BE CRITICAL. COORDINATE WITH OWNER AND PROJECT ENGINEER. 21.FOOTING DRAINS AROUND BUILDING MAY BE SHOWN BY OTHERS (BECAUSE IT IS WITHIN THE 5' ZONE AROUND BUILDING). FOOTING DRAINS AND PIPE TO DAYLIGHT SHALL BE INCLUDED EVEN IF NOT SHOWN. DAYLIGHT PIPE LOCATION TO SWALE MAY NOT BE CRITICAL SO LONG AS IT DOES NOT CREATE ANY CONFLICT WITH OTHER UTILITIES, OR IMPACT ENVIRONMENTALLY SENSITIVE AREAS SUCH AS WETLANDS. 22.SEWER CONNECTIONS TO EXISTING MANHOLES SHALL INCLUDE WATERTIGHT CONNECTIONS, REFORMING INVERT TO PROVIDE SMOOTH FLOW STREAM AND TESTING TO ENSURE STRUCTURE IS WATERTIGHT. IF AN EXISTING MANHOLE IS FOUND NOT TO BE WATERTIGHT IT SHALL BE EXPOSED AND REPAIRED ON THE OUTSIDE. PRIOR TO CONNECTING TO EXISTING MANHOLES, SUBMIT SHOP DRAWINGS ON CORE LOCATION, ANY REQUIRED PIPING (FOR DROP MANHOLES) AND CHANGES TO INVERT FORM. 23.FINAL RIMS OF SEWER MANHOLES AND WATER VALVES SHALL BE CONFIRMED AND COORDINATED WITH FINAL SITE GRADING. MINOR ADJUSTMENTS FROM DESIGN GRADES MAY BE REQUIRED BY OWNER OR ENGINEER AND SHALL BE INCLUDED. 24.ROCK REMOVAL WORK FOR BOULDERS UNDER 2.5 CUBIC YARDS IS INCLUDED AS PART OF EXCAVATION. ANY ROCK REMOVAL FOR 2.5 CUBIC YARDS OR GREATER SHALL BE TREATED AS LEDGE REMOVAL. THIS SHOULD BE REVIEWED AND AGREED UPON BY OWNER PRIOR TO CONDUCTING ROCK REMOVAL. 25.THE GENERAL CONTRACTOR IS REQUIRED TO CONFORM TO THE STRICTEST INTERPRETATION OF THE CONTRACT DRAWING, SPECIFICATION, PERMITS AND CONSTRUCTION CONTRACT. ALL EARTH MATERIAL RECEIVED OR DISPOSED FROM OUTSIDE SOURCES SHALL COMPLY WITH APPLICABLE PERMITS AND REGULATIONS. SHOP DRAWING SUBMITTALS SHALL INCLUDE CONTRACTOR'S CERTIFICATION STATEMENT OF COMPLIANCE AND COPIES OF RELEVANT PERMITS FOR OUTSIDE SOURCES. 26.CONTRACTOR SHALL PAY FOR ALL REQUIRED TESTING. THIS SHALL INCLUDE BUT IS NOT LIMITED TO: SOIL TESTING, COMPACTION TESTING, SIEVE ANALYSIS, CONCRETE TESTING, ASPHALT PENETRATION TESTING, BACTERIOLOGICAL TESTING FOR WATER AND OTHER TESTING AS PART OF STANDARD PRACTICE FOR A CONSTRUCTION PROJECT OF THIS NATURE, UNLESS INDICATED OTHERWISE AND APPROVED BY THE OWNER. Legend and Notes C1-00 06/04/2020 N/A 19-202 RMP JAD    348 Bacon St. Properties, LLC 510 Shelburne Road South Burlington, Vermont LEGEND NOTE: SOME INFORMATION MAY BE PROVIDED BY OTHERS AND COULD BE SHOWN WITH A DIFFERENT SYMBOL NOT SHOWN ON THIS LEGEND. HOWEVER, THEY ARE LABELED ON RESPECTIVE PLANS. IN SOME CASES A CHANGE IN SCALE OR PRINTER CAN ALTER INFORMATION TO NOT SHOW AN EXACT MATCH ON THIS LEGEND. IF ANY QUESTIONS EXIST CONTACT THE ENGINEER TO CLARIFY. ADDITIONAL LEGEND INFORMATION IS SUPPLIED SEPARATELY ON EROSION CONTROL PLANS AND SOME SURVEY PLATS.   TAX ID: 1540-00510 SEWER, STORM OR TELEPHONE MANHOLE (SMH/STMH/TMH) TELEPHONE OR TELEVISION PEDESTAL (TEL-PED/TV-PED) ADJOINING PROPERTY LINE WELL CONE / WASTEWATER CONE OF INFLUENCE SIGN VFSL xx"/xx" TP- P- XXMIN./IN. SURVEY FDFDFD OHOHOHOHOHOHOH OH OH OH OH OH OHUG UGUGUGUGUGUG GGG W W W W W W W SSSStax map no. 1540-00520 Germania Property Group, LLC v. 975 p. 135 map slide 548, 555, 589 tax map no. 0090-00025 John Larkin, INC v. 1375 p. 324 map slides 548, 555, 589, 600 tax map no. 0090-00014 Deimer Properties, INC. v. 479 p. 704 map slide 67 BACON STREET U.S. ROUTE 7 & SHELBURNE ROADGRAVEL GRAVEL GRAVEL PARKING AREA CONCRETE PAD EXPOSED FOUNDATION EXISTING SIDEWALKMW MW MW 18" WHITE PINE S S S "BACON STREET" SIGN "STOP" SIGN 4" CAST IRON CLEANOUTS15" CLAY10" CLAY SMH R=207.75 iOUT=201.7 (15")N iIN=201.8 (10")E CONCRETE MW MW MW MW ELEC. METER SERVICE GRAVEL PAVEMENT GRAVEL FFE=210.88 FFE=211.44 FLUSH CURB PAVEMENT PAVEMENT PAVEMENT DMH R=210.29 iOUT=205.4± (10" PVC)N iIN=205.4± (18" HDPE)E SUMP @ 204.45 D DDTELEPHONE PEDESTAL CB R=209.74 iIN=205.74 (15" HDPE)E iIN=205.72 (18" HDPE)S iOUT=205.59 (18" HDPE)W SUMP @ 204.2 CB R=209.97 i=207.77 (12" CMP) SUMP @ 206.37 CB R=210.55 iOUT=206.25 (20" HDPE) SUMP @ 205.45 D D 4" PVC CLEANOUT R=210.45 i=204.5 12" CMP18" HDPE10" PVC20" HDPE 6" HDPE 6" HDPE SMH R=210.39 iIN=203.47 (4" PVC)N iIN=203.4E iIN=203.4±S iOUT=203.37 (10" PVC)W4" PVC10" PVC CB R=208.93 iIN=206.53 (8" PVC)S iOUT=206.53 (8" PVC)W SUMP @ 205.38 8" PVC8" PVC CB R=208.78 i=206.93 (8" PVC) SUMP @ 205.9 SMH R=209.48 iIN=202.11 (10" PVC)E iIN=202.13 (8" PVC)N iOUT=202.08 (10" PVC)WS8" PVCSMH R=209.91 DMH R=211.87 SMH R=211.60 CB R=210.29 CB R=207.01 i=204.51 (6") SUMP @ 204.0 CURB STOP (BROKEN)CB R=209.75 i=206.75 (6" HDPE) SUMP @ 206.6 UG UG APPROXIMATE LOCATION OF UNDERGROUND STORM SEWER BASED ON CITY OF BURLINGTON MAPPING - NOT FIELD VERIFIED W10" PVC 15 " H D P E 18" HDPE 50' WIDE ACCESS EASEMENT TO FARRELL STREET 211 211 209208208209 211 211 211 212 212211210210 210 210 210 210210PROJECT TBM TOP NORTH B.BOLT "X" ELEV.=212.11 BOUNDARY LINE TO BE DISSOLVEDPOLE 16-30 34308 THREE PHASE POLE 15 34306 SINGLE PHASE POLE 13 102378 POLE 1 34309 THREE PHASE UGW OHOHD D D D DDDDDDDAPPROXIMATE LOCATION OF UNDERGROUND STORM SEWER BASED ON CITY OF BURLINGTON MAPPING - NOT FIELD VERIFIED 6" WATER MAIN GRAVEL 21 0 209209 CB R=207.32 (4) 3" BIRCHES 4" BALSAM FIR 4" SPRUCE 4" BALSAM FIR 6" 6" MAPLE 3 BUSHES (4) 3" BIRCHES 4" BALSAM FIR 4" BALSAM FIR (4) 3" BIRCHES (4) 3" BIRCHES (4) 2" BIRCHES 4" SPRUCE 6" MAPLE TELEPHONE MANHOLE SUMP @ 199.16 APPROX. LOCATION EXISTING FLOOR DRAIN Sheet Title Project Title Use of These Drawings Scale: Project Number: Date: Drawn By: Project Engineer: Approved By: No. Description Date By Revisions 478 BLAIR PARK ROAD | WILLISTON, VERMONT 05495 802 879 6331 | WWW.TCEVT.COM ENGINEERING SURVEY No. 8917 CIVIL PROF ESSIONAL E N G INEERLICE N S E DJENNIFER ANN DESA U T ELSSTA TE O F VER M ONT Field Book: 1. Unless otherwise noted, these Drawings are intended for preliminary planning, coordination with other disciplines or utilities, and/or approval from the regulatory authorities.  They are not intended as construction drawings unless noted as such or marked approved by a regulatory authority. 2. By use of these drawings for construction of the Project, the Owner represents that they have reviewed, approved, and accepted the drawings, obtained all necessary permits, and have met with all applicable parties/disciplines, including but not limited to, the Engineer and the Architect, to insure these plans are properly coordinated including, but not limited to, contract documents, specifications, owner/contractor agreements, building and mechanical plans, private and public utilities, and other pertinent permits for construction. 3. Owner and Architect, are responsible for final design and location of buildings shown, including an area measured a minimum five (5) feet around any building and coordinating final utility connections shown on these plans. 4. Prior to using these plans for construction layout, the user shall contact TCE to ensure the plan contains the most current revisions. 5. These Drawings are specific to the Project and are not transferable. As instruments of service, these drawings, and copies thereof, furnished by TCE are its exclusive property.  Changes to the drawings may only be made by TCE. If errors or omissions are discovered, they shall be brought to the attention of TCE immediately. 6. It is the User's responsibility to ensure this copy contains the most current revisions. PLANNING ENVIRONMENTAL 0 Feet Graphic Scale 20 20 40 60 80 15°±VT GridMagneticTAX ID: 1540-00510 Existing Conditions Plan C1-01 02/24/2020 1" = 20' 19-202 RMP JAD    348 Bacon St. Properties, LLC 510 Shelburne Road South Burlington, Vermont EXISTING CONDITIONS NOTES: 1.THE PURPOSE OF THE EXISTING CONDITIONS PLAN IS TO DEPICT READILY APPARENT PERTINENT EXISTING CONDITIONS AS OF 09/12/2019 AND 04/27/2020. 2.BEARINGS SHOWN ARE BASED UPON VERMONT GRID NORTH. 3.VERTICAL DATUM IS BASED ON NAVD88 (GEIOD 12). A RTK WAS EMPLOYED FOR THESE OBSERVATIONS FROM VERMONT CORS STATION VTVRS. 4.COORDINATE SYSTEM IS BASED ON VERMONT STATE PLANE (U.S. SURVEY FEET). 5.THE LOCATION OF EXISTING UNDERGROUND UTILITIES AND IMPROVEMENTS SHOWN ARE BASED ON RESEARCH, UTILITY PLANS PROVIDED BY OTHERS, AND/OR SURFACE EVIDENCE ENCOUNTERED AND WERE OBTAINED IN A MANNER CONSISTENT WITH THE ORDINARY STANDARD OF PROFESSIONAL CARE AND HAVE NOT BEEN INDEPENDENTLY VERIFIED BY THE OWNER OR THE DESIGN ENGINEER. ADDITIONAL UTILITIES NOT SHOWN MAY EXIST. ENGINEER SHALL BE NOTIFIED IF ANY DISCREPANCIES ARE ENCOUNTERED. ACTUAL LOCATION OF UNDERGROUND UTILITIES MAY VARY. DIGSAFE MUST BE CONTACTED PRIOR TO ANY EXCAVATION. CALL 1-888-DIG SAFE (344-7233). 6. 7.PERIMETER BOUNDARIES SHOWN HEREON BASED ON A BOUNDARY PLAT FOR CHAMPLAIN OIL COMPANY, INC. & BACON STREET PROPERTIES, LLC. DATED 09/13/2019. PROJECT LOCATION1 1 2 2 3 4 3 4 5 5 6 6 7 7 8 8 9 9 10 10 FDFDFDFDFD FDOHOHOHOHOHOHOHOHOHOHOHOHOHOHOH OH OH OH OH OH OH OH OH OH OH OH OH OHUGUG GGGGGWG G G W W W W W W W W W W W W W W SSSSSSSSStax map no. 1540-00520 Germania Property Group, LLC v. 975 p. 135 map slide 548, 555, 589 John Larkin, INC v. 1375 p. 324 map slides 548, 555, tax map no. 0090-00014 Deimer Properties, INC. v. 479 p. 704 map slide 67 BACON STREET U.S. ROUTE 7 & SHELBURNE ROADGRAVEL GRAVEL GRAVEL PARKING AREA CONCRETE PAD EXPOSED FOUNDATION EXISTING SIDEWALKMW MW MW S S S S S S "BACON STREET" SIGN "STOP" SIGN 4" CAST IRON CLEANOUTSS15" CLAY10" CLAY D WSMH R=207.75 iOUT=201.7 (15")N iIN=201.8 (10")E CONCRETE MW MW MW MW ELEC. METER SERVICE GRAVEL PAVEMENT GRAVEL FFE=210.88 FFE=211.44 FLUSH CURB PAVEMENT PAVEMENT PAVEMENT DMH R=210.29 iOUT=205.4± (10" PVC)N iIN=205.4± (18" HDPE)E SUMP @ 204.45 D D DCB R=209.74 iIN=205.74 (15" HDPE)E iIN=205.72 (18" HDPE)S iOUT=205.59 (18" HDPE)W SUMP @ 204.2 CB R=210.55 iOUT=206.25 (20" HDPE) SUMP @ 205.45 D 4" PVC CLEANOUT R=210.45 i=204.5 10" PVC6" HDPE 6" HDPE SMH R=210.39 iIN=203.47 (4" PVC)N iIN=203.4E iIN=203.4±S iOUT=203.37 (10" PVC)W 4" PVCS10" PVCDD CB R=208.93 iIN=206.53 (8" PVC)S iOUT=206.53 (8" PVC)W SUMP @ 205.38 8" PVC8" PVC CB R=208.78 i=206.93 (8" PVC) SUMP @ 205.9 SMH R=209.48 iIN=202.11 (10" PVC)E iIN=202.13 (8" PVC)N iOUT=202.08 (10" PVC)WSSS8" PVCR=209.91 DMH R=211.87 SMH R=211.60 CB R=207.01 i=204.51 (6") SUMP @ 204.0 CURB STOP (BROKEN) CB R=209.75 i=206.75 (6" HDPE) SUMP @ 206.6 UG UG UG UG UG WWWWWWWWWWWWW10" PVC 15 " H D P E 18" HDPE 50' WIDE ACCESS EASEMENT TO FARRELL STREET 211211 209208208209 211 211 211 212210210 210 210 210 210210PROJECT TBM TOP NORTH B.BOLT "X" ELEV.=212.11 BOUNDARY LINE TO BEDISSOLVEDPOLE 16-30 34308 THREE PHASE POLE 15 34306 SINGLE PHASE POLE 1 34309 THREE PHASE WWD D D D D D D D DDDDDDDDDDDDDDDAPPROXIMATE LOCATION OF UNDERGROUND STORM SEWER BASED ON CITY OF BURLINGTON MAPPING - NOT FIELD VERIFIED 6" WATER MAIN CHAINLINK CONSTRUCTION FENCE SCESTABILIZED CONSTRUCTION ENTRANCE ALL GRAVEL AND PAVEMENT SURFACING TO BE REMOVED TO BE REMOVED TO BE REMOVED TO BE REMOVED TO BE REMOVED TO BE REMOVED TO BE REMOVED TO BE REMOVED TO BE REMOVED TO BE REMOVED TO BE REMOVED TO BE REMOVED TO BE REMOVED TO BE REMOVED GRAVEL TO BE REMOVED TO BE REMOVED TO BE REMOVED EXISTING BUILDING, CURBING, & ASSOCIATED STRUCTURE TO BE REMOVED EXISTING UNDERGROUND WATER AND POWER TO BE CUT/CAPPED & ABANDONED 21 0 209209 TO BE REMOVED(4) 3" BIRCHES 4" BALSAM FIR TO BE REMOVED TO BE REMOVED TELEPHONE MANHOLE SUMP @ 199.16 APPROX. LOCATION EXISTING FLOOR DRAIN TO BE REMOVED TO BE REMOVED TO BE REMOVED TO BE REMOVED TO BE REMOVED TO BE REMOVED TO BE REMOVED TO BE REMOVED Sheet Title Project Title Use of These Drawings Scale: Project Number: Date: Drawn By: Project Engineer: Approved By: No. Description Date By Revisions 478 BLAIR PARK ROAD | WILLISTON, VERMONT 05495 802 879 6331 | WWW.TCEVT.COM ENGINEERING SURVEY No. 8917 CIVIL PROF ESSIONAL E N G INEERLICE N S E DJENNIFER ANN DESA U T ELSSTA TE O F VER M ONT Field Book: 1. Unless otherwise noted, these Drawings are intended for preliminary planning, coordination with other disciplines or utilities, and/or approval from the regulatory authorities.  They are not intended as construction drawings unless noted as such or marked approved by a regulatory authority. 2. By use of these drawings for construction of the Project, the Owner represents that they have reviewed, approved, and accepted the drawings, obtained all necessary permits, and have met with all applicable parties/disciplines, including but not limited to, the Engineer and the Architect, to insure these plans are properly coordinated including, but not limited to, contract documents, specifications, owner/contractor agreements, building and mechanical plans, private and public utilities, and other pertinent permits for construction. 3. Owner and Architect, are responsible for final design and location of buildings shown, including an area measured a minimum five (5) feet around any building and coordinating final utility connections shown on these plans. 4. Prior to using these plans for construction layout, the user shall contact TCE to ensure the plan contains the most current revisions. 5. These Drawings are specific to the Project and are not transferable. As instruments of service, these drawings, and copies thereof, furnished by TCE are its exclusive property.  Changes to the drawings may only be made by TCE. If errors or omissions are discovered, they shall be brought to the attention of TCE immediately. 6. It is the User's responsibility to ensure this copy contains the most current revisions. PLANNING ENVIRONMENTAL 0 Feet Graphic Scale 10 10 20 30 40 15°±VT GridMagneticTAX ID: 1540-00510 Demolition, Remediation, & EPSC Plan C1-02 06/04/2020 RMP 19-202 rmp JAD    348 Bacon St. Properties, LLC 510 Shelburne Road South Burlington, Vermont NOTE: 1.CONTRACTOR TO ABIDE BY REGULATIONS REGARDING CONTAMINATED SOILS FROM PRIOR SITE USE. REFER TO KAS CONSULTING FOR ENVIRONMENTAL/SOILS REMEDIATION PLAN. CORRECTIVE ACTION PLAN (CAP) AND SHORT AND LONG TERM SOILS MONITORING TO BE APPROVED BY THE VERMONT DEPARTMENT OF ENVIRONMENTAL CONSERVATION. OHOHOHOHOHOHOHOHOHOHOHOHOHOHOH OH OH OH OH OH OH OH OH OH OH OH OH OHUGUG GGGGGWG G G W W W W W W W W W W W W W W SSSSSSSSStax map no. 1540-00520 Germania Property Group, LLC v. 975 p. 135 map slide 548, 555, 589 John Larkin, INC v. 1375 p. 324 map slides 548, 555, tax map no. 0090-00014 Deimer Properties, INC. v. 479 p. 704 map slide 67 S S S S S S "BACON STREET" SIGN "STOP" SIGNS15" CLAY10" CLAY D WSMH R=207.75 iOUT=201.7 (15")N iIN=201.8 (10")E DMH R=210.29 iOUT=205.4± (10" PVC)N iIN=205.4± (18" HDPE)E SUMP @ 204.45 D D DCB R=209.74 iIN=205.74 (15" HDPE)E iIN=205.72 (18" HDPE)S iOUT=205.59 (18" HDPE)W SUMP @ 204.2 CB R=210.55 iOUT=206.25 (20" HDPE) SUMP @ 205.45 D 10" PVC6" HDPE 6" HDPE SMH R=210.39 iIN=203.47 (4" PVC)N iIN=203.4E iIN=203.4±S iOUT=203.37 (10" PVC)W 4" PVCS10" PVCDD CB R=208.93 iIN=206.53 (8" PVC)S iOUT=206.53 (8" PVC)W SUMP @ 205.38 8" PVC8" PVC CB R=208.78 i=206.93 (8" PVC) SUMP @ 205.9 SMH R=209.48 iIN=202.11 (10" PVC)E iIN=202.13 (8" PVC)N iOUT=202.08 (10" PVC)WSSS8" PVCR=209.91 DMH R=211.87 SMH R=211.60 CB R=207.01 i=204.51 (6") SUMP @ 204.0 CB R=209.75 i=206.75 (6" HDPE) SUMP @ 206.6 10" PVC 15 " H D P E 18" HDPE 50' WIDE ACCESS EASEMENT TO FARRELL STREET209208208 209 211 211 211 212210210 210 210 210 210210PROJECT TBM TOP NORTH B.BOLT "X" ELEV.=212.11 POLE 16-30 34308 THREE PHASE POLE 15 34306 SINGLE PHASE POLE 1 34309 THREE PHASE WWD D D D D D D D DDDDDDDDDDDDDDDAPPROXIMATE LOCATION OF UNDERGROUND STORM SEWER BASED ON CITY OF BURLINGTON MAPPING - NOT FIELD VERIFIED 6" WATER MAIN 21 0 209209 TELEPHONE MANHOLE SUMP @ 199.16 211.65 8 9 5 3 10'SETBACK20' SETBACK 10'SETBACK30' SETBACK20'SETBACKPROPOSED "DO NOT ENTER" SIGN OFF-SITE PARALLEL PARKING D18' CONCRETE CURB TC 211.30 BC 210.80 TC 211.45 BC 210.95 TC 211.73 BC 211.23 FLUSH CURB TC 211.73 BC 211.23WWWW 1000 GALLON HEAVY DUTY GREASE TRAP 6" iIN = 206.0 6"iOUT = 205.75 UG UG UG FLUSH CURB FLUSH CURB CONCRETE CURB DETECTABLE WARNING (TYPICAL) BACON STREET U.S. ROUTE 7 / SHELBURNE ROADOUTDOOR SEATING & PATIO SLIP LANE PROPOSED SIDEWALKPROPOSED SIDEWALK PROPOSEDSIDEWALK211.40 3.75% 2% 210.35 211.50 211.85 2% 2% 1% 1.5% 211.85 1.5%4" C900 WATER LINENEW 3 PHASE TRANSFORMER 211.60 211.1 211.90 PROPOSED BUILDING 4,930 SF FINISHED FLOOR ELEVATION = 211.90DDDDDD D D RDRDRDD D D D D D D D D D D D D D D D6" SDR35 SEWER S = 14"/FT6" BLD iOUT = 207.5 6" iIN = 202.2 5 DDDDDSIDEWALK TO MEET EXISTING GRADE ±3% ±1.6% 211.85 211.85 1.5% ±1.6% TC 211.73 BC 211.23 211.85 211.90 211.90 211.85 211.65 211.85 2% 211.50 209.50 210.40 8 1% 210.40 210.40 209 210211 211 211 21121 1211210210 210 210 10' SETBACK 210209 2 1 1 13'211 ++++++++++++++++++++++++++++++++++++++++++ SNOW STORAGE (TYPICAL) PROPOSED DUMPSTER ON 8.5' x 12' CONCRETE PAD WITH SCREEN FENCING SSSSSSSSSSSSSS S S S CO D RDRDRDRDRDRDRDRDRD211DDDD49.21'101.21'FLUSH CURB PROPOSED SMH 6" iIN = 205.35 6" iOUT = 205.25 20" HIGH SEAT WALL WITH CAP 3 BIKE RACKS 210.30 210.30 PROPOSED LIGHTED BOLLARD (TYPICAL) HELIO M30/K4 SECURITY BOLLARD, SERIES 900, NON-ILLUMINATED (TYPICAL) UD UD UDUDUD210 0 Feet Graphic Scale 10 10 20 15°±VT GridMagneticSheet Title Project Title Use of These Drawings Scale: Project Number: Date: Drawn By: Project Engineer: Approved By: No. Description Date By Revisions 478 BLAIR PARK ROAD | WILLISTON, VERMONT 05495 802 879 6331 | WWW.TCEVT.COM ENGINEERING SURVEY No. 8917 CIVIL PROF ESSIONAL E N G INEERLICE N S E DJENNIFER ANN DESA U T ELSSTA TE O F VER M ONT Field Book: 1. Unless otherwise noted, these Drawings are intended for preliminary planning, coordination with other disciplines or utilities, and/or approval from the regulatory authorities.  They are not intended as construction drawings unless noted as such or marked approved by a regulatory authority. 2. By use of these drawings for construction of the Project, the Owner represents that they have reviewed, approved, and accepted the drawings, obtained all necessary permits, and have met with all applicable parties/disciplines, including but not limited to, the Engineer and the Architect, to insure these plans are properly coordinated including, but not limited to, contract documents, specifications, owner/contractor agreements, building and mechanical plans, private and public utilities, and other pertinent permits for construction. 3. Owner and Architect, are responsible for final design and location of buildings shown, including an area measured a minimum five (5) feet around any building and coordinating final utility connections shown on these plans. 4. Prior to using these plans for construction layout, the user shall contact TCE to ensure the plan contains the most current revisions. 5. These Drawings are specific to the Project and are not transferable. As instruments of service, these drawings, and copies thereof, furnished by TCE are its exclusive property.  Changes to the drawings may only be made by TCE. If errors or omissions are discovered, they shall be brought to the attention of TCE immediately. 6. It is the User's responsibility to ensure this copy contains the most current revisions. PLANNING ENVIRONMENTAL TAX ID: 1540-00510 Site Plan C2-01 06/04/2020 1" = 10' 19-202 RMP JAD    348 Bacon St. Properties, LLC 510 Shelburne Road South Burlington, Vermont ZONING DISTRICT INFORMATION: ZONING DISTRICT:C1 R15 OVERLAY DISTRICT:URBAN DESIGN (UDO)/PRIMARY NODE TRANSIT DISTRICT TRAFFIC DISTRICT / ZONE 1 SETBACKS FRONT YARD:20 FT PER UDO (SHELBURNE ROAD & BACON STREET) SIDE YARD:10 FT REAR YARD:30 FT LOT COVERAGE:70% MAX. BLDG COVERAGE:40% MAX. LOT SIZE:40,000 SF MIN. HEIGHT REQ'S:2 STORIES MIN. PLAN INFORMATION: EXISTING LOT SIZE:29,700 SF / 0.68 AC (BOTH LOTS COMBINED) BLDG COVERAGE:1,981 SF / 0.05 AC OR ±6.67% OVERALL LOT COVERAGE:±26,576 SF / 0.61 AC OR ±89.5% FRONT YARD: SHELBURNE ROAD:±2,995 SF / 0.07 AC OR 98.6% BACON STREET:±2,644 SF / 0.06 AC OR 69.7% PROPOSED LOT SIZE:29,700 SF / 0.68 AC (BOTH LOTS COMBINED) BLDG COVERAGE:4,930 SF / 0.11 AC OR ±16.6% OVERALL LOT COVERAGE:±23,610 SF / 0.54 AC OR ±79.5% FRONT YARD: SHELBURNE ROAD:±1,328 SF / 0.03 AC OR 44.3% BACON STREET:±3,000 SF / 0.07 AC OR 79.1% HEIGHT:3 STORIES PARKING:36 SPACES (ON-SITE) 3 SPACES (OFF-SITE BACON ST.) LOT INFORMATION: TAX MAP NO. 1540-00510 CHAMPLAIN OIL COMPANY, INC. V. 126 P 130 20,943 SF / 0.48 AC TAX MAP NO. 0090-00017 BACON STREET PROPERTIES, LLC V. 609 P 786 8,757 SF / 0.20 AC OHOHOHOHOHOHOHOHOHOHOHOHOHOH OH OH OH OH OH OH OH OH OH OH OH OH OH OHUGUG GGGGGWG G G W W W W W W W W W W W W W W SSSSSSSSStax map no. 1540-00520 Germania Property Group, LLC v. 975 p. 135 map slide 548, 555, 589 tax map no. 0090-00025 John Larkin, INC v. 1375 p. 324 map slides 548, 555, 589, 600 tax map no. 0090-00014 Deimer Properties, INC. v. 479 p. 704 map slide 67 S S S S S S "BACON STREET" SIGN "STOP" SIGNS15" CLAY10" CLAY D WSMH R=207.75 iOUT=201.7 (15")N iIN=201.8 (10")E DMH R=210.29 iOUT=205.4± (10" PVC)N iIN=205.4± (18" HDPE)E SUMP @ 204.45 D D DCB R=209.74 iIN=205.74 (15" HDPE)E iIN=205.72 (18" HDPE)S iOUT=205.59 (18" HDPE)W SUMP @ 204.2 CB R=210.55 iOUT=206.25 (20" HDPE) SUMP @ 205.45 D D 10" PVC6" HDPE 6" HDPE SMH R=210.39 iIN=203.47 (4" PVC)N iIN=203.4E iIN=203.4±S iOUT=203.37 (10" PVC)W 4" PVCSS10" PVCDD CB R=208.93 iIN=206.53 (8" PVC)S iOUT=206.53 (8" PVC)W SUMP @ 205.38 8" PVC8" PVC CB R=208.78 i=206.93 (8" PVC) SUMP @ 205.9 SMH R=209.48 iIN=202.11 (10" PVC)E iIN=202.13 (8" PVC)N iOUT=202.08 (10" PVC)WSSS8" PVCDMH R=211.87 SMH R=211.60 CB R=207.01 i=204.51 (6") SUMP @ 204.0 CB R=209.75 i=206.75 (6" HDPE) SUMP @ 206.6 10" PVC 15 " H D P E 18" HDPE 50' WIDE ACCESS EASEMENT TO FARRELL STREET209208208 209 211 211 211 212210210 210 210 210 210210PROJECT TBM TOP NORTH B.BOLT "X" ELEV.=212.11 POLE 16-30 34308 THREE PHASE POLE 15 34306 SINGLE PHASE POLE 1 34309 THREE PHASE WWD D D D D D D D DDDDDDDDDDDDDDDAPPROXIMATE LOCATION OF UNDERGROUND STORM SEWER BASED ON CITY OF BURLINGTON MAPPING - NOT FIELD VERIFIED 6" WATER MAIN 21 0 209209 TELEPHONE MANHOLE SUMP @ 199.16 211.65 DCONCRETE CURB TC 211.30 BC 210.80 TC 211.45 BC 210.95 TC 211.73 BC 211.23 FLUSH CURB TC 211.73 BC 211.23WWWWUG UG UG FLUSH CURB FLUSH CURB CONCRETE CURB BACON STREET U.S. ROUTE 7 / SHELBURNE ROAD211.40 3.75% 2% 210.35 211.50 211.85 2% 2% 1% 1.5% 211.85 1.5%4" C900 WATER LINENEW 3 PHASE TRANSFORMER 211.60 211.1 211.90 FILTERRA FTPD-G 6'X10' VAULT GRATE = 210.3 12" iOUT = 206.2 DD D D DD D DDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDD DDDD D D D DDDDDDDDDD D DDDDDDDDDDPROPOSED BUILDING 4,930 SF FINISHED FLOOR ELEVATION = 211.90DDDDDD D D RAIN GUARDIAN TURRET GRATE = 210.5 OUTLET = 209.63 RDRDRD6" HDPE S=0.006FT/FT STMH 12" iIN = 206.1 12" iOUT = 206.1 D 18" iIN = 205.4 STMH 18" iOUT = 205.55 15"iIN (E) = 205.6 12" iIN (S) = 205.9 12" iIN (N) = 205.8 OUTLET CONTROL STRUCTURE 36" DIAMETER 12" GRATE = 209.5 6" iIN = 206.25 12"iOUT = 206.1518" HDPE S=0.004FT/FT D D D D D D D D D D D D D D D 15" HDPE S=0.0031FT/F T STMH 15" iOUT (W)= 205.85 15"iIN (E) = 205.90 12" iIN (S) = 205.90 15" H D P E S = 0.0 0 3FT/FTDDDDDSTMH 12" iIN (2) = 206.05 15" iOUT = 206.05 6" HDPE ROOF DRAIN 6" iOUT = 210.0 OUTLET CONTROL STRUCTURE 36" DIAMETER 12" GRATE = 210.5 6" iIN = 206.4 12"iOUT = 206.3 BIORETENTION AREA #1 TOP OF MULCH AT 209.25 BIORETENTION AREA #2 TOP OF MULCH AT 209.0 ±3% ±1.6% 211.85 211.85 1.5% ±1.6% TC 211.73 BC 211.23 211.85 211.90211.90 211.85 211.65 211.85 2% 211.50 209.50 210.40 1% 210.40 210.40209210211 211 211 21121 1211210210 210 210 210209 2 1 1 211 S SSSSSSSSSSSSFILTERRA FTPD-G 6'X12' VAULT GRATE = 210.3 12" iOUT = 206.2 S S S S D RDRDRDRDRDRDRDRDRD211DDDDPEASTONE DIAPHRAM FLUSH CURB 20" HIGH SEAT WALL WITH CAP 3 BIKE RACKS 210.30 210.30 PROPOSED LIGHTED BOLLARD (TYPICAL) HELIO M30/K4 SECURITY BOLLARD, SERIES 900, NON-ILLUMINATED (TYPICAL) YARD DRAIN 12" RIM = 211.5 6" iOUT = 210.0 YARD DRAIN 12" RIM = 211.0 6"iIN = 209.6 6" iOUT = 209.5 6" iOUT = 209.3 6" iOUT = 209.75 ROOF DRAINS FROM 3RD STORY ROOF TO BE ROUTED TO BIRETENTION AREA #1 ROOF DRAINS FROM TERRACE ROOF TO BE ROUTED TO BIRETENTION AREA #2 UD UD UD 6" UNDERDRAIN (SEE DETAIL) CLEANOUT (TYPICAL)UDUD2100 Feet Graphic Scale 10 10 20 15°±VT GridMagneticSheet Title Project Title Use of These Drawings Scale: Project Number: Date: Drawn By: Project Engineer: Approved By: No. Description Date By Revisions 478 BLAIR PARK ROAD | WILLISTON, VERMONT 05495 802 879 6331 | WWW.TCEVT.COM ENGINEERING SURVEY No. 8917 CIVIL PROF ESSIONAL E N G INEERLICE N S E DJENNIFER ANN DESA U T ELSSTA TE O F VER M ONT Field Book: 1. Unless otherwise noted, these Drawings are intended for preliminary planning, coordination with other disciplines or utilities, and/or approval from the regulatory authorities.  They are not intended as construction drawings unless noted as such or marked approved by a regulatory authority. 2. By use of these drawings for construction of the Project, the Owner represents that they have reviewed, approved, and accepted the drawings, obtained all necessary permits, and have met with all applicable parties/disciplines, including but not limited to, the Engineer and the Architect, to insure these plans are properly coordinated including, but not limited to, contract documents, specifications, owner/contractor agreements, building and mechanical plans, private and public utilities, and other pertinent permits for construction. 3. Owner and Architect, are responsible for final design and location of buildings shown, including an area measured a minimum five (5) feet around any building and coordinating final utility connections shown on these plans. 4. Prior to using these plans for construction layout, the user shall contact TCE to ensure the plan contains the most current revisions. 5. These Drawings are specific to the Project and are not transferable. As instruments of service, these drawings, and copies thereof, furnished by TCE are its exclusive property.  Changes to the drawings may only be made by TCE. If errors or omissions are discovered, they shall be brought to the attention of TCE immediately. 6. It is the User's responsibility to ensure this copy contains the most current revisions. PLANNING ENVIRONMENTAL TAX ID: 1540-00510 Stormwater Plan C4-01 06/04/2020 1" = 10' 19-202 RMP/CMJ JAD    348 Bacon St. Properties, LLC 510 Shelburne Road South Burlington, Vermont PROPOSED CONNECTION TO MUNICIPAL STORM SEWER DRAINAGE AREA #4 DRAINAGE AREA #3 DRAINAGE AREA #2 DRAINAGE AREA #1 Sheet Title Project Title Use of These Drawings Scale: Project Number: Date: Drawn By: Project Engineer: Approved By: No. Description Date By Revisions 478 BLAIR PARK ROAD | WILLISTON, VERMONT 05495 802 879 6331 | WWW.TCEVT.COM ENGINEERING SURVEY No. 8917 CIVIL PROF ESSIONAL E N G INEERLICE N S E DJENNIFER ANN DESA U T ELSSTA TE O F VER M ONT Field Book: 1. Unless otherwise noted, these Drawings are intended for preliminary planning, coordination with other disciplines or utilities, and/or approval from the regulatory authorities.  They are not intended as construction drawings unless noted as such or marked approved by a regulatory authority. 2. By use of these drawings for construction of the Project, the Owner represents that they have reviewed, approved, and accepted the drawings, obtained all necessary permits, and have met with all applicable parties/disciplines, including but not limited to, the Engineer and the Architect, to insure these plans are properly coordinated including, but not limited to, contract documents, specifications, owner/contractor agreements, building and mechanical plans, private and public utilities, and other pertinent permits for construction. 3. Owner and Architect, are responsible for final design and location of buildings shown, including an area measured a minimum five (5) feet around any building and coordinating final utility connections shown on these plans. 4. Prior to using these plans for construction layout, the user shall contact TCE to ensure the plan contains the most current revisions. 5. These Drawings are specific to the Project and are not transferable. As instruments of service, these drawings, and copies thereof, furnished by TCE are its exclusive property.  Changes to the drawings may only be made by TCE. If errors or omissions are discovered, they shall be brought to the attention of TCE immediately. 6. It is the User's responsibility to ensure this copy contains the most current revisions. PLANNING ENVIRONMENTAL SD-001 1" = 1' LAST REVISED 11/21/2019TRUDELL CONSULTING ENGINEERS TYPICAL BITUMINOUS PAVEMENT A C B D RESIDENTIAL 6 12 2-1/2 1-1/2 6 12 2 1 PARKING LOTS THICKNESS (INCHES) ROADS PRIVATE 2 COMMERCIAL 6 18 3 2 N/A 12 4 2 1/2 18 6 1 1/2 COMMERCIALRESIDENTIAL 6 6666E NOTES: 1.SUBBASE, SAND CUSHION AND SUBGRADE SHOULD BE CONSTRUCTED AND COMPACTED TO THE DIMENSIONS SHOWN IN ACCORDANCE WITH VERMONT AGENCY OF TRANSPORTATION SPECIFICATIONS, STANDARD A-76. WHERE MORE STRINGENT LOCAL ORDINANCES HAVE BEEN ADOPTED RELATIVE TO ROAD DIMENSIONS AND CONSTRUCTION, THEY SHOULD GOVERN. 2.COMPACT ALL SUBBASE MATERIALS TO 95% MAXIMUM DENSITY (STANDARD PROCTOR). 3.IF GROUNDWATER OR SOFT SPOTS ARE ENCOUNTERED CONTACT THE ENGINEER TO DISCUSS ADDED MEASURES SUCH AS UNDERDRAIN. SLOPE SUBBASE TO UNDERDRAIN LOW POINTS. DRIVEWAYS SECTION WEARING COURSE (TYPE III) (VAOT 406) BASE COURSE (TYPE II) (VAOT 406) CRUSHED GRAVEL (VAOT 704.05A FINE) GRAVEL BASE (VAOT 704.04) OR CRUSHED GRAVEL (VAOT 704.05A COARSE) MIRAFI 500X STABILIZATION FABRIC INSTALLATION IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS 6" SAND BORROW AND CUSHION TO BE USED IN POORLY DRAINED SOILS OR OVER BEDROCK FOR ROADS AND SIDEWALKS (VAOT 703.03) UNDISTURBED SUBGRADE OR COMPACTED FILL A B C D E SD-013 1"=1-0' LAST REVISED 07/18/20132013 TRUDELL CONSULTING ENGINEERS REINFORCED CONCRETE PAD 6" CLASS A CONCRETE SLAB, BROOM FINISH #5 REINFORCING BARS 12" O.C. BOTH WAYS, 3" CLEAR 12" BANK RUN GRAVEL COMPACTED SUBBASE SD-016LAST REVISED 03/21/20132013 TRUDELL CONSULTING ENGINEERS TRASH DUMPSTER ENCLOSURE 10'0" 8'0" OPENING 1"=4'0" 1"=4'0" FRONT ELEVATION SILL5.5"1"=1'0" SIDING DETAIL 1"=4'0" TYPICAL ELEVATION LATCH PLAN 3.5" 1"=4'0" SECTION 2"X4" FRAME 1"X8" PINE CAP GATES 1/2" MDO BOARD 1'X4" TRIMSTRAP HINGE BOLT THROUGH FRAME 5" CONCRETE SLAB REINFORCED WELDED WIRE FABRIC WWF W2.1 X W2.1 CLASS B CONCRETE 12" BASE OF CRUSHER RUN COMPACTED TO .9 PROCTOR 1"X6" #2 PINE SIDING STAIN TO MATCH BUILDING SD-048LAST REVISED 06/18/20142014 TRUDELL CONSULTING ENGINEERS TYPICAL SIDEWALK LAYOUT 1/4"/FT. 4' 30"4'30"1/2" RADIUS TOOLED JOINT NOTES: 1.REFER TO BASIC GRID PATTERN ON SITE PLAN 2.JOINT SPACING IS 5 FT. NORMAL SPACING WITH A MAXIMUM OF 8 FT. AND MINIMUM OF 2 FT. LINEAR DIMENSIONS AND NOT INSIDE CORNERS 3.#4 REINFORCING ON 30 INCH CENTERS BOTH DIRECTIONS IN CENTER OF SIDEWALK 4.LAP BARS 30 BAR DIAMETERS. 5.EXPANSION JOINTS AT 20 FT. O.C. 5" LAP BARS 30 BAR DIAMETERS REINFORCING BARS (TYPICAL) TOOLED JOINT (TYPICAL) EXPANSION JOINT MATERIAL 20' O.C.REINFORCING BARS SD-036LAST REVISED 02/07/20142013 TRUDELL CONSULTING ENGINEERS BIKE RACK 36"47"2X 0.25" X 12.75" ANCHOR RODS 2 3/8" O.D. GALVANIZED STEEL SCHEDULE 40 PIPE WITH POWDERCOAT FINISH BLACK 35"6" PORTLAND CEMENT PAD CLASS "B" CONCRETE PAVEMENT MARKINGS 1.1 QUALITY ASSURANCE Regulatory Requirements: Comply with materials, workmanship, and other applicable requirements of state DOT or local municipality for pavement-marking work. 1.2 FIELD CONDITIONS Environmental Limitations: Proceed with pavement marking only on clean, dry surfaces and at a minimum ambient or surface temperature of 40 deg F for alkyd materials, 55 deg F for water-based materials, and not exceeding 95 deg F. 1.3 PAVEMENT-MARKING PAINT A.Pavement-Marking Paint: Alkyd-resin type, lead and chromate free, ready mixed, complying with AASHTO M 248; colors complying with FS TT-P-1952. Color: As indicated. B.All pavement marking within VTrans and Town right-of-way shall be in accordance with VTrans specifications. 1.4 PAVEMENT MARKING Apply temporary pavement marking before traffic is allowed on any newly paved area or as site conditions dictate. Allow final wearing surface to age for a minimum of 30 days before applying final permanent pavement marking. 1.5 PROTECTING AND CLEANING A.Protect pavement markings from damage and wear during remainder of construction period. B.Clean spillage and soiling from adjacent construction using cleaning agents and procedures recommended by manufacturer of affected construction. NON STDLAST REVISED 03/14/20182018 TRUDELL CONSULTING ENGINEERS PAVEMENT MARKINGS Site Details C8-01 06/04/2020 Shown 19-202 RMP JAD    348 Bacon St. Properties, LLC 510 Shelburne Road South Burlington, Vermont SD-056 1/2" = 1' LAST REVISED 05/04/2016TRUDELL CONSULTING ENGINEERS CONCRETE CURB, & SIDEWALK FOR SIDEWALKS DIRECTLY ADJACENT TO BUILDINGS5'7" REVEAL 6"1" R BITUMINOUS PAVEMENT FOOTING DRAIN FOUNDATION BY OTHERS NOTE: SEE SITE PLAN FOR SIDEWALK LOCATION 8"x16" FOOTING GRAVEL (3" MAX. STONE SIZE) CONCRETE CURB PIN CURB TO CONCRETE FOUNDATION CONCRETE FOUNDATION 5"BUILDING FACE EXPANSION JOINT MATERIAL CONCRETE WALK (SEE SITE PLAN FOR WIDTH) 30" REBAR (TYPICAL) SD-053 1/2 " = 1' LAST REVISED 10/18/2017TRUDELL CONSULTING ENGINEERS TYPICAL CONCRETE SIDEWALK SPECIFICATIONS: 1)1/2" EXPANSION/CONTRACTION JOINT WITH ASPHALT IMPREGNATED FIBER BOARD FILLER EVERY 50 FEET. 2)SCORED OR TOOLED JOINT (1" DEPTH OR 1/3 THE TOTAL DEPTH OF WALK) WITH A SEPARATION DISTANCE EQUAL TO THE WIDTH OF THE SIDEWALK. 3)FULL-BREAK OR COMPLETE JOINT EVERY 20 FEET. 4)WHERE "HEAVY DUTY CONCRETE SECTION" IS CALLED OUT ON THE SITE PLAN, THE SIDEWALK IS TO BE 8" THICK 5"6"6"VARIES NOTE: DISTANCES ARE TYPICAL AND MAY BE ALTERED FOR SPECIFIC SITE CONDITIONS. CONCRETE WEAR COURSE (4000 PSI) MINIMUM 18" GRAVEL BASE OWNER TO COORDINATE WITH OTHER DISCIPLINES (ARCHITECT/STRUCTURAL ENGINEER) ON SIDEWALK WITHIN 5' OF BUILDING. IN SOME CASES SIDEWALK WILL HAVE FROST WALL OR BE PINNED TO FOUNDATION TO PREVENT FROST ACTION IN FRONT OF DOOR.18"SD-010 3/4" = 1'-0" LAST REVISED 03/27/2013TRUDELL CONSULTING ENGINEERS PAVEMENT CUT TRENCH6' MIN. COVER6"D+2' CL SAW CUT EXISTING PAVEMENT BITUMINOUS PAVEMENT CRUSHED GRAVEL GRAVEL BASE SAND CUSHION COMPACT BACKFILL SAME MATERIAL AS REMOVED IN 6" LIFTS SEE SITE PLAN FOR PIPE SIZE AND MATERIALD MATCH EXISTING ROAD SECTION UNLESS INDICATED OTHERWISE SD-004 1" = 1' LAST REVISED 5/24/2018TRUDELL CONSULTING ENGINEERS TYPICAL CURB DETAIL SLOPE BITUMINOUS PAVEMENT SEE SECTION DETAIL CONCRETE CURB CLASS B CONCRETE GRAVEL BASE CRUSHED GRAVEL MIRAFI 500X FILTER FABRIC 6" R1" 18" 6" TOPSOIL 12" CRUSHED GRAVEL 7" REVEAL SAND BORROW SD-011LAST REVISED 03/20/2013TRUDELL CONSULTING ENGINEERS PAVEMENT JOINT DETAIL 30" 1-1/2" TYPE III OVERLAY 1-1/2" TYPE III 3" TYPE II 6" 18" EXISTING SURFACE EXISTING PAVEMENT MATCH EXISTING HIGHWAY BASE DEPTH EXISTING BASE (ASSUME 24" DEPTH) (ASSUME 5" DEPTH) COLD PLANESAW CUTFINE-GRADED CRUSHED GRAVEL DENSE-GRADED CRUSHED STONE SD-027 1"=1'-0" LAST REVISED 03/22/2017TRUDELL CONSULTING ENGINEERS CONCRETE CURB AND SIDEWALK 1/4"/FT. NOTE: ADDITIONAL MEASURES AT BUILDING ENTRANCE POINTS MAY BE REQUIRED PER THE ARCHITECT, OWNER, OR STRUCTURAL ENGINEER. THIS MAY INCLUDE FOOTING FOR THE SIDEWALK, ADDITIONAL GRAVEL, UNDERDRAIN, OR ADDITIONALLY REBAR. FROST ACTION IS NOT ALWAYS EASILY PREDICTED BUT THE INTENT IS TO MINIMIZE FROST ACTION IN SENSITIVE AREAS SUCH AS HANDICAP RAMPS AND DOOR ENTRANCE POINTS. 6" SAND BORROW AND CUSHION TO BE USED IN POORLY DRAINED SOILS OR OVER BEDROCK (VAOT 703.03) FOR BOTH ROADWAY AND SIDEWALK COMPACT ALL SUBBASE MATERIALS TO 95% MAXIMUM DENSITY (STANDARD PROCTOR) MIRAFI 500X ROAD STABILIZATION FABRIC GRAVEL FOR SUB-BASE CRUSHER RUN GRAVEL OR PLANT MIX SLOPE SUBBASE TO DRAIN BITUMINOUS PAVEMENT CONCRETE CURB CONCRETE SIDEWALK (SEE SITE PLAN FOR WIDTH) EXPANSION JOINT MATERIAL (TO BE PLACED WHERE SIDEWALK ABUTS A STRUCTURE) 6" 7" REVEAL 1" R 18" MIN.5"18"30" REBAR (TYPICAL)8" MIN9" Sheet Title Project Title Use of These Drawings Scale: Project Number: Date: Drawn By: Project Engineer: Approved By: No. Description Date By Revisions 478 BLAIR PARK ROAD | WILLISTON, VERMONT 05495 802 879 6331 | WWW.TCEVT.COM ENGINEERING SURVEY No. 8917 CIVIL PROF ESSIONAL E N G INEERLICE N S E DJENNIFER ANN DESA U T ELSSTA TE O F VER M ONT Field Book: 1. Unless otherwise noted, these Drawings are intended for preliminary planning, coordination with other disciplines or utilities, and/or approval from the regulatory authorities.  They are not intended as construction drawings unless noted as such or marked approved by a regulatory authority. 2. By use of these drawings for construction of the Project, the Owner represents that they have reviewed, approved, and accepted the drawings, obtained all necessary permits, and have met with all applicable parties/disciplines, including but not limited to, the Engineer and the Architect, to insure these plans are properly coordinated including, but not limited to, contract documents, specifications, owner/contractor agreements, building and mechanical plans, private and public utilities, and other pertinent permits for construction. 3. Owner and Architect, are responsible for final design and location of buildings shown, including an area measured a minimum five (5) feet around any building and coordinating final utility connections shown on these plans. 4. Prior to using these plans for construction layout, the user shall contact TCE to ensure the plan contains the most current revisions. 5. These Drawings are specific to the Project and are not transferable. As instruments of service, these drawings, and copies thereof, furnished by TCE are its exclusive property.  Changes to the drawings may only be made by TCE. If errors or omissions are discovered, they shall be brought to the attention of TCE immediately. 6. It is the User's responsibility to ensure this copy contains the most current revisions. PLANNING ENVIRONMENTAL S-001 3/4" = 1'-0" LAST REVISED 03/22/2017TRUDELL CONSULTING ENGINEERS TYPICAL SEWER TRENCH D + 24" FOR GRASSED AREAS FOR GRAVEL or PAVED SURFACES SEED AND MULCH, OVERFILL FOR SETTLEMENT INSTALL TRENCH DAM IN TRENCH TO PREVENT GROUNDWATER MOVEMENT IN THE PIPE BEDDING. 100' SPACING MAXIMUM. GRADE AT 2:1 SLOPE WHEN DEPTH EXCEEDS 5' BACKFILL FREE OF ORGANIC OR FROZEN MATERIAL. COMPACTED TO 90% DENSITY STANDARD PROCTOR IN GRASSED AREAS INITIAL 12" OF SELECT BACKFILL FREE OF ORGANIC OR FROZEN MATERIAL COMPACTED TO 95% DENSITY STANDARD PROCTOR IN GRASSED AREAS WHERE MIN. COVER OF 5' CAN NOT BE MAINTAINED COVER SEWER MAIN WITH 2" RIGID INSULATION. PLACE INSULATION AT ALL ROAD, DRIVE AND SIDEWALK CROSSINGS. EXTEND RIGID INSULATION 10' BEYOND CROSSINGS IN BOTH DIRECTIONS SEWER MAIN (SEE SITE PLAN FOR SIZE & PIPE MATERIALS) INSTALL TO MANUFACTURER'S REQUIREMENTS. CLASS I BEDDING 3/4" CRUSHED STONE NOTES: 1.LENGTH OF OPEN TRENCH SHALL BE KEPT TO A MINIMUM. 2.IF UNSUITABLE MATERIAL IS REMOVED BELOW BEDDING, REPLACE WITH MATERIAL APPROVED BY ENGINEER AND COMPACT TO 95% MAXIMUM DENSITY. 3.NO MECHANICAL TAMPERS SHALL BE USED DIRECTLY OVER PIPE TO INSURE PIPE IS NOT DAMAGED. 4.BEDDING TO PROVIDE FIRM, STABLE, CONTINUOUS AND UNIFORM SUPPORT FOR THE FULL LENGTH OF PIPE. 5.INSTALL TO STRICTEST INTERPRETATION OF REQUIREMENTS (PLANS, SPECS & MANUFACTURER) BACKFILL MATERIAL TO MATCH STRUCTURAL ROADWAY GRAVEL, SEE ROADWAY SECTION. COMPACTED TO 95% DENSITY STANDARD PROCTOR ALL BACKFILL TO BE COMPACTED IN 6" to 12" LIFTS HAUNCHING BEDDING BACKFILL BACKFILL ℄6"D6"12"SEE ROADWAY SECTIONSDEPTH VARIES - 4' MINIMUM COVER IN GRASSED AREAS5' MINIMUM COVER IN PAVED AREASDETECTABLE METALLIC WARNING TAPE LABELED "SEWER" INSULATION SHALL BE FULL WIDTH OF TRENCH SN-002LAST REVISED 04/28/162016 TRUDELL CONSULTING ENGINEERS CONTRACTOR CERTIFICATION FOR WASTEWATER SYSTEM PRIOR TO THE DESIGN ENGINEER CERTIFYING THAT THE INSTALLATION HAS BEEN INSTALLED IN ACCORDANCE WITH THE PERMITTED DESIGN, THE CONTRACTOR SHALL PROVIDE A CERTIFICATION THAT THE WASTEWATER SYSTEM WAS INSTALLED AND TESTED IN ACCORDANCE WITH THE APPROVED DESIGN PLANS. STATE PERMITS REQUIRE THERE SHALL BE NO DEVIATIONS FROM THE APPROVED PLANS WITHOUT PRIOR APPROVALS. THE DESIGN ENGINEER SHALL BE NOTIFIED AND ALLOWED TO OBSERVE THE CRITICAL PHASES OF CONSTRUCTION INCLUDING ANY REQUIRED TESTS. LIKEWISE, THE DESIGN ENGINEER SHALL BE NOTIFIED OF ANY DEVIATIONS FROM THE APPROVED PLANS. SINCE THE DESIGN ENGINEER DOES NOT CUSTOMARILY OBSERVE ALL PHASES OF THE WORK, OR ALL TESTING, HE MAY RELY ON THE CONTRACTOR'S CERTIFICATION AS THE BASIS FOR FINAL CERTIFICATION. THE CONTRACTOR SHALL THEREFORE SIGN AND RETURN A COPY OF THE FOLLOWING CERTIFICATION UPON COMPLETION OF THE WORK: "I HEREBY CERTIFY THAT I HAVE INSTALLED, PROPERLY TESTED, AND SUCCESSFULLY PASSED THOSE TESTS, AND THE WASTEWATER DISPOSAL AND COLLECTION SYSTEM(S) ARE BUILT IN ACCORDANCE WITH THE APPROVED DESIGN PLANS AND APPLICABLE PERMIT CONDITIONS." CONTRACTOR NAME AUTHORIZED AGENTS NAME SIGNATURE DATE NOTE ANY DEVIATIONS FROM APPROVED PLANS HERE: CONTRACTOR'S CERTIFICATION REQUIRED NOTE: THE CERTIFICATION AND THE PROJECT ENGINEER'S SUBSEQUENT CERTIFICATION DOES NOT VOID THE CONTRACTOR FROM REPAIR OR REPLACEMENT OF DISCREPANCIES DISCOVERED AT A LATER DATE. THE CONTRACTOR REMAINS RESPONSIBLE, INCLUDING CUSTOMARY GUARANTEE AND WARRANTY PERIODS. Sanitary Details C8-02 06/04/2020 Shown 19-202 RMP JAD    348 Bacon St. Properties, LLC 510 Shelburne Road South Burlington, Vermont SN-008LAST REVISED 08/02/20172017 TRUDELL CONSULTING ENGINEERS TESTING GRAVITY SEWERS (ENVIRONMENTAL PROTECTION RULES) CH 1 EFFECTIVE 9/29/07 SECTION 1-A-03(K)(2) AIR TESTING SEWERS 3 8 10 4 6 0.2 0.3 0.7 1.2 1.5 A.TEST THE GRAVITY SEWER BY A PRESSURIZED AIR TEST BETWEEN CONSECUTIVE MANHOLES. PLUG ALL OPENINGS OF THE TEST SECTION AND CONNECT THE AIR CONTROL EQUIPMENT TO THE TAPPED END. B.SUPPLY AIR SLOWLY TO THE PIPE UNTIL REACHING A CONSTANT PRESSURE OF 4.0 PSI GREATER THAN THE AVERAGE PRESSURE OF ANY SURROUNDING GROUNDWATER. PRESSURE WILL NORMALLY DROP AS TEMPERATURE STABILIZES. SUPPLY THE AIR SO THAT THE PRESSURE REMAINS ABOVE 3.0 PSI FOR AT LEAST 5 MINUTES DURING TEMPERATURE STABILIZATION. USE A PRESSURE GAUGE HAVING A RANGE FROM 0 TO 5 PSI. THE GAUGE SHOULD HAVE MINIMUM DIVISIONS OF 0.1 PSI AND AN ACCURACY OF +- 0.04 PSI. REGULATE THE AIR PRESSURE TO PREVENT IT FROM EXCEEDING 5.0 PSI. C.AFTER STABILIZATION, ADJUST PRESSURE TO 3.5 PSI OR ABOVE AND SHUT OFF AIR SUPPLY. START THE STOP WATCH. THE TIME REQUIRED FOR THE TEST IS DEPENDENT ON PIPE DIAMETER PER TOTAL LENGTH OF PIPE BEING TESTED AND MUST BE AT LEAST: D.IF THE SECTION OF LINE TO BE TESTED INCLUDES MORE THAN ONE PIPE SIZE, CALCULATE THE TEST TIME FOR EACH SIZE AND ADD THE TEST TIMES TO EQUAL THE TOTAL SECTION TEST TIME. E.IF THERE IS GROUND WATER ABOVE THE SEWER LINE THE AIR TEST PRESSURE WILL BE INCREASED BY 0.5 PSI FOR EACH FOOT OF WATER ABOVE THE INVERT OF THE PIPE. DIFFERENCES DUE TO AIR TEMPERATURE AND BAROMETRIC PRESSURE WILL BE CONSIDERED NEGLIGIBLE. F.IF THE PRESSURE DROPS MORE THAN 1 PSI DURING THE TEST TIME, THE PIPE WILL HAVE FAILED AND ADEQUATE REPAIRS AND RETESTING WILL BE REQUIRED AT NO EXPENSE TO OWNER. G.IT IS NOT NECESSARY TO HOLD THE TEST FOR THE WHOLE PERIOD WHEN IT IS CLEARLY EVIDENT THAT THE RATE OF AIR LOSS IS LESS THAN THE ALLOWABLE. NOMINAL PIPE DIA. IN INCHES T (TIME) MIN/100 FT. 12 15 1.8 2.1 18 2.4 21 30 33 24 27 3.0 3.6 4.2 4.8 5.4 NOMINAL PIPE DIA. IN INCHES T (TIME) MIN/100 FT. 36 39 6.0 6.6 42 7.3 *ALL TESTING SHALL BE PERFORMED IN THE PRESENCE OF THE TOWN ENGINEER OR PUBLIC WORKS DEPARTMENT AND TRUDELL CONSULTING ENGINEERS (TCE). CONTRACTOR SHALL PRE-TEST SUCCESSFULLY PRIOR TO CONTACTING ENGINEER. THE PRE-TEST IS TO ENSURE PASSING RESULTS PRIOR TO OFFICIAL TESTING OBSERVATION. DEFLECTION TESTING SEWERS A.AFTER A FLEXIBLE PIPE SEWER, SUCH AS PVC, HAS BEEN BACKFILLED FOR 30 DAYS, A PIPE DEFLECTION TEST SHALL BE PERFORMED. B.THE TEST SHALL BE CONDUCTED USING A RIGID BALL OR MANDREL HAVING A DIAMETER EQUAL TO 92.5% OF THE PIPE DIAMETER. THIS DEVICE WILL BE PULLED THROUGH THE SEWER BY A ROPE WITHOUT THE MEANS OF MECHANICAL EQUIPMENT. THE MAXIMUM ALLOWABLE VERTICAL DEFLECTION SHALL BE 7.5%. C. IF THE BALL OR MANDREL CANNOT BE SUCCESSFULLY PULLED THROUGH THE SEWER PIPE, THOSE SECTIONS OF PIPE NOT MEETING THE DEFLECTION REQUIREMENTS SHALL BE EXCAVATED AND THE EMBEDMENT AND BACKFILL REPLACED. IF, IN THE OPINION OF THE ENGINEER, THE PIPE HAS BEEN DAMAGED, IT SHALL BE REMOVED AND REPLACED. S-011 1/2" = 1' LAST REVISED 03/18/2016TRUDELL CONSULTING ENGINEERS SEWER CONNECTION TO EXISTING MANHOLE LC 5" SET CORE AND GASKET SEAL TO PLACE PIPE INVERT AT TABLE LEVEL 48" DIA. NEW SEWER MAIN POSITIVE SEAL GASKET SYSTEM WITH POWER SLEEVE EXPANSION. ENGINEER TO OBSERVE CONNECTION. EXISTING SEWER MAIN GASKETED 22° ELBOW DIRECTION OF FLOWPLAN VIEW NOTE: SEE SITE PLAN FOR CORE LOCATION, PIPE SIZE AND INVERT. REFORM OR RE-BUILD INVERTS AS NEEDED TAKE MEASURES TO ENSURE MANHOLE AND CONNECTIONS ARE WATER TIGHT GRAVEL BACKFILL AROUND STRUCTURE COMPACTED IN 6" LIFTS TO 95% DENSITY STANDARD PROCTOR, UNLESS INDICATED OTHERWISE 5'x10' HEAVY DUTY GREASE TRAP 1000-3500 GALLON (HD5-10) 44"51" 1500 GALLON HD5-10-1000 33" 56"49" 57"64"HD5-10-1500 HD5-10-1250 41" 49"24,930 LB 1250 GALLON 1000 GALLON 72" 78" 84" 23,750 LB 22,570 LB HD5-10-2000 HD5-10-2500 HD5-10-3000 HD5-10-3500 2000 GALLON 2500 GALLON 3000 GALLON 3500 GALLON 79" 95" 111" 127" 72" 88" 104" 120" 102" 120" 148" 64" 80" 96"132" 112" 28,490 LB 32,040 LB 34,410 LB 37,560 LB * * * SPECIFICATIONS: - CONCRETE MINIMUM STRENGTH 5000PSI @ 28 DAYS - STEEL REINFORCEMENT GRADE 60 - JOINTS SEALED WITH BUTYL SEALANT - INLET AND OUTLET BAFFLES BY OTHERS - H20 LOADING AVAILABLE UPON REQUEST - (*) DENOTES TOP SEAM - WEIGHTS SUBJECT TO VARIATION S-040LAST REVISED 05/03/2016TRUDELL CONSULTING ENGINEERS 8"6" 6"8"FINISH GRADE - SLOPE GROUND TO DRAIN AWAY FROM COVERS OUTLET - REFER TO SITE PLAN FOR PIPE SIZE, TYPE & INVERT ELEVATION LOW PRESSURE SEAL LIQUID LEVEL 24" DIA. PVC RISER & 26" FIBERGLASS COVER 24" DIA. PVC RISER & 26" FIBERGLASS COVER (FIELD CUT TO DESIRED HEIGHT) NOTE: IF THE TOP OF THE TANK IS GREATER THAN 36" BELOW GRADE THE CONTRACTOR IS TO VERIFY WITH THE SUPPLIER ADEQUATE STRUCTURAL STRENGTH NOTE: THE TANK DIMENSIONS MAY VARY WITH SUPPLIERS. THE CONTRACTOR SHOULD VERIFY DIMENSIONS WITH SUPPLIER PRIOR TO INSTALLATION WATERTIGHT CONNECTION FOR ALL RISERS BY CASTING PVC RISER ADAPTER INTO CONCRETE (TYPICAL) INLET - REFER TO SITE PLAN FOR INVERT ELEVATION 3/4 CRUSHED STONE OR GRAVEL FOR SUBBASE OR AS REQUIRED BY ENGINEER IF WET AND OR UNSTABLE CONDITIONS EXIST UNDISTURBED SOIL PEA STONE BACKFILL AROUND STRUCTURES 18" PORTHOLE 4" PVC INLET TEE 6" MODEL TANK CAPACITY INLET (A) OUTLET (B) HEIGHT (C) LIQUID (D) WEIGHT BDA36" MAX C1/2" = 1'12"TESTING MANHOLES, TANKS, AND STRUCTURES 1.*ALL TESTING SHALL BE PERFORMED IN THE PRESENCE OF THE TOWN ENGINEER OR PUBLIC WORKS DEPARTMENT AND TRUDELL CONSULTING ENGINEERS (TCE). CONTRACTOR SHALL PRE-TEST SUCCESSFULLY PRIOR TO CONTACTING ENGINEER. THE PRE-TEST IS TO ENSURE PASSING RESULTS PRIOR TO OFFICIAL TESTING OBSERVATION. 2.EACH STRUCTURE SHALL BE TESTED BY MEANS OF A WATER TEST OR VACUUM TEST PRIOR TO THE BACKFILLING OF THE STRUCTURE. IN ANY CASE THERE SHALL BE NO VISIBLE LEAKAGE INTO THE BASE OR WALLS OF A COMPLETED STRUCTURE. 3.AFTER THE STRUCTURE HAS BEEN ASSEMBLED IN PLACE, ALL LIFTING HOLES AND EXTERIOR JOINTS SHALL BE FILLED AND PAINTED WITH AN APPROVED NON-SHRINKING MORTAR IN MANHOLES. THE TEST SHALL BE MADE PRIOR TO PLACING THE SHELF AND INVERT. IF THE GROUNDWATER TABLE HAS BEEN ALLOWED TO RISE ABOVE THE BOTTOM OF THE STRUCTURE, THE ENGINEER MAY DIRECT IT TO BE LOWERED FOR THE DURATION OF THE TEST. ALL PIPES AND OTHER OPENINGS INTO THE STRUCTURE SHALL BE SUITABLY PLUGGED AND THE PLUGS BRACED TO PREVENT DISPLACEMENT. 4.IF THE CONTRACTOR ELECTS TO BACKFILL PRIOR TO WATER TESTING, FOR ANY REASON, IT SHALL BE AT HIS OWN RISK AND IT SHALL BE INCUMBENT UPON THE CONTRACTOR TO DETERMINE THE REASON FOR ANY FAILURE OF THE TEST. NO ADJUSTMENT IN THE LEAKAGE ALLOWANCE WILL BE MADE FOR UNKNOWN CAUSES SUCH AS LEAKAGE OF PLUGS, ABSORPTION, ETC. I.E., IT WILL BE ASSUMED THAT ALL LOSS OF WATER DURING THE TEST IS A RESULT OF LEAKS THROUGH THE JOINTS OR THROUGH THE CONCRETE. FURTHERMORE, THE CONTRACTOR SHALL TAKE ANY STEPS NECESSARY TO ASSURE THE ENGINEER THAT THE WATER TABLE IS BELOW THE BOTTOM OF THE STRUCTURE THROUGHOUT THE TEST. 5.IF THE GROUNDWATER TABLE IS ABOVE THE HIGHEST JOINT IN THE STRUCTURE, AND IF THERE IS NO LEAKAGE INTO THE STRUCTURE AS DETERMINED BY THE ENGINEER, SUCH A TEST CAN BE USED TO EVALUATE THE WATER TIGHTNESS OF THE STRUCTURE. HOWEVER, IF THE ENGINEER IS NOT SATISFIED, THE CONTRACTOR SHALL LOWER THE WATER TABLE AND CARRY OUT THE TEST AS DESCRIBED HEREINBEFORE. 6.MANHOLE WATER TEST: THE STRUCTURE SHALL BE FILLED WITH WATER TO THE TOP OF THE RISERS, PAST ALL SEAMS. THE TANKS SHALL SIT FOR A PERIOD OF ONE HOUR TO ALLOW FOR ABSORPTION. AFTER ONE HOUR, THE STRUCTURE SHALL BE REFILLED TO THE TOP ABOVE ALL SEAMS. THE TANK SHALL BE TESTED FOR A MINIMUM OF 6 HOURS. AT THE END OF THE 6-HOUR TEST PERIOD, THE MANHOLE SHALL BE REFILLED TO THE STARTING POINT, MEASURING THE VOLUME OF WATER ADDED. THE VOLUME OF WATER ADDED SHALL BE CONVERTED TO A 24-HOUR RATE AND THE LEAKAGE DETERMINED ON THE BASIS OF DEPTH. THE LEAKAGE FOR EACH MANHOLE SHALL NOT EXCEED ONE GALLON PER VERTICAL FOOT FOR A 24 HOUR PERIOD AND THERE SHALL BE NO VISIBLE INFILTRATION. REPAIRS BY APPROVED METHODS MAY BE MADE, AS DIRECTED BY THE ENGINEER, TO BRING THE LEAKAGE WITHIN ALLOWABLE RATE OF ONE GALLON PER FOOT PER DAY. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO UNCOVER THE MANHOLE, AS NECESSARY, AND TO DISASSEMBLE, RECONSTRUCT OR REPLACE IT AS DIRECTED BY THE ENGINEER. THE MANHOLE SHALL THEN BE RETESTED. 7.TANK WATER TEST: THE STRUCTURE SHALL BE FILLED WITH WATER TO THE TOP OF THE RISERS, PAST ALL SEAMS. THE TANKS SHALL SIT FOR A PERIOD OF 24-HOURS TO ALLOW FOR ABSORPTION. PLASTIC, STEEL, AND FIBERGLASS TANKS DO NOT NEED A 24-HOUR ABSORPTION PERIOD AND MAY BE TESTED IMMEDIATELY. AFTER 24-HOURS, REFILL THE TANK. IF AFTER ONE HOUR THERE IS NO MEASURABLE DROP IN FLUID LEVEL THE TANK SHALL BE CONSIDERED WATER TIGHT. 8.MANHOLE VACUUM TEST: THE CONTRACTOR SHALL FURNISH THE MANHOLE CONE SEAL, VACUUM PUMP, ALL NECESSARY GAUGES, HOSES, AND EQUIPMENT TO PERFORM THE TEST. 8.1.MANHOLES THAT HAVE BEEN BACKFILLED SHALL BE EXCAVATED TO EXPOSE THE ENTIRE EXTERIOR OR THE WATER TEST SHALL BE USED. 8.2.A PLATE WITH AN INFLATABLE RUBBER RING THE SIZE OF THE TOP OF THE MANHOLE SHALL BE INSTALLED BY INFLATING THE RING WITH AIR TO A PRESSURE ADEQUATE TO PREVENT LEAKAGE OF AIR BETWEEN THE RUBBER RING AND THE MANHOLE WALL. 8.3.PUMP THE AIR OUT OF THE MANHOLE THROUGH AN OPENING IN THE TEST PLATE UNTIL A VACUUM IS CREATED INSIDE THE MANHOLE EQUAL TO 10 INCHES OF MERCURY USING AN APPROVED VACUUM GAUGE. THEN STOP THE REMOVAL OF AIR AND BEGIN THE TEST. 8.4.THE VACUUM DROP SHALL NOT EXCEED 1 INCH OF MERCURY OVER A 2 MINUTE PERIOD FOR MANHOLES 0-10' DEEP, OVER 2.5 MINUTES FOR MANHOLES 10.1-15' DEEP, AND OVER 3 MINUTES FOR MANHOLES DEEPER THAN 15'. IF MORE THAN A 1 INCH DROP OCCURS WITHIN 2 MINUTES, THE MANHOLE HAS FAILED THE TEST, AND IT SHALL BE REPAIRED OR RECONSTRUCTED AND THEN RETESTED UNTIL IT PASSES AT NO EXPENSE TO OWNER. 9.TANK VACUUM TEST: 9.1.USING A VACUUM TEST, SEAL THE EMPTY TANK AND RISERS AND APPLY A VACUUM TO 4 INCHES (100 MM) OF MERCURY. THE TANK IS CONSIDERED WATERTIGHT IF 90% OF THE VACUUM IS HELD FOR 5 MINUTES PER ASTMC1277-13 SEPTIC TANKS. 10.BACKFILL AROUND THE STRUCTURE UPON SATISFACTORY TEST RESULTS. TRUDELL CONSULTING ENGINEERS LAST REVISED 01/14/2020 SN-007 SN-014LAST REVISED 12/27/2017TRUDELL CONSULTING ENGINEERS CONSTRUCTION NOTES FOR CONTRACTOR & CLIENT/OWNER 1.CONTRACT DOCUMENTS:THESE PLANS WERE PREPARED BY TRUDELL CONSULTING ENGINEERS (TCE) AND ARE INTENDED TO BE USED IN CONJUNCTION WITH THE STANDARD GENERAL CONDITIONS OF THE CONSTRUCTION CONTRACT, #C-700 PREPARED BY THE ENGINEERS JOINT CONTRACT DOCUMENTS COMMITTEE (EJCDC), LATEST EDITION. COPIES ARE AVAILABLE AT WWW.NSPE.ORG/EJCDC 2.UNDERGROUND IMPROVEMENTS: THE LOCATION OF EXISTING UNDERGROUND UTILITIES AND IMPROVEMENTS SHOWN ARE ASSUMED BASED ON RESEARCH, UTILITY PLANS PROVIDED BY OTHERS, AND/OR SURFACE EVIDENCE AVAILABLE AND WERE OBTAINED IN A MANNER CONSISTENT WITH THE ORDINARY STANDARD OF PROFESSIONAL CARE AND HAVE NOT BEEN INDEPENDENTLY VERIFIED BY THE OWNER OR THE DESIGN ENGINEER. 3.DIFFERING SUBSURFACE OR PHYSICAL CONDITIONS: IF CONTRACTOR BELIEVES THAT ANY SUBSURFACE OR PHYSICAL CONDITION AT OR CONTIGUOUS TO THE SITE THAT IS UNCOVERED OR REVEALED EITHER: (1) IS OF SUCH A NATURE AS TO ESTABLISH THAT ANY “TECHNICAL DATA” ON WHICH CONTRACTOR RELIED IS MATERIALLY INACCURATE; OR (2) IS OF SUCH A NATURE AS TO REQUIRE A CHANGE IN THE PLANS/ CONTRACT DOCUMENTS; OR (3) DIFFERS MATERIALLY FROM THAT SHOWN OR INDICATED IN THE PLANS/CONTRACT DOCUMENTS; OR (4) IS OF AN UNUSUAL NATURE, AND DIFFERS MATERIALLY FROM CONDITIONS ORDINARILY ENCOUNTERED AND GENERALLY RECOGNIZED AS INHERENT IN WORK OF THE CHARACTER PROVIDED FOR IN THE PLANS/CONTRACT DOCUMENTS; THEN CONTRACTOR SHALL, PROMPTLY AFTER BECOMING AWARE THEREOF AND BEFORE FURTHER DISTURBING THE SUBSURFACE OR PHYSICAL CONDITIONS OR PERFORMING ANY WORK IN CONNECTION THEREWITH (EXCEPT IN AN EMERGENCY), NOTIFY OWNER AND ENGINEER ABOUT SUCH CONDITION. CONTRACTOR SHALL NOT FURTHER DISTURB SUCH CONDITION OR PERFORM ANY WORK IN CONNECTION THEREWITH (EXCEPT AS AFORESAID) UNTIL RECEIPT OF WRITTEN ORDER TO DO SO. ALL PARTIES INVOLVED (OWNER, ENGINEER, ARCHITECT, AND MUNICIPALITY IF APPLICABLE) SHALL AGREE UPON HOW TO PROCEED AND ANY RELATED COST IMPLICATIONS. 4.UTILITIES: PRIVATE AND PUBLIC UTILITIES SUCH AS ELECTRIC, TELEPHONE, GAS, CABLE, FIBER OPTIC ETC. ARE THE RESPONSIBILITY OF THE RESPECTIVE UTILITY COMPANY. ANY INFORMATION SHOWN BY TCE SHOULD BE CONSIDERED PRELIMINARY (USUALLY TO ASSIST WITH PERMITTING). FINAL DESIGN, CONSTRUCTION AND MAINTENANCE ARE THE RESPONSIBILITY OF RESPECTIVE UTILITY COMPANIES. COMPLIANCE WITH EASEMENTS AND REGULATIONS (STATE AND LOCAL) ARE THE RESPONSIBILITY OF RESPECTIVE UTILITY COMPANY. 5.DIGSAFE: IN ACCORDANCE WITH VERMONT STATE LAW (VSA TITLE 30 CHAPTER 86 AND PSB RULE 3,800) THE CONTRACTOR SHALL BE RESPONSIBLE TO CONTACT DIGSAFE SYSTEMS, INC. “DIGSAFE”. AT LEAST 48 HOURS , EXCLUDING SATURDAYS, SUNDAYS, AND LEGAL HOLIDAYS, BUT NOT MORE THAN 30 DAYS BEFORE COMMENCING EXCAVATION ACTIVITIES, EXCEPT IN AN EMERGENCY. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PRE-MARKING THE SITE AND MAINTAINING DESIGNATED MARKINGS. FOR MORE INFORMATION ON DIGSAFE REQUIREMENTS SEE WWW.DIGSAFE.COM . 6.JOBSITE SAFETY: NEITHER THE PROFESSIONAL ACTIVITIES OF TRUDELL CONSULTING ENGINEERS (TCE), NOR THE PRESENCE OF TCE OR ITS EMPLOYEES AND SUB CONSULTANTS AT A CONSTRUCTION SITE, SHALL RELIEVE THE GENERAL CONTRACTOR AND ANY OTHER ENTITY OF THEIR OBLIGATIONS, DUTIES AND RESPONSIBILITIES INCLUDING, BUT NOT LIMITED TO, CONSTRUCTION MEANS, METHODS, SEQUENCE, TECHNIQUES OR PROCEDURES NECESSARY FOR PERFORMING, SUPERINTENDING OR COORDINATING ALL PORTIONS OF THE WORK OF CONSTRUCTION IN ACCORDANCE WITH THE CONTRACT DOCUMENTS AND ANY HEALTH OR SAFETY PRECAUTIONS REQUIRED BY ANY REGULATORY AGENCIES. TCE AND ITS PERSONNEL HAVE NO AUTHORITY TO EXERCISE ANY CONTROL OVER ANY CONSTRUCTION CONTRACTOR OR OTHER ENTITY OR THEIR EMPLOYEES IN CONNECTION WITH THEIR WORK OR ANY HEALTH OR SAFETY PRECAUTIONS. THE CLIENT AGREES THAT THE GENERAL CONTRACTOR IS SOLELY RESPONSIBLE FOR JOBSITE SAFETY, AND WARRANTS THAT THIS INTENT SHALL BE MADE EVIDENT IN THE CLIENT'S AGREEMENT WITH THE GENERAL CONTRACTOR. THE CLIENT ALSO AGREES THAT THE CLIENT, TCE AND TCE'S CONSULTANTS SHALL BE INDEMNIFIED AND SHALL BE MADE ADDITIONAL INSURED UNDER THE GENERAL CONTRACTOR'S GENERAL LIABILITY INSURANCE POLICY. 7.CODES AND STANDARDS COMPLIANCE:TCE SHALL EXERCISE USUAL AND CUSTOMARY PROFESSIONAL CARE IN ITS EFFORTS TO COMPLY WITH CODES, STANDARDS, REGULATIONS, AND ORDINANCES IN EFFECT. THE OWNER ACKNOWLEDGES THAT SUCH REQUIREMENTS MAY BE SUBJECT TO VARIOUS AND CONTRADICTORY INTERPRETATIONS. TCE, THEREFORE, WILL USE ITS REASONABLE PROFESSIONAL EFFORTS AND JUDGMENT TO INTERPRET APPLICABLE REQUIREMENTS AS THEY APPLY TO THE PROJECT. TCE, HOWEVER, CANNOT AND DOES NOT WARRANT OR GUARANTEE THAT THE PROJECT WILL COMPLY WITH ALL INTERPRETATIONS OF SUCH REQUIREMENTS. 8.CONSTRUCTION OBSERVATION: TCE MAY VISIT THE PROJECT AT APPROPRIATE INTERVALS DURING CONSTRUCTION TO BECOME GENERALLY FAMILIAR WITH THE PROGRESS AND QUALITY OF THE CONTRACTOR'S WORK AND TO DETERMINE IF THE WORK IS PRECEDING IN GENERAL ACCORDANCE WITH THE CONTRACT DOCUMENTS. THE OWNER HAS NOT RETAINED TCE TO MAKE DETAILED INSPECTIONS OR TO PROVIDE EXHAUSTIVE OR CONTINUOUS PROJECT REVIEW AND OBSERVATION SERVICES. TCE DOES NOT GUARANTEE THE PERFORMANCE OF, AND SHALL NOT HAVE RESPONSIBILITY FOR, THE ACTS OR OMISSIONS OF ANY CONTRACTOR, SUB-CONTRACTOR, SUPPLIER OR ANY OTHER ENTITY FURNISHING MATERIALS OR PERFORMING ANY WORK ON THE PROJECT. TCE SHALL NOT SUPERVISE, DIRECT OR HAVE CONTROL OVER THE CONTRACTOR'S WORK NOR HAVE ANY RESPONSIBILITY FOR THE CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES OF THE CONTRACTOR. IF THE OWNER DESIRES MORE EXTENSIVE PROJECT OBSERVATION OR FULL-TIME PROJECT REPRESENTATION, THE OWNER SHALL REQUEST SUCH SERVICES BE PROVIDED BY TCE AS ADDITIONAL SERVICES. S-004 1/2" = 1'-0" LAST REVISED 03/22/2017TRUDELL CONSULTING ENGINEERS TYPICAL SEWER MANHOLE (PROFILE) WITH 30" DIA. COVER CL FLEXIBLE RUBBER BOOT 32" MIN.56" MAX.VARIES30"GROUT FRAME TO TOP ECCENTRIC CONICAL TOP SECTION PRECAST CONCRETE ADJUSTING RING MINIMUM 4 INCHES, MAXIMUM 12 INCHES HEAVY DUTY FRAME & LID HS20 LOADING REQUIRED MARKED "SEWER" WITH INTEGRAL GASKET BUTYL RUBBER SEAL TO ALL JOINTS COAT ENTIRE OUTSIDE WITH ASPHALT SEALANT UNLESS WAIVED BY PROJECT ENGINEER AND PUBLIC WORKS 3/4" CRUSHED STONE FOR SUBBASE OR AS REQUIRED BY ENGINEER IF WET AND OR UNSTABLE CONDITIONS EXIST UNDISTURBED SOIL PREFORMED BASE CHANNEL, SLOPE TOP 2" TO SIDE OR CAST IN PLACE INVERT USE MANHOLE STUBS FOR ALL PIPES COPOLYMER POLYPROPYLENE PLASTIC RUNGS WITH 1/2" GRADE STEEL REINFORCEMENT OR EQUAL, 12" O.C. 48" DIA. MANHOLE NOTES: 1.PROVIDE SMOOTH SWEEPING TRANSITIONS BETWEEN INVERTS OF INTERSECTING PIPES. NO SHARP BENDS. 2.IF DEPTH OF MANHOLE IS LESS THAN 7 FEET FROM RIM TO INVERT, THEN A FLAT TOP WILL BE INSTALLED. IF DEPTH IS 7 FEET OR MORE, THEN A CONICAL TOP WILL BE INSTALLED. 3.FORM INVERT TO SAME RADIUS AS LARGEST PIPE LEAVING MANHOLE. 4.IF MUNICIPAL STANDARDS ARE DIFFERENT CONTACT ENGINEER TO MAKE ADJUSTMENTS TO MATCH LOCAL REGULATIONS. 5.PRIOR TO BACKFILL TEST MANHOLE FOR WATER TIGHTNESS IN ACCORDANCE WITH TESTING REQUIREMENTS. SEE DETAIL. SLOPE FRAME AND LID TO MATCH ROAD GRADES REFER TO ROAD SECTIONS FOR DEPTH OF SUBGRADE AND ROADWAY MATERIALS PAVED AREAS UNPAVED AREAS 30" DIA. 8" GROUT AROUND INVERT AT TROUGH INTERFACE TO PROVIDE SMOOTH FLOW PATH 5"12"STAINLESS STEEL CLAMP MANHOLE BOTTOM GRAVEL BACKFILL AROUND STRUCTURE COMPACTED IN 6" LIFTS TO 95% DENSITY STANDARD PROCTOR, UNLESS INDICATED OTHERWISE 6 1 Sheet Title Project Title Use of These Drawings Scale: Project Number: Date: Drawn By: Project Engineer: Approved By: No. Description Date By Revisions 478 BLAIR PARK ROAD | WILLISTON, VERMONT 05495 802 879 6331 | WWW.TCEVT.COM ENGINEERING SURVEY No. 8917 CIVIL PROF ESSIONAL E N G INEERLICE N S E DJENNIFER ANN DESA U T ELSSTA TE O F VER M ONT Field Book: 1. Unless otherwise noted, these Drawings are intended for preliminary planning, coordination with other disciplines or utilities, and/or approval from the regulatory authorities.  They are not intended as construction drawings unless noted as such or marked approved by a regulatory authority. 2. By use of these drawings for construction of the Project, the Owner represents that they have reviewed, approved, and accepted the drawings, obtained all necessary permits, and have met with all applicable parties/disciplines, including but not limited to, the Engineer and the Architect, to insure these plans are properly coordinated including, but not limited to, contract documents, specifications, owner/contractor agreements, building and mechanical plans, private and public utilities, and other pertinent permits for construction. 3. Owner and Architect, are responsible for final design and location of buildings shown, including an area measured a minimum five (5) feet around any building and coordinating final utility connections shown on these plans. 4. Prior to using these plans for construction layout, the user shall contact TCE to ensure the plan contains the most current revisions. 5. These Drawings are specific to the Project and are not transferable. As instruments of service, these drawings, and copies thereof, furnished by TCE are its exclusive property.  Changes to the drawings may only be made by TCE. If errors or omissions are discovered, they shall be brought to the attention of TCE immediately. 6. It is the User's responsibility to ensure this copy contains the most current revisions. PLANNING ENVIRONMENTAL 2017 TRUDELL CONSULTING ENGINEERS TYPICAL WATER MAIN TRENCH INSTALL TRENCH DAM IN TRENCH TO PREVENT GROUNDWATER MOVEMENT IN THE PIPE BEDDING. 100' SPACING MAXIMUM. SEE DETAIL.12"CL 6' MINIMUMD6"6"FOR GRASSED AREAS FOR PAVED or GRAVEL SURFACES 3/4" CRUSHED STONE OR SAND BEDDING WATER MAIN (SEE SITE PLAN FOR PIPE SIZE & MATERIAL) ALL BACKFILL TO BE COMPACTED IN 6" LIFTSSEE ROADWAYSECTION ORMATCH EXISTINGSEED AND MULCH, OVERFILL FOR SETTLEMENT GRADE AT 2:1 SLOPE WHEN DEPTH EXCEEDS 5' 24" WHERE 6' OF COVER CANNOT BE MAINTAINED, COVER WATER MAIN WITH 2" INSULATION BOARD, AND USE MINIMUM 2" INSULATION BOARD ON SIDES. AT ALL ROAD, DRIVE AND SIDEWALK (SURFACE) CROSSINGS INSTALL 2" INSULATION BOARD ON TOP AND SIDES AS SHOWN AND EXTEND 10' BEYOND SURFACE IN BOTH DIRECTIONS. INSULATION SHALL BE FULL WIDTH OF TRENCH. DETECTABLE METALLIC WARNING TAPE LABELED "WATER" 4"x4"x48" PRESSURE TREATED POST OR EQUIVALENT PLASTIC MARKER EVERY 200' AND AT ALL BENDS (GRASSED AREAS) PAINTED BLUE UNLESS INDICATED OTHERWISE BACKFILL FREE OF ORGANIC OR FROZEN MATERIAL. COMPACTED TO 90% DENSITY STANDARD PROCTOR IN GRASSED AREAS INITIAL 12" OF SELECT BACKFILL FREE OF ORGANIC OR FROZEN MATERIAL COMPACTED TO 95% DENSITY STANDARD PROCTOR IN GRASSED AREAS BACKFILL MATERIAL TO MATCH STRUCTURAL ROADWAY GRAVEL, SEE ROADWAY SECTION. COMPACTED TO 95% DENSITY STANDARD PROCTOR NOTES: 1.THE CONTRACTOR SHALL VERIFY THE PIPE MATERIAL TYPE AND SPECIFICATION WITH THE LOCAL WATER UTILITY BEFORE SUBMITTING SHOP DRAWINGS FOR, ORDERING, OR INSTALLING ANY WATER MAIN OR SERVICE. IF THERE IS ANY DISCREPANCY MATERIAL SPECIFICATION ON THE PLANS AND WHAT THE LOCAL WATER UTILITY REQUIRES, THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF THE CHANGE AND USE THE MATERIAL SPECIFIED BY SAID UTILITY. 2.LENGTH OF OPEN TRENCH SHALL BE KEPT TO A MINIMUM. 3.IF UNSUITABLE MATERIAL IS REMOVED BELOW BEDDING, REPLACE WITH MATERIAL APPROVED BY ENGINEER AND COMPACT TO 95% MAXIMUM DENSITY. 4.NO MECHANICAL TAMPERS SHALL BE USED DIRECTLY OVER PIPE TO INSURE PIPE IS NOT DAMAGED. 5.BEDDING TO PROVIDE FIRM, STABLE, CONTINUOUS AND UNIFORM SUPPORT FOR THE FULL LENGTH OF PIPE. 6.INSTALL WATER MAIN IN ACCORDANCE WITH MANUFACTURES GUIDELINES. 7.IF 6' OF COVER CAN NOT BE MAINTAINED DISCUSS WITH PROJECT ENGINEER AND TOWN (IF APPLICABLE) PRIOR TO INSTALLING. ADDITIONAL INSULATION OR OTHER MEASURES MAY BE REQUIRED DEPENDING ON COVER. 8.SUBMIT SHOP DRAWINGS PRIOR TO INSTALLATION. 9.IN NO CASE SHALL THE WATER MAIN BE BURIED LESS THAN 4 1/2 FEET BELOW FINISHED GRADE. W-001LAST REVISED 06/01/2017 PIPE OD + 24" W-010LAST REVISED 03/22/2017TRUDELL CONSULTING ENGINEERS PARALLEL WATER INSTALLATION WATER SEWERSTORMREQUIREMENTS: 1.WATER MAINS SHALL BE LAID AT LEAST 10' HORIZONTALLY FROM ANY EXISTING OR PROPOSED MANHOLE OR SANITARY SEWER. THIS DISTANCE CAN BE REDUCED TO 5' FOR STORM DRAINS. THE DISTANCE SHALL BE MEASURED EDGE OF PIPE TO TO EDGE OF PIPE. CONSULT WITH ENGINEER IF THESE SEPARATIONS ARE NOT AVAILABLE. 2.THE PROJECT ENGINEER SHALL PERIODICALLY OBSERVE THIS DURING CONSTRUCTION TO ENSURE PROPER SEPARATION AND THE CONTRACTOR SHALL SUPPLY AS-BUILTS REFERENCING PROPER SEPARATIONS. WSR APPENDIX SUBSECTION 8.6.2 5' MIN. 10' MIN. WN-001LAST REVISED 03/22/20172017 TRUDELL CONSULTING ENGINEERS TESTING WATER MAINS AND HYDRANTS *ALL TESTING SHALL BE PERFORMED IN THE PRESENCE OF THE TOWN ENGINEER OR PUBLIC WORKS DEPARTMENT IF APPLICABLE OR PRIVATE OWNER/OPERATOR AND PROJECT ENGINEER (AS DESIGNATED BY OWNER). CONTRACTOR SHALL PRE-TEST SUCCESSFULLY PRIOR TO CONTACTING PROJECT ENGINEER. THE PRE-TEST IS TO ENSURE PASSING RESULTS PRIOR TO OFFICIAL TESTING OBSERVATION. A.AFTER THE PIPE HAS BEEN LAID AND 7 DAYS AFTER THE CONCRETE THRUST BLOCKS AND ANCHORS HAVE BEEN PLACED, THE WATER MAIN SHALL BE HYDROSTATICALLY TESTED ACCORDING TO THE LATEST EDITION OF THE AWWA SPECIFICATION C-600. B.CONTRACTOR SHALL SUPPLY ALL NECESSARY APPARATUS TO PERFORM THE HYDROSTATIC TEST. C. TEST PRESSURE SHALL BE 200 POUNDS PER SQUARE INCH OR 1.5 TIMES THE WORKING PRESSURE MEASURED AT OR NEAR THE HIGH POINT IN THE SYSTEM, WHICHEVER IS GREATER. TEST SHALL BE A MINIMUM OF 2 HOURS IN DURATION. TESTING ALLOWANCE SHALL BE DEFINED AS THE VOLUME OF WATER THAT MUST BE SUPPLIED INTO THE NEWLY LAID PIPE OR ANY VALVED SECTION THEREOF TO MAINTAIN PRESSURE WITHIN 5 PSI (34.5 kPa) OF THE SPECIFIED TEST PRESSURE AFTER THE PIPE HAS BEEN FILLED WITH WATER AND THE AIR HAS BEEN EXPELLED. THE TESTING ALLOWANCE SHALL NOT EXCEED THE ALLOWABLE LEAKAGE (L) OR ELSE THE SECTION OF PIPE BEING TESTED WILL BE CONSIDERED FAILED. TESTING ALLOWANCE SHALL NOT BE MEASURED BY A DROP IN PRESSURE IN A TEST SECTION OVER A PERIOD OF TIME. REFER TO PIPE MANUFACTURERS RECOMMENDED TESTING PROCEDURE INCLUDING PIPE STABILIZATION PRIOR TO START OF TEST. D.THE PROJECT ENGINEER AND THE MUNICIPALITY SHALL BE CONTACTED 48 HOURS PRIOR TO TESTING. E.ALL VALVES SHOULD BE VERIFIED AS BEING OPEN OR CLOSED AS APPROPRIATE FOR THE PORTION OF THE WATER MAIN BEING TESTED. F.ALLOWABLE LEAKAGE SHALL BE COMPUTED BY THE FORMULA: L=(S x D x √P)/148,000 WHERE L IS LEAKAGE IN GALLONS PER HOUR, S IS THE LENGTH OF PIPE TESTED IN FEET, D IS THE NOMINAL DIAMETER OF THE PIPE IN INCHES AND P IS THE AVERAGE TEST PRESSURE IN POUNDS PER SQUARE INCH DURING THE TEST. G.REPLACE AND RETEST ANY WORK FOUND TO BE DEFECTIVE AFTER FAILED TEST AT NO EXPENSE TO OWNER AND RETEST UNTIL SYSTEM PASSES A.AFTER TESTING THE WATER MAINS, OPEN THE HYDRANT FULLY AND FILL WITH WATER. TO PREVENT CAPS FROM BEING BLOWN OFF, VENT AIR FROM ONE OF THE CAPS WHILE IT IS BEING FILLED. WHEN ALL THE AIR HAS ESCAPED, TIGHTEN THE CAP. B.ALLOW THE PRESSURE TO BUILD UP TO MAIN LINE PRESSURE AND CHECK FOR LEAKAGE AT FLANGES, NOZZLES AND THE OPERATING STEM. RECORD STATIC PRESSURE IN PSI. C.FLOW HYDRANT AND RECORD FLOW RATE IN GPM AND RESIDUAL PRESSURE IN PSI. D.CLOSE THE HYDRANT, REMOVE ONE NOZZLE CAP AND PLACE THE PALM OF YOUR HAND OVER THE OPENING. DRAINAGE SHOULD CREATE A NOTICEABLE SUCTION. IF NO SUCTION OR HYDRANT DOESN'T HAVE DRAIN, MANUALLY PUMP WATER OUT OF BARREL. E.AT PROJECT ENGINEER DISCRETION ASSIST WITH FLOW TESTING. ENGINEER TO RECORD STATIC AND RESIDUAL PRESSURE AS WELL AS FLOW RATE. TESTING WATER MAINS TESTING HYDRANTS (IF APPLICABLE) WN-003LAST REVISED 7/12/20132013 TRUDELL CONSULTING ENGINEERS DISINFECTION OF WATER SYSTEM *ALL TESTING SHALL BE PERFORMED IN THE PRESENCE OF THE TOWN ENGINEER OR PUBLIC WORKS DEPARTMENT AND PROJECT ENGINEER (AS DESIGNATED BY OWNER). A. PRIOR TO BEING PUT INTO SERVICE, WATER MAINS SHALL BE DISINFECTED ACCORDING TO THE LATEST EDITION OF AWWA SPECIFICATION C-651. THE TABLET METHOD IN AWWA STANDARD 651 IS NOT ACCEPTABLE. B. THE NEW LINE SHALL BE FLUSHED AT A VELOCITY OF NOT LESS THAN 2.5 FEET PER SECOND (OPEN 2-1/2 INCH HYDRANT CONNECTION). FLUSH FOR A PERIOD DETERMINED BY THE PROJECT ENGINEER FOR THE LENGTH OF MAIN TO BE DISINFECTED. C. CHLORINATION SHALL BE ACCOMPLISHED BY INTRODUCING A SODIUM HYPOCHLORITE SOLUTION FOR A RESULTANT CONCENTRATION OF GREATER THAN 25 PARTS PER MILLION OF FREE CHLORINE. D. USING A NOZZLE AT EACH END HYDRANT, CONTROL THE RATE OF FLOW INTO THE NEW MAIN AND PROPORTIONALLY FEED THE SODIUM HYPOCHLORITE SOLUTION INTO THE MAIN. AFTER THE SOLUTION HAS REACHED ALL POINTS IN THE SYSTEM, CLOSE THE VALVE SUPPLYING WATER FROM THE EXISTING MAIN AND THE END HYDRANTS. MAINTAIN THE HEAVILY CHLORINATED WATER IN THE MAIN FOR 24 HOURS DURING WHICH TIME ALL MAIN LINE VALVES SHOULD BE OPERATED. AFTER 24 HOURS THE MINIMUM CHLORINE RESIDUAL MUST BE AT LEAST 10 PARTS PER MILLION. E. FLUSH HEAVILY CHLORINATED WATER FROM THE LINE AND REFILL THE LINE FOR SERVICE (USE CHLORINE DIFFUSER). TAKE AND SUBMIT TWO BACTERIOLOGICAL SAMPLES (TAKEN 24 HOURS APART) OF THE WATER TO THE STATE OF VERMONT OR A STATE APPROVED TESTING LABORATORY. IF THE RESULTS ARE UNSATISFACTORY, THE DISINFECTION PROCEDURE WILL BE REPEATED UNTIL SATISFACTORY RESULTS ARE OBTAINED. F. FINISHED WATER STORAGE STRUCTURES SHALL BE DISINFECTED IF APPLICABLE, IN ACCORDANCE WITH CURRENT AWWA STANDARD C652. TWO OR MORE SUCCESSIVE SETS OF SAMPLES, TAKEN AT 24 HOUR INTERVALS, SHALL INDICATE MICROBIOLOGICALLY SATISFACTORY WATER BEFORE THE FACILITY IS PLACES INTO OPERATION. G. DISPOSAL OF HEAVILY CHLORINATED WATER FROM THE DISINFECTION PROCESS SHALL BE DE-CHLORINATED OR OTHERWISE HANDLED IN ACCORDANCE WITH THE REQUIREMENTS OF THE VERMONT AGENCY OF NATURAL RESOURCES. H. THE DISINFECTION PROCEDURE (AWWA CHLORINATION METHOD 3, SECTION 4.3 C652) WHICH ALLOWS USE OF THE CHLORINATED WATER HELD IN THE STORAGE TANK FOR DISINFECTION PURPOSES IS NOT RECOMMENDED. WHEN THAT PROCEDURE IS USED, IT IS REQUIRED THAT THE INITIAL HEAVILY CHLORINATED WATER BE PROPERLY DISPOSED IN ORDER TO PREVENT RELEASE OF WATER WHICH MAY CONTAIN VARIOUS CHLORINATED ORGANIC COMPOUNDS INTO THE DISTRIBUTION SYSTEM. DISINFECTING WATER MAINS AND SYSTEMS Sewer & Water Details C8-03 06/04/2020 Shown 19-202 RMP JAD    348 Bacon St. Properties, LLC 510 Shelburne Road South Burlington, Vermont WN-002LAST REVISED 9/10/20152015 TRUDELL CONSULTING ENGINEERS CONTRACTOR'S CERTIFICATION CONTRACTOR'S CERTIFICATION REQUIRED PRIOR TO THE DESIGN ENGINEER CERTIFYING THAT THE INSTALLATION HAS BEEN INSTALLED IN ACCORDANCE WITH THE PERMITTED DESIGN, THE CONTRACTOR SHALL PROVIDE A CERTIFICATION THAT THE WATER SYSTEM WAS INSTALLED AND TESTED IN ACCORDANCE WITH THE APPROVED DESIGN PLANS. STATE PERMITS REQUIRE THERE SHALL BE NO DEVIATIONS FROM THE APPROVED PLANS WITHOUT PRIOR APPROVALS. THE DESIGN ENGINEER SHALL BE NOTIFIED AND ALLOWED TO OBSERVE THE CRITICAL PHASES OF CONSTRUCTION INCLUDING ANY REQUIRED TESTS. LIKEWISE, THE DESIGN ENGINEER SHALL BE NOTIFIED OF ANY DEVIATIONS FROM THE APPROVED PLANS. SINCE THE DESIGN ENGINEER DOES NOT CUSTOMARILY OBSERVE ALL PHASES OF THE WORK, OR ALL TESTING, HE MAY RELY ON THE CONTRACTOR'S CERTIFICATION AS THE BASIS FOR FINAL CERTIFICATION. THE CONTRACTOR SHALL THEREFORE SIGN AND RETURN A COPY OF THE FOLLOWING CERTIFICATION UPON COMPLETION OF THE WORK: "I HEREBY CERTIFY THAT I HAVE INSTALLED, PROPERLY TESTED, AND SUCCESSFULLY PASSED THOSE TESTS, AND THE WATER SYSTEM(S) ARE BUILT IN ACCORDANCE WITH THE APPROVED DESIGN PLANS AND APPLICABLE PERMIT CONDITIONS." CONTRACTOR NAME: AUTHORIZED AGENTS NAME: SIGNATURE: DATE: NOTE ANY DEVIATIONS FROM APPROVED PLANS HERE: FOR POTABLE WATER SYSTEMS NOTE: THE CERTIFICATION AND THE PROJECT ENGINEER'S SUBSEQUENT CERTIFICATION DOES NOT VOID THE CONTRACTOR FROM REPAIR OR REPLACEMENT OF DISCREPANCIES DISCARDED AT A LATER DATE. THE CONTRACTOR REMAINS RESPONSIBLE, INCLUDING CUSTOMARY GUARANTEE AND WARRANTY PERIODS. W-007LAST REVISED 04/04/2016TRUDELL CONSULTING ENGINEERS TYPICAL TAPPING VALVE 6' MINIMUM WATER "WATER" CAST IN COVER PROVIDE WITH MUD PLUG FINISHED GRADE COATED CAST IRON TWO PIECE (SLIP TYPE) VALVE BOX WITH FLANGED TOP & LID. PROVIDE GATE BOX ALIGNER STAINLESS STEEL TAPPING SLEEVE OVER EXISTING WATER MAIN POWER SEAL 3490 MJ OR APPROVED EQUAL 3/4" STONE BEDDING 3/4" CORPORATION STOP FOR TESTING MUELLER B-25008 OR CAMBRIDGE BRASS MODEL 301NL (NO LEAD) GATE VALVE (AWWA C515) 4 MIL POLY BARRIER ALL FITTINGS ARE TO HAVE "MEGA-LUG" RETAINER GLANDS AND STAINLESS STEEL BOLTS AND NUTS CLASS D CONCRETE THRUST BLOCK (REFER TO THRUST BLOCK TABLE FOR SIZE) VALVE ANCHOR, 5 C.F. CLASS D CONCRETE USE # 4 BARS TO ANCHOR VALVE TO CONCRETE NOTES: 1.FOR MUNICIPAL CONNECTIONS CONTRACTOR TO APPLY TO TOWN WATER DEPARTMENT FOR WATER LINE TAPPING PERMIT. CONTRACTOR TO SUBMIT COMPLETE SPECIFICATION OF MATERIALS WITH PERMIT APPLICATION. IF PRIVATE WATER SYSTEM, CONTRACTOR IS TO COORDINATE ALL EFFORTS WITH PROJECT ENGINEER AND OWNER. 2.PRIOR TO INSTALLATION SUBMIT SHOP DRAWINGS ON MATERIAL AND INSTALLATION PROCEDURE. 3.INSTALL IN ACCORDANCE WITH LATEST STANDARD PRACTICE, MANUFACTURE GUIDELINES AND TOWN SPECIFICATION (IF APPLICABLE). 4.PROJECT ENGINEER AND TOWN (IF APPLICABLE) TO BE GIVEN 48 HOURS NOTICE (MINIMUM) OF TAP. 5.CONTRACTOR TO REVIEW WITH PROJECT ENGINEER, TOWN (IF APPLICABLE) AND OWNER CONTINGENCY PLANS IN THE EVENT OF A BREAK PRIOR TO STARTING.WATER MAIN W-005LAST REVISED 04/05/2016TRUDELL CONSULTING ENGINEERS TYPICAL WATER MAIN THRUST BLOCKS 2", 3" & 4"SAFE BEARING LOAD LBS/FT.² GRAVEL SHALE SOIL TYPE CLAY SAND TILL 10000 1000 2000 3000 4000 5.0 2.5 2.0 1.5 0.5 90° 7.0 3.5 2.5 2.0 1.0 45° 14.0 7.0 5.0 3.5 1.5 45° 8.0 4.0 3.0 2.0 1.0 10.5 5.5 3.5 3.0 1.0 22.5°45° 4.0 2.0 1.5 1.0 0.5 2.0 1.0 1.0 0.5 0.5 15.0 7.5 5.0 4.0 1.5 6" 90° 18.0 9.0 6.0 4.5 2.0 22.5° 4.0 2.0 1.5 1.0 0.5 90° 25.0 13.0 8.5 6.5 2.5 8" 2.0 5.0 7.0 10.0 21.0 3.0 7.0 9.0 14.0 28.0 22.5° 7.0 3.5 2.5 2.0 1.0 3.5 9.5 12.5 19.0 38.0 90° 10" 45° 1.0 2.5 4.5 5.0 10.5 22.5° 39.0 20.0 13.0 10.0 4.0 12" 90° 55.0 27.5 18.5 14.0 5.5 45° 30.0 15.0 10.0 7.5 3.0 22.5° 15.0 8.0 5.0 4.0 1.5 USE CLASS D (2500 PSI) CONCRETE FOR THRUST BLOCKS. PLACE 4 MIL. POLYETHYLENE BETWEEN FITTING AND THRUST BLOCK. PLACE THRUST BLOCK AGAINST UNDISTURBED TRENCH WALL - CONCRETE BEARING AREA ON FITTING TO BE A MINIMUM OF 1/2 SQUARE FOOT. THRUST BLOCKS BASED ON 200 PSI WORKING PRESSURE PLUS SURGE ALLOWANCE OF 100 PSI. IF GREATER THAN 200 PSI SEE PROJECT ENGINEER FOR SIZE. 90° ELBOW TEE 22 ½ ° ELBOW 45° ELBOW TRENCH WALL, TYPICAL UNDISTURBED SOIL, TYPICAL EXTEND 6" INTO TRENCH WALL NOTE: 1.FOR REDUCERS, PROVIDE BEARING AREA FOR THE SOIL TYPE BASED ON 4000 LBS FOR EACH 2" REDUCTION IN SIZE. 2.PROJECT ENGINEER TO OBSERVE ALL THRUST BLOCKS PRIOR TO BACKFILL. PICTURES MAY BE USED AT ENGINEERS DISCRETION. 3.ALSO INCLUDE RETAINER GLANDS ON ALL BENDS, TEES, CAPS ETC. MINIMUM BEARING AREA IN SQUARE FEET ON UNDISTURBED TRENCH WALLTHRUST BLOCK TABLE CAP W/ MECH. JOINT CAP REDUCER OR TEE CAP OR TEE CAP OR TEE CAP OR TEE CAP OR TEE CAP W-004LAST REVISED 02/02/2018TRUDELL CONSULTING ENGINEERS TYPICAL WATER/SEWER CROSSING LC WATER SEWER REQUIREMENTS: 1.WATER MAINS CROSSING SEWERS SHALL BE LAID TO PROVIDE A MINIMUM VERTICAL DISTANCE OF 18 INCHES BETWEEN THE OUTSIDE OF WATER MAIN AND THE OUTSIDE OF SEWER. THIS SHALL BE THE CASE WHERE THE WATER MAIN IS EITHER ABOVE OR BELOW THE SEWER. AT CROSSINGS, ONE FULL LENGTH OF WATER PIPE SHALL BE LOCATED SO BOTH JOINTS WILL BE AS FAR FROM THE SEWER AS POSSIBLE. IF THE SEWER MAIN IS OVER THE WATER MAIN, THE FIRST SEWER PIPE JOINTS ON EACH SIDE OF THE WATER MAIN MUST BE CONCRETE ENCASED. SPECIAL STRUCTURAL SUPPORT FOR THE WATER AND SEWER PIPES MAY BE REQUIRED. WATER MAINS SHALL NOT PASS THROUGH SEWER MANHOLES OR BE SUBMERGED IN BASINS CONTAINING SEWAGE OR OTHER GROSSLY CONTAMINATED OR HAZARDOUS MATERIAL. 2.THE PROJECT ENGINEER SHALL OBSERVE ALL CROSSINGS, PRIOR TO BACKFILL. 3.ANY DEVIATION TO THIS MINIMUM REQUIREMENT IS SUBJECT TO REVIEW AND APPROVAL OF REGULATORY AUTHORITIES. 4.PRIOR TO CROSSING THE CONTRACTOR SHALL SUPPLY INVERT OF SEWER TO PROJECT ENGINEER. INVERT COMPACTED CRUSHED STONE BACKFILL IN 6" LIFTS18" MIN.W-018 1"=1' LAST REVISED 03/22/2017TRUDELL CONSULTING ENGINEERS 21.0 10.0 7.0 5.0 2.0 10" MIN. BEARING AREA (SQ.FT.) ON UNDISTURBED TRENCH WALL FOR 45° BENDS SAFE BEARING LOAD LBS/FT CLAY SAND GRAVEL TILL SHALE SOIL TYPE 1000 2000 3000 4000 10000 8.0 4.0 3.0 2.0 1.0 6" 14.0 7.0 5.0 3.5 1.5 8"WA T E R M A I N 30.0 15.5 10.5 7.5 3.0 12" NOTES: 1.THRUST BLOCK BASED ON 200 P.S.I. WORKING PRESSURE PLUS SURGE ALLOWANCE OF 100 P.S.I., IF GREATER THAN 200 P.S.I SEE PROJECT ENGINEER FOR SIZE. 2.PROJECT ENGINEER TO OBSERVE ALL THRUST BLOCKS PRIOR TO BACKFILL. PICTURE MAY BE USED AT ENGINEERS DISCRETION. 3.PROVIDE RETAINER GLANDS AT BEND WITH THRUST BLOCK. UNDISTURBED SUBGRADE MECHANICAL JOINT ELBOW #4 REBAR AROUND ELBOW AND ANCHORED WITH CONCRETE CLASS D (2500) P.S.I CONCRETE THRUST BLOCK. USE CHART TO DETERMINE REQUIRED BEARING AREA SELECT BEDDING FILL UNDER PIPE SEE DETAIL SELECT BACKFILL OVER PIPE SEE DETAIL USE 5 MIL POLYETHYLENE BETWEEN THRUST BLOCK AND PIPE (TYPICAL) TYPICAL THRUST BLOCK FOR VERTICAL BENDS S-005 1"=1'-0" LAST REVISED 3/5/2013TRUDELL CONSULTING ENGINEERS MANHOLE CHANNEL GEOMETRYFLOW DIRECTIONFLOW 90° MAX PLAN VIEW PRECAST CONCRETE MANHOLE 2'-0" RADIUS, MINIMUM S-027 1"=1' LAST REVISED 02/28/2020TRUDELL CONSULTING ENGINEERS TYPICAL SEWER CLEANOUTSEWER COVER WITH LIFT HOLE GENERAL FOUNDRY MODEL 11181 OR EQUAL (PLAN VIEW) CAST IRON CLEANOUT RING AND COVER 4" PVC SDR 35 RISER 4" PVC SDR 35 ELBOW 4"x4"x4" or 6"x6"x4" PVC SDR 35 45° WYE 4" OR 6" SDR 35 PVC PIPE SEE SITE PLAN FOR SIZE 4" or 6"FLOW FLOW LAWN PROVIDE THREADED PVC CAP EXISTING SOIL Sheet Title Project Title Use of These Drawings Scale: Project Number: Date: Drawn By: Project Engineer: Approved By: No. Description Date By Revisions 478 BLAIR PARK ROAD | WILLISTON, VERMONT 05495 802 879 6331 | WWW.TCEVT.COM ENGINEERING SURVEY No. 8917 CIVIL PROF ESSIONAL E N G INEERLICE N S E DJENNIFER ANN DESA U T ELSSTA TE O F VER M ONT Field Book: 1. Unless otherwise noted, these Drawings are intended for preliminary planning, coordination with other disciplines or utilities, and/or approval from the regulatory authorities.  They are not intended as construction drawings unless noted as such or marked approved by a regulatory authority. 2. By use of these drawings for construction of the Project, the Owner represents that they have reviewed, approved, and accepted the drawings, obtained all necessary permits, and have met with all applicable parties/disciplines, including but not limited to, the Engineer and the Architect, to insure these plans are properly coordinated including, but not limited to, contract documents, specifications, owner/contractor agreements, building and mechanical plans, private and public utilities, and other pertinent permits for construction. 3. Owner and Architect, are responsible for final design and location of buildings shown, including an area measured a minimum five (5) feet around any building and coordinating final utility connections shown on these plans. 4. Prior to using these plans for construction layout, the user shall contact TCE to ensure the plan contains the most current revisions. 5. These Drawings are specific to the Project and are not transferable. As instruments of service, these drawings, and copies thereof, furnished by TCE are its exclusive property.  Changes to the drawings may only be made by TCE. If errors or omissions are discovered, they shall be brought to the attention of TCE immediately. 6. It is the User's responsibility to ensure this copy contains the most current revisions. PLANNING ENVIRONMENTAL E-001 N.T.S. LAST REVISED 3/15/20172017 TRUDELL CONSULTING ENGINEERS TEMPORARY SOIL STOCKPILE EROSION PROTECTION NOTES: 1.INSTALL SILT FENCE ALONG CONTOUR ON DOWNSLOPE SIDE OF STOCKPILE. COMPLETELY ENCLOSE STOCKPILE ON FLAT SITES. SILT FENCE TO REMAIN IN PLACE UNTIL MATERIAL IS REMOVED AND AREA IS STABILIZED. 2.A MINIMUM OF 5' SEPARATION BETWEEN THE TOE OF THE STOCKPILE SLOPE AND THE SILT FENCE IS REQUIRED AT ALL TIMES 5' TO 10' SILT FENCE 2 1 5' TO 10' SILT FENCE MAINTAIN VEGETATED COVER SOIL STOCKPILE E-003 N.T.S. LAST REVISED 3/11/20132013 TRUDELL CONSULTING ENGINEERS TEMPORARY VEGETATED SWALE 2.0' Min.3H:1V NOTE: Ditches < 5% - Reinforce with SC-150BN Ditches > 5% - Reinforce with VMax C-350BN Ditches > 20% - Reinforce with VMax P550 Installed per Manufacturer Requirements 2.0' Construction Specifications for Vegetated Swales 1. All trees, brush, stumps, obstructions, and other objectionable material shall be removed and disposed of so as not to interfere with the proper functioning of the waterway. 2. The waterway shall be excavated or shaped to line, grade, and cross section as required to meet the criteria specified herein, and be free of bank projections or other irregularities which will impede normal flow. 3. Fills shall be compacted as needed to prevent unequal settlement that would cause damage in the complete waterway. 4. All earth removed and not needed in construction shall be spread or disposed of so that it will not interfere with the functioning of the waterway. 5. Stabilization shall be done according to the appropriate standard and specifications for vegetative practices. A. For design velocities of less than 3.5 fps, seeding and mulching may be used for the establishment of the vegetation. It is recommended that, when conditions permit, temporary waterways or other means should be used to prevent water from entering the waterway during the establishment of vegetation. B. For design velocities of more than 3.5 fps, the waterway shall be stabilized with sod, with seeding protected by jute or other matting or with seeding and mulching including temporary diversion of the water until the vegetation is established. ESTABLISH GRASS SC-2 Erosion Details C8-04 06/04/2020 Shown 19-202 RMP JAD    348 Bacon St. Properties, LLC 510 Shelburne Road South Burlington, Vermont E-004LAST REVISED 6/12/20132013 TRUDELL CONSULTING ENGINEERS STABILIZED CONSTRUCTION ENTRANCE CONSTRUCTION SPECIFICATIONS 1.STONE SIZE - USE 4-8" CRUSHED STONE, OR RECLAIMED OR RECYCLED CONCRETE EQUIVALENT. 2.LENGTH - NOT LESS THAN 50' (EXCEPT ON A SINGLE RESIDENCE LOT WHERE A 30' MINIMUM LENGTH APPLIES). 3.THICKNESS - NOT LESS THAN 8". 4.WIDTH - TWELVE (12) FOOT MINIMUM, BUT NOT LESS THAN THE FULL WIDTH AT POINTS WHERE INGRESS OR EGRESS OCCURS. TWENTY-FOUR (24) FOOT IF SINGLE ENTRANCE TO SITE. 5.GEOTEXTILES MUST BE PLACED OVER THE ENTIRE AREA PRIOR TO PLACING OF STONE. 6.SURFACE WATER - ALL SURFACE WATER FLOWING OR DIVERTED TOWARDS CONSTRUCTION ENTRANCES SHALL BE PIPED BENEATH THE ENTRANCE. IF PIPING IS IMPRACTICAL, A MOUNTABLE BERM WITH 5:1 SLOPES WILL BE PERMITTED. 7.MAINTENANCE - THE ENTRANCE SHALL BE MAINTAINED IN A CONDITION WHICH WILL PREVENT TRACKING OR FLOWING OF SEDIMENT ONTO PUBLIC RIGHTS-OF-WAY, ALL SEDIMENT SPILLED, DROPPED, WASHED OR TRACKED ONTO PUBLIC RIGHTS-OF-WAY MUST BE REMOVED IMMEDIATELY AND DISPOSED OF IN ACCORDANCE WITH THE EPSC PLANS. (i.e. PLACED IN A SOIL STOCKPILE OR AREA WHERE IT CAN BE STABILIZED PER EPSC DETAILS). IF SWEEPING IS THE CHOSEN METHOD FOR REMOVAL THE SWEPT MATERIAL MUST BE COLLECTED AND DISPOSED OF AS STATED ABOVE. 8.WHEN WASHING IS REQUIRED, IT SHALL BE DONE ON AN AREA STABILIZED WITH STONE AND WHICH DRAINS INTO AN APPROVED SEDIMENT TRAPPING DEVICE. 9.PERIODIC INSPECTION AND NEEDED MAINTENANCE SHALL BE PROVIDED ACCORDING TO PERMIT REQUIREMENTS BASED ON SITE CONDITIONS, WEATHER AND FLOW OF TRAFFIC. PUBLIC ROADWAY PROFILE EXCAVATION SITE PLAN SEE CONSTRUCTION SPECIFICATION 4 4-8" CRUSHED STONE AGGREGATE PLACED ON GEOTEXTILE FABRIC 4" ABOVE EXISTING GRADE 4" BELOW EXISTING GRADE 50'VARIESR=12'8"EXCAVATION SITE EXISTING GRADE GEOTEXTILE FABRIC SD-038 3/8" = 1'-0" LAST REVISED 08/09/20132013 TRUDELL CONSULTING ENGINEERS TYPICAL GALVANIZED FENCE WITH GATE 10' MAX. GALVANIZED FENCE WITH GREEN SLATS CENTER POST GATE STOP HINGED GATE PANEL 10' MAX. POST FOOTING TYPICAL HEIGHT VARIES(REFER TO SITE PLAN)GROUND LINE EN-001LAST REVISED 03/11/2013TRUDELL CONSULTING ENGINEERS SEEDING - 85 90 80 85 GERMINATION 0-5 0-5 25-30 30-40 30-40 WEIGHT (POUNDS PER ACRE) WHITE CLOVER RED TOP PERENNIAL RYE KENTUCKY BLUEGRASS CREEPING RED FESCUE COMMON NAME MOLDY WILL NOT BE ACCEPTABLE. THE FOLLOWING SEED MIXTURE SHALL BE USED: SEED SHALL BE FRESH, CLEAN, NEW SEED. SEED WHICH HAS BECOME WET AND/OR AFTER THE FINISHED GRADE HAS BEEN ESTABLISHED AND THE FERTILIZER SPREAD, PLANT THE SPECIFIED SEED MIXTURE AT A RATE OF 4 POUNDS PER 1000 SQUARE FEET AND WORK FIRMLY INTO THE SOIL. APPLY SEED ON THE PREPARED SEED BED WITH APPROVED MECHANICAL SEEDERS OR HYDROSEEDING EQUIPMENT. UPON COMPLETION OF THE ABOVE PLANTING OPERATIONS, ROLL ALL AREAS WITH A WATER FILLED GARDEN ROLLER, LEAVING THE SURFACE OF ALL AREAS TRUE TO GRADE, SMOOTH, AND FREE FROM HOLLOWS OR OTHER IRREGULARITIES. THOROUGHLY WATER ALL NEWLY PLANTED LAWNS IMMEDIATELY AFTER PLANTING, USING A FINE SPRAY. PROTECT BANKS AND SWALES, AND PREVENT OR REPAIR EROSION THAT OCCURS. BANKS, SWALES OR OTHER GRADED AREAS THAT HAVE BEEN WASHED OUT OR HAVE BECOME DAMAGED SHALL BE REPAIRED IMMEDIATELY. UNLESS APPROVAL IS GRANTED BY THE ENGINEER TO PLANT OFF SEASON, SEEDING WILL BE CONDUCTED ONLY DURING THE PERIOD FROM APRIL 15 TO JUNE 1 OR AUGUST 15 TO OCTOBER 15. SO AS NOT TO CAUSE INTERFERENCE, NO SEEDING IS TO PROCEED BEFORE OTHER PHASES OR THE WORK HAS PROGRESSED SUFFICIENTLY. EN-006LAST REVISED 4/9/2013TRUDELL CONSULTING ENGINEERS STABILIZATION REQUIREMENTS ALL AREAS OF DISTURBANCE MUST HAVE TEMPORARY OR FINAL STABILIZATION WITHIN SEVEN DAYS OF THE INITIAL DISTURBANCE. AFTER THIS TIME, ANY DISTURBANCE IN THE AREA MUST BE STABILIZED AT THE END OF EACH WORK DAY. THE FOLLOWING EXCEPTIONS APPLY: 1. STABILIZATION IS NOT REQUIRED IF WORK IS TO CONTINUE IN THE AREA WITHIN THE NEXT 24 HOURS AND THERE IS NO PRECIPITATION FORECAST FOR THE NEXT 24 HOURS. 2.STABILIZATION IS NOT REQUIRED IF THE WORK IS OCCURRING IN A SELF-CONTAINED EXCAVATION (I.E. NO OUTLET) WITH A DEPTH OF 2 FEET OR GREATER (E.G. HOUSE FOUNDATION EXCAVATION, UTILITY TRENCHES) STABILIZATION IS TO BE ACCOMPLISHED IN ACCORDANCE WITH DETAILS SHOWN. EN-010LAST REVISED 06/13/2013TRUDELL CONSULTING ENGINEERS GRADING OF 1/2 INCH WHEN TESTED WITH A 10 FOOT STRAIGHTEDGE. COMPACT AS SPECIFIED TO THE REQUIRED ELEVATION. PROVIDE FINAL GRADES WITHIN A TOLERANCE C. GRADING SURFACE OF FILL UNDER BUILDING SLABS: GRADE SMOOTH AND EVEN, FREE OF VOIDS, AND PONDING OCCURS, THE PAVING WILL BE UNACCEPTABLE. SUBGRADE ELEVATION. PAVEMENTS MUST DRAIN SO THAT NO WATER PONDING OCCURS. IF SECTION, WITH THE FINISH SURFACE NOT MORE THAN 0.10 FEET ABOVE OR BELOW THE REQUIRED 3. PAVEMENTS: SHAPE THE SURFACE OF AREAS UNDER PAVEMENTS TO LINE, GRADE AND CROSS- ELEVATION. WITH FINISH SURFACES NOT MORE THAN 0.10 FEET ABOVE OR BELOW THE REQUIRED SUBGRADE 2. WALKS: SHAPE THE SURFACE OF AREAS UNDER WALKS TO LINE, GRADE AND CROSS-SECTION, PONDING OCCURS. THE GRADING OF LAWNS WILL BE UNACCEPTABLE IF PONDING OCCURS. ABOVE OR BELOW THE REQUIRED SUBGRADE ELEVATIONS. LAWNS SHALL BE GRADED SO THAT NO 1. LAWN OR UNPAVED AREAS: FINISH AREAS THAT ARE TO RECEIVE TOPSOIL TO WITHIN 0.10 FEET FINISH SURFACES FREE FROM IRREGULAR SURFACE CHANGES, AND AS FOLLOWS: FROM THE STRUCTURES AND TO PREVENT PONDING. B. GRADING OUTSIDE BUILDING LINES: GRADE AREAS ADJACENT TO BUILDING LINES TO DRAIN AWAY POINTS AND EXISTING GRADES. UNIFORM LEVELS OR SLOPES BETWEEN POINTS WHERE ELEVATIONS ARE INDICATED, OR BETWEEN SUCH TRANSITION AREAS. SMOOTH FINISHED SURFACES WITHIN THE SPECIFIED TOLERANCES, COMPACT WITH A. GENERAL: UNIFORMLY GRADE AREAS WITHIN THE LIMITS OF GRADING, INCLUDING ADJACENT EN-005LAST REVISED 3/11/2013TRUDELL CONSULTING ENGINEERS GENERAL CONSTRUCTION SEQUENCE 1. INSTALL BARRIER TAPE. 2. INSTALL CONSTRUCTION ENTRANCE AS SPECIFIED IN PHASE. 3. INSTALL SILT FENCE IN LOCATION SHOWN ON PLANS AS DETAILED. 4. STAKE OUT CONSTRUCTION, CLEAR AND GRUB. 5. STOCK PILE, PROCESS, AND DISPOSE OF TREES. 6. CONSTRUCT NECESSARY STABILIZED CONSTRUCTION ROADS, ESTABLISH DITCHLINES FROM DOWNHILL TO UPHILL, INSTALL CHECK DAMS AND EROSION CONTROL FABRIC IN DITCHLINES AS DETAILED. MAINTAIN TRAFFIC FLOW AS SHOWN. 7. CONSTRUCT SITE FEATURES. 8. VEGETATE AND STABILIZE AS NECESSARY WITHIN SEVEN DAYS. 9. RECEIVE APPROVAL FROM ON-SITE CO-ORDINATOR PRIOR TO MOVING TO NEXT PHASE. TRUDELL CONSULTING ENGINEERS SILT FENCE WITH WIRE REINFORCEMENT16"20"MIN.MIN.(MIRAFI ENVIROFENCE, OR APPROVED EQUAL MAY BE SUBSTITUTED.) FILTER FABRIC, OR WOVEN WIRE FABRIC WOODEN OR METAL STAKE (MAX. 10' O.C.) KEY FABRIC INTO GROUND (MIN. 6") FLOW CONSTRUCTION SPECIFICATION FOR SILT FENCE 1.WOVEN WIRE FENCE TO BE FASTENED SECURELY TO FENCE POSTS WITH WIRE TIES. WIRE FENCE REINFORCEMENT REQUIRED WITHIN 100 FT UPSLOPE OF RECEIVING WATERS. 2.FILTER CLOTH TO BE FASTENED SECURELY TO WOVEN WIRE FENCE WITH TIES SPACED EVERY 24" AT TOP AND MID SECTION. FENCE SHALL BE WOVEN WIRE, 6" MAXIMUM MESH OPENING. 3.WHEN TWO SECTIONS OF FILTER CLOTH ADJOIN EACH OTHER THEY SHALL BE OVERLAPPED BY SIX INCHES AND FOLDED. FILTER CLOTH SHALL BE EITHER FILTER X, MIRAFI 100X, STABILINKA T140N, OR APPROVED EQUIVALENT. 4.PREFABRICATED UNITS SHALL BE GEOFAB, ENVIROFENCE, OR APPROVED EQUIVALENT. 5.MAINTENANCE SHALL BE PERFORMED AS NEEDED AND MATERIAL REMOVED WHEN SEDIMENT REACHED HALF OF FABRIC HEIGHT.6"WIRE REINFORCEMENT E-104LAST REVISED 2/10/2016 Sheet Title Project Title Use of These Drawings Scale: Project Number: Date: Drawn By: Project Engineer: Approved By: No. Description Date By Revisions 478 BLAIR PARK ROAD | WILLISTON, VERMONT 05495 802 879 6331 | WWW.TCEVT.COM ENGINEERING SURVEY No. 8917 CIVIL PROF ESSIONAL E N G INEERLICE N S E DJENNIFER ANN DESA U T ELSSTA TE O F VER M ONT Field Book: 1. Unless otherwise noted, these Drawings are intended for preliminary planning, coordination with other disciplines or utilities, and/or approval from the regulatory authorities.  They are not intended as construction drawings unless noted as such or marked approved by a regulatory authority. 2. By use of these drawings for construction of the Project, the Owner represents that they have reviewed, approved, and accepted the drawings, obtained all necessary permits, and have met with all applicable parties/disciplines, including but not limited to, the Engineer and the Architect, to insure these plans are properly coordinated including, but not limited to, contract documents, specifications, owner/contractor agreements, building and mechanical plans, private and public utilities, and other pertinent permits for construction. 3. Owner and Architect, are responsible for final design and location of buildings shown, including an area measured a minimum five (5) feet around any building and coordinating final utility connections shown on these plans. 4. Prior to using these plans for construction layout, the user shall contact TCE to ensure the plan contains the most current revisions. 5. These Drawings are specific to the Project and are not transferable. As instruments of service, these drawings, and copies thereof, furnished by TCE are its exclusive property.  Changes to the drawings may only be made by TCE. If errors or omissions are discovered, they shall be brought to the attention of TCE immediately. 6. It is the User's responsibility to ensure this copy contains the most current revisions. PLANNING ENVIRONMENTAL Stormwater & Site Details C8-05 06/04/2020 Shown 19-202 RMP JAD    348 Bacon St. Properties, LLC 510 Shelburne Road South Burlington, Vermont SW-001 1" = 1' LAST REVISED 03/22/2017TRUDELL CONSULTING ENGINEERS TYPICAL STORM DRAIN TRENCH 1' FINISHED ROAD GRADE D + 8"1' NOTES ON STORM DRAIN TRENCH: A WET TRENCH SHALL BE DEWATERED PRIOR TO INSTALLING BEDDING DEPTH OF STORM DRAIN LINES VARY, REFER TO PLANS FOR DEPTH IN APPROPRIATE LOCATIONS. D FOR PAVED SURFACES VARIES(SEE PAVEMENT SECTION)FOR GRASSED AREAS REPLACE TOPSOIL, SEED, AND MULCH OVERFILL TO ALLOW FOR SETTLEMENT. THOROUGHLY COMPACTED SELECTED BACKFILL FROM TRENCH EXCAVATION, FREE OF STONES LARGER THAN 3" IN DIAMETER. COMPACT BACKFILL IN 6" LIFTS. STORM DRAIN, (SEE SITE PLAN FOR PIPE SIZE & MATERIAL) THOROUGHLY COMPACTED 3/4" CRUSHED STONE BEDDING FOR CMP, PVC, OR HDPE PIPE. UNDISTURBED SOIL SW-005 1/2" = 1' LAST REVISED 08/08/2014TRUDELL CONSULTING ENGINEERS TYPICAL STORMWATER MANHOLE MAXIMUM PIPE SIZE MANHOLE NOTES 1.IF DEPTH OF MANHOLE IS 7 FEET OR LESS FROM RIM TO CENTERLINE INVERT, THEN A FLAT TOP WILL BE INSTALLED. IF DEPTH IS MORE THAN 7 FEET, THEN A CONICAL TOP WILL BE INSTALLED. 2.ADJUST RIM AS NEEDED TO MATCH FINAL PAVEMENT.6"48"VARIES12" INCREMENTS8"32" MIN.56" MAX.12"STORM DRAIN LINE 24" OPENING4"36"5" HEAVY DUTY FRAME & LID LABELED "DRAIN" NEENAH R-1649 OR LEBARON LC 266 GROUT FRAME TO 4 INCHES FROM TOP PRECAST CONCRETE ADJUSTMENT RING SECTION MINIMUM 4 INCHES, MAXIMUM 12 INCHES ECCENTRIC CONICAL TOP SECTION COPOLYMER POLYPROPYLENE LADDER RUNGS 12" O.C. BUTYL JOINT SEALANT WELDED WIRE FABRIC (6 X 6 WWF) RUBBER BOOT (PRESS SEAL PSX) #4 BARS, 12" O.C., BOTH WAYS 12" GRAVEL OR 1" STONE FOR SUB-BASE OR AS REQUIRED BY ENGINEER IF WET AND OR UNSTABLE CONDITIONS EXIST. UNDISTURBED SOIL 30" PVC 24" RCP,CSP,CAAP,CPEP SW-008LAST REVISED 05/06/2014TRUDELL CONSULTING ENGINEERS TYPICAL YARD DRAIN CAST IRON LIGHT DUTY RATED GRATE 24" DRAIN BASIN BY NYLOPLAST OR APPROVED EQUAL 6" CRUSHED STONE OR AS REQUIRED BY ENGINEER FOR USE WITH VARIOUS TYPES OF OUTLETS WITH WATERTIGHT ADAPTERS SDR-35 SEWER A-2000 CORRUGATED PVC ULTRA RIB PVC CORRUGATED POLYETHYLENE ADAPTER OUTLET PIPEVARIES SW-040 1/2" = 1' LAST REVISED 03/10/2020TRUDELL CONSULTING ENGINEERS STORMWATER CONNECTION TO EXISTING DRAIN MANHOLE 5" SET CORE AND GASKET SEAL TO PLACE PIPE INVERT AT TABLE LEVEL 48" DIA. NEW STORM DRAIN POSITIVE SEAL GASKET SYSTEM WITH POWER SLEEVE EXPANSION. ENGINEER TO OBSERVE CONNECTION. EXISTING STORM DRAIN NOTE: SEE SITE PLAN FOR CORE LOCATION, PIPE SIZE AND INVERT. REFORM OR RE-BUILD INVERTS AS NEEDED TAKE MEASURES TO ENSURE CONNECTIONS ARE WATER TIGHT GRAVEL BACKFILL AROUND STRUCTURE COMPACTED IN 6" LIFTS TO 95% DENSITY STANDARD PROCTOR, UNLESS INDICATED OTHERWISE SWN-002LAST REVISED 08/17/2015TRUDELL CONSULTING ENGINEERS CONTRACTOR CERTIFICATION FOR STORMWATER SYSTEM PRIOR TO THE DESIGN ENGINEER CERTIFYING THAT THE INSTALLATION HAS BEEN INSTALLED IN ACCORDANCE WITH THE PERMITTED DESIGN, THE CONTRACTOR SHALL PROVIDE A CERTIFICATION THAT THE STORMWATER SYSTEM WAS INSTALLED AND TESTED (IF APPLICABLE)IN GENERAL ACCORDANCE WITH THE APPROVED DESIGN PLANS. STATE PERMITS REQUIRE THERE SHALL BE NO SIGNIFICANT DEVIATIONS FROM THE APPROVED PLANS WITHOUT PRIOR APPROVALS. THE DESIGN ENGINEER SHALL BE NOTIFIED AND ALLOWED TO OBSERVE THE CRITICAL PHASES OF CONSTRUCTION INCLUDING ANY REQUIRED TESTS. LIKEWISE, THE DESIGN ENGINEER SHALL BE NOTIFIED OF ANY DEVIATIONS FROM THE APPROVED PLANS. SINCE THE DESIGN ENGINEER DOES NOT CUSTOMARILY OBSERVE ALL PHASES OF THE WORK, OR ALL TESTING, HE WILL RELY ON THE CONTRACTOR'S CERTIFICATION AS THE BASIS FOR FINAL CERTIFICATION. CRITICAL STORMWATER SYSTEM COMPONENTS TO BE CERTIFIED MAY INCLUDE, BUT ARE NOT NECESSARILY LIMITED TO, SHAPES OF DRAINAGE SWALES, VOLUMES OF TREATMENT PRACTICES, SLOPE OF DISCONNECT AREAS, AND OUTLET SIZE AND ELEVATIONS. THE CONTRACTOR SHALL SHALL THEREFORE SIGN AND RETURN A COPY OF THE FOLLOWING CERTIFICATION UPON COMPLETION OF THE WORK: "I HEREBY CERTIFY THAT I HAVE INSTALLED, PROPERLY TESTED (IF APPLICABLE), AND SUCCESSFULLY PASSED THOSE TESTS, AND THE STORMWATER TREATMENT AND COLLECTION SYSTEM(S) ARE BUILT IN GENERAL ACCORDANCE WITH THE APPROVED DESIGN PLANS AND APPLICABLE PERMIT CONDITIONS." CONTRACTOR NAME AUTHORIZED AGENTS NAME SIGNATURE DATE NOTE ANY DEVIATIONS FROM APPROVED PLANS HERE: CONTRACTOR'S CERTIFICATION REQUIRED GUTTER DOWNSPOUT (BY OTHERS) 6" Ø HDPE PIPE, TYP. UNLESS OTHERWISE NOTED TO DRAINAGE STRUCTURE OR PIPE CONNECTION FINISH GRADE PROVIDE DOWNSPOUT ADAPTER OR CAP AT GRADE FOR DOWNSPOUT CONNECTION PROVIDE AT GRADE CLEANOUT WITH CAP AT PIPE ANGLES, TEES, AND WYES 4' MIN. SW-009 TYPICAL GUTTER DOWNSPOUT CONNECTION 2014 TRUDELL CONSULTING ENGINEERS LAST REVISED 04/21/2014 SW-031LAST REVISED 04/08/2018TRUDELL CONSULTING ENGINEERS PEA STONE DIAPHRAGM REFER TO TYPICAL SIDWALK DETAIL 12 X 24 INCH PEA STONE DIAPHRAGM ASTM D 448 OR EQUIVALENT FILTER FABRIC MIRAFI 140N OR EQUIVALENT WRAP FABRIC 6" BELOW GRADE 24"12"6"SLOPE 1 2 1 2 6" PERFORATED UNDERDRAIN WRAPPED IN FILTER FABRIC BIORETENTION AREA #1 INV = 206.3 BIORETENTION AREA #2 INV = 206.25 1" STONE LAYER FILTER FABRIC BETWEEN SOIL AND STONE 2.0' BIORETENTION SOIL LAYER (SEE SITE PLAN FOR SOIL AREA) BIORETENTION MIX 85-88% SAND 8-12% SILT 0-2% CLAY 3-5% ORGANIC MATTER (COMPOST) 0.2% PHOSPHORUS MAX 3" MULCH LAYER BIORETENTION AREAS TOP OF MULCH ELEV. BIORETENTION AREA #1 = 209.25 BIORETENTION AREA #2 = 209.0 SEE SITE PLAN FOR GRADING 0.3 MIL MIN. POLY LINER TO BE INSTALLED AROUND ENTIRE BIORETENTION AREA AND BENEATH UNDERDRAIN. CONTRACTOR TO ENSURE LINER IS SEALED AND WATERTIGHT. ENGINEER TO VERIFY LINER INSTALLATION PRIOR TO BACKFILL. LINER TO EXTEND 2' MINIMUM UP SIDES OF BASIN SW-027LAST REVISED 03/05/2014TRUDELL CONSULTING ENGINEERS BIORETENTION UNDERDRAIN CLEANOUT 4" PVC SDR 35 RISER 4" PVC SDR 35 ELBOW 6"X6"X4" PVC SDR 35 45° WYE 6" PERF. SDR 35 PVC PIPE 6"FLOW NOTE: SEE SITE PLAN FOR PIPE SIZE AND INVERT. NOTE: SEE SITE PLAN FOR CORE LOCATION, PIPE SIZE AND INVERT. 4" PVC CAP TO EXTEND 3" ABOVE TOP OF MULCH SEE DETAIL BELOW FOR BIORETENTION SOIL LAYERS 12" HDPE 12" BEEHIVE GRATE 1 2 BIORETENTION OUTLET STRUCTURES 12" GRAVEL BELOW OUTLET STRUCTURE 36" DIAMETER HDPE OR PRECAST OUTLET STRUCTURE 6" UNDERDRAIN LINER TO BE INSTALLED ON BASIN SIDE OF OUTLET STRUCTURE WITH A WATERTIGHT CONNECTION FOR UNDERDRAIN CONNECTION TO OUTLET STRUCTURE. ENGINEER TO VERIFY LINER ADJACENT TO STRUCTURE PRIOR TO BACKFILL. CONTRACTOR TO TAKE MEASURES TO ENSURE CONNECTIONS ARE WATER TIGHT INVERT LOCATIONS AND ELEVATIONS SHOWN ON SITE PLANS Sheet Title Project Title Use of These Drawings Scale: Project Number: Date: Drawn By: Project Engineer: Approved By: No. Description Date By Revisions 478 BLAIR PARK ROAD | WILLISTON, VERMONT 05495 802 879 6331 | WWW.TCEVT.COM ENGINEERING SURVEY No. 8917 CIVIL PROF ESSIONAL E N G INEERLICE N S E DJENNIFER ANN DESA UT ELSSTATE O F VER M ONT Field Book: 1. Unless otherwise noted, these Drawings are intended for preliminary planning, coordination with other disciplines or utilities, and/or approval from the regulatory DXWKRULWLHV¬ They are not intended as construction drawings unless noted as such or marked approved by a regulatory authority. 2. By use of these drawings for construction of the Project, the Owner represents that they have reviewed, approved, and accepted the drawings, obtained all necessary permits, and have met with all applicable parties/disciplines, including but not limited to, the Engineer and the Architect, to insure these plans are properly coordinated including, but not limited to, contract documents, specifications, owner/contractor agreements, building and mechanical plans, private and public utilities, and other pertinent permits for construction. 3. Owner and Architect, are responsible for final design and location of buildings shown, including an area measured a minimum five (5) feet around any building and coordinating final utility connections shown on these plans. 4. Prior to using these plans for construction layout, the user shall contact TCE to ensure the plan contains the most current revisions. 5. These Drawings are specific to the Project and are not transferable. As instruments of service, these drawings, and copies thereof, furnished by TCE are its exclusive SURSHUW\¬ Changes to the drawings may only be made by TCE. If errors or omissions are discovered, they shall be brought to the attention of TCE immediately. 6. It is the User's responsibility to ensure this copy contains the most current revisions. PLANNING ENVIRONMENTAL Stormwater Details C8-06 6/18/20 ¬ 19-202 CMJ JAD ¬¬ 348 Bacon St. Properties, LLC 510 Shelburne Road South Burlington, Vermont SEE SITE PLANS FOR LOCATIONS, PIPE SIZES, AND INVERT ELEVATIONS RAIN GUARDIAN TURRET DETAIL  Sheet Title Project Title Use of These Drawings Scale: Project Number: Date: Drawn By: Project Engineer: Approved By: No. Description Date By Revisions 478 BLAIR PARK ROAD | WILLISTON, VERMONT 05495 802 879 6331 | WWW.TCEVT.COM ENGINEERING SURVEY No. 8917 CIVIL PROF ESSIONAL E N G INEERLICE N S E DJENNIFER ANN DESA U T ELSSTA TE O F VER M ONT Field Book: 1. Unless otherwise noted, these Drawings are intended for preliminary planning, coordination with other disciplines or utilities, and/or approval from the regulatory authorities.  They are not intended as construction drawings unless noted as such or marked approved by a regulatory authority. 2. By use of these drawings for construction of the Project, the Owner represents that they have reviewed, approved, and accepted the drawings, obtained all necessary permits, and have met with all applicable parties/disciplines, including but not limited to, the Engineer and the Architect, to insure these plans are properly coordinated including, but not limited to, contract documents, specifications, owner/contractor agreements, building and mechanical plans, private and public utilities, and other pertinent permits for construction. 3. Owner and Architect, are responsible for final design and location of buildings shown, including an area measured a minimum five (5) feet around any building and coordinating final utility connections shown on these plans. 4. Prior to using these plans for construction layout, the user shall contact TCE to ensure the plan contains the most current revisions. 5. These Drawings are specific to the Project and are not transferable. As instruments of service, these drawings, and copies thereof, furnished by TCE are its exclusive property.  Changes to the drawings may only be made by TCE. If errors or omissions are discovered, they shall be brought to the attention of TCE immediately. 6. It is the User's responsibility to ensure this copy contains the most current revisions. PLANNING ENVIRONMENTAL Erosion, Prevention & Sediment Control C8-07 06/04/2020 Shown 19-202 RMP JAD    348 Bacon St. Properties, LLC 510 Shelburne Road South Burlington, Vermont OHOHOHOHOHOHOHOHOHOHOHOH GGGWW W W W W W W W W W SSSSSSSSSS S S S D D D SDS210210 210 210 210 210WDDDDDDDDDDDDDDWWWWUG UG UG BACON STREET U.S. ROUTE 7 / SHELBURNE ROADPROPOSED BUILDING 4,930 SF FINISHED FLOOR ELEVATION = 211.90DDDDD D D D D D D D D D D D D D D D D D DRDRDRD D DDDDD209 210211 211 211 21121 1211210210 210 210 210209 2 1 1 211 SSSSSSSSSSSSSS S S S D RDRDRDRDRDRDRDRDRD211210DDDD1 0 ' M IN . TOCEN T E ROF T R E E 9 EP 1 BN 10 EP 1 BN 1 GT 1 GB 1 GB 1 GB 1 GT 1 GT 16 RF 12 HJS 7 EP 12 RF 9 EP 9 HJU 6 RR 9 HJU 12 HJS 8 HP 1 CV 1 CV 12 HSD 10 HSD 8 HP 6 RR 13 HSD 12 EP 5 SSC 3 RR 6 RR 8 EP 12 EP 14 CAF 5 IV 1 CAH1 CAH 12 SSC 24 HJS 1 GT 5 SSC 7 HJS 15 EP 3 RR8 HJU 6 EP 6 RF 1 CAH 1 CAH 13 CAF 11 RF 8 IV 4 ELJ 7 IV 11 PVS 1 CAH 5 ELJ 6 EP 8 ELJ 1 CAH 12 RF 10 MD 10 MD 1 AG 27 SJS 1 MS 1 MS 1 MS 14 MD 7 HAU 8 AD 8 CG 7 EM 1 IVM 1 IVF 8 PVS 1 IVF 1 IVF 11 EP 17 CAF 12 HSD 1 HAP 11 CAF 1 HAP 12 CAF 1 HAP 12 CAF 1 HAP 12 CAF BIORETENTION BASIN 2 SEE SEPARATE PLANT LIST 3 BIKE RACKS 1 AG LAWN SEEDING (TYPICAL) HELIO M30/K4 SECURITY BOLLARD, SERIES 900, NON-ILLUMINATED (TYPICAL) 3 AG BIORETENTION BASIN 1 SEE SEPARATE PLANT LIST UD UD UDUDUD 0 Feet Graphic Scale 10 10 20 15°±VT GridMagneticSheet Title Project Title Use of These Drawings Scale: Project Number: Date: Drawn By: Project Engineer: Approved By: No. Description Date By Revisions 478 BLAIR PARK ROAD | WILLISTON, VERMONT 05495 802 879 6331 | WWW.TCEVT.COM ENGINEERING SURVEY Field Book: 1. Unless otherwise noted, these Drawings are intended for preliminary planning, coordination with other disciplines or utilities, and/or approval from the regulatory authorities.  They are not intended as construction drawings unless noted as such or marked approved by a regulatory authority. 2. By use of these drawings for construction of the Project, the Owner represents that they have reviewed, approved, and accepted the drawings, obtained all necessary permits, and have met with all applicable parties/disciplines, including but not limited to, the Engineer and the Architect, to insure these plans are properly coordinated including, but not limited to, contract documents, specifications, owner/contractor agreements, building and mechanical plans, private and public utilities, and other pertinent permits for construction. 3. Owner and Architect, are responsible for final design and location of buildings shown, including an area measured a minimum five (5) feet around any building and coordinating final utility connections shown on these plans. 4. Prior to using these plans for construction layout, the user shall contact TCE to ensure the plan contains the most current revisions. 5. These Drawings are specific to the Project and are not transferable. As instruments of service, these drawings, and copies thereof, furnished by TCE are its exclusive property.  Changes to the drawings may only be made by TCE. If errors or omissions are discovered, they shall be brought to the attention of TCE immediately. 6. It is the User's responsibility to ensure this copy contains the most current revisions. PLANNING ENVIRONMENTAL   TAX ID: 1540-00510 Landscape Plan LA 2-01 06/04/2020 1" = 10' 19-202 RMP JAD    348 Bacon St. Properties, LLC 510 Shelburne Road South Burlington, Vermont Sheet TitleProject TitleUse of These DrawingsScale:Project Number:Date:Drawn By:Project Engineer:Approved By:No. Description DateByRevisions478 BLAIR PARK ROAD | WILLISTON, VERMONT 05495802 879 6331 | WWW.TCEVT.COMENGINEERING SURVEYNo. 8917CIVILPROFESSIONALENGINEERLICENSED JEN NI F ER ANN DESAUTELSST A T E OF VERMONTField Book:1. Unless otherwise noted, these Drawings are intended forpreliminary planning, coordination with other disciplines orutilities, and/or approval from the regulatory authorities. They are not intended as construction drawings unless notedas such or marked approved by a regulatory authority.2. By use of these drawings for construction of the Project,the Owner represents that they have reviewed, approved,and accepted the drawings, obtained all necessary permits,and have met with all applicable parties/disciplines,including but not limited to, the Engineer and the Architect,to insure these plans are properly coordinated including, butnot limited to, contract documents, specifications,owner/contractor agreements, building and mechanicalplans, private and public utilities, and other pertinent permitsfor construction.3. Owner and Architect, are responsible for final design andlocation of buildings shown, including an area measured aminimum five (5) feet around any building and coordinatingfinal utility connections shown on these plans.4. Prior to using these plans for construction layout, the usershall contact TCE to ensure the plan contains the mostcurrent revisions.5. These Drawings are specific to the Project and are nottransferable. As instruments of service, these drawings, andcopies thereof, furnished by TCE are its exclusive property. Changes to the drawings may only be made by TCE. Iferrors or omissions are discovered, they shall be brought tothe attention of TCE immediately.6. It is the User's responsibility to ensure this copy containsthe most current revisions.PLANNING ENVIRONMENTAL TAX ID: 1540-00510Landscape DetailsLA 2-0206/04/2020 Shown19-202RMPJAD  348Bacon St. Properties,LLC510 Shelburne RoadSouth Burlington, VermontL-020SHRUB PLANTINGTRUDELL CONSULTING ENGINEERSLAST REVISED 02/10/2020SPACING "D"ROW "A"NUMBER OFPLANTS/SQ. FT.5' O.C.4' O.C.36" O.C.30" O.C.24" O.C.41.52"31.20"26.00"20.76"51.96"0.280.180.040.120.07DADDDAD1'-0"MINSEE PLANFOR SPACINGSEE SPECS. FOR DEPTH CONTINUOUS PLANTING PIT FILLED WITH PLANTING MIXREFER TO SOIL PREPARATION SPECIFICATIONSSHRUB ROOTBALLMULCH, AS SPECIFIEDFINISH GRADEPLANT SPACINGPLANT CENTERPLANT ROWALL EQUAL ORAS SHOWN ONPLANTING PLANNOTE:1.QUANTITY OF SHRUBS AND SPACING AS NOTEDIN PLANTING SCHEDULE.2.CONTINUOUS PLANTING PITS FILLED WITHPLANTING MIX PER THE DEPTH AS NOTED IN THESPECIFICATIONS IS REQUIRED.SUB GRADEL-021PERENNIAL PLANTINGLAST REVISED 02/10/2020TRUDELL CONSULTING ENGINEERSSEE PLANTING LIST FOR PLANT SPACING2"PLANT SPACINGPLANT CENTERPLANT ROWSEE PLANTING PLAN FORSPACING AND QUANTITIESSET AT ORIGINAL PLANTING DEPTHFINISH GRADEMULCH AS SPECIFIEDCONTINUOUS PLANTING PITFILLED WITH PLANTING MIXREFER TO SOIL PREPARATIONSPECIFICATIONSSUB GRADEL-0221" = 1'LAWN SEEDINGLAST REVISED 02/11/20TRUDELL CONSULTING ENGINEERSNOTE: ALL DISTURBED AREAS SHALL BE LOAMEDAND SEEDED UNLESS NOTED OTHERWISE6"SEED AS SPECIFIEDPLANTING SOIL MIX,(ROLLED THICKNESS)FREE DRAINING,SCARIFIEDSUBGRADEL-0231" = 1'GROUNDCOVERLAST REVISED 03/26/2020TRUDELL CONSULTING ENGINEERS12" MIN.2" BARKGROUNDCOVERMULCHPLANTING SOIL MIXFREE DRAINING,SCARIFIED SUBGRADEL-0261/2" = 1'EVERGREEN TREE PLANTINGTRUDELL CONSULTING ENGINEERSLAST REVISED 03/26/202012"LENGTH SET BYHEIGHT OFROOTBALL312" SHREDDED BARK MULCH, AS SPECIFIED(HOLD MULCH OFF ROOT FLARE)2"X2"X10' FIR STAKES , STAINED BLACK; 3 PER TREEEQUALLY SPACED AROUND ROOT BALL; ALL POSTS SHALLBE PLUMB AND HAVE SAME HEIGHT ABOVE FINISHGRADE. GUY WIRE SHALL BE NEW PLIABLE ANNEALEDGALVANIZED SOFT STEEL WIRE OF NO. TEN(10) GAUGESIZE. ENCASE WIRE AROUND TRUNK IN TWO-PLY, BLACK,REINFORCED RUBBER GARDEN HOSETREE SHALL BE PLANTED WITH TOP OF ROOTBALLBEARING THE SAME RELATIONSHIP TO FINISHED GRADEAS TO PREVIOUS EXISTING GRADE. TREE SHALL BEPLUMB AFTER SETTLEMENT.4'PLANTING SOIL MIXROLL BURLAP BACK FROM TOP 1/3 OFROOTBALL BEFORE BACKFILLING. UNTIEROPE FROM TRUNK.FREE DRAINING SCARIFIED SUBGRADEL-028SHRUB PLANTINGLAST REVISED 02/29/2020TRUDELL CONSULTING ENGINEERS12" MIN.PLACE SHRUBS PERPENDICULAR TO GRADECURB2" BARK MULCH: PULL MULCH AWAY FROM BASE OF SHRUB,HOLD TOP OF SETTLED MULCH 1" BELOW CURBPLANTING SOIL MIX THROUGHOUTENTIRE PLANTING AREAFINISH GRADEPLACE ROOTBALLON COMPACTEDSUBGRADEFREE DRAINING SCARIFIEDUNDISTURBED SUBGRADE1" = 1'L-0291" = xx'LAST REVISED 02/26/2020TRUDELL CONSULTING ENGINEERSTREE PROTECTIONFOR TREES TO REMAIN WITHIN LIMIT OF LANDSCAPEWORK AREA:CONTRACTOR SHALL CONTACT ARBORIST PRIOR TODEMOLITION TO PERFORM RECOMMENDED TREATMENTS(FERTILIZER, ROOT PRUNE, ETC.) ON SPECIMEN TREES TOREMAIN BEFORE BEGINNING DEMOLITION.PLAN VIEWEXISTINGTREEEXISTINGTREE6' MIN.SECTION VIEWPRUNE PER ISA STANDARDS. REMOVE DEAD &DAMAGED BRANCHES. TIE BRANCHES UP TO AVOIDDAMAGE FROM CONSTRUCTION EQUIPMENT.EXISTING TREE (S)LIMIT OF DRIPLINE(VARIES)WOODEN OR METAL POSTS (TYPICAL)INSTALL FENCING AT EDGE OF DRIPLINE OR AS FARFROM TRUNK AS POSSIBLE. MIN. DISTANCE IS 6' FROMTRUNK. MAY BE PLASTIC SNOW FENCE OR CHAINLINK, MIN. 4' HIGH.ZONE OF CONSTRUCTION IMPACT (CUT/FILL)PRUNE DAMAGED OR EXPOSED ROOTSDAMAGED WITH A SHARP SAW.LIMIT OF FENCING(INDIVIDUAL TREE)LIMIT OF FENCING (MULTIPLE TREES)EXISTING GRADELIMIT OF CONSTRUCTION IMPACT (REFER TO PLANS)LIMIT OF FENCE (INDIVIDUAL TREE)LIMIT OFCANOPY(VARIES)LIMIT OF FENCING(MULTIPLE TREES)WOODEN OR METAL POSTS (MAX. 8' SPACING)2x4 DIM. LUMBER ATTACHED W/METALSTRAPPING (OPT) AT 2 LOCATIONS(MIN.). CLADDING SHALL BE 8' HIGHWITH 6" SPACING OF BOARDS. WRAPBARK W/BURLAP PRIOR TO ARMORING,OR APPROVED ALTERNATIVE METHODNO STORAGE OF EQUIPMENT OFMATERIALS WITHIN DRIPLINEL-019TREE PLANTINGTRUDELL CONSULTING ENGINEERSLAST REVISED 03/26/202018"18"12"MIN.NOTE: EXAMINE ENTIRE TREE AND REMOVEALL NURSERY TAGS, ROPE, STRING, ORSURVEYORS TAPE TO PREVENT FUTUREGIRDLING.SURROUNDING SOIL SHOULD NOT EXCEED80% COMPACTION, DRAINAGE WILL BEREQUIRED IF COMPACTED SOILS ARE PRESENTPLANTING PIT IS(3) TIMESTHE DIAMETER OFTHE ROOT BALLNOTE:1. ALL TREE PLANTING BEDS ARE TO BE CONTINUOUS,COMPLETELY DUG OUT AND BACKFILLED WITH THEPROPER PLANTING BED BACKFILL MATERIAL.NYLON STRAPWITH 3/4" GROMMETSFASTEN WIRE BELOW POINT OFMAJOR BRANCHING OR TO MAJOROUTSIDE TRUNK.2 12" HARDWOOD STAKES. ALIGNSTAKES PARALLEL W/ ROAD/ WALKSOR PARALLEL W/ DIRECTION OFPREVAILING WINDTEMPORARY WATERING BASINBREAK APART EDGE OF EXCAVATIONW/ SHOVEL AND BLEND PLANT MIXW/ EXISTING SOIL TO PROVIDETRANSITION TO UNDISTURBED GRADEUNDISTURBED GRADE EXCAVATEONLY TO SPECIFIED PLANTINGDEPTH TO ENSURE STABLE BASEFINISH GRADEBACKFILL MIX FOR TREE PLANTING BEDSREMOVE TOP HALF OF WIRE CAGECUT AND REMOVE BURLAPFROM ROOTBALL2" HEMLOCK BARK MULCH, KEPT 3" MIN AWAY FROM TRUNKTOP OF ROOTBALL, ROOT FLARE SHOULDBE EVIDENT. IF ROOT FLARE IS NOT EVIDENT,THEN SCRAPE OFF THE TOP LAYER OF SOILBUILD UP ON TOP OF ROOTBALL FROM NURSERY.DECIDUOUS TREESPECIALFREESTANDING WALLTRUDELL CONSULTING ENGINEERSLAST REVISED 06/11/20201" = 1'CONCRETE SIDEWALK3.5" PRECAST STONE CAP, NATURALSTONE FINISHFINISH GRADE VARIES,SEE PLANSFREE DRAINING,SCARIFIEDSUBGRADE6"PLANTING SOIL MIX,(ROLLED THICKNESS)1/2" EXPANSION JOINT WITHNON-SHRINK EPOXYMORTAR (TYPICAL)20"3"1'-6" 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.4 0.5 0.7 0.5 0.4 0.3 0.3 0.4 0.4 0.3 0.3 0.3 0.3 0.3 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.2 0.3 0.4 0.2 0.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.6 1.7 2.4 1.5 0.7 0.7 0.9 1.0 1.0 0.9 0.6 0.6 0.8 1.2 1.0 0.5 0.4 0.4 0.4 0.2 0.1 0.4 0.7 1.1 0.7 0.4 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.8 2.2 2.6 1.7 1.1 1.5 2.3 2.2 2.3 2.2 1.4 0.9 1.4 3.0 1.7 0.8 0.8 1.1 0.9 0.5 0.2 0.6 1.8 2.8 1.8 0.5 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.3 0.8 1.2 3.8 3.5 3.6 3.8 2.1 1.1 1.3 3.0 1.5 1.1 1.6 2.7 2.1 0.9 0.4 0.6 1.2 2.0 1.3 0.4 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.5 1.1 1.7 1.1 0.5 0.4 0.5 0.6 0.4 0.3 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.3 0.6 1.5 2.7 0.2 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.3 0.6 1.4 2.5 0.4 0.2 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.3 0.6 1.0 1.5 0.8 0.5 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.2 0.4 0.7 1.0 1.3 1.7 0.9 0.4 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.5 0.9 1.6 2.0 2.4 1.2 0.5 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.1 0.3 0.6 1.2 2.3 3.2 1.8 0.9 0.4 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.2 0.4 0.7 1.3 2.2 3.0 0.8 0.5 0.3 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.2 0.5 0.8 1.1 1.6 0.5 0.4 0.3 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.2 0.7 0.9 1.0 1.2 0.8 0.9 1.3 2.2 3.4 3.0 1.8 1.2 1.5 0.4 0.4 0.3 0.3 0.2 0.1 0.0 0.0 0.0 0.0 0.1 0.2 0.9 1.1 1.1 1.1 0.9 1.0 1.2 1.8 2.4 2.2 1.5 1.2 1.4 2.3 2.8 2.0 1.3 1.2 1.8 3.0 3.0 1.8 0.9 0.6 0.8 0.9 0.9 0.6 0.4 0.1 0.0 0.0 0.0 0.0 0.1 0.2 1.1 1.3 1.3 1.2 1.1 1.1 1.1 1.3 1.4 1.4 1.1 1.0 1.1 1.4 1.6 1.3 1.0 1.0 1.4 2.0 2.0 1.4 0.9 0.7 1.1 1.8 2.2 1.4 0.5 0.1 0.0 0.0 0.0 0.0 0.1 0.3 1.5 1.5 1.5 1.4 1.2 1.1 1.1 1.1 1.1 1.0 0.9 0.9 0.9 1.0 1.0 0.9 0.9 0.9 1.0 1.2 1.2 1.0 0.8 0.7 1.3 2.8 3.0 1.8 0.7 0.2 0.1 0.0 0.0 0.0 0.2 0.3 1.7 1.8 1.7 1.6 1.4 1.2 1.1 1.0 1.0 0.9 0.9 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.9 0.9 0.9 0.9 0.8 0.8 1.2 1.4 1.7 1.2 0.7 0.2 0.1 0.0 0.0 0.0 0.2 0.3 2.0 2.1 1.9 1.7 1.5 1.3 1.2 1.1 1.0 0.9 0.9 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.9 0.9 0.9 0.9 1.0 1.0 1.1 0.9 0.6 0.3 0.0 0.0 0.0 0.0 0.0 0.0 2.2 2.1 1.9 1.7 1.5 1.4 1.3 1.1 1.0 1.0 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 1.0 1.0 1.0 0.9 0.9 0.9 0.7 0.3 0.0 0.0 0.0 0.0 0.2 0.4 2.1 2.1 1.9 1.7 1.6 1.5 1.3 1.2 1.2 1.1 1.1 1.1 1.1 1.1 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.1 1.1 1.1 1.1 1.1 1.1 0.8 0.2 0.0 0.0 0.0 0.0 0.2 0.6 1.8 1.9 1.8 1.7 1.6 1.5 1.4 1.3 1.3 1.3 1.2 1.3 1.3 1.3 1.3 1.2 1.2 1.1 1.1 1.1 1.1 1.1 1.2 1.2 1.3 1.3 1.4 1.3 1.1 0.1 0.1 0.0 0.0 0.0 0.1 0.1 0.7 1.5 1.6 1.6 1.6 1.6 1.5 1.5 1.4 1.4 1.4 1.4 1.5 1.5 1.5 1.5 1.5 1.4 1.3 1.2 1.2 1.2 1.2 1.3 1.4 1.5 1.6 1.7 1.6 1.2 0.2 0.1 0.1 0.0 0.1 0.1 0.8 1.3 1.4 1.4 1.5 1.6 1.6 1.5 1.5 1.5 1.5 1.6 1.7 1.8 1.8 1.8 1.8 1.7 1.5 1.4 1.3 1.3 1.3 1.4 1.5 1.7 1.8 1.9 1.9 1.1 0.2 0.1 0.1 0.0 0.0 0.1 0.7 1.0 1.1 1.3 1.5 1.6 1.6 1.6 1.6 1.6 1.7 1.8 2.0 2.1 2.1 2.1 2.1 1.9 1.7 1.5 1.4 1.4 1.4 1.5 1.6 1.8 1.9 2.1 2.1 0.9 0.2 0.1 0.1 0.1 0.0 0.1 0.5 0.8 0.9 1.2 1.4 1.6 1.6 1.6 1.6 1.7 1.8 1.9 2.1 2.3 2.4 2.4 2.4 2.2 1.9 1.6 1.5 1.4 1.4 1.5 1.6 1.8 1.9 2.1 2.2 0.0 0.0 0.2 0.1 0.1 0.0 0.1 0.4 0.6 0.7 1.2 1.5 1.6 1.6 1.6 1.6 1.7 1.8 2.0 2.1 2.4 2.6 2.6 2.5 2.2 2.0 1.7 1.6 1.4 1.4 1.4 1.5 1.7 1.9 2.1 2.0 0.5 0.2 0.1 0.1 0.1 0.0 0.1 0.3 0.5 0.6 1.2 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.6 1.6 1.6 1.7 1.7 1.7 1.7 1.6 1.5 1.3 1.2 1.2 1.2 1.3 1.5 1.7 1.8 1.7 0.4 0.2 0.1 0.1 0.0 0.1 0.2 0.4 0.5 1.3 1.7 1.6 1.5 1.4 1.3 1.1 0.9 0.9 0.8 0.8 0.8 0.5 0.7 0.7 0.7 0.7 0.6 0.9 1.0 1.0 1.1 1.2 1.4 1.5 1.5 0.4 0.1 0.1 0.1 0.0 0.4 1.5 1.9 1.8 1.6 1.4 1.2 1.1 1.0 0.9 0.9 1.0 1.1 1.2 1.3 1.2 1.1 1.0 1.0 1.1 1.2 1.3 1.4 1.5 1.5 1.4 1.3 0.4 0.1 0.1 0.0 0.0 0.3 0.4 1.6 2.1 2.0 1.8 1.5 1.3 1.2 1.1 1.0 1.1 1.1 1.3 1.5 1.8 2.0 2.3 2.5 2.6 2.5 2.3 2.1 1.9 1.7 1.5 1.4 1.2 0.5 0.2 0.1 0.1 0.0 0.2 0.4 1.8 2.3 2.1 1.8 1.6 1.4 1.2 1.1 1.1 1.1 1.2 1.3 1.5 1.7 2.0 2.2 2.4 2.5 2.4 2.3 2.0 1.8 1.6 1.5 1.3 1.0 0.6 0.3 0.2 0.1 0.1 0.2 0.3 1.8 2.2 2.0 1.7 1.5 1.3 1.2 1.1 1.1 1.1 1.1 1.2 1.2 1.5 1.8 2.0 2.1 2.1 2.1 2.0 1.8 1.6 1.4 1.3 1.2 0.9 0.6 0.3 0.2 0.1 0.1 0.2 0.3 1.9 2.1 1.9 1.7 1.5 1.3 1.2 1.1 1.0 1.0 1.0 1.1 1.2 1.4 1.5 1.7 1.8 1.8 1.8 1.7 1.6 1.4 1.3 1.2 1.0 0.8 0.5 0.3 0.2 0.1 0.1 0.1 0.2 1.7 1.8 1.7 1.5 1.3 1.2 1.1 1.0 1.0 1.0 1.0 1.0 1.1 1.2 1.3 1.4 1.5 1.5 1.5 1.4 1.3 1.2 1.1 1.0 0.8 0.6 0.4 0.3 0.2 0.1 0.1 0.1 0.3 1.4 1.5 1.4 1.3 1.2 1.1 1.0 0.9 0.9 0.9 0.9 1.0 1.0 1.0 1.1 1.2 1.2 1.2 1.2 1.2 1.1 1.0 0.9 0.8 0.7 0.5 0.4 0.3 0.2 0.1 0.1 0.1 0.4 1.1 1.2 1.2 1.1 1.0 1.0 0.9 0.9 0.8 0.8 0.8 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.8 0.8 0.7 0.6 0.4 0.3 0.3 0.2 0.1 0.1 0.0 0.4 0.9 1.0 0.9 0.9 0.9 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.6 0.5 0.5 0.4 0.3 0.2 0.2 0.1 0.0 0.4 0.6 0.8 0.8 0.8 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.5 0.5 0.5 0.4 0.4 0.3 0.3 0.2 0.2 0.1 0.0 0.1 0.3 0.5 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.5 0.5 0.5 0.5 0.5 0.5 0.4 0.4 0.4 0.4 0.3 0.3 0.3 0.2 0.2 0.1 0.1 0.0 0.1 0.2 0.4 0.5 0.5 0.5 0.5 0.5 0.6 0.6 0.5 0.5 0.5 0.5 0.5 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.1 0.1 0.0 0.1 0.1 0.3 0.4 0.4 0.4 0.4 0.5 0.5 0.5 0.5 0.5 0.4 0.4 0.4 0.4 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.0 0.0 0.1 0.2 0.3 0.3 0.3 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.3 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.0 0.3 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.1 0.1 0.1 0.1 0.0 0.0 0.0 OHOHOHOHOHOHOHOHOHOHOHOHOHOH OH OH OH OH OH OH OH OH OH OH OH OHUG GGGGWG G G W W W W W W W W W W W W W W SSSSSSSSSS S S S S SSW D D DD SDD SSWWD D D D D D D D DDDDDDDDDDDDDDDWWWWUG UG UG BACON STREET BOUNDARY LINE TO BE DISSOLVEDPROPOSED BUILDING 4,930 SF FINISHED FLOOR ELEVATION = 211.90DDDDD D D D D D D D D D D D D D D D D D DRDRDRD D DDDDDA A A B A A A AB B B C C C C A A C S SSSSSSSSSSSSS S S S D RDRDRDRDRDRDRDRDRDDDDD3 BIKE RACKS HELIO M30/K4 SECURITY BOLLARD, SERIES 900, NON-ILLUMINATED (TYPICAL) C UD UD UDUDUD 0 Feet Graphic Scale 10 10 20 15°±VT GridMagneticSheet Title Project Title Use of These Drawings Scale: Project Number: Date: Drawn By: Project Engineer: Approved By: No. Description Date By Revisions 478 BLAIR PARK ROAD | WILLISTON, VERMONT 05495 802 879 6331 | WWW.TCEVT.COM ENGINEERING SURVEY Field Book: 1. Unless otherwise noted, these Drawings are intended for preliminary planning, coordination with other disciplines or utilities, and/or approval from the regulatory authorities.  They are not intended as construction drawings unless noted as such or marked approved by a regulatory authority. 2. By use of these drawings for construction of the Project, the Owner represents that they have reviewed, approved, and accepted the drawings, obtained all necessary permits, and have met with all applicable parties/disciplines, including but not limited to, the Engineer and the Architect, to insure these plans are properly coordinated including, but not limited to, contract documents, specifications, owner/contractor agreements, building and mechanical plans, private and public utilities, and other pertinent permits for construction. 3. Owner and Architect, are responsible for final design and location of buildings shown, including an area measured a minimum five (5) feet around any building and coordinating final utility connections shown on these plans. 4. Prior to using these plans for construction layout, the user shall contact TCE to ensure the plan contains the most current revisions. 5. These Drawings are specific to the Project and are not transferable. As instruments of service, these drawings, and copies thereof, furnished by TCE are its exclusive property.  Changes to the drawings may only be made by TCE. If errors or omissions are discovered, they shall be brought to the attention of TCE immediately. 6. It is the User's responsibility to ensure this copy contains the most current revisions. PLANNING ENVIRONMENTAL 06/04/2020 1" = 10' 19-202 NPC JAD    348   TAX ID: 1540-00510 AVG. ILLUMINATION AVG. ILLUMINATION UNIFORMITY RATIO MAX. POINT (HORIZONTAL)(VERTICAL) ILLUMINATION LUMINAIRE SCHEDULE SYMBOL LABEL QTY CATALOG NUMBER DESCRIPTION LAMP A 9 MOUNT HEIGHT 11 FTVMMV-L10-840-TL-S-DGL 13 Watt C LEDECF-S-3L-530-NW-G2-4-HIS B LBLHO-6036 20 FT 3.5 FT NOTES: 1.AREA LIGHT AND BUILDING LAYOUT AS SHOWN FOR PERMITTING AND INSTALLATION PURPOSES. BUILDING-MOUNTED FIXTURES ARE SHOWN FOR PERMITTING PURPOSES ONLY. 2.DISCREPANCIES BETWEEN L2-01 AND OTHER CIVIL, ELECTRICAL, OR ARCHITECTURAL PLANS SHOULD BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO INSTALLATION. 3.QUANTITIES AND CATALOG NUMBER SHOWN IN TABLE SHOULD BE VERIFIED BY ELECTRIC CONTRACTOR PRIOR TO ORDERING. 2 5 Lighting Plan LI 2-01 06/04/2020 1" = 10' 19-202 NPC JAD    348 Bacon St. Properties, LLC 510 Shelburne Road South Burlington, Vermont ZONE 1 0.8 fc n/a n/a 3.8 fc LEGEND 0.5 FOOTCANDLES (fc) 1.0 FOOTCANDLES (fc) 2.0 FOOTCANDLES (fc) WILLIAMS VOLTAIRE ARCH. MINI WALLPACK - VWM VERTICAL 13W LED 4000K FORMS & SURFACES HELIOS BALLARD - 360 DEGREES 32W LED 4000K GARDCO ECOFORM AREA - AMALL TYPE IV WITH HOUSE-SIDE INTERNAL SHIELDING Sheet Title Project Title Use of These Drawings Scale: Project Number: Date: Drawn By: Project Engineer: Approved By: No. Description Date By Revisions 478 BLAIR PARK ROAD | WILLISTON, VERMONT 05495 802 879 6331 | WWW.TCEVT.COM ENGINEERING SURVEY Field Book: 1. Unless otherwise noted, these Drawings are intended for preliminary planning, coordination with other disciplines or utilities, and/or approval from the regulatory authorities.  They are not intended as construction drawings unless noted as such or marked approved by a regulatory authority. 2. By use of these drawings for construction of the Project, the Owner represents that they have reviewed, approved, and accepted the drawings, obtained all necessary permits, and have met with all applicable parties/disciplines, including but not limited to, the Engineer and the Architect, to insure these plans are properly coordinated including, but not limited to, contract documents, specifications, owner/contractor agreements, building and mechanical plans, private and public utilities, and other pertinent permits for construction. 3. Owner and Architect, are responsible for final design and location of buildings shown, including an area measured a minimum five (5) feet around any building and coordinating final utility connections shown on these plans. 4. Prior to using these plans for construction layout, the user shall contact TCE to ensure the plan contains the most current revisions. 5. These Drawings are specific to the Project and are not transferable. As instruments of service, these drawings, and copies thereof, furnished by TCE are its exclusive property.  Changes to the drawings may only be made by TCE. If errors or omissions are discovered, they shall be brought to the attention of TCE immediately. 6. It is the User's responsibility to ensure this copy contains the most current revisions. PLANNING ENVIRONMENTAL 06/04/2020 Shown 19-202 RMP JAD    348   TAX ID: 1540-00510 LI-001LAST REVISED 03/27/2019TRUDELL CONSULTING ENGINEERS TYPICAL LUMINAIRE GRASS AREAS PAVED AREAS A:MOUNT HEIGHT VARIES. REFER TO LIGHTING PLAN B:BASE DEPTH 6 FT. MIN. FOR UP TO 20 FT. MOUNT HEIGHT. 8 FT. MIN. FOR UP TO 30 FT. C:PRECAST FOOTING DIAMETER DETERMINED BY BASE PLATE D:SUBMIT SHOP DRAWINGS FOR REVIEW PRIOR TO CONSTRUCTION. NOTE: BOLT PATTERN, CONDUIT SIZE AND GROUNDING TO BE DETERMINED BY LIGHTING/ELECTRIC CONTRACTOR B℄24"AMOUNT HEIGHT VARIESAMOUNT HEIGHT VARIESC BREFER TO LIGHTING PLAN FOR FIXTURE STYLE & WATTAGE PAINT EXPOSED FOOTING YELLOW4"CLASS B CONCRETE FOOTING LI-007LAST REVISED 03/27/2019TRUDELL CONSULTING ENGINEERS LUMINAIRE FOOTING BASE PLATE GROUNDING BUSHING (2 PCS) LIGHT POLE HAND HOLE AND COVER GROUNDING TERMINAL NOTES: 1.FOOTING DIMENSIONS DEPENDENT ON ACTUAL FIXTURE USED. 2.SEE MANUFACTURER'S SPECS FOR BOLT PATTERN LAYOUT. 3.CONTRACTOR SHALL VERIFY FOOTING SIZE MEETS THE APPROPRIATE CODES FOR HEIGHT OF POLES SHOWN. 4.SUBMIT SHOP DRAWINGS FOR REVIEW PRIOR TO CONSTRUCTION.5'-0"24" MIN.COVERSTEEL ANCHOR BOLTS FINISHED GRADE 1/2" PVC CONDUIT 3/4" PVC SCH 40 OR RIGID GALVANIZED STEEL (2 PCS) GROUND18"6"Lighting Details LI 2-02 06/04/2020 Shown 19-202 RMP JAD    348 Bacon St. Properties, LLC 510 Shelburne Road South Burlington, Vermont